Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 40(1): 78-89, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11916276

RESUMO

HbA1C is the stable glucose adduct to the N-terminal group of the beta-chain of HbA0. The measurement of HbA1c in human blood is most important for the long-term control of the glycaemic state in diabetic patients. Because there was no internationally agreed reference method the IFCC Working Group on HbA1c Standardization developed a reference method which is here described. In a first step haemoglobin is cleaved into peptides by the enzyme endoproteinase Glu-C, and in a second step the glycated and non-glycated N-terminal hexapeptides of the beta-chain obtained are separated and quantified by HPLC and electrospray ionisation mass spectrometry or in a two-dimensional approach using HPLC and capillary electrophoresis with UV-detection. Both principles give identical results. HbA1c is measured as ratio between the glycated and non-glycated hexapeptides. Calibrators consisting of mixtures of highly purified HbA1c and HbA0 are used. The analytical performance of the reference method has been evaluated by an international network of reference laboratories comprising laboratories from Europe, Japan and the USA. The intercomparison studies of the network showed excellent results with intra-laboratory CVs of 0.5 to 2% and inter-laboratory CVs of 1.4 to 2.3%. Possible interferences have been carefully investigated. Due to the higher specificity of the reference method the results are lower than those generated with most of the present commercial methods which currently are calibrated with unspecific designated comparison methods. The new reference method has been approved by the member societies of the International Federation of Clinical Chemistry and Laboratory Medicine and will be the basis for the future uniform standardization of HbA1c routine assays worldwide.


Assuntos
Análise Química do Sangue/métodos , Análise Química do Sangue/normas , Hemoglobinas Glicadas/análise , Soluções Tampão , Calibragem , Cromatografia Líquida de Alta Pressão/instrumentação , Eletroforese Capilar , Europa (Continente) , Glicosilação , Humanos , Japão , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray , Estados Unidos
2.
Clin Chem Lab Med ; 40(7): 718-24, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12241021

RESUMO

This paper is the fourth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 2.


Assuntos
Alanina Transaminase/análise , Alanina Transaminase/normas , Catálise , Ensaios Enzimáticos Clínicos/métodos , Ensaios Enzimáticos Clínicos/normas , Humanos , Concentração de Íons de Hidrogênio , Cinética , Valores de Referência , Soluções
3.
Clin Chem Lab Med ; 40(7): 725-33, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12241022

RESUMO

This paper is the fifth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 3.


Assuntos
Aspartato Aminotransferases/análise , Aspartato Aminotransferases/normas , Catálise , Ensaios Enzimáticos Clínicos/métodos , Ensaios Enzimáticos Clínicos/normas , Humanos , Concentração de Íons de Hidrogênio , Indicadores e Reagentes , Cinética , Valores de Referência , Soluções
4.
Clin Chem Lab Med ; 40(7): 734-8, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12241023

RESUMO

This paper is the sixth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 1.


Assuntos
gama-Glutamiltransferase/análise , Catálise , Ensaios Enzimáticos Clínicos/métodos , Ensaios Enzimáticos Clínicos/normas , Humanos , Concentração de Íons de Hidrogênio , Indicadores e Reagentes , Cinética , Valores de Referência , Soluções , gama-Glutamiltransferase/normas
5.
Clin Chem Lab Med ; 40(6): 643-8, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12211663

RESUMO

This paper is the third in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials tamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method (1). Differences are tabulated and commented on in Appendix 1.


Assuntos
Temperatura Corporal , Enzimas/metabolismo , Química Clínica/normas , Humanos , Concentração de Íons de Hidrogênio , Cinética , Controle de Qualidade , Padrões de Referência , Termodinâmica
6.
Clin Chem Lab Med ; 40(6): 635-42, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12211662

RESUMO

This paper is the second in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary reference values is also in preparation. The pro- described 30 degrees C IFCC reference method (1). Differences are tabulated and commented on in Appendix 3.


Assuntos
Temperatura Corporal , Enzimas/metabolismo , Química Clínica/métodos , Química Clínica/normas , Humanos , Concentração de Íons de Hidrogênio , Cinética , Padrões de Referência , Termodinâmica
7.
Clin Chem ; 50(1): 166-74, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14709644

RESUMO

BACKGROUND: The national programs for the harmonization of hemoglobin (Hb)A(1c) measurements in the US [National Glycohemoglobin Standardization Program (NGSP)], Japan [Japanese Diabetes Society (JDS)/Japanese Society of Clinical Chemistry (JSCC)], and Sweden are based on different designated comparison methods (DCMs). The future basis for international standardization will be the reference system developed by the IFCC Working Group on HbA(1c) Standardization. The aim of the present study was to determine the relationships between the IFCC Reference Method (RM) and the DCMs. METHODS: Four method-comparison studies were performed in 2001-2003. In each study five to eight pooled blood samples were measured by 11 reference laboratories of the IFCC Network of Reference Laboratories, 9 Secondary Reference Laboratories of the NGSP, 3 reference laboratories of the JDS/JSCC program, and a Swedish reference laboratory. Regression equations were determined for the relationship between the IFCC RM and each of the DCMs. RESULTS: Significant differences were observed between the HbA(1c) results of the IFCC RM and those of the DCMs. Significant differences were also demonstrated between the three DCMs. However, in all cases the relationship of the DCMs with the RM were linear. There were no statistically significant differences between the regression equations calculated for each of the four studies; therefore, the results could be combined. The relationship is described by the following regression equations: NGSP-HbA(1c) = 0.915(IFCC-HbA(1c)) + 2.15% (r(2) = 0.998); JDS/JSCC-HbA(1c) = 0.927(IFCC-HbA(1c)) + 1.73% (r(2) = 0.997); Swedish-HbA(1c) = 0.989(IFCC-HbA(1c)) + 0.88% (r(2) = 0.996). CONCLUSION: There is a firm and reproducible link between the IFCC RM and DCM HbA(1c) values.


Assuntos
Hemoglobinas Glicadas/análise , Análise Química do Sangue/métodos , Análise Química do Sangue/normas , Calibragem , Hemoglobinas Glicadas/normas , Humanos , Japão , Programas Nacionais de Saúde , Padrões de Referência , Suécia , Estados Unidos
8.
Clin Chem Lab Med ; 40(7): 739-45, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12241024

RESUMO

This paper is the seventh in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase. A document describing the determination of preliminary reference values is also in preparation. The certification of the catalytic activity concentrations as determined by the recently elaborated IFCC primary reference methods at 37 degrees C of four enzyme preparations, namely IRMM/IFCC 452 (gamma-glutamyltransferase), IRMM/IFCC 453 (lactate dehydrogenase 1), IRMM/IFCC 454 (alanine aminotransferase) and IRMM/IFCC 455 (creatine kinase) is described. Homogeneity data were derived from previous results. Stability was assessed using recently obtained data as well as data from previous stability studies. The collaborative study for value assignment was performed under a strict quality control scheme to ensure traceability to the primary reference method. Uncertainty of the materials was assessed in compliance with the Guide to the Expression of Uncertainty in Measurement. The certified values obtained at 37 degrees C are 1.90 microkat/l +/- 0.04 microkat/l (114.1 U/l +/- 2.4 U/l), for gamma-glutamyltransferase, 8.37 microkat/l +/- 0.12 microkat/l (502 U/l +/- 7 U/l), for lactate dehydrogenase 1, 3.09 microkat/l +/- 0.07 microkat/l (186 U/l +/- 4 U/l), for alanine aminotransferase and 1.68 microkat/l +/- 0.07 microkat/l (101 U/l +/- 4 U/l), for creatine kinase. The materials are intended for internal quality control as well as for the evaluation of test systems as required by recent European Union legislation. Furthermore, the materials can be used to transfer accuracy from a reference method to a routine procedure provided the procedures exhibit the same analytical specificity and the certified materials are commutable.


Assuntos
Enzimas/normas , Guias como Assunto , Alanina Transaminase/análise , Alanina Transaminase/normas , Ensaios Enzimáticos Clínicos/métodos , Ensaios Enzimáticos Clínicos/normas , Creatina Quinase/análise , Creatina Quinase/normas , Enzimas/análise , Humanos , L-Lactato Desidrogenase/análise , L-Lactato Desidrogenase/normas , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , gama-Glutamiltransferase/análise , gama-Glutamiltransferase/normas
9.
Clin Chem Lab Med ; 40(6): 631-4, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12211661

RESUMO

This paper is the first in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and with the certification of reference preparations. Other parts deal with: Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic fication of Four Reference Materials for the Determination of Enzymatic Activity of y-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary reference values is also in preparation.


Assuntos
Enzimas/metabolismo , Catálise , Química Clínica/normas , Humanos , Concentração de Íons de Hidrogênio , Cinética , Garantia da Qualidade dos Cuidados de Saúde , Padrões de Referência , Reprodutibilidade dos Testes , Temperatura , Termodinâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA