Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Pediatr Cardiol ; 43(5): 986-994, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34981140

RESUMO

To date, there has been limited investigation of bioabsorbable atrial septal defect (ASD) or patent foramen ovale (PFO) closure devices using clinically relevant large animal models. The purpose of this study is to explore the function and safety of a bioabsorbable ASD occluder (BAO) system for PFO and/or secundum ASD transcatheter closure. Using a sheep model, the intra-atrial septum was evaluated by intracardiac echo (ICE). If a PFO was not present, atrial communication was created via transseptal puncture. Device implantation across the intra-atrial communication was performed with fluoroscopic and ICE guidance. Our 1st generation device consisted of a main structure of thin Poly(L-lactide-co-epsilon-caprolactone) (PLCL) fibers, and an internal Poly glycolic acid (PGA) fabric. Four procedures validated procedure feasibility. Subsequently, device design was modified for improved transcatheter delivery. The 2nd generation device has a two-layered structure and was implanted in six sheep. Results showed procedural success in 9/10 (90%) animals. With deployment, the 1st generation device did not reform into its original disk shape and did not conform nicely along the atrial septum. The 2nd generation device was implanted in six animals, 3 out of 6 survived out to 1 year. At 1 year post implantation, ICE confirmed no residual shunting. By necropsy, biomaterials had partially degraded, and histology of explanted samples revealed significant device endothelialization and biomaterial replacement with a collagen layer. Our results demonstrate that our modified 2nd generation BAO can be deployed via minimally invasive percutaneous transcatheter techniques. The BAO partially degrades over 1 year and is replaced by host native tissues. Future studies are needed prior to clinical trials.


Assuntos
Forame Oval Patente , Comunicação Interatrial , Dispositivo para Oclusão Septal , Implantes Absorvíveis , Animais , Cateterismo Cardíaco/métodos , Seguimentos , Forame Oval Patente/cirurgia , Átrios do Coração , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Humanos , Ovinos , Resultado do Tratamento
2.
Pediatr Cardiol ; 42(3): 654-661, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33403434

RESUMO

We assessed the histological accuracy of X-ray phase-contrast tomography (XPCT) and investigated three-dimensional (3D) ductal tissue distribution in coarctation of the aorta (CoA) specimens. We used nine CoA samples, including the aortic isthmus, ductus arteriosus (DA), and their confluences. 3D images were obtained using XPCT. After scanning, the samples were histologically evaluated using elastica van Gieson (EVG) staining and transcription factor AP-2 beta (TFAP2B) immunostaining. XPCT sectional images clearly depicted ductal tissue distribution as low-density areas. In comparison with EVG staining, the mass density of the aortic wall positively correlated with elastic fiber formation (R = 0.69, P < 0.001). TFAP2B expression was consistent with low-density area including intimal thickness on XPCT images. On 3D imaging, the distances from the DA insertion to the distal terminal of the ductal media and to the intima on the ductal side were 1.63 ± 0.22 mm and 2.70 ± 0.55 mm, respectively. In the short-axis view, the posterior extension of the ductal tissue into the aortic lumen was 79 ± 18% of the diameter of the descending aorta. In three specimens, the aortic wall was entirely occupied by ductal tissue. The ductal intima spread more distally and laterally than the ductal media. The contrast resolution of XPCT images was comparable to that of histological assessment. Based on the 3D images, we conclude that complete resection of intimal thickness, including the opposite side of the DA insertion, is required to eliminate residual ductal tissue and to prevent postoperative re-coarctation.


Assuntos
Aorta Torácica/diagnóstico por imagem , Coartação Aórtica/diagnóstico por imagem , Canal Arterial/diagnóstico por imagem , Aorta Torácica/patologia , Coartação Aórtica/cirurgia , Espessura Intima-Media Carotídea , Canal Arterial/patologia , Humanos , Imageamento Tridimensional/normas , Tomografia Computadorizada por Raios X/normas , Fator de Transcrição AP-2/metabolismo , Raios X
3.
J Card Surg ; 30(6): 532-4, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25854923

RESUMO

Adjusting right ventricle-pulmonary artery shunt flow with placement of hemostatic clips in the Norwood operation is a useful technique for precise control of pulmonary blood flow in the acute postoperative period. This report describes our technique for optimizing right ventricle-pulmonary artery shunt flow with metal clips through a left anterior extrapleural approach, which can be performed safely and minimally invasively without sternal reopening. This procedure may decrease morbidity and contribute to long-term clinical improvement in patients undergoing the Norwood operation.


Assuntos
Ventrículos do Coração/cirurgia , Técnicas Hemostáticas/instrumentação , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos de Norwood/métodos , Artéria Pulmonar/cirurgia , Velocidade do Fluxo Sanguíneo , Ventrículos do Coração/fisiopatologia , Hemodinâmica , Humanos , Síndrome do Coração Esquerdo Hipoplásico/fisiopatologia , Recém-Nascido , Metais , Pleura , Artéria Pulmonar/fisiopatologia
4.
Circ J ; 78(12): 2972-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25342446

RESUMO

BACKGROUND: The importance of ventricular pacing site in pediatric pacemaker therapy has gradually become recognized. We reviewed our experience with a left ventricular (LV)-prioritized pacing strategy. METHODS AND RESULTS: Between 2000 and 2012, 60 patients underwent 76 permanent pacemaker implantations. Eight of the 29 reoperations involved ventricular lead repositioning for pacing-induced ventricular dysfunction. Freedom from ventricular lead failure was 96.3%, 86.8%, and 81.0% at 1, 3, and 5 years, respectively. The independent predictors of ventricular lead failure were age (P=0.026) and peak minimal energy threshold within 6 months (P=0.035). At the measured points, redo bipolar, steroid-eluting leads had significantly better pacing properties than did redo non-steroid-eluting, screw-in leads (P=0.0009-0.03). Ventricular lead repositioning was effective in the 5 patients with systemic LV pacing, whereas its efficacy was inconsistent in patients with single-ventricle or systemic right ventricular (RV) pacing. At a median follow-up of 59 months, the 28 patients with LV pacing had preserved ventricular function (LV fraction shortening, 0.34±0.09). CONCLUSIONS: The outcome of this LV-prioritized pacing strategy in pediatric patients was excellent, demonstrating preserved ventricular function. Bipolar, steroid-eluting, epicardial pacing leads achieved good pacing properties, even in reoperation patients. In children with systemic LV and RV pacing-induced ventricular dysfunction, a conversion to LV apex pacing was an attractive alternative to cardiac resynchronization therapy.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial/métodos , Ventrículos do Coração , Adolescente , Fatores Etários , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Criança , Pré-Escolar , Eletrodos Implantados , Falha de Equipamento , Seguimentos , Cardiopatias Congênitas/complicações , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/mortalidade , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Estimativa de Kaplan-Meier , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/etiologia , Reoperação , Infecções Respiratórias/mortalidade , Estudos Retrospectivos , Esternotomia , Toracotomia , Fatores de Tempo , Adulto Jovem
5.
J Card Surg ; 29(2): 181-5, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24298992

RESUMO

OBJECTIVES: Repair of a postinfarction ventricular septal defect (VSD) is a challenging procedure with a high risk of postoperative residual shunt and subsequent mortality. This retrospective study aimed to assess a modified infarct exclusion technique with a biventricular approach. METHODS: Nineteen consecutive patients who underwent the infarct exclusion procedure for VSD between 2002 and 2011 were reviewed. A biventricular approach (B group: 6 patients) and a left ventricular approach (L group: 13 patients) were studied by univariate analysis. RESULTS: The overall 30-day mortality was 15.8%, and was not different between the two groups (p=0.94). Postoperative residual shunt was not observed in the B group (p=0.21). The overall five-year survival rate was 79%, and there were no late deaths in the B group (p=0.14). CONCLUSION: The repair of postinfarction VSD can be safely performed by the infarct exclusion technique with a biventricular approach. This technique seems to reduce surgical mortality and prevents recurrence of the VSD.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Comunicação Interventricular/etiologia , Comunicação Interventricular/cirurgia , Ventrículos do Coração/cirurgia , Infarto do Miocárdio/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Comunicação Interventricular/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Prevenção Secundária , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
6.
Surg Today ; 44(12): 2385-7, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24197671

RESUMO

A 58-year-old female presenting with congestive heart failure due to a fistula between an aortic false aneurysm and the superior vena cava (SVC) is described. She had a history of Takayasu's arteritis (TA) and she had undergone aortic valve and ascending aorta replacement and coronary artery bypass grafting 6 years before. The false aneurysm had occurred 1 year after the surgery, and she had been conservatively managed. The operation revealed that the cause of the false aneurysm was the detachment of the two proximal saphenous vein anastomoses to the ascending aortic graft. After the surgery, the patient made an uneventful recovery. A false aneurysm of the ascending aorta is one of the most serious complications after replacement of the ascending aorta for patients with TA (Miyata et al. in J Vasc Surg 27:438-445, 1998). We herein present the exceptional case of a fistula between an aortic false aneurysm and the SVC that occurred after ascending aorta graft replacement.


Assuntos
Falso Aneurisma/etiologia , Aorta , Implante de Prótese Vascular , Complicações Pós-Operatórias/etiologia , Arterite de Takayasu/cirurgia , Fístula Vascular/etiologia , Veia Cava Superior , Aorta/cirurgia , Valva Aórtica/cirurgia , Ponte de Artéria Coronária , Feminino , Insuficiência Cardíaca/etiologia , Implante de Prótese de Valva Cardíaca , Humanos , Pessoa de Meia-Idade , Fatores de Tempo
7.
J Am Heart Assoc ; 13(4): e031823, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38353265

RESUMO

BACKGROUND: Perfusion deficits contribute to symptom severity, morbidity, and death in peripheral artery disease (PAD); however, no standard method for quantifying absolute measures of skeletal muscle perfusion exists. This study sought to preclinically test and clinically translate a positron emission tomography (PET) imaging approach using an atherosclerosis-targeted radionuclide, fluorine-18-sodium fluoride (18F-NaF), to quantify absolute perfusion in PAD. METHODS AND RESULTS: Eight Yorkshire pigs underwent unilateral femoral artery ligation and dynamic 18F-NaF PET/computed tomography imaging on the day of and 2 weeks after occlusion. Following 2-week imaging, calf muscles were harvested to quantify microvascular density. PET methodology was validated with microspheres in 4 additional pig studies and translated to patients with PAD (n=39) to quantify differences in calf perfusion across clinical symptoms/stages and perfusion responses in a case of revascularization. Associations between PET perfusion, ankle-brachial index, toe-brachial index, and toe pressure were assessed in relation to symptoms. 18F-NaF PET/computed tomography quantified significant deficits in calf perfusion in pigs following arterial occlusion and perfusion recovery 2 weeks after occlusion that coincided with increased muscle microvascular density. Additional studies confirmed that PET-derived perfusion measures agreed with microsphere-derived perfusion measures. Translation of imaging methods demonstrated significant decreases in calf perfusion with increasing severity of PAD and quantified perfusion responses to revascularization. Perfusion measures were also significantly associated with symptom severity, whereas traditional hemodynamic measures were not. CONCLUSIONS: 18F-NaF PET imaging quantifies perfusion deficits that correspond to clinical stages of PAD and represents a novel perfusion imaging strategy that could be partnered with atherosclerosis-targeted 18F-NaF PET imaging using a single radioisotope injection. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03622359.


Assuntos
Músculo Esquelético , Doença Arterial Periférica , Animais , Humanos , Músculo Esquelético/diagnóstico por imagem , Perfusão , Doença Arterial Periférica/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Fluoreto de Sódio , Suínos
8.
JTCVS Open ; 15: 433-445, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37808023

RESUMO

Objectives: Palliative treatment of cyanotic congenital heart disease (CCHD) uses systemic-to-pulmonary conduits, often a modified Blalock-Taussig-Thomas shunt (mBTTs). Expanded polytetrafluoroethylene (ePTFE) mBTTs have associated risks for thrombosis and infection. The Human Acellular Vessel (HAV) (Humacyte, Inc) is a decellularized tissue-engineered blood vessel currently in clinical trials in adults for vascular trauma, peripheral artery disease, and end-stage renal disease requiring hemodialysis. In addition to restoring blood flow, the engineered HAV demonstrates the capacity for host cellular remodeling into native-like vasculature. Here we report preclinical evaluation of a small-diameter (3.5 mm) HAV as a mBTTs in a non-human primate model. Methods: We implanted 3.5 mm HAVs as right subclavian artery to pulmonary artery mBTTs in non-immunosuppressed juvenile rhesus macaques (n = 5). HAV patency, structure, and blood flow were assessed by postoperative imaging from 1 week to 6 months. Histology of HAVs and surrounding tissues was performed. Results: Surgical procedures were well tolerated, with satisfactory anastomoses, showing feasibility of using the 3.5 mm HAV as a mBTTs. All macaques had some immunological reactivity to the human extracellular matrix, as expected in this xenogeneic model. HAV mBTTs remained patent for up to 6 months in animals, exhibiting mild immunoreactivity. Two macaques displaying more severe immunoreactivity to the human HAV material developed midgraft dilatation without bleeding or rupture. HAV repopulation by host cells expressing smooth muscle and endothelial markers was observed in all animals. Conclusions: These findings may support use of 3.5 mm HAVs as mBTTs in CCHD and potentially other pediatric vascular indications.

9.
Expert Opin Biol Ther ; 22(3): 433-440, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34427482

RESUMO

INTRODUCTION: Cardiovascular disease (CVD) is the leading cause of death in western countries. Although surgical outcomes for CVD are dramatically improving with the development of surgical techniques, medications, and perioperative management strategies, adverse postoperative events related to the use of artificial prosthetic materials are still problematic. Moreover, in pediatric patients, using these artificial materials make future re-intervention inevitable due to their lack of growth potential. AREAS COVERED: This review focuses on the most current tissue-engineering (TE) technologies to treat cardiovascular diseases and discusses their limitations through reports ranging from animal studies to clinical trials. EXPERT OPINION: Tissue-engineered structures, derived from a patient's own autologous cells/tissues and biodegradable polymer scaffolds, can provide mechanical function similar to non-diseased tissue. However, unlike prosthetic materials, tissue-engineered structures are hypothetically more biocompatible and provide growth potential, saving patients from additional or repetitive interventions. While there are many methods being investigated to develop TE technologies in the hopes of finding better options to tackle CVD, most of these approaches are not ready for clinical use or trials. However, tissue engineering has great promise to potentially provide better treatment options to vastly improve cardiovascular surgical outcomes.


Assuntos
Doenças Cardiovasculares , Engenharia Tecidual , Animais , Prótese Vascular , Doenças Cardiovasculares/cirurgia , Criança , Humanos , Polímeros , Engenharia Tecidual/métodos , Alicerces Teciduais , Transplante Autólogo
10.
Commun Med (Lond) ; 2: 3, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35603301

RESUMO

Background: Tissue-engineered vascular grafts (TEVGs) have the potential to advance the surgical management of infants and children requiring congenital heart surgery by creating functional vascular conduits with growth capacity. Methods: Herein, we used an integrative computational-experimental approach to elucidate the natural history of neovessel formation in a large animal preclinical model; combining an in vitro accelerated degradation study with mechanical testing, large animal implantation studies with in vivo imaging and histology, and data-informed computational growth and remodeling models. Results: Our findings demonstrate that the structural integrity of the polymeric scaffold is lost over the first 26 weeks in vivo, while polymeric fragments persist for up to 52 weeks. Our models predict that early neotissue accumulation is driven primarily by inflammatory processes in response to the implanted polymeric scaffold, but that turnover becomes progressively mechano-mediated as the scaffold degrades. Using a lamb model, we confirm that early neotissue formation results primarily from the foreign body reaction induced by the scaffold, resulting in an early period of dynamic remodeling characterized by transient TEVG narrowing. As the scaffold degrades, mechano-mediated neotissue remodeling becomes dominant around 26 weeks. After the scaffold degrades completely, the resulting neovessel undergoes growth and remodeling that mimicks native vessel behavior, including biological growth capacity, further supported by fluid-structure interaction simulations providing detailed hemodynamic and wall stress information. Conclusions: These findings provide insights into TEVG remodeling, and have important implications for clinical use and future development of TEVGs for children with congenital heart disease.

11.
Ann Thorac Surg ; 111(4): 1234-1241, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32946845

RESUMO

BACKGROUND: Small diameter (<6 mm), bioabsorbable, arterial, tissue-engineered vascular grafts (TEVGs) remain limited by thromboembolism. The objective of this study was to test whether heparin-eluting (HE) TEVGs prevent early thrombosis in a large animal model. METHODS: TEVGs were created with an outer poly-ε-caprolactone electrospun nanofiber layer, with a 15-µm average pore size and an inner layer composed of a 50:50 poly(L-lactide-co-ε-caprolactone) copolymer. Adult female sheep (n = 5) underwent bilateral carotid artery interposition grafting, with a control TEVG in 1 carotid artery and an HE TEVG in the contralateral position. Animals were followed for 8 weeks with weekly Duplex ultrasonography to monitor TEVG performance. RESULTS: All sheep survived to the designated endpoint. At 8 weeks all 5 HE TEVGs were patent. Three of 5 control TEVGs had early thrombotic occlusion at <1 week. More than 97% of heparin release occurred within the first 24 hours. Histologic evaluation of the HE TEVG displayed cellularity like a native carotid artery with no evidence of calcification. Significantly fewer platelets adhered to the HE TEVG than to the control TEVG (P < .001). CONCLUSIONS: This study suggests HE TEVGs prevent acute graft thrombosis. We hypothesize that the HE properties of the HE TEVG during vascular endothelialization is useful for maintaining TEVG patency. This technique may aid in the translation of small arterial TEVGs to the clinic.


Assuntos
Implante de Prótese Vascular/métodos , Prótese Vascular , Artérias Carótidas/cirurgia , Heparina/farmacologia , Engenharia Tecidual/métodos , Alicerces Teciduais , Animais , Anticoagulantes/farmacologia , Feminino , Modelos Animais , Desenho de Prótese , Ovinos
12.
Acta Biomater ; 115: 176-184, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32822820

RESUMO

To date, there has been little investigation of biodegradable tissue engineered arterial grafts (TEAG) using clinically relevant large animal models. The purpose of this study is to explore how pore size of electrospun scaffolds can be used to balance neoarterial tissue formation with graft structural integrity under arterial environmental conditions throughout the remodeling process. TEAGs were created with an outer poly-ε-caprolactone (PCL) electrospun layer and an inner sponge layer composed of heparin conjugated 50:50 poly (l-lactide-co-ε-caprolactone) copolymer (PLCL). Outer electrospun layers were created with four different pore diameters (4, 7, 10, and 15 µm). Fourteen adult female sheep underwent bilateral carotid artery interposition grafting (n = 3-4 /group). Our heparin-eluting TEAG was implanted on one side (n = 14) and ePTFE graft (n = 3) or non-heparin-eluting TEAG (n = 5) on the other side. Twelve of the fourteen animals survived to the designated endpoint at 8 weeks, and one animal with 4 µm pore diameter graft was followed to 1 year. All heparin-eluting TEAGs were patent, but those with pore diameters larger than 4 µm began to dilate at week 4. Only scaffolds with a pore diameter of 4 µm resisted dilation and could do so for up to 1 year. At 8 weeks, the 10 µm pore graft had the highest density of cells in the electrospun layer and macrophages were the primary cell type present. This study highlights challenges in designing bioabsorbable TEAGs for the arterial environment in a large animal model. While larger pore diameter TEAGs promoted cell infiltration, neotissue could not regenerate rapidly enough to provide sufficient mechanical strength required to resist dilation. Future studies will be focused on evaluating a smaller pore design to better understand long-term remodeling and determine feasibility for clinical use. STATEMENT OF SIGNIFICANCE: In situ vascular tissue engineering relies on a biodegradable scaffold that encourages tissue regeneration and maintains mechanical integrity until the neotissue can bear the load. Species-specific differences in tissue regeneration and larger mechanical forces often result in graft failure when scaling up from small to large animal models. This study utilizes a slow-degrading electrospun PCL sheath to reinforce a tissue engineered arterials graft. Pore size, a property critical to tissue regeneration, was controlled by changing PCL fiber diameter and the resulting effects of these properties on neotissue formation and graft durability was evaluated. This study is among few to report the effect of pore size on vascular neotissue formation in a large animal arterial model and also demonstrate robust neotissue formation.


Assuntos
Poliésteres , Engenharia Tecidual , Animais , Prótese Vascular , Artérias Carótidas , Feminino , Heparina , Modelos Animais , Ovinos , Alicerces Teciduais
13.
Ann Thorac Surg ; 110(6): 2088-2095, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32246933

RESUMO

BACKGROUND: To improve survival of patients with hypoplastic left heart syndrome, combination therapy with bilateral pulmonary artery banding and prostaglandin E1 (PGE1)-mediated ductal patency was developed as an alternative for high-risk neonates in Japan. However, the effect of long-term PGE1 administration on ductus arteriosus remains unclear. Synchrotron radiation-based X-ray phase-contrast tomography (XPCT) enables clear visualization of soft tissues at an approximate spatial resolution of 12.5 µm. We aimed to investigate morphologic changes in ductus arteriosus after long-term PGE1 infusion using XPCT. METHODS: Seventeen ductus arteriosus tissue samples from patients with hypoplastic left heart syndrome were obtained during the Norwood procedure. The median duration of lipo-prostaglandin E1 (lipo-PGE1) administration was 48 days (range, 3 to 123). Structural analysis of ductus arteriosus was performed and compared with conventional histologic analysis. RESULTS: The XPCT was successfully applied to quantitative measurements of ductal media. Significant correlation was found between the duration of lipo-PGE1 infusion and mass density of ductal media (R = 0.723, P = .001). The duration of lipo-PGE1 administration was positively correlated with elastic fiber staining (R = 0.799, P < .001) and negatively correlated with smooth muscle formation (R = -0.83, P < .001). No significant increase in intimal cushion formation was found after long-term lipo-PGE1 administration. Expression of ductus arteriosus dominant PGE2-receptor EP4 almost disappeared in specimens when lipo-PGE1 was administered over 3 days. CONCLUSIONS: Disorganized elastogenesis and little intimal cushion formation after long-term lipo-PGE1 administration suggest that ductus arteriosus remodeled to the elastic artery phenotype. Because EP4 was downregulated and ductus arteriosus exhibited elastic characteristics, the dosage of lipo-PGE1 might be decreased after a definite administration period.


Assuntos
Alprostadil/administração & dosagem , Canal Arterial/efeitos dos fármacos , Síndrome do Coração Esquerdo Hipoplásico/terapia , Vasodilatadores/administração & dosagem , Estudos de Coortes , Esquema de Medicação , Canal Arterial/diagnóstico por imagem , Elasticidade , Feminino , Humanos , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico por imagem , Recém-Nascido , Masculino , Tomografia Computadorizada por Raios X
15.
Ann Thorac Surg ; 107(3): e227-e228, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30278170

RESUMO

Extracorporeal membrane oxygenation through cervical cannulation is an established option for pediatric patients with acute cardiopulmonary failure. However, left-sided heart decompression is sometimes mandatory in patients with severe left ventricular dysfunction. This report describes a fast and less invasive technique for placing a left atrial cannula through a left anterior minithoracotomy approach. In 4 critically ill children, this minimally invasive technique provided satisfactory left-sided heart decompression, and this report describes a representative case.


Assuntos
Descompressão Cirúrgica/métodos , Oxigenação por Membrana Extracorpórea/métodos , Átrios do Coração/cirurgia , Insuficiência Cardíaca/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Miocardite/complicações , Toracotomia/métodos , Doença Aguda , Criança , Ecocardiografia , Seguimentos , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Coração Auxiliar , Humanos , Masculino , Miocardite/diagnóstico , Miocardite/fisiopatologia , Volume Sistólico/fisiologia
16.
Ann Thorac Surg ; 101(2): 764-6, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26777937

RESUMO

The combination of aortic atresia and interrupted aortic arch is a rare condition. We describe a case of Norwood operation for this defect, in which a collateral artery from the descending aorta supplied coronary perfusion. The devised cardiopulmonary bypass technique is discussed, in which the left subclavian artery perfusion was utilized in addition to the cannulation to the descending aorta to secure the cerebral perfusion.


Assuntos
Anormalidades Múltiplas/cirurgia , Aorta Torácica/anormalidades , Aorta Torácica/cirurgia , Valva Aórtica/anormalidades , Valva Aórtica/cirurgia , Ponte Cardiopulmonar , Procedimentos de Norwood/métodos , Artéria Subclávia/fisiologia , Humanos , Recém-Nascido , Fluxo Sanguíneo Regional
17.
World J Pediatr Congenit Heart Surg ; 7(6): 700-705, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27834761

RESUMO

BACKGROUND: The feasibility of synchrotron radiation-based phase-contrast computed tomography (PCCT) for visualization of the atrioventricular (AV) conduction axis in human whole heart specimens was tested using four postmortem structurally normal newborn hearts obtained at autopsy. METHODS: A PCCT imaging system at the beamline BL20B2 in a SPring-8 synchrotron radiation facility was used. The PCCT imaging of the conduction system was performed with "virtual" slicing of the three-dimensional reconstructed images. For histological verification, specimens were cut into planes similar to the PCCT images, then cut into 5-µm serial sections and stained with Masson's trichrome. RESULTS: In PCCT images of all four of the whole hearts of newborns, the AV conduction axis was distinguished as a low-density structure, which was serially traceable from the compact node to the penetrating bundle within the central fibrous body, and to the branching bundle into the left and right bundle branches. This was verified by histological serial sectioning. CONCLUSION: This is the first demonstration that visualization of the AV conduction axis within human whole heart specimens is feasible with PCCT.


Assuntos
Arritmias Cardíacas/diagnóstico , Meios de Contraste/farmacologia , Sistema de Condução Cardíaco/diagnóstico por imagem , Coração/diagnóstico por imagem , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Cadáver , Estudos de Viabilidade , Humanos , Lactente , Recém-Nascido
18.
Interact Cardiovasc Thorac Surg ; 20(5): 685-6, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25662960

RESUMO

Although innominate artery transection for innominate artery compression of the trachea is recently used for prevention of life-threatening complications (e.g. massive bleeding and obstructive apnoea) in patients with neurological disorders, pre-existing tracheostomy poses a risk of mediastinal infection with sternotomy. We successfully performed innominate artery transection on such a patient via the left anterior extrapleural approach without sternotomy after confirming the anatomical configuration on three-dimensional multidetector row computed tomography angiography.


Assuntos
Tronco Braquiocefálico/cirurgia , Imageamento Tridimensional , Insuficiência Respiratória/cirurgia , Toracotomia/métodos , Traqueostomia/efeitos adversos , Procedimentos Cirúrgicos Vasculares/métodos , Obstrução das Vias Respiratórias/prevenção & controle , Angiografia/métodos , Traumatismos do Nascimento/complicações , Traumatismos do Nascimento/diagnóstico , Traumatismos do Nascimento/terapia , Tronco Braquiocefálico/diagnóstico por imagem , Criança , Serviço Hospitalar de Emergência , Seguimentos , Humanos , Hipóxia-Isquemia Encefálica/complicações , Hipóxia-Isquemia Encefálica/diagnóstico , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Doenças do Sistema Nervoso/complicações , Doenças do Sistema Nervoso/diagnóstico , Posicionamento do Paciente , Pleura/cirurgia , Respiração Artificial/efeitos adversos , Respiração Artificial/métodos , Insuficiência Respiratória/diagnóstico por imagem , Insuficiência Respiratória/etiologia , Infecção da Ferida Cirúrgica/prevenção & controle , Fatores de Tempo , Tomografia Computadorizada por Raios X/métodos , Traqueostomia/métodos , Resultado do Tratamento
19.
World J Pediatr Congenit Heart Surg ; 6(3): 458-61, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26180165

RESUMO

Persistent respiratory symptoms often occur after surgical repair of double aortic arch (DAA). Most often, symptoms are relatively mild and tend to be self-limited and improve with growth. Multidetector computed tomography (MDCT) imaging can be used to obtain needed anatomic information regarding the potential for extrinsic airway compression and is minimally invasive, safe, and readily available after surgery. We herein report the cases of two patients with persistent airway symptoms after surgical therapy for a double aortic arch. One of the patients eventually required aortopexy in order to achieve complete relief from recurrent symptoms of airway compression. In the other case, wheezing persisted following surgical division of the vascular ring, but it resolved over time without further intervention. In both cases, serial follow-up imaging with computed tomography scans was informative and helped guide management decisions.


Assuntos
Aorta Torácica/anormalidades , Complicações Pós-Operatórias , Tomografia Computadorizada por Raios X/métodos , Estenose Traqueal/etiologia , Malformações Vasculares/cirurgia , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Aorta Torácica/cirurgia , Seguimentos , Humanos , Recém-Nascido , Masculino , Estenose Traqueal/diagnóstico por imagem
20.
Ann Thorac Surg ; 99(5): e117-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25952245

RESUMO

Congenitally absent aortic valve is an extremely rare and fatal cardiac malformation. We report the case of a neonate with absent aortic valve, an interrupted aortic arch, and a normal-sized left ventricle. At age 9 hours, emergency aortic valve closure and a Norwood procedure were performed to maintain coronary circulation. The patient's postoperative course was complicated because of tracheomalacia and a severely dilated aorta that were treated with reduction aortoplasty at age 4 months. Finally, a staged Yasui procedure was performed at 26 months. To our knowledge, this is the first report of a successful biventricular repair for absent aortic valve.


Assuntos
Valva Aórtica/anormalidades , Valva Aórtica/cirurgia , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Humanos , Recém-Nascido , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA