1.
Bioelectromagnetics ; 44(1-2): 5-16, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36786477

RESUMO

Previous research has shown that virus infectivity can be dramatically reduced by radio frequency exposure in the gigahertz (GHz) frequency range. Given the worldwide SARS-CoV-2 pandemic, which has caused over 1 million deaths and has had a profound global economic impact, there is a need for a noninvasive technology that can reduce the transmission of virus among humans. RF is a potential wide area-of-effect viral decontamination technology that could be used in hospital rooms where patients are expelling virus, in grocery and convenience stores where local populations mix, and in first responder settings where rapid medical response spans many potentially infected locations within hours. In this study, we used bovine coronavirus (BCoV) as a surrogate of SARS-CoV-2 and exposed it to high peak power microwave (HPPM) pulses at four narrowband frequencies: 2.8, 5.6, 8.5, and 9.3 GHz. Exposures consisted of 2 µs pulses delivered at 500 Hz, with pulse counts varied by decades between 1 and 10,000. The peak field intensities (i.e. the instantaneous power density of each pulse) ranged between 0.6 and 6.5 MW/m2 , depending on the microwave frequency. The HPPM exposures were delivered to plastic coverslips containing BCoV dried on the surface. Hemagglutination (HA) and cytopathic effect analyses were performed 6 days after inoculation of host cells to assess viral infectivity. No change in viral infectivity was seen with increasing dose (pulse number) across the tested frequencies. Under all conditions tested, exposure did not reduce infectivity more than 1.0 log10. For the conditions studied, high peak power pulsed RF exposures in the 2-10 GHz range appear ineffective as a virucidal approach for hard surface decontamination. © 2023 Bioelectromagnetics Society.


Assuntos
COVID-19 , Inativação de Vírus , Animais , Bovinos , Humanos , SARS-CoV-2 , Micro-Ondas
2.
Bioelectromagnetics ; 43(1): 14-24, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34719046

RESUMO

Biological effects in the microwave band of the radiofrequency (RF) spectrum are thermally mediated. For acute high-power microwave exposures, these effects will depend on transient time-temperature histories within the tissue. In this article, we summarize the transient temperature response of rats exposed to RF energy emanating from an open-ended rectangular waveguide. These exposures produced specific absorption rates of approximately 36 and 203 W/kg in the whole body and brain, respectively. We then use the experimentally measured thermal data to infer the baseline perfusion rate in the brain and modify a custom thermal modeling tool based upon these findings. Finally, we compare multi-physics simulations of rat brain temperature against empirical measurements in both live and euthanized subjects and find close agreement between model and experimentation. This research revealed that baseline brain perfusion rates in rat subjects could be larger than previously assumed in the RF thermal modeling literature, and plays a significant role in the transient thermal response to high-power microwave exposures. © 2021 Bioelectromagnetics Society.


Assuntos
Temperatura Corporal , Encéfalo/efeitos da radiação , Ondas de Rádio , Animais , Micro-Ondas/efeitos adversos , Ondas de Rádio/efeitos adversos , Ratos , Temperatura
3.
Sci Rep ; 13(1): 9800, 2023 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-37328590

RESUMO

Inactivation of influenza A virus by radiofrequency (RF) energy exposure at levels near Institute of Electrical and Electronics Engineers (IEEE) safety thresholds has been reported. The authors hypothesized that this inactivation was through a structure-resonant energy transfer mechanism. If this hypothesis is confirmed, such a technology could be used to prevent transmission of virus in occupied public spaces where RF irradiation of surfaces could be performed at scale. The present study aims to both replicate and expand the previous work by investigating the neutralization of bovine coronavirus (BCoV), a surrogate of SARS-CoV-2, by RF radiation in 6-12 GHz range. Results showed an appreciable reduction in BCoV infectivity (up to 77%) due to RF exposure to certain frequencies, but failed to generate enough reduction to be considered clinically significant.


Assuntos
COVID-19 , Coronavirus Bovino , Animais , Bovinos , Humanos , SARS-CoV-2 , Ondas de Rádio/efeitos adversos , Inativação de Vírus
4.
Health Phys ; 119(2): 206-215, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-33290003

RESUMO

A previous study reported thermal effects resulting from millimeter wave exposures at 35 and 94 GHz on non-human primates, specifically rhesus monkeys' (Macaca mulatta) corneas, but the data exhibited large variations in the observed temperatures and uncertainties in the millimeter wave dosimetry. By incorporating improvements in models and dosimetry, a non-human primate experiment was conducted involving corneal exposures that agreed well with a three-layer, one-dimensional, thermodynamic model to predict the expected surface temperature rise. The new data indicated that the originally reported safety margins for eye exposures were underestimated by 41 ± 20% over the power densities explored. As a result, the expected minimal visible lesion thresholds should be raised to 10.6 ± 1.5 and 7.1 ± 1.0 J cm at 35 and 94 GHz, respectively, provided that the power density is less than 6 W cm for subjects that are unable to blink. If the blink reflex was active, a power density threshold of 20 W cm could be used to protect the eye, although the eyelid could be burned if the exposure was long enough.


Assuntos
Córnea/efeitos da radiação , Fenômenos Fisiológicos Oculares/efeitos dos fármacos , Algoritmos , Animais , Temperatura Corporal , Simulação por Computador , Relação Dose-Resposta à Radiação , Células Epiteliais/efeitos da radiação , Macaca mulatta , Micro-Ondas , Modelos Teóricos , Doses de Radiação , Exposição à Radiação , Ondas de Rádio , Radiometria , Pele/citologia , Fatores de Tempo