Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Infect Dis ; 23(1): 539, 2023 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-37596519

RESUMO

BACKGROUND: The COVID-19 pandemic has spread very rapidly around the world. Various regional and national lockdowns were imposed to control the spread. Meanwhile, vaccine development and population vaccination were the next steps for pandemic control. Workers in the dental field, both dentists and dental assistants, however, were close to the sources of aerosol generated during dental procedures and thus were the group of workers the most exposed to COVID-19 infection. The aim of our study was to monitor the immune response before and after the vaccine in a high-risk population, composed by dental professionals. METHODS: A clinical prospective study was carried out among dental professionals at the Academic Dental Polyclinic, Wroclaw Medical University (Wroclaw, Lower Silesia region, Poland). Blood samples were collected at an interval of one year - March/April 2020, before the vaccination against COVID-19, and April 2021, after the vaccination. The analysis was performed on serum with four different methods: qualitative, semi-quantitative, and quantitative IgG count for SARS-CoV-2, and SARS-CoV-2 neutralizing antibodies. RESULTS: A total of 42 healthy adult volunteers participated in the study. The results showed a statistically significant difference (p < 0.05) in antibody levels before and after vaccination (1st and 2nd measurement) for each test method. The tests that were used affected the results and the test that showed the strongest relationship with the result was the Qualitative test. CONCLUSIONS: Dental professionals are the adult working population most at risk for COVID-19. Monitoring SARS-CoV-2-status-related seropositivity can provide useful information occupational risk factors for dental professionals.


Assuntos
COVID-19 , Adulto , Humanos , Estudos Prospectivos , COVID-19/epidemiologia , COVID-19/prevenção & controle , Pandemias , SARS-CoV-2 , Controle de Doenças Transmissíveis , Vacinação , Imunoglobulina G , Anticorpos Antivirais , Odontólogos
2.
Int J Mol Sci ; 24(4)2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36835015

RESUMO

Chemical composition and physical parameters of the implant surface, such as roughness, regulate the cellular response leading to implant bone osseointegration. Possible implant surface modifications include anodization or the plasma electrolytic oxidation (PEO) treatment process that produces a thick and dense oxide coating superior to normal anodic oxidation. Experimental modifications with Plasma Electrolytic Oxidation (PEO) titanium and titanium alloy Ti6Al4V plates and PEO additionally treated with low-pressure oxygen plasma (PEO-S) were used in this study to evaluate their physical and chemical properties. Cytotoxicity of experimental titanium samples as well as cell adhesion to their surface were assessed using normal human dermal fibroblasts (NHDF) or L929 cell line. Moreover, the surface roughness, fractal dimension analysis, and texture analysis were calculated. Samples after surface treatment have substantially improved properties compared to the reference SLA (sandblasted and acid-etched) surface. The surface roughness (Sa) was 0.59-2.38 µm, and none of the tested surfaces had cytotoxic effect on NHDF and L929 cell lines. A greater cell growth of NHDF was observed on the tested PEO and PEO-S samples compared to reference SLA sample titanium.


Assuntos
Implantes Dentários , Humanos , Propriedades de Superfície , Titânio/química , Teste de Materiais , Osseointegração/fisiologia
3.
Med Sci Monit ; 26: e920513, 2020 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-32078588

RESUMO

BACKGROUND Peri-implantitis is an inflammatory reaction affecting both hard and soft tissues surrounding dental implants. This pathological condition is caused by a polymicrobial aggressive biofilm that colonizes the implant and abutment surface at the peri-implant crevice level. The present in vitro study evaluated different methods of implant surface decontamination and assessed whether the type of the implant surface influences the results. MATERIAL AND METHODS The study was conducted in an in vitro model of peri-implantitis using 30 implants. The implants were divided into 3 equal groups based on the surface characteristics: machined-surface, sand-blasted and acid-etched, and HA-coated. Implants were coated with E. coli biofilm. After an incubation period, they were decontaminated with 4 different methods: sonic scaler application, sonic scaler application with the chemical agent Perisolv® combination, Er: YAG laser treatment, and PDT therapy with methylene blue as a photosensitizer. RESULTS The highest level of decontamination was achieved for machined-surface implants and for the combined chemical-mechanical and Er: YAG laser treatment. CONCLUSIONS The results of our study suggest that the method of implant decontamination should be customized to the type of implant surface.


Assuntos
Anti-Infecciosos/farmacologia , Descontaminação/métodos , Implantes Dentários/microbiologia , Biofilmes/efeitos dos fármacos , Durapatita/química , Escherichia coli/efeitos dos fármacos , Escherichia coli/fisiologia , Lasers de Estado Sólido , Fármacos Fotossensibilizantes/farmacologia , Propriedades de Superfície
4.
Pol J Pathol ; 65(1): 48-54, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25119009

RESUMO

Nuclear ubiquitous casein and cyclin-dependent kinases substrate (NUCKS) is a chromosomal protein of unknown function. Its amino acid composition and structure of its DNA binding domain resemble those of high mobility group A (HMGA) proteins which are associated with various malignancies. Since changes in expression of HMGA are considered as a marker of tumor progression, it is possible that similar changes in expression of NUCKS could be a useful tool in diagnosis of malignant skin tumors. To investigate this assumption we used specific antibodies against NUCKS for immunohistochemistry of squamous (SCC) and basal cell carcinoma (BCC) as well as keratoacanthoma (KA). We found high expression of NUCKS in nuclei of SCC and BCC cells which exceeded expression of the well-known proliferation marker Ki67. Expression of NUCKS in benign KA was much below that of malignant tumors. With the present study and based on our previous experience we would like to suggest the NUCKS protein as a novel proliferation marker for immunohistochemical evaluation of formalin-fixed and paraffin-embedded skin tumor specimens. We would like to emphasize that NUCKS abundance in malignant skin tumors is higher than that of the well-known proliferation marker Ki67, thus allowing more precise assessment of tumor proliferation potential.


Assuntos
Carcinoma Basocelular/metabolismo , Carcinoma de Células Escamosas/metabolismo , Antígeno Ki-67/metabolismo , Proteínas Nucleares/metabolismo , Fosfoproteínas/metabolismo , Neoplasias Cutâneas/metabolismo , Biomarcadores Tumorais/metabolismo , Carcinoma Basocelular/patologia , Carcinoma de Células Escamosas/patologia , Núcleo Celular/enzimologia , Humanos , Neoplasias Cutâneas/patologia
5.
Biomedicines ; 11(5)2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37238944

RESUMO

The development of polymer matrices as dental drug carriers takes into account the following technological aspects of the developed formulations: the composition and the technology used to manufacture them, which affect the properties of the carriers, as well as the testing methods for assessing their behavior at application sites. The first part of this paper characterizes the methods for fabricating dental drug carriers, i.e., the solvent-casting method (SCM), lyophilization method (LM), electrospinning (ES) and 3D printing (3DP), describing the selection of technological parameters and pointing out both the advantages of using the mentioned methods and their limitations. The second part of this paper describes testing methods to study the formulation properties, including their physical and chemical, pharmaceutical, biological and in vivo evaluation. Comprehensive in vitro evaluation of carrier properties permits optimization of formulation parameters to achieve prolonged retention time in the dynamic oral environment and is essential for explaining carrier behavior during clinical evaluation, consequently enabling the selection of the optimal formulation for oral application.

6.
Polymers (Basel) ; 15(7)2023 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-37050388

RESUMO

Three-dimensional printing is finding increasing applications in today's world. Due to the accuracy and the possibility of rapid production, the CAD/CAM (computer-aided design/computer-aided manufacturing) technology has become the most desired approach in the preparation of elements, especially in medicine and dentistry. This study aimed to compare the biomechanical properties, fractal dimension (FD), and texture of three selected materials used for 3D printing in dentistry. Three biomaterials used in 3D printing were evaluated. The materials were subjected to the compression test. Then, their mechanical features, FD, and texture were analyzed. All the tested materials showed different values for the studied properties. The only statistically insignificant difference was observed for the force used in the compression test. All three materials showed differences in width and height measurements. The difference in the decrease between the compression plates was also significant. For Dental LT Clear, the mean value was 0.098 mm (SD = 0.010), while for BioMed Amber it was 0.059 mm (SD = 0.019), and for IBT it was 0.356 mm (SD = 0.015). The nominal strain also differed between the materials. IBT had the highest mean value (7.98), while BioMed Amber had the smallest (1.31). FD analysis revealed that Dental LT Clear did not show differences in the structure of the material. The other two materials showed significant changes after the compression test. Texture analysis (TA) revealed similar results: BioMed Amber resin showed significantly less pronounced texture changes compared to the other two materials. BioMed Amber also showed the most stable mechanical properties, whereas those of IBT changed the most. Fractal analysis revealed that IBT showed significant differences from the other two materials, whereas TA showed that only Dental LT Clear did not show changes in its texture after the compression test. Before the compression, however, BioMed Amber differed the most when bone index was taken into account.

7.
Med Sci Monit ; 18(2): PI5-9, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22293891

RESUMO

BACKGROUND: Common skin tumors like basal- and squamous-cell carcinoma present a serious problem in modern medicine. Exposure to ultraviolet solar radiation is the main cause of these lesions. Since application of Aldara and PDT separately is well documented, we decided to use both methods together. The aim of our study was to evaluate the effectiveness of local photodynamic therapy supplemented with topical application of Aldara in basal-cell carcinoma. MATERIAL/METHODS: Thirty-four patients ages 50 to 68 years were enrolled to the trial and underwent PDT treatment. Each case of BCC was histopathologically confirmed. Ten patients were subjected to local Levulan-PDT and placebo (Eucerin as vehicle cream), and 24 patients were subjected to Levulan-PDT and imiquimod. Photodynamic diagnosis (PDD) was used to detect and visualize suspicious foci (including cancer lesions). RESULTS: In the group of patients who were treated using Levulan-PDT and placebo, 6 patients (60%) were totally cured and 4 lesions (40%) significantly decreased in size. In the group of patients treated with Levulan-PDT and imiquimod, 18 lesions totally disappeared (75%), 6 lesions significantly diminished, and in 1 patient small foci of previously excised BCC developed again in scar tissue 10 month after the first control examination. CONCLUSIONS: Cure was achieved without any scarring and with very good cosmetic effects. Although this is the preliminary report, the presented modification of PDT seems to be reasonable and promising in treating basal-cell carcinoma.


Assuntos
Ácido Aminolevulínico/uso terapêutico , Carcinoma Basocelular/tratamento farmacológico , Fotoquimioterapia , Fármacos Fotossensibilizantes/uso terapêutico , Neoplasias Cutâneas/tratamento farmacológico , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia
8.
J Clin Med ; 11(9)2022 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-35566634

RESUMO

The differential diagnosis of benign nevi (BN), dysplastic nevi (DN), and melanomas (MM) represents a considerable clinical problem. These lesions are similar in clinical examination but have different prognoses and therapeutic management techniques. A texture analysis (TA) is a mathematical and statistical analysis of pixel patterns of a digital image. This study aims to demonstrate the relationship between the TA of digital images of pigmented lesions under polarized and non-polarized light and their histopathological diagnosis. Ninety pigmented lesions of 76 patients were included in this study. We obtained 166 regions of interest (ROI) images for MM, 166 for DN, and 166 for BN. The pictures were taken under polarized and non-polarized light. Selected image texture features (entropy and difference entropy and long-run emphasis) of ROIs were calculated. Those three equations were used to construct the texture index (TI) and bone index (BI). All of the presented features distinguish melanomas, benign and dysplastic lesions under polarized light very well. In non-polarized images, only the long-run emphasis moment and both indices effectively differentiated nevi from melanomas. TA is an objective method of assessing pigmented lesions and can be used in automatic diagnostic systems.

9.
Life (Basel) ; 12(7)2022 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-35888097

RESUMO

Clinical diagnosis of pigmented lesions can be a challenge in everyday practice. Benign and dysplastic nevi and melanomas may have similar clinical presentations, but completely different prognoses. Fractal dimensions of shape and texture can describe the complexity of the pigmented lesion structure. This study aims to apply fractal dimension analysis to differentiate melanomas, dysplastic nevi, and benign nevi in polarized and non-polarized light. A total of 87 Eighty-four patients with 97 lesions were included in this study. All examined lesions were photographed under polarized and non-polarized light, surgically removed, and examined by a histopathologist to establish the correct diagnosis. The obtained images were then processed and analyzed. Area, perimeter, and fractal dimensions of shape and texture were calculated for all the lesions under polarized and non-polarized light. The fractal dimension of shape in polarized light enables differentiating melanomas, dysplastic nevi, and benign nevi. It also makes it possible to distinguish melanomas from benign and dysplastic nevi under non-polarized light. The fractal dimension of texture allows distinguishing melanomas from benign and dysplastic nevi under polarized light. All examined parameters of shape and texture can be used for developing an automatic computer-aided diagnosis system. Polarized light is superior to non-polarized light for imaging texture details.

10.
Materials (Basel) ; 15(6)2022 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-35329519

RESUMO

The surface topography of orthodontic brackets can have a significant impact on both the effectiveness of the therapy and the behavior of these elements in the oral cavity environment. In this situation, striving to obtain the most uniform, smooth surface in a repeatable manner for each manufactured element should be a sine qua non condition for each supplier of orthodontic brackets. Therefore, it is necessary to analyze the surfaces of orthodontic brackets using different methods. One of them-that is relatively simple and repeatable-is the analysis of the fractal dimension and the analysis of the textures of the optical images on the surface. In the presented study, fractal dimension analysis and texture analysis were performed by selecting four brackets from three different manufacturers (Mini Sprint, Sprint, Nu-Edge, Orthos SS). The area of each bracket slot was analyzed at six predefined points. The smoothest and most uniform and reproducible surface structure was shown by the Mini Sprint bracket. On the other hand, Sprint brackets showed the least homogeneous and least repeatable surface structure.

11.
Materials (Basel) ; 15(18)2022 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-36143665

RESUMO

Orthodontic removable appliances made of transparent thermoplastic materials-aligners-are becoming increasingly popular in contemporary orthodontic practice. It is important for the clinician to fully understand the mechanical properties and behavior of the appliance used. Because of that, the aim of our study was to investigate the changes in aligner surface after immersion in Coca-Cola and orange juice. For surface evaluation, fractal analysis, texture analysis, and wetting angle measurement were performed. Statistically significant changes were found between some of the groups in the fractal dimension analysis. In texture analysis, all but one intergroup comparison showed statistically significant differences. For wetting angle assessment, statistically significant differences were found. These were, however, more numerous when assessing glycol droplets, rather than water droplets. Fractal dimension analysis confirmed a correlation between the intensity of changes in the aligner surface with immersion time in the liquids assessed. Texture analysis showed a high sensitivity to the changes in aligner surface. It failed, however, to reveal changes relative to immersion time. Wetting angle analysis revealed aligner surface degradation for Coca-Cola. It did not, however, prove the dependence of the intensity of this degradation as a function of time. Both Coca-Cola and orange juice can cause aligner surface degradation.

12.
Materials (Basel) ; 15(8)2022 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-35454406

RESUMO

Laser-induced periodic surface structures (LIPSS) are the sub-wavelength periodic nanostructures generated by the femtosecond laser. Implant topography and its nanostructural changes can be important for biomedical applications. In order to compare the surface topography of different implants, appropriate mathematical and physical descriptive methods should be provided. The aim of the study was to evaluate the experimental LIPSS-based-Low Spatial Frequency LIPSS (LSFL) dental implant surfaces. Novel methods of surface analysis, such as Fractal Dimension Analysis and Texture Analysis, were compared to the standard surface roughness evaluation. Secondary, cell viability, and attachment tests were applied in order to evaluate the biological properties of the new titanium surface and to compare their correlation with the physical properties of the new surfaces. A Normal Human Dermal Fibroblast (NHDF) cytotoxicity test did not show an impact on the vitality of the cells. Our study has shown that the laser LIPSS implant surface modifications significantly improved the cell adhesion to the tested surfaces. We observed a strong correlation of adhesion and the growth of cells on the tested surface, with an increase in implant surface roughness with the best results for the moderately rough (2 µm) surfaces. Texture and fractal dimension analyses are promising methods to evaluate dental implants with complex geometry.

13.
Lasers Surg Med ; 43(7): 607-13, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22057488

RESUMO

BACKGROUND AND OBJECTIVE: The photodynamic therapy is a well-known method of treatment of both malignant tumors and non-tumor lesions in human patients. In the present study, we aimed at evaluating the in vitro efficacy of the new photosensitizing agents, vacataporphyrin (VP), and divacataporphyrin (DVP). MATERIALS AND METHODS: The effectiveness of VP and DVP was compared to well-known photosensitizers, that is, hematoporphyrin derivative (HPD) and chlorin e6 (Ce6) in identical in vitro conditions. The experiment was performed on a well-established breast cancer cell line, MCF-7 and compared to HCV 29T11-2-D1 cell line. Cells were incubated in standard conditions and they were exposed to different concentrations of VP, DVP, HPD, and Ce6, that is, 180, 90, 45, 22.5, and 10 µg/ml. After incubation with photosensitizers, the cells were washed, medium was exchanged and the cells were subjected to irradiation at the proper wavelengths, light intensity (100 mW/sq cm), and total light doses 4.5 and 9 J/sq cm. RESULTS: Our results showed that the VP and DVP are potent photosensitizers and the photocytotoxic effect after the incubation with DVP was much better than that of VP. The cytotoxic effects of VP and DVP were less intensive than these of HPD and Ce6. VP and DVP also accumulated well in the tumor cells. Our results also indicated that the VP and DVP effectiveness on MCF-7 cells was photosensitizer dose and light dose dependent. CONCLUSION: The overall properties revealed by both new porphyrins and particularly a possibility for excitation at a higher wavelength and thus a deeper tissue penetration, make them promising candidates for further in vivo experiments.


Assuntos
Neoplasias da Mama/tratamento farmacológico , Fotoquimioterapia , Fármacos Fotossensibilizantes/uso terapêutico , Porfirinas/uso terapêutico , Linhagem Celular Tumoral , Clorofilídeos , Relação Dose-Resposta a Droga , Feminino , Derivado da Hematoporfirina/farmacocinética , Derivado da Hematoporfirina/uso terapêutico , Humanos , Fármacos Fotossensibilizantes/farmacocinética , Porfirinas/farmacocinética
14.
Materials (Basel) ; 14(13)2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34279257

RESUMO

Mechanical properties of orthodontic wires can have a very significant impact both on the resistance of the entire appliance to the oral cavity conditions and directly on the effectiveness of the therapy. Striving to achieve repeatability of mechanical characteristics of orthodontic wires of a given type should be an obligatory condition in their production. To achieve it, these components should be thoroughly analyzed using various mechanical tests. Twenty-four steel and nickel-titanium orthodontic wires from four different manufacturers were examined. Each wire was subjected to fractal dimension analysis and texture analysis. The two sides of each wire were compared against each other, as well as in terms of variation in the surface area for each wire type made by different manufacturers. Most wires showed significant variation in fractal dimension and texture, both when comparing two sides of the same wire and between individual wires of a given type made by a single manufacturer. When conducting research and clinically using orthodontic wires made of Ni-Ti alloys and stainless steel, it should be assumed that the surface of orthodontic wires shows a significant degree of variation, and wires of the same type from the same manufacturer may differ significantly in this respect.

15.
Materials (Basel) ; 14(15)2021 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-34361334

RESUMO

Venous lake (VL) is a common lesion resulting from the enlargement of thin-walled veins surrounded by a thick wall of fibrous tissue. Photocoagulation is becoming one of the basic methods for treating small vascular lesions. The aim of this study was an application of texture analysis (TA) and fractal dimension analysis (FDA) to evaluate VL treatment. Twenty-three VLs were included in the study. We used a 980 nm diode laser, 6 W, 100 ms pulse mode with a 50% duty cycle. The total dose of energy was in a range from 80 J to 600 J. We used the difference of intensity algorithm for FDA and microcontrast and a co-occurrence matrix for TA. A complete therapeutic effect was achieved in 83%, and in 9%, scar formation was observed after three months. No healing was observed in 4%, and there was partial healing in 4%. No differences in FD were observed between the lesions after three months and the healthy mucosa. The fractal dimension and microcontrast of a vascular lesion are mutually coupled. FDA and TA is a useful and objective method of assessing treatment effects for venous lakes. The non-contact mode of the 980 nm diode laser is an effective and safe method for treating a VL.

16.
Materials (Basel) ; 14(19)2021 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-34640254

RESUMO

Biocompatibility is defined as "the ability of a biomaterial, prosthesis, or medical device to perform with an appropriate host response in a specific application". Biocompatibility is especially important for restorative dentists as they use materials that remain in close contact with living tissues for a long time. The research material involves six types of cement used frequently in the subgingival region: Ketac Fil Plus (3M ESPE, Germany), Riva Self Cure (SDI, Australia) (Glass Ionomer Cements), Breeze (Pentron Clinical, USA) (Resin-based Cement), Adhesor Carbofine (Pentron, Czech Republic), Harvard Polycarboxylat Cement (Harvard Dental, Great Britain) (Zinc polycarboxylate types of cement) and Agatos S (Chema-Elektromet, Poland) (Zinc Phosphate Cement). Texture and fractal dimension analysis was applied. An evaluation of cytotoxicity and cell adhesion was carried out. The fractal dimension of Breeze (Pentron Clinical, USA) differed in each of the tested types of cement. Adhesor Carbofine (Pentron, Czech Republic) cytotoxicity was rated 4 on a 0-4 scale. The Ketac Fil Plus (3M ESPE, Germany) and Riva Self Cure (SDI, Australia) cements showed the most favorable conditions for the adhesion of fibroblasts, despite statistically significant differences in the fractal dimension of their surfaces.

17.
Materials (Basel) ; 14(17)2021 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-34501009

RESUMO

Thanks to the continuous development of light-curing resin composites it is now possible to print permanent single-tooth restorations. The purpose of this study was to compare resin composites for milling -Gandio Blocks (GR), Brilliant Crios (CR) and Enamic (EN) with resin composite for 3D printing-Varseo Smile Crown plus (VSC). Three-point bending was used to measure flexural strength (σf) and flexural modulus (Ef). The microhardness was measured using a Vickers method, while fractographic, microstructural, texture and fractal dimension (FD) analyses were performed using SEM, optical microscope and picture analysis methods. The values of σf ranged from 118.96 (±2.81) MPa for EN to 186.02 (±10.49) MPa for GR, and the values of Ef ranged from 4.37 (±0.8) GPa for VSC to 28.55 (±0.34) GPa for EN. HV01 ranged from 25.8 (±0.7) for VSC to 273.42 (±27.11) for EN. The filler content ranged from 19-24 vol. % for VSC to 70-80 vol. % for GR and EN. The observed fractures are typical for brittle materials. The correlation between FD of materials microstructure and Ef was observed. σf of the printed resin depends on layers orientation and is significantly lower than σf of GR and CR. Ef of the printed material is significantly lower than Ef of blocks for milling.

18.
J Clin Med ; 10(16)2021 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-34441967

RESUMO

BACKGROUND: The aim of the study was to compare the effectiveness of photodynamic therapy (PDT) to steroid therapy in the treatment of oral lichen planus (OLP). Due to the lack of commercially available drug carriers, innovative proprietary solutions were used for both the photosensitiser and the steroid carrier-in the first case to shorten and in the second to extend the contact of the active substance with the mucosa. METHODS: A prospective, randomised, single-blind, 12-week full contralateral split-mouth clinical trial of 30 patients with bilateral oral lichen planus was conducted. The prepared matrices were incorporated with active substances methylene blue 5% and 0,05% triamcinolone. The size of lesions, Thongprasom, ABISIS, and VAS scale were evaluated. RESULTS: Relatively high rates of complete remission of lichen were demonstrated: immediately after treatment, 33.3% with PDT and 22.2% with triamcinolone (TA), and after 3 months, 54.2% with PDT and 62.9% with TA. After 3 months of treatment, a reduction in the area of evaluated lesions of 52.7% for PDT and 41.7% for TA was achieved. CONCLUSION: In situations of topical or general contraindications to oral corticosteroids, resistance to them, or the need for repeated treatment in a short period of time, PDT appears to be a very promising treatment option.

19.
J Pers Med ; 11(2)2021 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-33557038

RESUMO

PURPOSE: to assess the effect of photobiomodulation (PBM) on human gingival fibroblast proliferation. METHODS: The study was conducted using the primary cell cultures of human fibroblasts collected from systemically healthy donors. Three different laser types, Nd:YAG (1064 nm), infrared diode laser (980 nm), and prototype led laser emitting 405, 450, and 635 nm were used to irradiate the fibroblasts. Due to the patented structure of that laser, it was possible to irradiate fibroblasts with a beam combining two or three wavelengths. The energy density was 3 J/cm2, 25 J/cm2, 64 J/cm2. The viability and proliferation of cells were determined using the (Thiazolyl Blue Tetrazolium Blue) (MTT) test conducted 24, 48, and 72 h after laser irradiation. RESULTS: The highest percentage of mitochondrial activity (MA = 122.1%) was observed in the group irradiated with the 635 nm laser, with an energy density of 64 J/cm2 after 48 h. The lowest percentage of MA (94.0%) was observed in the group simultaneously irradiated with three wavelengths (405 + 450 + 635 nm). The use of the 405 nm laser at 25 J/cm2 gave similar results to the 635 nm laser. CONCLUSIONS: The application of the 635 nm and 405 nm irradiation caused a statistically significant increase in the proliferation of gingival fibroblasts.

20.
Materials (Basel) ; 14(18)2021 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-34576672

RESUMO

BACKGROUND: Oral Lichen planus (OLP) is a chronic inflammatory disease. Topical steroids are used as the treatment of choice. The alternative is photodynamic therapy (PDT). The study aimed to fabricate optimal biodegradable matrices for methylene blue or triamcinolone acetonide because of a lack of currently commercially available carriers that could adhere to the mucous. METHODS: The study was designed as a 12-week single-blind prospective randomized clinical trial with 30 patients, full contralateral split-mouth design. Matrices for steroid and photosensitizer and laser device were fabricated. Fractal and texture analysis of photographs, taken in 405, 450, 405 + 450 nm wavelength, of lesions was performed to increase the objectivity of the assessment of treatment. RESULTS: We achieved two total responses for treatment in case of steroid therapy and one in the case of PDT. Partial response was noted in 17 lesions treated using local steroid therapy and 21 in the case of PDT. No statistically significant differences were found between the effectiveness of both used methods. Statistically significant differences in fractal dimension before and after treatment were observed only in the analysis of photographs taken in 405 + 450 nm wavelength. CONCLUSIONS: Photodynamic therapy and topical steroid therapy are effective methods for treating OLP. Using a carrier offers the possibility of a more predictable and effective method of drug delivery into the mucous membrane. Autofluorescence enables the detection of lesions especially at the early stage of their development.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA