Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Malar J ; 17(1): 214, 2018 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-29843721

RESUMO

BACKGROUND: Although microscopy is a standard diagnostic tool for malaria and the gold standard, it is infrequently used because of unavailability of laboratory facilities and the absence of skilled readers in poor resource settings. Malaria rapid diagnostic tests (RDT) are currently used instead of or as an adjunct to microscopy. However, at very low parasitaemia (usually < 100 asexual parasites/µl), the test line on malaria rapid diagnostic tests can be faint and consequently hard to visualize and this may potentially affect the interpretation of the test results. Fio Corporation (Canada), developed an automated RDT reader named Deki Reader™ for automatic analysis and interpretation of rapid diagnostic tests. This study aimed to compare visual assessment and automated Deki Reader evaluations to interpret malaria rapid diagnostic tests against microscopy. Unlike in the previous studies where expert laboratory technicians interpreted the test results visually and operated the device, in this study low cadre health care workers who have not attended any formal professional training in laboratory sciences were employed. METHODS: Finger prick blood from 1293 outpatients with fever was tested for malaria using RDT and Giemsa-stained microscopy for thick and thin blood smears. Blood samples for RDTs were processed according to manufacturers' instructions automated in the Deki Reader. Results of malaria diagnoses were compared between visual and the automated devise reading of RDT and microscopy. RESULTS: The sensitivity of malaria rapid diagnostic test results interpreted by the Deki Reader was 94.1% and that of visual interpretation was 93.9%. The specificity of malaria rapid diagnostic test results was 71.8% and that of human interpretation was 72.0%. The positive predictive value of malaria RDT results by the Deki Reader and visual interpretation was 75.8 and 75.4%, respectively, while the negative predictive values were 92.8 and 92.4%, respectively. The accuracy of RDT as interpreted by DR and visually was 82.6 and 82.1%, respectively. CONCLUSION: There was no significant difference in performance of RDTs interpreted by either automated DR or visually by unskilled health workers. However, despite the similarities in performance parameters, the device has proven useful because it provides stepwise guidance on processing RDT, data transfer and reporting.


Assuntos
Testes Diagnósticos de Rotina/métodos , Malária/diagnóstico , Microscopia/métodos , Pacientes Ambulatoriais/estatística & dados numéricos , Parasitemia/diagnóstico , Adolescente , Adulto , Feminino , Instalações de Saúde , Humanos , Masculino , Instalações Militares , Sensibilidade e Especificidade , Tanzânia , Adulto Jovem
2.
BMC Public Health ; 14: 904, 2014 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-25183300

RESUMO

BACKGROUND: HIV and Non communicable diseases (NCDs) are major problem of public health importance in developing countries. This study was conducted to explore and establish information on the magnitude, distribution of NCDs risk factors among people living with HIV (PLWHIV) which is scarce in Tanzania. METHOD: A cross sectional study was conducted to PLWHIV from 12 care and treatment clinics in Dar es Salaam and Mbeya regions from October 2011 to February 2012. Data on demographic characteristics, NCD risk factors including behavioral, biochemical tests and physical measurements was collected from PLWHIV. RESULTS: Of 754 PLWHIV recruited, 671(89.0%) consented to participate in the study and 354/671(52.8%) were on antiretroviral therapy (ART). The following NCD risk factors: raised blood levels of low density lipoprotein (61.3% vs 38.7%, p < 0.001) total cholesterol (TC) (71.6% vs 28.4%, p < 0.001) and triglyceride (67.0% vs 33.0%, p = 0.001) as well as overweight/obesity (61.1% vs 38.9%, p = 0.010), abnormal waist circumference (61.7% vs 38.3%, p < 0.001) and being aged >40 years (63.3% vs 36.7%, p < 0.001) were more prevalent among PLWHIV on ART than ART naïve. The prevalence of Diabetes mellitus among PLWHIV was 4.2% and was slightly high among those ART naïve (4.7% vs 3.7%). The prevalence of hypertension was 26.2% and was high among those on ART (30.0% vs 21.9%, p = 0.010). Being aged >40 years (AOR = 2.52, 95% CI 1.37-4.63), abnormal waist circumference (AOR = 2.37 95% CI 1.13-5.00), overweight/obesity (AOR = 2.71, 95% CI 1.26-5.84) and male sex (AOR = 1.17, 1.02-4.20) were the predictors of hypertension among patients on ART while raised TC (AOR = 1.47 (1.01-2.21) and being aged >40 years (AOR = 3.42, 95% CI 2.06-5.70) were predictors for hypertension among ART naïve patients. CONCLUSION: This study has revealed that the magnitude of NCD risk factors is significantly higher among PLWHIV on ART than those not on ART. Initiating and strengthening of interventions for minimizing preventable NCD risks should be considered when initiating ART among PLWHIV. Regular monitoring of NCD risk factors is of paramount importance among ART patients.


Assuntos
Diabetes Mellitus/epidemiologia , Infecções por HIV/epidemiologia , Hipertensão/epidemiologia , Sobrepeso/epidemiologia , Adolescente , Adulto , Fatores Etários , Colesterol/sangue , Comorbidade , Estudos Transversais , Países em Desenvolvimento , Diabetes Mellitus/sangue , Feminino , Infecções por HIV/sangue , Humanos , Hipertensão/sangue , Masculino , Pessoa de Meia-Idade , Sobrepeso/sangue , Prevalência , Fatores de Risco , Fatores Sexuais , Tanzânia/epidemiologia , Triglicerídeos/sangue , Circunferência da Cintura , Adulto Jovem
3.
BMC Res Notes ; 13(1): 447, 2020 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-32948227

RESUMO

OBJECTIVE: Good quality microscopy is critical for accurate detection and confirmation of malaria parasite infections. Microscopy relies on the skills of technicians to prepare and read slides, high quality reagents, and a good program of internal and external quality control (EQA), which are lacking in most malaria endemic settings. This study was undertaken between January 2016 and December 2018 to pilot an EQA of microscopy for improved diagnosis of malaria and patient care in Tanzanian Military health facilities. RESULTS: Of all blood smears crosschecked (n = 4000) at baseline, only 38.5% were incorrectly diagnosed by laboratory staff with false positive and negative rates of 46.7% and 16.4%, respectively. During the implementation of EQA, false positive and negative results decreased due to increased quality index of slide preparation and reading through supportive supervision, and retraining of laboratory personnel. There was a gradual increase of quarterly and annual total quality index for all laboratories, from 60% in 2016 to 78% in 2017 and 90% in 2018. The mean proficiency testing performance scores also increased from 75% in 2016 to 82% in 2017 and to 90% in 2018. Poor blood smear preparation and staining contributed to high false positive and negative rates while EQA helped in improvement of diagnostics.


Assuntos
Malária , Parasitos , Animais , Testes Diagnósticos de Rotina , Instalações de Saúde , Humanos , Laboratórios , Malária/diagnóstico , Malária/epidemiologia , Microscopia , Garantia da Qualidade dos Cuidados de Saúde
4.
PLoS One ; 13(12): e0208583, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30589853

RESUMO

INTRODUCTION: Internal and external quality control (QC) of rapid diagnostic tests (RDTs) is important to increase reliability of RDTs currently used to diagnose malaria. However, cross-checking of used RDTs as part of quality assurance can rarely be done by off-site personnel because there is no guarantee of retaining visible test lines after manufacturers' recommended reading time. Therefore, this study examined the potential of using Fionet™ technology for remote RDT quality monitoring at seven clinics, identifying reasons for making RDT processing and interpretation errors, and taking corrective actions for improvement of diagnosis and consequently improved management of febrile patients. METHODS: The study was conducted at seven military health facilities in Mainland Tanzania and utilized RDTs capable of detecting Plasmodium falciparum specific Histidine-rich protein 2 (Pf-HRP2) and the genus specific Plasmodium lactate dehydrogenase (pLDH) for other species of plasmodium (P. vivax, P. malariae or P. ovale; pan-pLDH). Patients' data and images of processed RDTs from seven clinics were uploaded on a Fionet web portal and reviewed regularly to monitor preparation procedures and visual interpretation of test results compared to automated analysis using the Deki reader of RDT. Problems detected were rapidly communicated to remote laboratory personnel at the clinic for corrective action and follow-up of patients who were falsely diagnosed as negative and missed treatment. Factors contributing to making errors in visual interpretation of RDT results were analyzed during visits to the health facilities. RESULTS: A total of 1,367 (1.6%) out of 83,294 RDT test images uploaded to the Fionet portal had discordant test results of which 822 (60.1%) and 545 (39.9%) were falsely reported as negative and positive, respectively. False negative and false positive test results were common for a single test line in 515 (62.7%) and 741 (54.2%) tests, respectively. Out of 1,367 RDT images assessed, 98 (7.2%) had quality problems related to preparation procedures of which 95(96.9%) errors were due to putting too much blood on the sample well or insufficient buffer in the respective wells. The reasons for discrepant results included, false reporting of none existent lines in 526 (38.5%) tests, missing a faint positive line in 493 (36.1%), missing a strong positive line in 248(18.1%) and errors caused by poorly processed RDTs in 96 (7.2%) tests. Among the false negative tests (n = 822), 669 (48.9%) patients were eligible for follow-up and only 339 (48.5%) were reached and 291 (85.8%) received appropriate anti-malaria therapy. CONCLUSION: Fionet technology enabled remote monitoring of RDT quality issues, identifying reasons contributing to laboratory personnel making errors and provided a rapid method to implement corrective actions at remote sites to improve malaria diagnosis and consequently improved health care management of febrile patients infected with malaria.


Assuntos
Testes Diagnósticos de Rotina , Pessoal de Saúde , Malária/diagnóstico , Análise e Desempenho de Tarefas , Adolescente , Adulto , Antígenos de Protozoários/análise , Criança , Pré-Escolar , Erros de Diagnóstico , Testes Diagnósticos de Rotina/normas , Feminino , Instalações de Saúde , Humanos , Lactente , Recém-Nascido , L-Lactato Desidrogenase/análise , L-Lactato Desidrogenase/normas , Masculino , Plasmodium falciparum/metabolismo , Proteínas de Protozoários/análise , Proteínas de Protozoários/normas , Controle de Qualidade , Tanzânia , Adulto Jovem
5.
Infect Dis (Auckl) ; 10: 1178633617731741, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29317828

RESUMO

Based on the observation that the parasite Onchocerca volvulus selectively absorbs vitamin A from the host, and the known toxicity of vitamin A in higher concentration, it was hypothesized that dying microfilariae (mf) release their stores of vitamin A (retinoids) into the host circulation in toxic concentrations, inducing the signs and symptoms of onchocerciasis. We conducted a pilot study to test the hypothesis in Songea communities in Southern Tanzania, where mass drug administration with ivermectin had not been implemented by the time of the survey. The specific aim was to evaluate the correlation between the diagnosis of onchocerciasis and increased levels of retinoic acid at infection sites. The analysis was performed by determining copy numbers of a genome of O volvulus present in skin snip samples of persons with onchocerciacis, and correlating these numbers with expression levels of retinoic acid receptor-α (RAR-α), which is inducible by retinoic acid. Total DNA and RNA were extracted from each of 25 mf-positive and 25 mf-negative skin samples and evaluated using quantitative polymerase chain reaction with appropriate negative controls. Analysis of the samples, adjusted with glyceraldehyde 3-phosphate dehydrogenase gene levels, revealed that most samples with detectable RAR-α transcripts had higher levels of RAR-α expression than the assay control. However, the quality and number of samples were insufficient for statistical analysis. Fold data on the expression levels of both O volvulus DNA and RAR RNA suggested a possible trend toward higher relative RAR-α expression in samples with higher levels of O volvulus DNA ( r2 = 0.25, P = .079). Evidence of a contribution of vitamin A to the pathology of onchocerciasis thus remains elusive. Future studies on the role of retinoids in onchocerciasis will require larger groups of participants as well as careful monitoring of the cold chain and tissue storage procedures in view of the sensitivity of vitamin A to heat and light.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA