Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Jpn J Radiol ; 42(6): 639-647, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38345725

RESUMO

PURPOSE: Whole-body silicon photomultiplier positron emission tomography (WB SiPM PET) could be used to diagnose breast cancer spread before lumpectomy. We aimed to investigate the method of measuring the tumor size by WB SiPM PET as a basis for diagnosing breast cancer spread in the breast. MATERIALS AND METHODS: We retrospectively reviewed 35 breast cancer lesions in 32 patients who underwent WB SiPM PET/CT in the prone position as preoperative breast cancer examinations from September 2020 to March 2022. In all cases, a 20-mm spherical VOI was placed in the normal mammary gland to measure the mean standardised uptake value (SUVmean) and the standard deviation (SD) of 18F-fluorodeoxyglucose (FDG) uptake. We prepared four types of candidates (SUVmean + 2 SD, SUVmean + 3 SD, 1.5 SUVmean + 2 SD, 1.5 SUVmean + 3 SD) for thresholds for delineating tumor contours on PET images. On the semiautomatic viewer soft, the maximum tumor sizes were measured at each of the four thresholds and compared with the pathological tumor sizes, including the extensive intraductal component (EIC). RESULTS: The lesion detection sensitivity was 97% for WB SiPM PET. PET detected 34 lesions, excluding 4-mm ductal carcinomas in situ (DCIS). PET measurements at the '1.5 SUVmean + 2 SD' threshold demonstrated values closest to the pathological tumor sizes, including EIC. Moreover, '1.5 SUVmean + 2 SD' had the highest concordance (63%). CONCLUSIONS: The study demonstrated that among various PET thresholds, the '1.5 SUVmean + 2 SD' threshold exhibited the best performance. However, even with this threshold, the concordance rate was limited to only 63%.


Assuntos
Neoplasias da Mama , Estudos de Viabilidade , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Silício , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Adulto , Compostos Radiofarmacêuticos , Imagem Corporal Total/métodos , Tomografia por Emissão de Pósitrons/métodos , Carga Tumoral , Idoso de 80 Anos ou mais , Cuidados Pré-Operatórios/métodos
2.
Cureus ; 15(3): e36881, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37123667

RESUMO

CT has become a commonly used diagnostic procedure in clinical practice, particularly in emergency healthcare delivery. Accordingly, the increase in CT usage has increased the likelihood of incidental detections (ID) of renal cell carcinomas (RCCs). This article discusses key points and limitations associated with the diagnosis and characterization of T1a RCC (≤4 cm in diameter) and shows how to improvise on the differentiation of T1a RCC with unenhanced CT (UE-CT). We retrospectively reviewed UE-CT findings of cases associated with the histopathologic diagnosis of T1a RCC and examined the discrimination capacity and radiological characteristics with regard to small RCCs (SRCCs). Detection and characterization of T1a RCC based on UE-CT are not easy in many cases due to limitations in CT findings, but there are notable radiological features to facilitate detection and differentiation. The growth pattern is important for the detection of SRCCs. Internal characteristic features (average attenuation, heterogeneity) are useful for the characterization of the RCC. In addition, CT image visualization techniques may help improve the detectability of RCCs on UE-CT. Radiological features are important in detecting SRCCs and facilitating further examination. In this study, we discuss some cases of T1a RCCs and evaluate the radiological characteristics of the tumors seen on UE-CT.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA