Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Anal Chem ; 84(13): 5489-93, 2012 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-22702514

RESUMO

We present a spectrometer for sensitive absorption measurements in liquids across broad spectral bandwidths. The spectrometer combines the unique spectral properties of incoherent supercontinuum light sources with the advantages of cavity ring-down spectroscopy, which is a self-calibrating technique. A custom-built avalanche photodiode array is used for detection, permitting the simultaneous measurement of ring-down times for up to 64 different spectral components at nanosecond temporal resolution. The minimum detectable absorption coefficient was measured to be 3.2 × 10(-6) cm(-1) Hz(-1/2) at 527 nm. We show that the spectrometer is capable of recording spectral differences in trace levels of blood before and after hemolysis.


Assuntos
Análise Química do Sangue/instrumentação , Análise Espectral/instrumentação , Desenho de Equipamento , Eritrócitos/citologia , Hemólise , Humanos , Rodaminas/análise , Sensibilidade e Especificidade
2.
Opt Express ; 17(3): 1557-70, 2009 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-19188985

RESUMO

Frequency-domain fluorescence lifetime imaging microscopy (FD-FLIM) is a fast and accurate way of measuring fluorescence lifetimes in widefield microscopy. However, the resolution of multiple exponential fluorescence decays has remained beyond the reach of most practical FD-FLIM systems. In this paper we describe the implementation of FD-FLIM using a 40 MHz pulse train derived from a supercontinuum source for excitation. The technique, which we term multi-harmonic FLIM (mhFLIM), makes it possible to accurately resolve biexponential decays of fluorophores without any a priori information. The system's performance is demonstrated using a mixture of spectrally similar dyes of known composition and also on a multiply-labeled biological sample. The results are compared to those obtained from time correlated single photon counting (TCSPC) microscopy and a good level of agreement is achieved. We also demonstrate the first practical application of an algorithm derived by G. Weber [1] for analysing mhFLIM data. Because it does not require nonlinear minimisation, it offers potential for realtime analysis during acquisition.


Assuntos
Microscopia/instrumentação , Microscopia/métodos , Algoritmos , Calibragem , Linhagem Celular Tumoral , Corantes/química , Fluorescência , Análise de Fourier , Humanos , Soluções , Fatores de Tempo
3.
Opt Express ; 17(25): 22747-60, 2009 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-20052200

RESUMO

The ability to quantify the fluorescence signals from multiply labeled biological samples is highly desirable in the life sciences but often difficult, because of spectral overlap between fluorescent species and the presence of autofluorescence. Several so called unmixing algorithms have been developed to address this problem. Here, we present a novel algorithm that combines measurements of lifetime and spectrum to achieve unmixing without a priori information on the spectral properties of the fluorophore labels. The only assumption made is that the lifetimes of the fluorophores differ. Our method combines global analysis for a measurement of lifetime distributions with singular value decomposition to recover individual fluorescence spectra. We demonstrate the technique on simulated datasets and subsequently by an experiment on a biological sample. The method is computationally efficient and straightforward to implement. Applications range from histopathology of complex and multiply labelled samples to functional imaging in live cells.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Microscopia de Fluorescência por Excitação Multifotônica/métodos , Reconhecimento Automatizado de Padrão/métodos , Inteligência Artificial , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Phys Rev Lett ; 103(18): 183902, 2009 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-19905807

RESUMO

Using a hydrogen-filled hollow-core photonic crystal fiber as a nonlinear optical gas cell, we study amplification of ns-laser pulses by backward rotational Raman scattering. We find that the amplification process has two characteristic stages. Initially, the pulse energy grows and its duration shortens due to gain saturation at the trailing edge of the pulse. This phase is followed by formation of a symmetric pulse with a duration significantly shorter than the phase relaxation time of the Raman transition. Stabilization of the Stokes pulse profile to a solitonlike hyperbolic secant shape occurs as a result of nonlinear amplification at its front edge and nonlinear absorption at its trailing edge (caused by energy conversion back to the pump field), leading to a reshaped pulse envelope that travels at superluminal velocity.

5.
Science ; 272(5266): 1310-4, 1996 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-8650540

RESUMO

The saturated hydrocarbons ethane (C2H6) and methane (CH4) along with carbon monoxide (CO) and water (H2O) were detected in comet C/1996 B2 Hyakutake with the use of high-resolution infrared spectroscopy at the NASA Infrared Telescope Facility on Mauna Kea, Hawaii. The inferred production rates of molecular gases from the icy, cometary nucleus (in molecules per second) are 6.4 X 10(26) for C2H6, 1.2 X 10(27) for CH4, 9.8 X 10(27) for CO, and 1.7 X 10(29) for H2O. An abundance of C2H6 comparable to that of CH4 implies that ices in C/1996 B2 Hyakutake did not originate in a thermochemically equilibrated region of the solar nebula. The abundances are consistent with a kinetically controlled production process, but production of C2H6 by gas-phase ion molecule reactions in the natal cloud core is energetically forbidden. The high C2H6/CH4 ratio is consistent with production of C2H6 in icy grain mantles in the natal cloud, either by photolysis of CH4-rich ice or by hydrogen-addition reactions to acetylene condensed from the gas phase.


Assuntos
Monóxido de Carbono/análise , Etano/análise , Meteoroides , Metano/análise , Água/análise , Meio Ambiente Extraterreno , Gelo , Análise Espectral
6.
Science ; 252(5005): 537-42, 1991 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-17838486

RESUMO

The spatial organization and time dependence of Jupiter's stratospheric temperatures have been measured by observing thermal emission from the 7.8-micrometer CH(4) band. These temperatures, observed through the greater part of a Jovian year, exhibit the influence of seasonal radiative forcing. Distinct bands of high temperature are located at the poles and mid-latitudes, while the equator alternates between warm and cold with a period of approximately 4 years. Substantial longitudinal variability is often observed within the warm mid-latitude bands, and occasionally elsewhere on the planet. This variability includes small, localized structures, as well as large-scale waves with wavelengths longer than approximately 30,000 kilometers. The amplitudes of the waves vary on a time scale of approximately 1 month; structures on a smaller scale may have lifetimes of only days. Waves observed in 1985, 1987, and 1988 propagated with group velocities less than +/-30 meters per second.

7.
Science ; 265(5172): 625-31, 1994 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-17752758

RESUMO

The spatial organization and time dependence of Jupiter's temperatures near 250-millibar pressure were measured through a jovian year by imaging thermal emission at 18 micrometers. The temperature field is influenced by seasonal radiative forcing, and its banded organization is closely correlated with the visible cloud field. Evidence was found for a quasi-periodic oscillation of temperatures in the Equatorial Zone, a correlation between tropospheric and stratospheric waves in the North Equatorial Belt, and slowly moving thermal features in the North and South Equatorial Belts. There appears to be no common relation between temporal changes of temperature and changes in the visual albedo of the various axisymmetric bands.

8.
Opt Express ; 16(14): 10178-88, 2008 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-18607425

RESUMO

Supercontinuum radiation sources are attractive for spectroscopic applications owing to their broad wavelength coverage, which enables spectral signatures of multiple species to be detected simultaneously. Here we report the first use of a supercontinuum radiation source for broadband trace gas detection using a cavity enhanced absorption technique. Spectra were recorded at bandwidths of up to 100 nm, encompassing multiple absorption bands of H(2)O, O(2) and O(2)-O(2). The same instrument was also used to make quantitative measurements of NO(2) and NO(3). For NO(3) a detection limit of 3 parts-per-trillion in 2 s was achieved, which corresponds to an effective 3sigma sensitivity of 2.4 x 10(-9) cm(-1)Hz(-1/2). Our results demonstrate that a conceptually simple and robust instrument is capable of highly sensitive broadband absorption measurements.


Assuntos
Monitoramento Ambiental/instrumentação , Espectrofotometria/instrumentação , Espectrofotometria/métodos , Poluentes Atmosféricos/análise , Atmosfera/análise , Monitoramento Ambiental/métodos , Desenho de Equipamento , Gases , Dióxido de Nitrogênio/análise , Óxidos de Nitrogênio/análise , Oxigênio/química , Física/métodos , Radiação , Espectrofotometria Infravermelho/instrumentação , Espectrofotometria Infravermelho/métodos , Água/química
9.
Opt Express ; 16(22): 17972-81, 2008 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-18958077

RESUMO

We present a versatile method for selective mode coupling into higher-order modes of photonic crystal fibers, using holograms electronically generated by a spatial light modulator. The method enables non-mechanical and completely repeatable changes in the coupling conditions. We have excited higher order modes up to LP(31) in hollow-core photonic crystal fibers. The reproducibility of the coupling allows direct comparison of the losses of different guided modes in both hollow-core bandgap and kagome-lattice photonic crystal fibers. Our results are also relevant to applications in which the intensity distribution of the light inside the fiber is important, such as particle- or atom-guidance.

10.
Br J Anaesth ; 100(1): 55-65, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17982168

RESUMO

BACKGROUND: We tested the hypothesis that sodium nitroprusside (SNP) might improve the impairment of hepatosplanchnic microcirculatory blood flow (MBF) in septic shock. METHODS: Fourteen pigs were anaesthetized and their lungs mechanically ventilated. Sepsis was induced with i.v. infusion of live Pseudomonas aeruginosa [1x10(8) colony forming units (CFU) ml(-1) kg(-1)] for 1 h. Sixty minutes later, the animals received in a random succession either SNP or normal saline for 30 min. Mean arterial pressure (MAP), cardiac index (CI), mean pulmonary artery pressure (MPAP), carbon dioxide tension of the ileal mucosa (PCO2; by gas tonometry), ileal mucosal and hepatic MBF by laser Doppler flowmetry, blood gases, and lactates were assessed before, during administration, and 30 min after discontinuing the test drug. RESULTS: Bacterial infusion promoted hypodynamic shock (MAP -18%, CI -33%, ileal MBF -19%, and hepatic MBF -27%), which was converted to normodynamic shock by resuscitation. During SNP infusion, ileal mucosal MBF significantly increased (+19%) compared with control (P = 0.033). Although hepatic MBF increased (+42% from baseline), this did not differ from control. In order to maintain a constant central venous pressure and MAP, fluid loading and norepinephrine (P < 0.01) were increased. Acid-base status was not altered by SNP. CONCLUSIONS: In a resuscitated porcine model of the early phase of septic shock, SNP improved ileal mucosal MBF but required a concomitant increase in fluid and norepinephrine supplements to maintain constant systemic haemodynamic parameters.


Assuntos
Nitroprussiato/farmacologia , Choque Séptico/fisiopatologia , Circulação Esplâncnica/efeitos dos fármacos , Vasodilatadores/farmacologia , Equilíbrio Ácido-Base/efeitos dos fármacos , Animais , Modelos Animais de Doenças , Avaliação Pré-Clínica de Medicamentos/métodos , Feminino , Íleo/irrigação sanguínea , Mucosa Intestinal/irrigação sanguínea , Circulação Hepática/efeitos dos fármacos , Microcirculação/efeitos dos fármacos , Fluxo Sanguíneo Regional/efeitos dos fármacos , Respiração Artificial , Choque Séptico/terapia , Sus scrofa
11.
Surg Endosc ; 22(8): 1871-5, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18163167

RESUMO

BACKGROUND: Endoscopic neck surgery is requested by an increasing number of patients. The access trauma of the axillary, breast, and chest approaches is greater than with open or video-assisted surgery. The authors tested the feasibility of the sublingual transoral access, which they believe is the most promising minimally invasive endoscopic access to the thyroid gland from outside the neck region. METHODS: The sublingual transoral access was first evaluated in two fresh human cadavers. An experimental investigation then was performed using a porcine model. A total of 10 endoscopic transoral thyroidectomies were performed in 10 pigs using a modified axilloscope with an obturator, ultrasonic scissors, and a neuromonitoring system to identify the recurrent laryngeal nerve. RESULTS: A complete transoral thyroid resection was achieved with both the human cadavers and all the living pigs. Despite the complexity of the anatomic region, the transoral procedure was astonishingly easy to perform. In the animal study, the time from the introduction of the obturator just above the larynx to its removal was 59 s. The average overall operation time was 50 min. The neuromonitoring system permitted the regular function of the recurrent laryngeal nerves on both sides to be proved after removal of the thyroid gland. The pigs were observed for another 2 h after the operation. No complications occurred during the operation or afterward. CONCLUSIONS: Endoscopic transoral thyroid resection is possible. It proved to be a safe procedure in living pigs and astonishingly easy to perform. The results may be helpful for thyroid resections in humans using a similar access, as suggested by the thyroidectomies in human cadavers preceding this study.


Assuntos
Endoscopia/métodos , Boca/cirurgia , Tireoidectomia/métodos , Animais , Cadáver , Estudos de Viabilidade , Humanos , Nervos Laríngeos/fisiopatologia , Período Pós-Operatório , Suínos , Tireoidectomia/instrumentação , Fatores de Tempo , Língua
12.
Chem Commun (Camb) ; 53(7): 1273-1276, 2017 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-28067354

RESUMO

The aggregation promoter heparin is commonly used to study the aggregation kinetics and biophysical properties of protein amyloids. However, the underlying mechanism for amyloid promotion by heparin remains poorly understood. In the case of the neuropeptide ß-endorphin that can reversibly adopt a functional amyloid form in nature, aggregation in the presence of heparin leads to a loss of function. Applying correlative optical super-resolution microscopy methods, we show that heparin incorporates into emerging ß-endorphin fibrils forming an integral component and is essential for amyloid templating. This will have direct implications on ß-endorphin's normal physiological function and raises concerns on the biological relevance of heparin-promoted amyloid models.


Assuntos
Peptídeos beta-Amiloides/química , Amiloide/química , Heparina/química , Agregados Proteicos , Agregação Patológica de Proteínas , beta-Endorfina/química , Microscopia
13.
Opt Express ; 14(12): 5456-67, 2006 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-19516711

RESUMO

We describe the application of wide-field frequency domain Fluorescence Lifetime Imaging Microscopy (FLIM) to imaging in microfluidic devices. FLIM is performed using low cost, intensity modulated Light Emitting Diodes (LEDs) for illumination. The use of lifetime imaging for quantitative analysis within such devices is demonstrated by mapping the molecular diffusion of iodide ions across a microchannel.

14.
Artigo em Inglês | MEDLINE | ID: mdl-16503188

RESUMO

This paper reports on the use of (130)Te(2) absorption lines in active laser-locking, and in frequency referencing, of the emission of a violet extended cavity diode laser with a wavelength of around 410 nm. We note the existence of closely spaced tellurium absorption lines, suitable for referencing purposes in gas sensing applications, at wavelengths below the lower limit (417 nm) of the spectral region covered by the tellurium atlas [J. Cariou, P. Luc, Atlas du spectre d'Absorption de la Molecule de Tellure, CNRS, Paris, 1980]. The absolute positions of the lines in the acquired spectra were estimated by comparison to a simultaneously acquired fluorescence spectrum of atomic indium, and were identified using calculations based on fundamental spectroscopic data. The laser frequency was stabilised within a range of 40 MHz, which is negligible compared to typical transition widths at atmospheric pressure.


Assuntos
Lasers , Espectrofotometria/instrumentação , Telúrio/análise , Tecnologia de Fibra Óptica , Fluorescência , Índio/química , Telúrio/efeitos da radiação
15.
Opt Express ; 8(5): 278-87, 2001 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-19417815

RESUMO

This paper presents advanced image analysis methods for extracting information from high speed Planar Laser Induced Fluorescence (PLIF) data obtained from turbulent flames. The application of non-linear anisotropic diffusion filtering and of Active Contour Models (Snakes) is described to isolate flame boundaries. In a subsequent step, the detected flame boundaries are tracked in time using a frequency domain contour interpolation scheme. The implementations of the methods are described and possible applications of the techniques are discussed.

16.
Endocr Pract ; 2(3): 191-2, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-15251538

RESUMO

OBJECTIVE: To describe the first reported case of a death that occurred as a result of chlorpropamide-induced cholestatic liver disease. METHODS: We review the clinical and laboratory details of an 81-year-old man with type II diabetes mellitus, who was hospitalized because of nausea, vomiting, and jaundice. RESULTS: The patient had been taking a sulfonylurea (chlorpropamide, 250 mg orally three times a day) for 2 months. On initial assessment, the patient was noted to have cutaneous and scleral icterus and an erythematous maculopapular rash on the torso. The alkaline phosphatase level was substantially increased, and the transaminases were mildly increased. Use of all medications was discontinued. In the hospital, the patient's status rapidly deteriorated, and death ensued after cardiopulmonary arrest on day 6. CONCLUSION: The findings were consistent with a hypersensitivity reaction to chlorpropamide that ultimately resulted in fulminant cholestatic liver disease and death.

18.
Dtsch Med Wochenschr ; 132(47): 2495-9, 2007 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-18027323

RESUMO

BACKGROUND AND OBJECTIVE: In Germany, taking blood samples is generally considered to be the task of a physician. Doctors can legally delegate the taking of blood samples to nurses only after having made sure that they are qualified for this task. In daily routine at many hospitals blood samples are almost always taken by doctors and nearly exclusively by qualified assistants in the medical practices of resident doctors. METHODS: Answers to standardized questionnaires by 538 nurses were analysed for the way in which five German hospitals of a corporate group of hospitals dealt with this task, and what circumstances and reasons played a role. RESULTS: It was found that in the East German states blood samples were significantly more often taken by nurses than in the rest of the Federal Republic. 476 of all nurses questioned (89.14% of total) considered themselves capable of taking blood samples. However taking these samples has remained part of doctors' daily routine. CONCLUSION: In times of necessary cost cutting and a growing lack of physicians it would be reasonable to delegate this task to nurses who have been specifically trained for it.


Assuntos
Coleta de Amostras Sanguíneas , Hospitais , Papel do Profissional de Enfermagem , Papel do Médico , Coleta de Amostras Sanguíneas/métodos , Coleta de Amostras Sanguíneas/normas , Alemanha , Hospitais/tendências , Humanos , Recursos Humanos
19.
J Microsc ; 227(Pt 3): 203-15, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17760615

RESUMO

Spectrofluorometric imaging microscopy is demonstrated in a confocal microscope using a supercontinuum laser as an excitation source and a custom-built prism spectrometer for detection. This microscope system provides confocal imaging with spectrally resolved fluorescence excitation and detection from 450 to 700 nm. The supercontinuum laser provides a broad spectrum light source and is coupled with an acousto-optic tunable filter to provide continuously tunable fluorescence excitation with a 1-nm bandwidth. Eight different excitation wavelengths can be simultaneously selected. The prism spectrometer provides spectrally resolved detection with sensitivity comparable to a standard confocal system. This new microscope system enables optimal access to a multitude of fluorophores and provides fluorescence excitation and emission spectra for each location in a 3D confocal image. The speed of the spectral scans is suitable for spectrofluorometric imaging of live cells. Effects of chromatic aberration are modest and do not significantly limit the spatial resolution of the confocal measurements.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Microscopia Confocal/métodos , Espectrometria de Fluorescência/métodos , Osteossarcoma/ultraestrutura , Rizoma/citologia
20.
J Microsc ; 224(Pt 2): 166-80, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17204064

RESUMO

High brightness light emitting diodes are an inexpensive and versatile light source for wide-field frequency-domain fluorescence lifetime imaging microscopy. In this paper a full calibration of an LED based fluorescence lifetime imaging microscopy system is presented for the first time. A radio-frequency generator was used for simultaneous modulation of light emitting diode (LED) intensity and the gain of an intensified charge coupled device (CCD) camera. A homodyne detection scheme was employed to measure the demodulation and phase shift of the emitted fluorescence, from which phase and modulation lifetimes were determined at each image pixel. The system was characterized both in terms of its sensitivity to measure short lifetimes (500 ps to 4 ns), and its capability to distinguish image features with small lifetime differences. Calibration measurements were performed in quenched solutions containing Rhodamine 6G dye and the results compared to several independent measurements performed with other measurement methodologies, including time correlated single photon counting, time gated detection, and acousto optical modulator (AOM) based modulation of excitation sources. Results are presented from measurements and simulations. The effects of limited signal-to-noise ratios, baseline drifts and calibration errors are discussed in detail. The implications of limited modulation bandwidth of high brightness, large area LED devices ( approximately 40 MHz for devices used here) are presented. The results show that phase lifetime measurements are robust down to sub ns levels, whereas modulation lifetimes are prone to errors even at large signal-to-noise ratios. Strategies for optimizing measurement fidelity are discussed. Application of the fluorescence lifetime imaging microscopy system is illustrated with examples from studies of molecular mixing in microfluidic devices and targeted drug delivery research.


Assuntos
Luz , Microscopia de Fluorescência/instrumentação , Microscopia de Fluorescência/normas , Calibragem/normas , Doxorrubicina/metabolismo , Corantes Fluorescentes , Células HeLa/metabolismo , Humanos , Rodaminas , Coloração e Rotulagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA