1.
Neural Plast ; 2021: 6641506, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33777135

RESUMO

Flaccid paralysis in the upper extremity is a severe motor impairment after stroke, which exists for weeks, months, or even years. Electroacupuncture treatment is one of the most widely used TCM therapeutic interventions for poststroke flaccid paralysis. However, the response to electroacupuncture in different durations of flaccid stage poststroke as well as in the topological configuration of the cortical network remains unclear. The objectives of this study are to explore the disruption of the cortical network in patients in different durations of flaccid stage and observe dynamic network reorganization during and after electroacupuncture. Resting-state networks were constructed from 18 subjects with flaccid upper extremity by partial directed coherence (PDC) analysis of multichannel EEG. They were allocated to three groups according to time after flaccid paralysis: the short-duration group (those with flaccidity for less than two months), the medium-duration group (those with flaccidity between two months and six months), and the long-duration group (those with flaccidity over six months). Compared with short-duration flaccid subjects, weakened effective connectivity was presented in medium-duration and long-duration groups before electroacupuncture. The long-duration group has no response in the cortical network during electroacupuncture. The global network measures of EEG data (sPDC, mPDC, and N) indicated that there was no significant difference among the three groups. These results suggested that the network connectivity reduced and weakly responded to electroacupuncture in patients with flaccid paralysis for over six months. These findings may help us to modulate the formulation of electroacupuncture treatment according to different durations of the flaccid upper extremity.


Assuntos
Eletroacupuntura/métodos , Eletroencefalografia/métodos , Paralisia/fisiopatologia , Paralisia/terapia , Acidente Vascular Cerebral/fisiopatologia , Acidente Vascular Cerebral/terapia , Adulto , Idoso , Ritmo beta/fisiologia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paralisia/etiologia , Projetos Piloto , Acidente Vascular Cerebral/complicações
2.
Biosens Bioelectron ; 194: 113592, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34507098

RESUMO

Neural electrical interfaces are important tools for local neural stimulation and recording, which potentially have wide application in the diagnosis and treatment of neural diseases, as well as in the transmission of neural activity for brain-computer interface (BCI) systems. At the same time, magnetic resonance imaging (MRI) is one of the effective and non-invasive techniques for recording whole-brain signals, providing details of brain structures and also activation pattern maps. Simultaneous recording of extracellular neural signals and MRI combines two expressions of the same neural activity and is believed to be of great importance for the understanding of brain function. However, this combination makes requests on the magnetic and electronic performance of neural interface devices. MRI-compatibility refers here to a technological approach to simultaneous MRI and electrode recording or stimulation without artifacts in imaging. Trade-offs between materials magnetic susceptibility selection and electrical function should be considered. Herein, prominent trends in selecting materials of suitable magnetic properties are analyzed and material design, function and application of neural interfaces are outlined together with the remaining challenge to fabricate MRI-compatible neural interface.


Assuntos
Técnicas Biossensoriais , Artefatos , Encéfalo/diagnóstico por imagem , Eletricidade , Imageamento por Ressonância Magnética
3.
Biosens Bioelectron ; 99: 99-107, 2018 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-28743085

RESUMO

Engineering of neural interface with nanomaterials for high spatial resolution neural recording and stimulation is still hindered by materials properties and modification methods. Recently, poly(3,4-ethylene-dioxythiophene) (PEDOT) has been widely used as an electrode-tissue interface material for its good electrochemical property. However, cracks and delamination of PEDOT film under pulse stimulation are found which restrict its long-term applications. This paper develops a flexible electrochemical method about the co-deposition of graphene with PEDOT on microelectrode sites to enhance the long-term stability and improve the electrochemical properties of microelectrode. This method is unique and profound because it co-deposits graphene with PEDOT on microelectrode sites directly and avoids the harmful post reduction process. And, most importantly, significantly improved electrochemical performances of the modified microelectrodes (compared to PEDOT-GO) are demonstrated due to the large effective surface area, good conductivity and excellent mechanical property of graphene. Furthermore, the good mechanical stability of the composites is verified by ultrasonication and CV scanning tests. In-vivo acute implantation of the microelectrodes reveals the modified microelectrodes show higher recording performance than the unmodified ones. These findings suggest the composites are excellent candidates for the applications of neural interface.


Assuntos
Técnicas Biossensoriais , Grafite/isolamento & purificação , Neurônios/química , Compostos Bicíclicos Heterocíclicos com Pontes/química , Condutividade Elétrica , Grafite/química , Nanoestruturas/química , Neurônios/fisiologia , Polímeros/química
4.
Micromachines (Basel) ; 8(9)2017 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-30400473

RESUMO

With the rapid development of Micro-electro-mechanical Systems (MEMS) fabrication technologies, many microelectrodes with various structures and functions have been designed and fabricated for applications in biomedical research, diagnosis and treatment through electrical stimulation and electrophysiological signal recording. The flexible MEMS microelectrodes exhibit excellent characteristics in many aspects beyond stiff microelectrodes based on silicon or metal, including: lighter weight, smaller volume, better conforming to neural tissue and lower fabrication cost. In this paper, we reviewed the key technologies in flexible MEMS microelectrodes for neural interface in recent years, including: design and fabrication technology, flexible MEMS microelectrodes with fluidic channels and electrode⁻tissue interface modification technology for performance improvement. Furthermore, the future directions of flexible MEMS microelectrodes for neural interface were described, including transparent and stretchable microelectrodes integrated with multi-functional aspects and next-generation electrode⁻tissue interface modifications, which facilitated electrode efficacy and safety during implantation. Finally, we predict that the relationships between micro fabrication techniques, and biomedical engineering and nanotechnology represented by flexible MEMS microelectrodes for neural interface, will open a new gate to better understanding the neural system and brain diseases.

5.
Sci Rep ; 6: 26910, 2016 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-27229174

RESUMO

Implantable biomedical microdevices enable the restoration of body function and improvement of health condition. As the interface between artificial machines and natural tissue, various kinds of microelectrodes with high density and tiny size were developed to undertake precise and complex medical tasks through electrical stimulation and electrophysiological recording. However, if only the electrical interaction existed between electrodes and muscle or nerve tissue without nutrition factor delivery, it would eventually lead to a significant symptom of denervation-induced skeletal muscle atrophy. In this paper, we developed a novel flexible tubular microelectrode integrated with fluidic drug delivery channel for dynamic tissue implant. First, the whole microelectrode was made of biocompatible polymers, which could avoid the drawbacks of the stiff microelectrodes that are easy to be broken and damage tissue. Moreover, the microelectrode sites were circumferentially distributed on the surface of polymer microtube in three dimensions, which would be beneficial to the spatial selectivity. Finally, the in vivo results confirmed that our implantable tubular microelectrodes were suitable for dynamic electrophysiological recording and simultaneous fluidic drug delivery, and the electrode performance was further enhanced by the conducting polymer modification.


Assuntos
Sistemas de Liberação de Medicamentos/instrumentação , Eletrodos Implantados , Implantes Experimentais , Dispositivos Lab-On-A-Chip , Músculo Esquelético/inervação , Animais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Compostos Bicíclicos Heterocíclicos com Pontes/química , Compostos Bicíclicos Heterocíclicos com Pontes/farmacologia , Sobrevivência Celular/efeitos dos fármacos , Impedância Elétrica , Estimulação Elétrica , Feminino , Microeletrodos , Músculo Esquelético/irrigação sanguínea , Músculo Esquelético/efeitos dos fármacos , Músculo Esquelético/cirurgia , Células PC12 , Polímeros/química , Polímeros/farmacologia , Implantação de Prótese/métodos , Ratos , Ratos Sprague-Dawley , Xilenos/química , Xilenos/farmacologia
6.
Artigo em Inglês | MEDLINE | ID: mdl-25570000

RESUMO

Iridium oxide has been widely used in neural recording and stimulation due to its good stability and large charge storage capacity (CSC). In general, the iridium oxide film used in the electrophysiological application can be grouped into three principal classifications: sputtering iridium oxide film (SIROF), activated iridium oxide film (AIROF) and electrodeposited iridium oxide film (EIROF). Although these kinds of iridium oxide all can remarkably reduce the impedance and increase the CSC of the microelectrode, they also exhibit markedly differences in electrochemical performances. After activation, the CSC of EIROF is 68.20 mC/cm(2), which is 88.7 % larger than that of the SIROF and 67.6 % larger than that of the AIROF. The impedance at 1 kHz of the three kinds of iridium oxide microelectrode is around 4000 ohm, it is acceptable for the neural interface application. The phase at 1 kHz of the AIROF microelectrode is the largest which is -6.1 degree, about 22.6 % of the SIROF and 44.5 % of the EIROF.


Assuntos
Neuroestimuladores Implantáveis , Irídio/química , Galvanoplastia , Microeletrodos
7.
Artigo em Inglês | MEDLINE | ID: mdl-25571594

RESUMO

With the rapidly developed micromachining technology, various kinds of sophisticated microelectrodes integrated with micro fluidic channels are design and fabricated for not only electrophysiological recording and stimulation, but also chemical drug delivery. As many efforts have been devoted to develop rigid microprobes for neural research of brain, few researchers concentrate on fabrication of flexible microelectrodes for intramuscular electrophysiology and chemical interfacing. Since crude wire electrodes still prevail in functional electrical stimulation (FES) and electromyography (EMG) recording of muscle, here we introduce a flexible micro tube electrode combining electrical and chemical pathway. The proposed micro tube electrode is manufactured based on polymer capillary, which provide circumferential electrode site contacting with electro-active tissue and is easy to manufactured with low cost.


Assuntos
Sistemas de Liberação de Medicamentos/instrumentação , Fenômenos Eletrofisiológicos , Músculo Esquelético/fisiologia , Animais , Impedância Elétrica , Eletroquímica , Eletromiografia , Desenho de Equipamento , Injeções Intramusculares , Microeletrodos , Polímeros , Coelhos
8.
Artigo em Inglês | MEDLINE | ID: mdl-25570271

RESUMO

Owing to interacting with the living tissue directly, the electrode-tissue interface largely determines the performance of the whole bioelectronics devices. The miniaturization of biomedical electronic components requires interface materials to possess properties including excellent electrical performance, good biocompatibility and compatibility with microelectronic fabrication process. Considering the unique characteristics and wide applications in biomedical domain of conducting polymer and graphene, composite film consists of poly(3,4-ethylenedioxythiophene) (PEDOT) and graphene oxide (GO) is proposed as electrode-tissue interface in this work. The facilely electrochemically synthesized PEDOT/GO coating on microelectrodes shows low impedance, high charge storage capacity and good biocompatibility to act as electrode-tissue interface. As a result, the composite film is a potential biomaterial as electrode-tissue interface for tissue engineering and further implantable electrophysiological devices.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes/química , Grafite/química , Óxidos/química , Polímeros/química , Engenharia Tecidual , Animais , Forma Celular , Espectroscopia Dielétrica , Eletrodos , Camundongos , Células NIH 3T3 , Células PC12 , Coelhos , Ratos , Espectrofotometria Ultravioleta
9.
Biomaterials ; 35(7): 2120-9, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24333027

RESUMO

One of the most significant components for implantable bioelectronic devices is the interface between the microelectrodes and the tissue or cells for disease diagnosis or treatment. To make the devices work efficiently and safely in vivo, the electrode-tissue interface should not only be confined in micro scale, but also possesses excellent electrochemical characteristic, stability and biocompatibility. Considering the enhancement of many composite materials by combining graphene oxide (GO) for its multiple advantages, we dope graphene oxide into poly(3,4-ethylenedioxythiophene) (PEDOT) forming a composite film by electrochemical deposition for electrode site modification. As a consequence, not only the enlargement of efficient surface area, but also the development of impedance, charge storage capacity and charge injection limit contribute to the excellent electrochemical performance. Furthermore, the stability and biocompatibility are confirmed by numerously repeated usage test and cell proliferation and attachment examination, respectively. As electrode-tissue interface, this biomaterial opens a new gate for tissue engineering and implantable electrophysiological devices.


Assuntos
Eletrodos , Grafite/química , Nanocompostos , Óxidos/química , Polímeros/química , Animais , Materiais Biocompatíveis , Microscopia Eletrônica de Varredura , Células PC12 , Espectroscopia Fotoeletrônica , Ratos , Espectroscopia de Infravermelho com Transformada de Fourier
SELEÇÃO DE REFERÊNCIAS