Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 14(3)2024 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-38337801

RESUMO

Continuous Thermodilution is a novel method of quantifying coronary flow (Q) in mL/min. To account for variability of Q within the cardiac cycle, the trace is smoothened with a 2 s moving average filter. This can sometimes be ineffective due to significant heart rate variability, ventricular extrasystoles, and deep inspiration, resulting in a fluctuating temperature trace and ambiguity in the location of the "steady state". This study aims to assess whether a longer moving average filter would smoothen any fluctuations within the continuous thermodilution traces resulting in improved interpretability and reproducibility on a test-retest basis. Patients with ANOCA underwent repeat continuous thermodilution measurements. Analysis of traces were performed at averages of 10, 15, and 20 s to determine the maximum acceptable average. The maximum acceptable average was subsequently applied as a moving average filter and the traces were re-analysed to assess the practical consequences of a longer moving average. Reproducibility was then assessed and compared to a 2 s moving average. Of the averages tested, only 10 s met the criteria for acceptance. When the data was reanalysed with a 10 s moving average filter, there was no significant improvement in reproducibility, however, it resulted in a 12% diagnostic mismatch. Applying a longer moving average filter to continuous thermodilution data does not improve reproducibility. Furthermore, it results in a loss of fidelity on the traces, and a 12% diagnostic mismatch. Overall, current practice should be maintained.

2.
Int J Cardiol Heart Vasc ; 51: 101374, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38496256

RESUMO

Background: The assessment of coronary microvascular dysfunction (CMD) using invasive methods is a field of growing interest, however the preferred method remains debated. Bolus and continuous thermodilution are commonly used methods, but weak agreement has been observed in patients with angina with non-obstructive coronary arteries (ANOCA). This study examined their agreement in revascularized acute coronary syndromes (ACS) and chronic coronary syndromes (CCS) patients. Objective: To compare bolus thermodilution and continuous thermodilution indices of CMD in revascularized ACS and CCS patients and assess their diagnostic agreement at pre-defined cut-off points. Methods: Patients from two centers underwent paired bolus and continuous thermodilution assessments after revascularization. CMD indices were compared between the two methods and their agreements at binary cut-off points were assessed. Results: Ninety-six patients and 116 vessels were included. The mean age was 64 ± 11 years, and 20 (21 %) were female. Overall, weak correlations were observed between the Index of Microcirculatory Resistance (IMR) and continuous thermodilution microvascular resistance (Rµ) (rho = 0.30p = 0.001). The median coronary flow reserve (CFR) from continuous thermodilution (CFRcont) and bolus thermodilution (CFRbolus) were 2.19 (1.76-2.67) and 2.55 (1.50-3.58), respectively (p < 0.001). Weak correlation and agreement were observed between CFRcont and CFRbolus (rho = 0.37, p < 0.001, ICC 0.228 [0.055-0.389]). When assessed at CFR cut-off values of 2.0 and 2.5, the methods disagreed in 41 (35 %) and 45 (39 %) of cases, respectively. Conclusions: There is a significant difference and weak agreement between bolus and continuous thermodilution-derived indices, which must be considered when diagnosing CMD in ACS and CCS patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA