1.
Respiration ; 103(5): 268-274, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38471486

RESUMO

INTRODUCTION: Today, the increasing number of incidentally detected peripheral pulmonary lesions (PPLs) within and outside lung cancer screening trials is a diagnostic challenge. This fact encourages further improvement of diagnostic procedures to increase the diagnostic yield of transbronchial biopsy, which has been shown to have a low complication rate. The purpose of this study was to evaluate the safety and feasibility of a new ultrathin 1.1 cryoprobe that can be placed through an ultrathin bronchoscope (UTB) using fluoroscopy and radial endobronchial ultrasonography (rEBUS) navigation for assessing PPLs. METHODS: Thirty-five patients with PPL less than 4 cm in diameter were prospectively enrolled to receive transbronchial cryobiopsies (TBCBs) using the ultrathin 1.1-mm cryoprobe. Navigation to the PPL was accomplished with the UTB. Under rEBUS and fluoroscopy guidance up to 4 cryobiopsies were obtained. The sample sizes of the biopsies were compared to a historic collective derived from a 1.9-mm cryoprobe and standard forceps. The feasibility and safety of the procedure, the cumulative and overall diagnostic yield, and the cryobiopsy sizes were evaluated. RESULTS: After detection with the rEBUS, TBCB was collected from 35 PPLs, establishing a diagnosis in 25 cases, corresponding to an overall diagnostic yield of 71.4%. There was no difference in diagnostic yield for PPL <20 mm or ≥20 mm. All cryobiopsies were representative with a mean tissue area of 11.9 ± 4.3 mm2, which was significantly larger compared to the historic collective (p = 0.003). Six mild and four moderate bleeding events and 1 case of pneumothorax were observed. CONCLUSIONS: Using the ultrathin 1.1-mm cryoprobe combined with an UTB for rEBUS-guided TBCB of PPL is feasible and safe. This diagnostic approach improves bronchoscopic techniques for diagnosing peripheral lung lesions and may contribute to improve diagnosis of lung cancer even in small PPL.


Assuntos
Broncoscopia , Criocirurgia , Endossonografia , Estudos de Viabilidade , Neoplasias Pulmonares , Humanos , Broncoscopia/métodos , Broncoscopia/instrumentação , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Criocirurgia/métodos , Criocirurgia/instrumentação , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico , Estudos Prospectivos , Endossonografia/métodos , Endossonografia/instrumentação , Fluoroscopia/métodos , Biópsia Guiada por Imagem/métodos , Biópsia Guiada por Imagem/instrumentação , Ultrassonografia de Intervenção/métodos , Ultrassonografia de Intervenção/instrumentação , Biópsia/métodos , Biópsia/instrumentação , Idoso de 80 Anos ou mais
2.
Respir Med ; 223: 107559, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38350511

RESUMO

BACKGROUND: Patients with chronic obstructive pulmonary disease (COPD) often suffer from cachexia and malnutrition. Less is known about body composition and nutritional behaviour in patients with advanced COPD and pulmonary emphysema. METHODS: We performed a single-center prospective analysis of patients with COPD GOLD III/IV. Metabolic parameters, dietary and exercise behavior, lung function, exercise capacity and body composition by bioelectrical impedance analysis (BIA) were analyzed. Patients with severe emphysema (emphysema index [EI] >20%) were compared to patients with mild emphysema (EI ≤ 20%). RESULTS: A total of 121 patients (45.5% female, mean age 64.8 ± 8.1 years, mean FEV1 31.0 ± 8.6%, mean RV 234.7 ± 50.6%) were analyzed, of whom 14.1% were underweight. Only 5% of the patients substituted protein and only about 1/3 performed regular exercise training. BIA showed an unfavourable body composition: body fat ↑, ECM/BCM-index ↑, phase angle ↓ (5.0 ± 0.9°), cell percentage ↓, FFMI (fat-free mass index) ↓. The 94 patients with severe emphysema (mean EI 36.6 ± 8.5%) had lower body-mass-index (22.8 ± 4.3 vs. 31.1 ± 5.8 kg/m2, p < 0.001), FFMI, body weight and body fat, but did not differ significantly in the quality of body composition (e.g. phase angle). Their lipid and glucose metabolism were even better than in mild emphysema patients. CONCLUSION: The finding of significantly lower BMI but similar body composition and better metabolic status in severe emphysema patients needs further investigation. However, it should not distract from the necessity to implement dietary and exercise recommendations for advanced COPD patients.


Assuntos
Enfisema , Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Enfisema Pulmonar/complicações , Impedância Elétrica , Estado Nutricional , Doença Pulmonar Obstrutiva Crônica/complicações , Composição Corporal , Índice de Massa Corporal