Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Neuromodulation ; 21(7): 694-699, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30152898

RESUMO

BACKGROUND: Long-term outcome of sacral nerve modulation (SNM) patients after implanted pulse generator (IPG) change for fecal incontinence (FI) is unknown. This study reported the outcome and long-term satisfaction after a change of an exhausted IPG, questioning the need to concurrently change the electrode and looking for factors involved in the maintenance of treatment efficiency. METHODS: Patients with fecal incontinence and with a Medtronic IPG implanted in a single center (2001-2016) were prospectively followed up. Satisfaction was graded according to a patient-reported outcome measure from 0 to 10. A pre- and postreplacement FI severity score (Cleveland Clinic Fecal Incontinence Score) and Fecal Incontinence Quality of Life questionnaire were also collected. RESULTS: In 170 patients with SNM, 39 had an IPG replacement. At a median of 29 month after replacement, 32 and 7 patients reported respectively a similar and reduced satisfaction (7.6 ± 1.62 vs. 5.5 ± 0.87), p < .001. Satisfied patients were younger (65 years vs. 76 years, p < .001). Cleveland Clinic Fecal Incontinence Scores were not significantly different, but the satisfied group had a significantly better Fecal Incontinence Quality of Life score (p = .047). Only 5 patients needed an electrode change at the time of the IPG replacement or later. CONCLUSIONS: Patient satisfaction and efficiency remain high after IPG replacement. Older age has a negative impact on the outcome. Electrode replacement is rarely required and does not need to be performed routinely when an IPG is exhausted. CONFLICT OF INTEREST: Paul-Antoine Lehur has a consulting agreement with Medtronic SA. This had no impact with the results of the study. The other authors have no conflict of interests to declare.


Assuntos
Fontes de Energia Elétrica , Terapia por Estimulação Elétrica/instrumentação , Terapia por Estimulação Elétrica/métodos , Eletrodos Implantados , Incontinência Fecal/terapia , Nervos Espinhais/fisiologia , Idoso , Idoso de 80 Anos ou mais , Incontinência Fecal/psicologia , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Qualidade de Vida , Estudos Retrospectivos , Autorrelato
2.
Int J Colorectal Dis ; 31(2): 439-44, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26552785

RESUMO

PURPOSE: The efficacy of sacral nerve stimulation in faecal incontinence relies on an implanted pulse generator known to have a limited lifespan. The long-term use of sacral nerve stimulation raises concerns about the true lifespan of generators. The aim of the study was to assess the lifespan of sacral nerve stimulation implanted pulse generators in daily practice, and the outcome of exhausted generator replacement, in faecal incontinent patients. METHODS: Faecal incontinent patients with pulse generators (Medtronic Interstim™ or InterstimII™) implanted in a single centre from 2001 to 2014 were prospectively followed up. Generator lifespan was measured according to the Kaplan-Meier method. Patients with a generator explanted/turned off before exhaustion were excluded. Morbidity of exhausted generator replacement and the outcome (Cleveland Clinic Florida Faecal Incontinence (CCF-FI) and Faecal Incontinence Quality of Life (FIQL) scores) were recorded. RESULTS: Of 135 patients with an implanted pulse generator, 112 (InterstimII 66) were included. Mean follow-up was 4.9 ± 2.8 years. The generator reached exhaustion in 29 (26%) cases. Overall median lifespan of an implanted pulse generator was approximately 9 years (95% CI 8-9.2). Interstim and InterstimII 25th percentile lifespan was 7.2 (CI 6.4-8.3) and 5 (CI 4-not reached) years, respectively. After exhaustion, generators were replaced, left in place or explanted in 23, 2 and 4 patients, respectively. Generator replacement was virtually uneventful. CCF-FI/FIQL scores remained unchanged after generator replacement (CCF-FI 8 ± 2 vs 7 ± 3; FIQL 3 ± 0.6 vs 3 ± 0.5; p = ns). CONCLUSION: In this study, the implanted pulse generator observed median lifespan was 9 years. After exhaustion, generators were safely and efficiently replaced. The study also gives insight into long-term needs and costs of sacral nerve stimulation (SNS) therapy.


Assuntos
Terapia por Estimulação Elétrica/instrumentação , Eletrodos Implantados , Incontinência Fecal/terapia , Sacro/inervação , Nervos Espinhais , Análise Custo-Benefício , Terapia por Estimulação Elétrica/economia , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Qualidade de Vida , Fatores de Tempo
3.
Ann Surg Oncol ; 21(11): 3534-40, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24823444

RESUMO

BACKGROUND: The objectives of this study were to evaluate, in mild primary hyperparathyroidism (pHPT) patients, the quality of life (QoL) using the SF-36 questionnaire before and after parathyroidectomy and to detect preoperatively patients who benefit the most from surgery. Most pHPT patients present a mild pHPT defined by calcemia ≤11.4 mg/dL. For these patients, there is debate about whether they should be managed with surveillance, medical therapy, or surgery. METHODS: A prospective multicenter study investigated QoL (SF-36) in patients with mild pHPT before and after parathyroidectomy in four university hospitals. Laboratory results and SF-36 scores were obtained preoperatively and postoperatively (3, 6, and 12 months). RESULTS: One hundred sixteen patients were included. After surgery, the biochemical cure rate was 98%. Preoperatively, the mental component summary and the physical component summary (PCS) were 38.69 of 100 and 39.53 of 100, respectively. At 1 year, the MCS and the PCS were 41.29 of 100 and 42.03 of 100. The subgroup analysis showed a more significant improvement in patients < 70 years and with calcemia ≥10.4 mg/dL. Postoperative PCS was correlated with age and preoperative PCS: variation = 32.11 - 0.21 × age - 0.4 × preoperative PCS. Men did not improve their MCS postoperatively. Only women with a preoperative MCS <43.6 of 100 showed postoperative improvement. CONCLUSIONS: This study showed, in patients with mild pHPT, an improvement of QoL 1 year after parathyroidectomy. Patients <70 years and with calcemia ≥10.4 mg/dL had a more significant improvement.


Assuntos
Hiperparatireoidismo Primário/psicologia , Hiperparatireoidismo Primário/cirurgia , Paratireoidectomia , Qualidade de Vida , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Período Pós-Operatório , Prognóstico , Estudos Prospectivos , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA