Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Am Heart Assoc ; 12(3): e8189, 2023 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-36734351

RESUMO

Background Cerebral microbleeds (CMBs) are increasingly recognized as "covert" brain lesions indicating increased risk of future neurological events. However, data on CMBs in patients undergoing catheter-based structural heart interventions are scarce. Therefore, we assessed occurrence and predictors of new CMBs in patients undergoing catheter-based left atrial appendage closure and percutaneous mitral valve repair using the MitraClip System. Methods and Results We conducted an exploratory analysis using data derived from 2 prospective, observational studies. Eligible patients underwent cerebral magnetic resonance imaging (3 Tesla) examinations and cognitive tests (using the Montreal Cognitive Assessment) before and after catheter-based left atrial appendage closure and percutaneous mitral valve repair. Forty-seven patients (53% men; median age, 77 years) were included. New CMBs occurred in 17 of 47 patients (36%) following catheter-based structural heart interventions. Occurrences of new CMBs did not differ significantly between patients undergoing catheter-based left atrial appendage closure and percutaneous mitral valve repair (7/25 versus 10/22; P=0.348). In univariable analysis, longer procedure time was significantly associated with new CMBs. Adjustment for heparin attenuated this association (adjusted odds ratio [per 30 minutes]: 1.77 [95% CI, 0.92-3.83]; P=0.090). Conclusions New CMBs occur in approximately one-third of patients after catheter-based left atrial appendage closure and percutaneous mitral valve repair using the MitraClip System. Our data suggest that longer duration of the procedure may be a risk factor for new CMBs. Future studies in larger populations are needed to further investigate their clinical relevance. Clinical Trial Registration German Clinical Trials Register: DRKS00010300 (https://drks.de/search/en/trial/DRKS00010300); ClinicalTrials.gov : NCT03104556 (https://clinicaltrials.gov/ct2/show/NCT03104556?term=NCT03104556&draw=2&rank=1).


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Mitral , Idoso , Feminino , Humanos , Masculino , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Catéteres/efeitos adversos , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/etiologia , Imageamento por Ressonância Magnética , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Estudos Prospectivos , Resultado do Tratamento
2.
EuroIntervention ; 18(2): e160-e168, 2022 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-34916177

RESUMO

BACKGROUND: New ischaemic brain lesions on magnetic resonance imaging (MRI) are reported in up to 86% of patients after transcatheter edge-to-edge repair of the mitral valve (TEER-MV). Knowledge of the exact procedural step(s) that carry the highest risk for cerebral embolisation may help to further improve the procedure. AIMS: The aim of this study was to identify the procedural step(s) that are associated with an increased risk of cerebral embolisation during TEER-MV with the MitraClip system. Furthermore, the risk of overt stroke and silent brain ischaemia after TEER-MV was assessed. METHODS: In this prospective, pre-specified observational study, all patients underwent continuous transcranial Doppler examination during TEER-MV to detect microembolic signals (MES). MES were assigned to specific procedural steps: (1) transseptal puncture and placement of the guide, (2) advancing and adjustment of the clip in the left atrium, (3) device interaction with the MV, and (4) removal of the clip delivery system and the guide. Neurological examination using the National Institutes of Health Stroke Scale (NIHSS) and cerebral MRI were performed before and after TEER-MV. RESULTS: Fifty-four patients were included. The number of MES differed significantly between the procedural steps with the highest numbers observed during device interaction with the MV. Mild neurological deterioration (NIHSS ≤3) occurred in 9/54 patients. New ischaemic lesions were detected in 21/24 patients who underwent MRI. Larger infarct volume was significantly associated with neurological deterioration. CONCLUSIONS: Cerebral embolisation is immanent to TEER-MV and predominantly occurs during device interaction with the MV. Improvements to the procedure may focus on this procedural step.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Acidente Vascular Cerebral , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA