Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Chromatogr A ; 956(1-2): 279-86, 2002 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-12108662

RESUMO

A new application of capillary electrophoresis (CE) for measuring inorganic anions in hailstones was carried out. Five hailstone specimens were collected from large blocks of ice that fell in January 2000 in some provinces of Spain. Sample handling and preparation procedures were performed with care. CE analysis of anions was carried out using indirect UV detection at 254 nm with a negative power supply (-15 kV) and hydrostatic injection (10 cm for 30 s) at 35 degrees C. Anion separation was completed in less than 4 min. The working electrolyte consisted of 4.7 mM sodium chromate, 4.0 mM OFM-OH (tetradecyltrimethylammonium hydroxide), 10 mM CHES [2-(N-cyclohexylamino)ethanesulfonic acid], and 0.1 mM calcium gluconate (pH 9.1). Good repeatability of migration times after eight injections (<0.7% RSD), adequate linearity responses (r2>0.9) as well as satisfactory detection limits (<0.35 ppm) were achieved. The analytical results provided by CE were compared with those obtained by traditional wet-chemical (WCH) methods. Most of the results obtained by CE were consistent with those of WCH, except for one sample.


Assuntos
Ânions/análise , Eletroforese Capilar/métodos , Gelo/análise , Compostos Inorgânicos/análise , Tempo (Meteorologia) , Atmosfera , Sensibilidade e Especificidade
3.
Fresenius J Anal Chem ; 368(6): 601-6, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11228710

RESUMO

The developed strategy permits determination in three steps of sixty-seven elements using inductively coupled plasma mass spectrometry (ICP-MS). Sodium, Mg, Si, S, Cl, K, and Ca are determined in a first step; B, Al, P, Cr, Fe, Mn, Ni, Cu, Zn, As, Se, Ag, Cd, Sb, Ba, Hg, and Pb are determined in a second step; and Li, Be, Ti, V, Co, Ga, Ge, Br, Rb, Sr, Y, Zr, Nb, Mo, Sn, Te, I, Cs, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, W, Pt, Au, Tl, Bi, Th, and U are analyzed in a third step. The figures of merit obtained are adequate to carry out water quality monitoring and other hydrochemical studies, such those based in the application of hydrochemical fingerprinting to water management.


Assuntos
Água Doce/análise , Poluentes Químicos da Água/análise , Calibragem , Elementos Químicos , Monitoramento Ambiental/métodos , Indicadores e Reagentes , Espectrometria de Massas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA