Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Subst Use Misuse ; 52(7): 950-958, 2017 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-28426360

RESUMO

Pharmaceutical cognitive enhancement (PCE) represents the non-medical use of prescribed medication for the improvement of cognitive functioning and academic performance. Although there are some studies about PCE prevalence, it is less clear how users and non-users of PCE substances differ with respect to their positive and negative student experiences (e.g. academic burnout and engagement with studies) and in social cognitive variables that relate to decision-making and self-regulation of PCE use. The present study assessed whether students with different experiences of PCE substance use displayed differences in academic burnout, study engagement, and social cognitive variables relevant to PCE use. Three hundred and forty-seven university students (mean age (M) = 22.15 years, SD = 1.69; 54% females) completed a battery of anonymous questionnaires on academic burnout, engagement with studies, social cognitive variables relevant to PCE use, and self-reported use of PCE substances and non-prescribed nutritional supplements. Three user groups emerged, namely non-users (51.9%, n = 180), single users of non-prescribed dietary supplements (25.4%, n = 88), and dual users of both non-prescribed dietary supplements and PCE (22.8%, n = 79). Multivariate analysis of variance indicated significant differences among the three user groups in intentions, attitudes, social norms, and anticipated regret toward PCE use. No significant differences were observed with respect to academic burnout and work engagement. The findings show that university students may engage in PCE use independent of their student experiences. Rather, a chemically assisted performance enhancement mindset seems to differentiate users from non-users of PCE substances.


Assuntos
Desempenho Acadêmico/psicologia , Esgotamento Profissional/psicologia , Cognição , Conhecimentos, Atitudes e Prática em Saúde , Nootrópicos/administração & dosagem , Automedicação/psicologia , Estudantes/psicologia , Tomada de Decisões , Suplementos Nutricionais , Feminino , Grécia , Humanos , Masculino , Autocontrole/psicologia , Comportamento Social , Universidades , Adulto Jovem
2.
IEEE Trans Radiat Plasma Med Sci ; 7(7): 704-711, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38524735

RESUMO

The HyPET project proposes a hybrid dedicated TOF-PET for prostate imaging, with pixelated detector blocks in the front layer and monolithic blocks in the back layer. In this work, four detector configurations have been experimentally evaluated for the rear detector layer. The detector configuration consists of LYSO monolithic blocks with the same size (25.4 mm × 25.4 mm) but different thicknesses (5, 7.5, 10, and 15 mm) coupled to the same SiPM array. Each detector configuration has been experimentally characterized in terms of time, energy and spatial resolution by scanning the crystal surface using a fan beam in steps of 0.25 mm. Regarding spatial resolution, the interaction position was estimated using a Neural Network technique. All resolutions except energy, which remains nearly constant at 17% for all cases, show better values for the 5 mm detector thickness. We have achieved spatial resolution values of FWHM of 1.02 ± 0.10, 1.19 ± 0.13, 1.53 ± 0.17, 2.33 ± 0.55 mm, for the 5, 7.5, 10, and 15 mm blocks, respectively. The detector time resolution obtained was 275 ± 26, 291 ± 21, 344 ± 48, and 433 ± 45 ps respectively, using the energy weighted average method for the time stamps.

3.
Med Phys ; 48(12): 8010-8023, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34723380

RESUMO

PURPOSE: Detectors for positron emission tomography (PET) typically use two types of scintillation crystals, pixelated or monolithic. A variant of these types of scintillators are the so-called semi-monolithic crystals. They consist of a monolithic crystal segmented in one direction in pieces called slabs. These scintillators have the potential to successfully combine the benefits of pixelated and monolithic configurations, providing good timing and spatial resolutions as well as the capacity to decode the depth of interaction (DOI) information. In this work, the timing performance of a detector based on semi-monolithic crystals was studied in depth. The energy response was also evaluated. METHODS: The semi-monolithic detector consists of 1 × 24 LYSO slabs of 25.4 × 12 × 0.95 mm3 each. The bottom surface of the slabs is coupled to an array of 8 × 8 silicon photomultipliers (SiPMs) of 3 × 3 mm2 active area, 50 µm cell size and 3.2 mm pitch. The 64 output signals were independently readout by the TOFPET2 ASIC. In order to achieve the best coincidence time resolution (CTR), four different time walk corrections were tested. Additional work investigated the best method of combining the timestamps belonging to the same event. RESULTS: The resolvability of the slabs in the measured flood maps improves with the thickness of a light guide placed in between the scintillators and photosensors. The energy resolution does not change significantly with values as good as 13.7%. Regarding the CTR, values of 335.8, 363, 369.8, and 402.5 ps have been obtained for the whole detector for no light guide, 0.5, 1.0, and 1.5 mm thickness light guide cases, respectively. These values further improve to 276.1, 302.6, 305.6 and 336.2 ps, respectively, when energy-weighted averaging of timestamps is applied. CONCLUSIONS: We have shown both an excellent timing resolution and good energy resolution for a PET detector based on semi-monolithic crystals. The use of light guides of different thicknesses does not significantly affect the energy resolution of the whole detector, but the timing capabilities slightly worsen with the increasing thickness of the light guide.


Assuntos
Tomografia por Emissão de Pósitrons , Contagem de Cintilação , Fenômenos Físicos
4.
Phys Med ; 70: 10-18, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31935602

RESUMO

Monolithic scintillators are more frequently used in PET instrumentation due to their advantages in terms of accurate position estimation of the impinging gamma rays both planar and depth of interaction, their increased efficiency, and expected timing capabilities. Such timing performance has been studied when those blocks are coupled to digital photosensors showing an excellent timing resolution. In this work we study the timing behaviour of detectors composed by monolithic crystals and analog SiPMs read out by an ASIC. The scintillation light spreads across the crystal towards the photosensors, resulting in a high number of SiPMs and ASIC channels fired. This has been studied in relation with the Coincidence Timing Resolution (CTR). We have used LYSO monolithic blocks with dimensions of 50 × 50 × 15 mm3 coupled to SiPM arrays (8 × 8 elements with 6 × 6 mm2 area) which compose detectors suitable for clinical applications. While a CTR as good as 186 ps FWHM was achieved for a pair of 3 × 3 × 5 mm3 LYSO crystals, when using the monolithic block and the SiPM arrays, a raw CTR over 1 ns was observed. An optimal timestamp assignment was studied as well as compensation methods for the time-skew and time-walk errors. This work describes all steps followed to improve the CTR. Eventually, an average detector time resolution of 497 ps FWHM was measured for the whole thick monolithic block. This improves to 380 ps FWHM for a central volume of interest near the photosensors. The timing dependency with the photon depth of interaction and planar position are also included.


Assuntos
Tomografia por Emissão de Pósitrons/instrumentação , Contagem de Cintilação/instrumentação , Calibragem , Desenho de Equipamento/instrumentação , Raios gama , Modelos Teóricos , Fótons , Sensibilidade e Especificidade , Fatores de Tempo
5.
EJNMMI Phys ; 7(1): 38, 2020 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-32504230

RESUMO

BACKGROUND: Prostate cancer (PCa) represents one of the most common types of cancers facing the male population. Nowadays, to confirm PCa, systematic or multiparametric MRI-targeted transrectal or transperineal biopsies of the prostate are required. However, due to the lack of an accurate imaging technique capable to precisely locate cancerous cells in the prostate, ultrasound biopsies sample random parts of the prostate and, therefore, it is possible to miss regions where those cancerous cells are present. In spite of the improvement with multiparametric MRI, the low reproducibility of its reading undermines the specificity of the method. Recent development of prostate-specific radiotracers has grown the interest on using positron emission tomography (PET) scanners for this purpose, but technological improvements are still required (current scanners have resolutions in the range of 4-5 mm). RESULTS: The main goal of this work is to improve state-of-the-art PCa imaging and diagnosis. We have focused our efforts on the design of a novel prostate-dedicated PET scanner, named ProsPET. This system has small scanner dimensions defined by a ring of just 41 cm inner diameter. In this work, we report the design, implementation, and evaluation (both through simulations and real data) of the ProsPET scanner. We have been able to achieve < 2 mm resolution in reconstructed images and high sensitivity. In addition, we have included a comparison with the Philips Gemini-TF scanner, which is used for routine imaging of PCa patients. The ProsPET exhibits better contrast, especially for rod sizes as small as 4.5 mm in diameter. Finally, we also show the first reconstructed image of a PCa patient acquired with the ProsPET. CONCLUSIONS: We have designed and built a prostate specific PET system, with a small footprint and improved spatial resolution when compared to conventional whole-body PET scanners. The gamma ray impact within each detector block includes accurate DOI determination, correcting for the parallax error. The potential role of combined organ-dedicated prostate-specific membrane antigen (PSMA) PET and ultrasound devices, as a prebiopsy diagnostic tool, could be used to guide sampling of the most aggressive sites in the prostate.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA