Resultados 1 - 8 de 8
Filtrar
1.
AJR Am J Roentgenol ; 217(2): 336-346, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32936016

RESUMO

BACKGROUND. Transthoracic echocardiography (TTE) is the standard of care for initial evaluation of patients with suspected cardioembolic stroke. Although TTE is useful for assessing certain sources of cardiac emboli, its diagnostic capability is limited in the detection of other sources, including left atrial thrombus and aortic plaques. OBJECTIVE. The purpose of this article was to investigate sensitivity, specificity, and predictive value of cardiac CTA (CCTA), cardiac MRI (CMRI), and TTE for recurrence in patients with suspected cardioembolic stroke. METHODS. We retrospectively included 151 patients with suspected cardioembolic stroke who underwent TTE and either CMRI (n = 75) or CCTA (n = 76) between January 2013 and May 2017. We evaluated for the presence of left atrial thrombus, left ventricular thrombus, vulnerable aortic plaque, cardiac tumors, and valvular vegetation as causes of cardioembolic stroke. The end point was stroke recurrence. Sensitivity, specificity, PPV, and NPV for recurrent stroke were calculated; the diagnostic accuracy of CMRI, CCTA, and TTE was compared between and within groups using AUC. RESULTS. Twelve and 14 recurrent strokes occurred in the CCTA and CMRI groups, respectively. Sensitivity, specificity, PPV, and NPV were 33.3%, 93.7%, 50.0%, and 88.2% for CCTA; 14.3%, 80.3%, 14.3%, and 80.3% for CMRI; 14.3%, 83.6%, 16.7%, and 80.9% for TTE in the CMRI group; and 8.3%, 93.7%, 20.0%, and 84.5% for TTE in the CCTA group. Accuracy was not different (p > .05) between CCTA (AUC = 0.63; 95% CI, 0.49-0.77), CMRI (0.53; 95% CI, 0.42-0.63), TTE in the CMRI group (0.51; 95% CI, 0.40-0.61), and TTE in the CCTA group (0.51; 95% CI, 0.42-0.59). In the CCTA group, atrial and ventricular thrombus were detected by CCTA in three patients and TTE in one patient; in the CMRI group, thrombus was detected by CMRI in one patient and TTE in two patients. CONCLUSION. CCTA, CMRI, and TTE showed comparably high specificity and NPV for cardioembolic stroke recurrence. CCTA and CMRI may be valid alternatives to TTE. CCTA may be preferred given potentially better detection of atrial and ventricular thrombus. CLINICAL IMPACT. CCTA and CMRI have similar clinical performance as TTE for predicting cardioembolic stroke recurrence. This observation may be especially important when TTE provides equivocal findings.


Assuntos
Ecocardiografia/métodos , AVC Embólico/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Estudos Retrospectivos , Sensibilidade e Especificidade
2.
Neuroradiology ; 61(3): 285-291, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30554271

RESUMO

PURPOSE: To investigate the variation in the quantification of the carotid degree of stenosis (DoS) with a dual energy computed tomography (CT), using different energy levels during the image reconstruction. METHODS: In this retrospective study, 53 subjects (37 males; mean age 67 ± 11 years; age range 47-83 years) studied with a multi-energy CT scanner were included. Datasets were reconstructed on a dedicated workstation and from the CT raw data multiple datasets were generated at the following monochromatic energy levels: 66, 70, 77, and 86 kilo-electronvolt (keV). Two radiologists independently performed all measurements for quantification of the degree of stenosis. Wilcoxon test was used to test the differences between the Hounsifield unit (HU) values in the plaques at different keV. RESULTS: The Wilcoxon analysis showed a statistically significant difference (p = 0.001) in the DoS assessment among the different keVs selected. The Bland-Altman analysis showed that the DoS difference had a linear relation with the keV difference (the bigger is the difference in keV, the bigger is the variation in DoS) and that for different keVs, the difference in DoS is reduced with its increase. CONCLUSION: A standardization in the use of the energy level during the image reconstruction should be considered.


Assuntos
Estenose das Carótidas/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
3.
J Clin Ultrasound ; 44(4): 210-20, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26887355

RESUMO

PURPOSE: To compare the strength of correlation between automatically measured carotid lumen diameter (LD) and interadventitial diameter (IAD) with plaque score (PS). METHODS: Retrospective study on a database of 404 common carotid artery B-mode sonographic images from 202 diabetic patients. LD and IAD were computed automatically using an advanced computerized edge detection method and compared with two distinct manual measurements. PS was computed by adding the maximal thickness in millimeters of plaques in segments taken from the internal carotid artery, bulb, and common carotid artery on both sides. RESULTS: The coefficient of correlation was 0.19 (p < 0.007) between LD and PS, and 0.25 (p < 0.0006) between IAD and PS. After excluding 10 outliers, coefficient of correlation was 0.25 (p < 0.0001) between LD and PS, and 0.38 (p < 0.0001) between IAD and PS. The precision of merit of automated versus the two manual measurements was 96.6% and 97.2% for LD, and 97.7% and 98.1%, for IAD, respectively. CONCLUSIONS: Our automated measurement system gave satisfying results in comparison with manual measurements. Carotid IAD was more strongly correlated to PS than carotid LD in this population sample of Japanese diabetic patients.


Assuntos
Doenças das Artérias Carótidas/diagnóstico , Artéria Carótida Primitiva/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico , Acidente Vascular Cerebral/etiologia , Ultrassonografia Doppler em Cores/métodos , Idoso , Doenças das Artérias Carótidas/complicações , Feminino , Seguimentos , Humanos , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/complicações , Curva ROC , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia
4.
J Med Syst ; 40(7): 182, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27299355

RESUMO

The degree of stenosis in the carotid artery can be predicted using automated carotid lumen diameter (LD) measured from B-mode ultrasound images. Systolic velocity-based methods for measurement of LD are subjective. With the advancement of high resolution imaging, image-based methods have started to emerge. However, they require robust image analysis for accurate LD measurement. This paper presents two different algorithms for automated segmentation of the lumen borders in carotid ultrasound images. Both algorithms are modeled as a two stage process. Stage one consists of a global-based model using scale-space framework for the extraction of the region of interest. This stage is common to both algorithms. Stage two is modeled using a local-based strategy that extracts the lumen interfaces. At this stage, the algorithm-1 is modeled as a region-based strategy using a classification framework, whereas the algorithm-2 is modeled as a boundary-based approach that uses the level set framework. Two sets of databases (DB), Japan DB (JDB) (202 patients, 404 images) and Hong Kong DB (HKDB) (50 patients, 300 images) were used in this study. Two trained neuroradiologists performed manual LD tracings. The mean automated LD measured was 6.35 ± 0.95 mm for JDB and 6.20 ± 1.35 mm for HKDB. The precision-of-merit was: 97.4 % and 98.0 % w.r.t to two manual tracings for JDB and 99.7 % and 97.9 % w.r.t to two manual tracings for HKDB. Statistical tests such as ANOVA, Chi-Squared, T-test, and Mann-Whitney test were conducted to show the stability and reliability of the automated techniques.


Assuntos
Algoritmos , Artérias Carótidas/diagnóstico por imagem , Estenose das Carótidas/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Ultrassonografia/métodos , Idoso , Estenose das Carótidas/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
5.
PLoS One ; 16(1): e0245134, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33411747

RESUMO

OBJECTIVES: To assess the feasibility of quantitative analysis of dynamic computed tomography angiography (dCTA) for the detection of endoleaks in patients who underwent endovascular repair of abdominal aortic aneurysms (EVAR). MATERIAL AND METHODS: Twenty patients scheduled for contrast-enhanced CT angiography (CTA) of the abdominal aorta post-EVAR were prospectively enrolled. All patients received a standard triphasic CTA protocol, followed by an additional dCTA. The dCTA acquisition enabled reconstruction of color-coded maps depicting blood perfusion and a dCTA dataset of the aneurysm sac. Observers assessed the dCTA and dynamic CT perfusion (dCTP) images for the detection of endoleaks, establishing diagnostic confidence based on a modified 5-point Likert scale. An index was calculated for the ratio between the endoleak and aneurysm sac using blood flow for dCTP and Hounsfield units (HU) for dCTA. The Wilcoxon test compared the endoleak index and the diagnostic confidence of the observers. RESULTS: In total, 19 patients (18 males, median age 74 years [70.5-75.7]) were included for analysis. Nine endoleaks were detected in 7 patients using triphasic CTA as the reference standard. There was complete agreement for endoleak detection between the two techniques on a per-patient basis. Both dCTA and dCTP identified an additional endoleak in one patient. The diagnostic confidence using dCTP for detection of endoleaks was not significantly superior to dCTA (5.0 [5-5] vs. 4.5 [4-5], respectively; p = 0.11); however, dCTP demonstrated superior diagnostic confidence for endoleak exclusion compared to dCTA (1.0 [1-1] vs 1.5 [1.5-1.5], respectively; p <0.01). Moreover, the dCTP endoleak index was significantly higher than the dCTA index (18.5 [10.8-20.5] vs. 3.5 [5-2.7], respectively; p = 0.02). CONCLUSIONS: Quantitative analysis of dCTP imaging can aid in the detection of endoleaks and demonstrates a higher endoleak detection rate than triphasic CTA, as well as a strong correlation with visual assessment of dCTA images.


Assuntos
Aorta Abdominal , Aneurisma da Aorta Abdominal , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Idoso , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Feminino , Humanos , Masculino
6.
Br J Radiol ; 92(1096): 20180548, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30730754

RESUMO

OBJECTIVE:: Some recent studies have explored how the experience in the observers change their performance in the endometriosis detection using MRI but the effects of the clinical information remains uncertain. The purpose of this study was to assess the effect of the clinical information in the diagnostic confidence in the MRI diagnosis of endometriosis. METHODS AND MATERIALS:: Institutional Review Board was obtained. This study is compliant to STARD method. 80 patients (mean age 32 years; range 19 - 46 years) who had undergone MRI study and surgery for suspected endometriosis were retrospectively evaluated. MRI exams were performed with a 1.5 T scanner and the following five locations were assessed: ovary, anterior compartment, vaginal fornix, utero-sacral ligaments, and Rectum\Sigmoid\Pouch of Douglas. Data sets were evaluated twice on a 5-point scale by four radiologists with different level of expertise; the first time blinded to the clinical information and the second time, after 3 months together with the clinical chart. Statistical analysis included receiver operating characteristics curve analysis, the Cohen weighted test and sensitivity, specificity, positive predictive value, negative predictive value, accuracy, LR+ and LR-. RESULTS:: A total of 140 localization of endometriosis (47 endometriomas and 93 endometriotic nodules) were found. The pairwise comparison demonstrated that in all cases the presence of clinical information improved the Az value. The concordance analysis indicated a mixed pattern from modest agreement (weighted κ value 0.556 for anterior compartment) to excellent agreement values (weighted κ value 0.867 for ovarian endometriomas). CONCLUSION:: The results of our study suggest that clinical information is useful in diagnosing endometriosis in general anterior compartment, but not in other locations. Less experienced radiologists (resident) may benefit from it at utero-sacral ligaments or Rectum\Sigmoid\Pouch of Douglas. ADVANCES IN KNOWLEDGE:: In this era of sometimes indiscriminate use of diagnostic methods, it is important to emphasis the context for interpretation of diagnostic results. Our paper confirms that clinical information is useful in diagnosing endometriosis.


Assuntos
Competência Clínica/estatística & dados numéricos , Endometriose/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Doenças Ovarianas/diagnóstico por imagem , Adulto , Escavação Retouterina/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Ovário/diagnóstico por imagem , Reto/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
7.
Eur J Radiol ; 112: 136-143, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30777202

RESUMO

BACKGROUND: The aim of this study was to assess the potential of rest-stress DECT iodine quantification to discriminate between normal, ischemic, and infarcted myocardium. METHODS: Patients who underwent rest-stress DECT on a 2nd generation dual-source system and cardiac magnetic resonance (CMR) were retrospectively included from a prospective study cohort. CMR was performed to identify ischemic and infarcted myocardium and categorize patients into ischemic, infarcted, and control groups. Controls were analyzed on a per-slice and per-segment basis. Regions of interest (ROIs) were placed in ischemic and infarcted areas based on CMR. Additionally, ROIs were placed in the septal area to assess normal and remote myocardium. RESULTS: We included 42 patients: 10 ischemic, 17 infarcted, and 15 controls. Iodine concentrations showed no significant between segments in controls. Iodine concentrations for normal myocardium increased significantly from rest to stress (median 3.7 mg/mL (interquartile range 3.5-3.9) vs. 4.5 mg/mL (4.3-4.9)) (p < 0.001). Iodine concentrations in diseased myocardium were significantly lower than in normal myocardium; 1.3 mg/mL (0.9-1.8) and 0.6 mg/mL (0.4-0.8) at rest and stress in ischemic myocardium, and 0.3 mg/mL (0.3-0.5) and 0.5 mg/mL (0.5-0.7) at rest and stress in infarcted myocardium (p < 0.005 and p < 0.001). At rest only, iodine concentrations were significantly lower in infarcted vs. ischemic myocardium (p < 0.001). The optimal threshold for differentiating diseased from normal myocardium was 2.5 mg/mL and 2.1 mg/mL for rest and stress (AUC 1.00). To discriminate ischemic from infarcted myocardium, the optimal threshold was 1.0 mg/ml (AUC 0.944) at rest. CONCLUSION: DECT iodine concentration from rest-stress imaging can potentially differentiate between normal, ischemic, and infarcted myocardium.


Assuntos
Meios de Contraste/farmacocinética , Iodo/farmacocinética , Isquemia Miocárdica/diagnóstico , Idoso , Estudos de Casos e Controles , Teste de Esforço/métodos , Feminino , Coração/fisiologia , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Imagem de Perfusão do Miocárdio/métodos , Miocárdio/química , Estudos Prospectivos , Descanso , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
8.
Med Biol Eng Comput ; 55(8): 1415-1434, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27943087

RESUMO

Monitoring of cerebrovascular diseases via carotid ultrasound has started to become a routine. The measurement of image-based lumen diameter (LD) or inter-adventitial diameter (IAD) is a promising approach for quantification of the degree of stenosis. The manual measurements of LD/IAD are not reliable, subjective and slow. The curvature associated with the vessels along with non-uniformity in the plaque growth poses further challenges. This study uses a novel and generalized approach for automated LD and IAD measurement based on a combination of spatial transformation and scale-space. In this iterative procedure, the scale-space is first used to get the lumen axis which is then used with spatial image transformation paradigm to get a transformed image. The scale-space is then reapplied to retrieve the lumen region and boundary in the transformed framework. Then, inverse transformation is applied to display the results in original image framework. Two hundred and two patients' left and right common carotid artery (404 carotid images) B-mode ultrasound images were retrospectively analyzed. The validation of our algorithm has done against the two manual expert tracings. The coefficient of correlation between the two manual tracings for LD was 0.98 (p < 0.0001) and 0.99 (p < 0.0001), respectively. The precision of merit between the manual expert tracings and the automated system was 97.7 and 98.7%, respectively. The experimental analysis demonstrated superior performance of the proposed method over conventional approaches. Several statistical tests demonstrated the stability and reliability of the automated system.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/diagnóstico por imagem , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Ultrassonografia/métodos , Idoso , Algoritmos , Artérias Carótidas/patologia , Doenças das Artérias Carótidas/patologia , Espessura Intima-Media Carotídea , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS