Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Adv Radiat Oncol ; 9(2): 101335, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38405318

RESUMO

Purpose: Our purpose was to assess physics quality assurance (QA) practices in less resourced radiation therapy (RT) centers to improve quality of care. Methods and Materials: A preliminary study was conducted in 2020 of 13 select RT centers in 6 countries, and in 2021, our team conducted onsite visits to all the RT centers in Ghana, one of the countries from the initial survey. The RT centers included 1 private and 2 public institutions (denoted as Public-1 and Public-2). Follow-up surveys were sent to 17 medical physicists from the site visit. Questions centered on the topics of equipment, institutional practice, physics quality assurance, management, and safety practices. Qualitative and descriptive methods were used for data analysis. Questions regarding operational challenges (machine downtime, patient-related issues, power outages, and staffing) were asked on a 5-point Likert scale. Results: The preliminary survey from 2020 had a 92% response rate. One key result showed that for RT centers in lower gross national income per capita countries there was a direct correlation between QA needs and the gross national income per capita of the country. The needs identified included film/array detectors, independent dose calculation software, calibration of ion chambers, diodes, thermoluminiscence diodes (TLDs), phantoms for verification, Treatment Planning System (TPS) test phantoms, imaging test phantoms and film dosimeters, education, and training. For the post survey after the site visit in 2021, we received a 100% response rate. The private and the Public-1 institutions each have computed tomography simulators located in their RT center. The average daily patient external beam workload for each clinic on a linear accelerator was: private = 25, Public-1 = 55, Public-2 = 40. The Co-60 workload was: Public-1 = 45, Public-2 = 25 (there was no Co-60 at the private hospital). Public-1 and -2 lacked the equipment necessary to conform to best practices in Task Group reports (TG) 142 and 198. Public-2 reported significant operational challenges. Notably, Public-1 and -2 have peer review chart rounds, which are attended by clinical oncologists, medical physicists, physicians, and physics trainees. All 17 physicists who responded to the post site visit survey indicated they had a system of documenting, tracking, and trending patient-related safety incidents, but only 1 physicist reported using International Atomic Energy Agency Safety in Radiation Oncology. Conclusions: The preliminary study showed a direct correlation between QA needs and the development index of a country, and the follow-up survey examines operational and physics QA practices in the RT clinics in Ghana, one of the initial countries surveyed. This will form the basis of a planned continent-wide survey in Africa intended to spotlight QA practices in low- and middle-income countries, the challenges faced, and lessons learned to help understand the gaps and needs to support local physics QA and management programs. Audits during the site visit show education and training remain the most important needs in operating successful QA programs.

2.
Heliyon ; 8(9): e10682, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36185136

RESUMO

In Intra-Operative Radiation Therapy (IORT) the tumour site is surgically exposed and normal tissue located around the tumour may be avoided. Electron applicators would require large surgical incisions; therefore, the preferred mechanism for beam collimation is the IORT cone system. FLASH radiotherapy (FLASH-RT) involves the treatment of tumours at ultra-high dose rates and the IORT cone system can also be used. This study validates the Monte Carlo-based calculations for these small electron beams to accurately determine the dose characteristics of each possible cone-energy combination as well as custom-built alloy cutouts attached to the end of the IORT cone. This will contribute to accurate dose distribution and output factor calculations that are essential to all radiation therapy treatments. A Monte Carlo (MC) model was modelled for electron beams produced by a Siemens Primus LINAC and the IORT cones. The accelerator was built with the component modules available in the BEAMnrc code. The phase-space file generated by the BEAM simulation was used as the source input for the subsequent DOSXYZnrc simulations. Percentage Depth Dose (PDD) data and profiles were extracted from the dose distributions obtained with the DOSXYZnrc simulations. These beam characteristics were compared with measured data for 6, 12, and 18 MeV electron beams for the IORT open cones of diameters 19, 45, and 64 mm and irregularly shaped cutouts. The MC simulations could replicate electron beams within a criterion of 3%/3 mm. Applicator factors were within 0.7%, and cone factors showed good agreement, except for the 9 mm cone size. Based on the successful comparisons between measurement and MC-calculated dose distributions, output factors for the open cones and for small irregularly shaped IORT beams, it may be concluded that the Monte Carlo based dose calculation could replicate electron beams used for IORT and FLASH-IORT.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA