Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Electrocardiol ; 83: 26-29, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38295539

RESUMO

BACKGROUND: Alcohol consumption is associated with a higher increased risk of atrial fibrillation (AF), but the acute effects on cardiac electrophysiology in humans remain poorly understood. The HOw ALcohol InDuces Atrial TachYarrhythmias (HOLIDAY) Trial revealed that alcohol shortened pulmonary vein atrial effective refractory periods, but more global electrophysiologic changes gleaned from the surface ECG have not yet been reported. METHODS: This was a secondary analysis of the HOLIDAY Trial. During AF ablation procedures, 100 adults were randomized to intravenous alcohol titrated to 0.08% blood alcohol concentration versus a volume and osmolarity-matched, masked, placebo. Intervals measured from 12­lead ECGs were compared between pre infusion and at infusion steady state (20 min). RESULTS: The average age was 60 years and 11% were female. No significant differences in the P-wave duration, PR, QRS or QT intervals, were present between alcohol and placebo arms. However, infusion of alcohol was associated with a statistically significant relative shortening of the JT interval (r: -14.73, p = 0.048) after multivariable adjustment. CONCLUSION: Acute exposure to alcohol was associated with a relative reduction in the JT interval, reflecting shortening of ventricular repolarization. These acute changes may reflect a more global shortening of refractoriness, suggesting immediate proarrhythmic effects pertinent to the atria and ventricles.


Assuntos
Fibrilação Atrial , Eletrocardiografia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Concentração Alcoólica no Sangue , Átrios do Coração , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37882609

RESUMO

AIMS: Transvenous lead extraction (TLE) is performed using non-laser and laser techniques with overall high efficacy and safety. Variation in outcomes between the two approaches does exist with limited comparative evidence in the literature. We sought to compare non-laser and laser TLE in a meta-analysis. METHODS AND RESULTS: We searched Medline, Embase, Scopus, ClinicalTrials.gov, and CENTRAL databases for TLE studies published between 1991 and 2021. From the included 68 studies, safety and efficacy data were carefully evaluated and extracted. Aggregated cases of outcomes were used to calculate odds ratio (OR), and pooled rates were synthesized from eligible studies to compare non-laser and laser techniques. Subgroup comparison of rotational tool and laser extraction was also performed. Non-laser in comparison with laser had lower procedural mortality (pooled rate 0% vs. 0.1%, P < 0.01), major complications (pooled rate 0.7% vs. 1.7%, P < 0.01), and superior vena cava (SVC) injury (pooled rate 0% vs. 0.5%, P < 0.001), with higher complete success (pooled rate 96.5% vs. 93.8%, P < 0.01). Non-laser comparatively to laser was more likely to achieve clinical [OR 2.16 (1.77-2.63), P < 0.01] and complete [OR 1.87 (1.69-2.08), P < 0.01] success, with a lower procedural mortality risk [OR 1.6 (1.02-2.5), P < 0.05]. In the subgroup analysis, rotational tool compared with laser achieved greater complete success (pooled rate 97.4% vs. 95%, P < 0.01) with lower SVC injury (pooled rate 0% vs. 0.7%, P < 0.01). CONCLUSION: Non-laser TLE is associated with a better safety and efficacy profile when compared with laser methods. There is a greater risk of SVC injury associated with laser sheath extraction.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/efeitos adversos , Veia Cava Superior/cirurgia , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Lasers , Cateterismo Cardíaco , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos
3.
J Cardiovasc Electrophysiol ; 33(9): 1987-1991, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35726747

RESUMO

INTRODUCTION: Atrial fibrillation (AF) ablation is performed worldwide. To attract patients, hospitals frequently have webpages that tout the success of the procedure. The information disseminated to the public via these webpages has not been systematically reviewed. Our objective was to assess accuracy of information delivered to the public on hospital websites in regard to atrial AF ablation. METHODS: From July 2019 to January 2020, we performed a Google search for all US hospitals registered with Medicare to see if they had a webpage describing AF ablation. Resulting hospital webpages were abstracted for data on AF ablation success rates and risks. Success rates over 86%, the highest success rate in the medical literature, were deemed exaggerated. RESULTS: Among 4805 hospitals, 487 had webpages describing AF ablation and 33 discussed success rates of AF ablation. Twelve percentage reported exaggerated success rates, 3% referred to ablation as a cure, and 2.8% referred to ablation as a tool to eliminate AF. Less than 10% of webpages describing AF ablation noted the potential need for a second ablation to achieve the stated success rate and merely 16% mentioned risks of the procedure. One percentage of webpages directly suggested AF ablation could reduce risk of stroke while others indirectly suggested it by discussing cessation of anticoagulation. Two webpages mentioned reduced mortality. CONCLUSION: US hospital webpages rarely discuss AF ablation. When discussed, there were concerning unsubstantiated claims regarding mortality, stroke prevention, and need for medical therapy. This could lead to some patients undergoing AF ablation based on faulty understanding.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Comunicação , Hospitais , Humanos , Medicare , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento , Estados Unidos
4.
Ann Intern Med ; 174(11): 1503-1509, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34461028

RESUMO

BACKGROUND: Patients' self-reports suggest that acute alcohol consumption may trigger a discrete atrial fibrillation (AF) event. OBJECTIVE: To objectively ascertain whether alcohol consumption heightens risk for an AF episode. DESIGN: A prospective, case-crossover analysis. SETTING: Ambulatory persons in their natural environments. PARTICIPANTS: Consenting patients with paroxysmal AF. MEASUREMENTS: Participants were fitted with a continuous electrocardiogram (ECG) monitor and an ankle-worn transdermal ethanol sensor for 4 weeks. Real-time documentation of each alcoholic drink consumed was self-recorded using a button on the ECG recording device. Fingerstick blood tests for phosphatidylethanol (PEth) were used to corroborate ascertainments of drinking events. RESULTS: Of 100 participants (mean age, 64 years [SD, 15]; 79% male; 85% White), 56 had at least 1 episode of AF. Results of PEth testing correlated with the number of real-time recorded drinks and with events detected by the transdermal alcohol sensor. An AF episode was associated with 2-fold higher odds of 1 alcoholic drink (odds ratio [OR], 2.02 [95% CI, 1.38 to 3.17]) and greater than 3-fold higher odds of at least 2 drinks (OR, 3.58 [CI, 1.63 to 7.89]) in the preceding 4 hours. Episodes of AF were also associated with higher odds of peak blood alcohol concentration (OR, 1.38 [CI, 1.04 to 1.83] per 0.1% increase in blood alcohol concentration) and the total area under the curve of alcohol exposure (OR, 1.14 [CI, 1.06 to 1.22] per 4.7% increase in alcohol exposure) inferred from the transdermal ethanol sensor in the preceding 12 hours. LIMITATION: Confounding by other time-varying exposures that may accompany alcohol consumption cannot be excluded, and the findings from the current study of patients with AF consuming alcohol may not apply to the general population. CONCLUSION: Individual AF episodes were associated with higher odds of recent alcohol consumption, providing objective evidence that a modifiable behavior may influence the probability that a discrete AF event will occur. PRIMARY FUNDING SOURCE: National Institute on Alcohol Abuse and Alcoholism.


Assuntos
Consumo de Bebidas Alcoólicas/efeitos adversos , Fibrilação Atrial/etiologia , Concentração Alcoólica no Sangue , Estudos Cross-Over , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
5.
N Engl J Med ; 379(13): 1205-1215, 2018 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-30280654

RESUMO

BACKGROUND: Despite the high rate of sudden death after myocardial infarction among patients with a low ejection fraction, implantable cardioverter-defibrillators are contraindicated until 40 to 90 days after myocardial infarction. Whether a wearable cardioverter-defibrillator would reduce the incidence of sudden death during this high-risk period is unclear. METHODS: We randomly assigned (in a 2:1 ratio) patients with acute myocardial infarction and an ejection fraction of 35% or less to receive a wearable cardioverter-defibrillator plus guideline-directed therapy (the device group) or to receive only guideline-directed therapy (the control group). The primary outcome was the composite of sudden death or death from ventricular tachyarrhythmia at 90 days (arrhythmic death). Secondary outcomes included death from any cause and nonarrhythmic death. RESULTS: Of 2302 participants, 1524 were randomly assigned to the device group and 778 to the control group. Participants in the device group wore the device for a median of 18.0 hours per day (interquartile range, 3.8 to 22.7). Arrhythmic death occurred in 1.6% of the participants in the device group and in 2.4% of those in the control group (relative risk, 0.67; 95% confidence interval [CI], 0.37 to 1.21; P=0.18). Death from any cause occurred in 3.1% of the participants in the device group and in 4.9% of those in the control group (relative risk, 0.64; 95% CI, 0.43 to 0.98; uncorrected P=0.04), and nonarrhythmic death in 1.4% and 2.2%, respectively (relative risk, 0.63; 95% CI, 0.33 to 1.19; uncorrected P=0.15). Of the 48 participants in the device group who died, 12 were wearing the device at the time of death. A total of 20 participants in the device group (1.3%) received an appropriate shock, and 9 (0.6%) received an inappropriate shock. CONCLUSIONS: Among patients with a recent myocardial infarction and an ejection fraction of 35% or less, the wearable cardioverter-defibrillator did not lead to a significantly lower rate of the primary outcome of arrhythmic death than control. (Funded by the National Institutes of Health and Zoll Medical; VEST ClinicalTrials.gov number, NCT01446965 .).


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Infarto do Miocárdio/terapia , Taquicardia Ventricular/prevenção & controle , Dispositivos Eletrônicos Vestíveis , Idoso , Morte Súbita Cardíaca/etiologia , Desfibriladores/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/mortalidade , Volume Sistólico , Taquicardia Ventricular/mortalidade , Resultado do Tratamento , Dispositivos Eletrônicos Vestíveis/efeitos adversos
7.
J Cardiovasc Electrophysiol ; 31(12): 3232-3242, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33107135

RESUMO

INTRODUCTION: Permanent junctional reciprocating tachycardia (PJRT) is a rare supraventricular tachycardia (SVT), typically involving a single decremental posteroseptal accessory pathway (AP). METHODS: Four patients with long RP SVT underwent electrophysiology (EP) study and ablation. The cases were reviewed. RESULTS: Case 1 recurred despite 3 prior ablations at the site of earliest retrograde atrial activation during orthodromic reciprocating tachycardia (ORT). Mapping during a repeat EP study demonstrated a prepotential in the coronary sinus (CS). Ablation over the earliest atrial activation in the CS resulted in dissociation of the potential from the atrium during sinus rhythm. The potential was traced back to the CS os and ablated. Case 2 underwent successful ablation at 6 o'clock on the mitral annulus (MA). ORT recurred and successful ablation was performed at 1 o'clock on the MA. Case 3 had tachycardia with variation in both V-A and A-H intervals which precluded the use of usual maneuvers so we used simultaneous atrial and ventricular pacing and introduced a premature atrial contraction with a closely coupled premature ventricular contraction. Case 4 had had two prior atrial fibrillation ablations with continued SVT over a decremental atrioventricular bypass tract that was successfully ablated at 5 o'clock on the tricuspid annulus. A second SVT consistent with a concealed nodoventricular pathway was successfully ablated at the right inferior extension of the AV nodal slow pathway. CONCLUSION: We describe challenging cases of PJRT by virtue of complex anatomy, diagnostic features, and multiple arrhythmia mechanisms.


Assuntos
Ablação por Cateter , Taquicardia Reciprocante , Taquicardia Supraventricular , Nó Atrioventricular , Eletrocardiografia , Humanos , Taquicardia Reciprocante/diagnóstico , Taquicardia Reciprocante/cirurgia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia
8.
J Cardiovasc Electrophysiol ; 31(5): 1009-1018, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32083365

RESUMO

BACKGROUND: Vest Prevention of Early Sudden Death Trial did not demonstrate a significant reduction in arrhythmic death with the wearable cardioverter-defibrillator (WCD), but compliance with the device may have substantially affected the results. ThePletcher influence of WCD compliance on outcomes has not yet been fully evaluated. METHODS: Using linear and pooled logistic models, we performed as-treated analyses omitting person-time in the hospital and adjusted for correlates of WCD compliance. To assess the impact of early stopping of WCD, we performed a per-protocol Kaplan-Meier analysis, censoring after the last day the WCD was worn. Interactions of potential effect modifiers with treatment assignment and WCD compliance on outcomes were investigated. Finally, we used linear models to identify predictors of WCD compliance. RESULTS: A per-protocol analysis demonstrated a significant reduction in total (P < .001) and arrhythmic (P = .001) mortality. Better WCD compliance was independently predicted by cardiac arrest during index myocardial infarction (MI), higher Cr, diabetes, prior heart failure, EF ≤ 25%, Polish enrolling center and number of WCD alarms, while worse compliance was predicted by being divorced, Asian race, higher body mass index, prior percutaneous coronary intervention, or any WCD shock. Neither excluding time in hospital from the as-treated analysis nor adjustment for factors affecting WCD compliance materially changed the results. No variable demonstrated a significant interaction in either the intention-to-treat or as-treated analysis. CONCLUSION: Robust sensitivity analyses of as-treated and per-protocol analyses suggest that the WCD is protective in compliant patients with ejection fraction less than or equal to 35% during the first 3 months post-MI.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Cardioversão Elétrica/instrumentação , Infarto do Miocárdio/terapia , Cooperação do Paciente , Dispositivos Eletrônicos Vestíveis , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Morte Súbita Cardíaca/etiologia , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/mortalidade , Fatores de Proteção , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
9.
Europace ; 21(11): 1703-1709, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31545350

RESUMO

AIMS: Rotating sheaths and laser sheaths are commonly used for transvenous lead extraction. This study aims to compare observed mortality between both approaches. METHODS AND RESULTS: The Manufacturer and User Facility Device Experience database was searched from 2011 to 2016 to determine number of deaths associated with each sheath. An independent analytics firm provided estimates for number of cases done, allowing calculation of market share. A sensitivity analysis was performed to determine relative risk (RR) of mortality at the calculated market share (36% rotating/64% laser) and two others. Additional sensitivity analyses assumed underreporting of deaths associated with rotating sheaths. An estimated 50 545 extractions were performed. Thirteen deaths were associated with rotating sheaths compared to 167 with laser sheaths. Of these, 92% (rotating) and 95% (laser) were due to cardiovascular injury. At the calculated market share, the RR of death was 7.2 times greater with laser sheaths [95% confidence interval (CI) 4.1-12.7, P < 0.0001]. At market share estimates of 25% rotating/75% laser and 45% rotating/55% laser, the RR of death with laser sheaths was 4.3 (95% CI 2.4-7.5, P < 0.0001) and 10.5 times greater (95% CI 6.0-18.5, P < 0.0001), respectively. The RR of death remained significant when assuming deaths with rotating sheaths were underreported and when deaths using both sheaths were attributed to the rotating sheath. CONCLUSIONS: Lead extraction with laser sheaths appears to be associated with a higher risk of mortality compared to rotating sheaths. Further studies are warranted to confirm this finding.


Assuntos
Arritmias Cardíacas/terapia , Remoção de Dispositivo/mortalidade , Eletrodos Implantados , Arritmias Cardíacas/mortalidade , Remoção de Dispositivo/métodos , Desenho de Equipamento , Seguimentos , Humanos , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia
10.
Circulation ; 135(9): 867-877, 2017 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-28119381

RESUMO

BACKGROUND: Catheter ablation for ventricular tachycardia and premature ventricular complexes (PVCs) is common. Catheter ablation of atrial fibrillation is associated with a risk of cerebral emboli attributed to cardioversions and numerous ablation lesions in the low-flow left atrium, but cerebral embolic risk in ventricular ablation has not been evaluated. METHODS: We enrolled 18 consecutive patients meeting study criteria scheduled for ventricular tachycardia or PVC ablation over a 9-month period. Patients undergoing left ventricular (LV) ablation were compared with a control group of those undergoing right ventricular ablation only. Patients were excluded if they had implantable cardioverter defibrillators or permanent pacemakers. Radiofrequency energy was used for ablation in all cases and heparin was administered with goal-activated clotting times of 300 to 400 seconds for all LV procedures. Pre- and postprocedural brain MRI was performed on each patient within a week of the ablation procedure. Embolic infarcts were defined as new foci of reduced diffusion and high signal intensity on fluid-attenuated inversion recovery brain MRI within a vascular distribution. RESULTS: The mean age was 58 years, half of the patients were men, half had a history of hypertension, and the majority had no known vascular disease or heart failure. LV ablation was performed in 12 patients (ventricular tachycardia, n=2; PVC, n=10) and right ventricular ablation was performed exclusively in 6 patients (ventricular tachycardia, n=1; PVC, n=5). Seven patients (58%) undergoing LV ablation experienced a total of 16 cerebral emboli, in comparison with zero patients undergoing right ventricular ablation (P=0.04). Seven of 11 patients (63%) undergoing a retrograde approach to the LV developed at least 1 new brain lesion. CONCLUSIONS: More than half of patients undergoing routine LV ablation procedures (predominately PVC ablations) experienced new brain emboli after the procedure. Future research is critical to understanding the long-term consequences of these lesions and to determining optimal strategies to avoid them.


Assuntos
Ablação por Cateter/efeitos adversos , Embolia Intracraniana/etiologia , Complexos Ventriculares Prematuros/cirurgia , Idoso , Aorta/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Ecocardiografia , Feminino , Ventrículos do Coração/cirurgia , Humanos , Embolia Intracraniana/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/cirurgia
12.
J Cardiovasc Electrophysiol ; 28(7): 754-761, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28429499

RESUMO

BACKGROUND: The cornerstone of atrial fibrillation (AF) ablation is isolation of the pulmonary veins (PVs). Patients with recurrent AF undergoing repeat ablation usually have PV reconnection (PVr). The ablation strategy and outcome of patients undergoing repeat ablation who have persistent isolation of all PVs (PVi) at the time of repeat ablation is unknown. METHODS AND RESULTS: We studied consecutive patients with recurrent AF undergoing repeat ablation and compared patients with PVi to those with PVr. One hundred fifty-two patients underwent repeat ablation, and of these, 25 patients (16.4%) had PVi. Patients with PVi underwent ablation targeting any isoproterenol induced AF triggers, atrial substrate, or inducible atrial tachycardias or flutters. Patients with PVi compared to PVr were more likely to have a history of persistent AF (64% vs. 26%; P < 0.0001), obesity (BMI 30.4 vs. 28.2; P = 0.05), and prior use of contact force sensing catheters (28% vs. 0.8%, P < 0.0001). After a mean follow-up of 19 ± 15 months, 56% of PVi patients remained in sinus rhythm compared to 76.3% of PVr patients (P = 0.036). In a multivariable model, PVi patients and those with cardiomyopathy had a higher risk of recurrent atrial tachyarrhythmias (HR = 3.6 95%, CI 1.6-8.3, P = 0.002 and HR = 6.2, 95% CI 2.3-16.3, P < 0.0001, respectively). CONCLUSION: In patients who have all PVs isolated at the time of the redo AF ablation, a strategy of targeting non-PV AF triggers and inducible flutters can still lead to AF freedom in more than half of patients. Patients with PVr, however, have a better long-term outcome.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos , Frequência Cardíaca/fisiologia , Veias Pulmonares/cirurgia , Idoso , Cateterismo Cardíaco/tendências , Eletrocardiografia/métodos , Eletrocardiografia/tendências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiologia , Estudos Retrospectivos
13.
Circ J ; 81(11): 1739-1741, 2017 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-28904267

RESUMO

BACKGROUND: Cardiac sarcoidosis (CS) is a life-threatening disease that is frequently under-diagnosed.Methods and Results:We used a nationwide inpatient sample to identify CS patients from 2005 to 2011 in the USA. The annual admissions of CS increased from 1,108 in 2005 to 2,182 in 2011, representing a 2-fold rise over a short time. The proportions of CS patients with severe comorbidities, ventricular tachycardia, ventricular fibrillation and heart failure all increased from 2005 to 2011. However, the in-hospital mortality rate declined. CONCLUSIONS: An increasing trend of CS was observed. Cardiologists should notice that CS is not as rare as thought.


Assuntos
Cardiomiopatias/epidemiologia , Hospitalização/tendências , Sarcoidose/epidemiologia , Adulto , Comorbidade/tendências , Feminino , Insuficiência Cardíaca , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Sarcoidose/mortalidade , Taquicardia Ventricular , Estados Unidos , Fibrilação Ventricular
14.
Pacing Clin Electrophysiol ; 39(12): 1366-1372, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27753113

RESUMO

BACKGROUND: Atrial refractoriness may be an important determinant of atrial fibrillation (AF) risk, but its measurement is not clinically accessible. Because the QT interval predicts incident AF and the atrium and ventricle share repolarizing ion currents, we investigated the association between an individual's QT interval and atrial effective refractory period (AERP). METHODS: In paroxysmal AF patients presenting for catheter ablation, the QT interval was measured from the surface 12-lead electrocardiogram. The AERP was defined as the longest S1-S2 coupling interval without atrial capture using a 600-ms drive cycle length. RESULTS: In 28 patients, there was a positive correlation between QTc and mean AERP. After multivariate adjustment, a 1-ms increase in QTc predicted a 0.70-ms increase in AERP. CONCLUSIONS: The QTc interval reflects the AERP, suggesting that the QTc interval may be used as a marker of atrial refractoriness relevant to assessing AF risk and mechanism-specific therapeutic strategies.


Assuntos
Fibrilação Atrial/diagnóstico , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Síndrome do QT Longo/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade
16.
Pacing Clin Electrophysiol ; 38(10): 1173-80, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26137999

RESUMO

INTRODUCTION: There are several methods to induce ventricular fibrillation (VF) during defibrillation threshold (DFT) testing. Delivering a shock at a critical time during the T wave (T-shock) is the conventional approach, while delivering a constant direct current voltage (DC stim) from the implantable cardioverter defibrillator is an alternative method. Only a few reports compare VF induction methods. The purpose of this study was to evaluate the effects and safety of DC stim versus T-shock. METHODS: We retrospectively investigated 414 consecutive patients undergoing DFT testing. We compared the two groups (DC stim and T-shock) with respect to clinical characteristics, electrocardiogram (ECG) changes, and complications. RESULTS: Ventricular arrhythmia, including ventricular tachycardia (VT) and VF, was induced by DC stim in 93 patients or T-shock in 321 patients. No more than three attempts were performed during one procedure. There was no significant difference in the baseline ECG, induced tachycardia cycle length (TCL), or complications between the two groups. However, the induced TCL was significantly shorter than the clinical TCL regardless of induction method (P = 0.001). Five patients suffered major complications (i.e., electromechanical dissociation or incessant VT). A history of atrial fibrillation was significantly greater in patients with major complications than the others (80% vs 24%, P = 0.004), and was an independent predictor on multivariate analysis. CONCLUSIONS: There is no significant difference in induced TCL or complications between the DC stim and T-shock. The induced TCL is significantly shorter than clinical TCL regardless of induction method.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Estimulação Elétrica/métodos , Técnicas Eletrofisiológicas Cardíacas/estatística & dados numéricos , Disfunção Ventricular Esquerda/epidemiologia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/prevenção & controle , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Limiar Diferencial , Estimulação Elétrica/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , São Francisco/epidemiologia , Distribuição por Sexo , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia , Fibrilação Ventricular/epidemiologia
18.
J Cardiovasc Electrophysiol ; 25(7): 756-62, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24612052

RESUMO

INTRODUCTION: Patients with frequent premature ventricular complexes (PVCs) might be at risk for the developing or exacerbation of left ventricular (LV) dysfunction. However, some patients with a high-PVC burden do not develop cardiomyopathy, while other patients with low-PVC burden can develop cardiomyopathy. The purpose of this study was to evaluate the positive predictors of idiopathic PVCs-induced cardiomyopathy. METHODS AND RESULTS: We investigated 214 patients undergoing successful ablation of PVCs who had no other causes of cardiomyopathy. We divided the study cohort into 2 groups: ejection fraction (EF) ≥ 50% (normal LV) and EF < 50% (LV dysfunction). We analyzed the clinical characteristics, including the electrocardiogram and findings at electrophysiology study. Among these patients, 51 (24%) had reduced LVEF and 163 (76%) had normal LV function. Patients with LV dysfunction had significantly longer coupling interval (CI) dispersion (maximum-CI-minimum-CI) and had significantly higher PVC burden compared to those with normal LV function (CI-dispersion: 115 ± 25 milliseconds vs. 94 ± 19 milliseconds; P < 0.001; PVC burden: 19% vs. 15%; P = 0.04). Furthermore, patients with LV dysfunction had significantly higher body mass index (BMI) compared to those with normal LV function (BMI > 30 kg/m(2) ; 37% vs. 13%; P = 0.001). Logistic regression analysis showed that CI-dispersion, PVC burden, and BMI (>30 kg/m(2) ) are independent predictors of PVC-induced cardiomyopathy. CONCLUSIONS: In addition to the PVC burden, the CI-dispersion and BMI are associated with PVC-induced cardiomyopathy.


Assuntos
Índice de Massa Corporal , Cardiomiopatias/etiologia , Sistema de Condução Cardíaco/fisiopatologia , Disfunção Ventricular Esquerda/etiologia , Complexos Ventriculares Prematuros/complicações , Potenciais de Ação , Adulto , Idoso , Cardiomiopatias/diagnóstico , Cardiomiopatias/fisiopatologia , Ablação por Cateter , Distribuição de Qui-Quadrado , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia
19.
Pacing Clin Electrophysiol ; 36(10): 1294-300, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23844971

RESUMO

BACKGROUND: Clot formation on cardiac device leads is poorly understood. We sought to determine how often clot is seen on device leads by transthoracic echo (TTE), identify risk factors, and to describe the natural history of this phenomenon. METHODS: We reviewed 71,888 echocardiographic studies performed at the University of California, San Francisco from 2005 to 2011. We searched for cases where clot was found adhered to a device lead with no diagnosis of endocarditis. For every case, three age-matched controls with a device but no clot were selected from the echo database. RESULTS: We found 15 cases with clot adhered to a device lead among 1,086 patients with devices who had TTE (1.4%). In univariate analysis, females had more than four times greater odds of having a clot on their device lead and patients with a history of atrial fibrillation (AF) had an eight times greater odds. Percentage mode switch was also associated with clot formation. Only AF was still associated with clot formation after multivariate analysis. Follow-up data were available for nine of 15 patients. All nine patients had intensification of their anticoagulant/antiplatelet regimen following clot discovery. Complete resolution or shrinkage of clot was observed in eight of nine patients. The one case with no change was a patient who continued taking only aspirin (higher dose) after clot discovery. None of the nine patients had embolic phenomenon. CONCLUSION: Patients with AF are at higher risk for clot formation on device leads. After clot detection, treatment with anticoagulants usually results in resolution of the clot without embolic phenomenon.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Desfibriladores Implantáveis/estatística & dados numéricos , Eletrodos Implantados/estatística & dados numéricos , Cardiopatias/epidemiologia , Trombose/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico , Medição de Risco , Fatores de Risco , São Francisco/epidemiologia
20.
J Interv Card Electrophysiol ; 66(5): 1067-1075, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34839431

RESUMO

BACKGROUND: Rotating and laser sheaths are both routinely used in transvenous lead extraction (TLE) which can lead to catastrophic complications including death. The efficacy and risk of each approach are uncertain. To perform a meta-analysis to compare success and mortality rates associated with rotating and laser sheaths. METHODS: We searched electronic academic databases for case series of consecutive patients and randomized controlled trials published 1998-2017 describing the use of rotating and laser sheaths for TLE. Among 48 studies identified, rotating sheaths included 1,094 patients with 1,955 leads in 14 studies, and laser sheaths included 7,775 patients with 12,339 leads in 34 studies. Patients receiving rotating sheaths were older (63 versus 60 years old) and were more often male (74% versus 72%); CRT-P/Ds were more commonly extracted using rotating sheaths (12% versus 7%), whereas ICDs were less common (37% versus 42%), p > 0.05 for all. Infection as an indication for lead extraction was higher in the rotating sheath group (59.8% versus 52.9%, p = 0.002). The mean time from initial lead implantation was 7.2 years for rotating sheaths and 6.3 years for laser sheaths (p > 0.05). RESULTS: Success rates for complete removal of transvenous leads were 95.1% in rotating sheaths and 93.4% in laser sheaths (p < 0.05). There was one death among 1,094 patients (0.09%) in rotating sheaths and 66 deaths among 7,775 patients (0.85%) in laser sheaths, translating to a 9.3-fold higher risk of death with laser sheaths (95% CI 1.3 to 66.9, p = 0.01). CONCLUSIONS: Laser sheaths were associated with lower complete lead removal rate and a 9.3-fold higher risk of death.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Masculino , Pessoa de Meia-Idade , Remoção de Dispositivo , Lasers , Estudos Retrospectivos , Falha de Equipamento , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA