1.
Analyst ; 138(9): 2558-66, 2013 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-23478433

RESUMO

A fully automated point-of-care testing (POCT) system with a surface acoustic wave (SAW) immunosensor was developed for rapid and sensitive detection of cardiac troponin I (cTnI) in body fluid (plasma and whole blood). The assay, based on gold nanoparticle sandwich immunoassay and subsequent gold staining, was performed on the SAW immunosensor packaged inside a disposable microfluidic cartridge. The entire fluidic process, including plasma separation, reagent transport, metering, and mixing, was carried out by controlling the centrifugal force acting on the rotating cartridge and laser-irradiated ferrowax microvalves. On investigation of sensor response to various cTnI concentrations, the system exhibited a high performance with a detection limit of 6.7 pg mL(-1), and the coefficient of variation was less than 10% over the entire test range (10 pg mL(-1) to 25 ng mL(-1)). On comparing this POCT system with a clinically utilized system in a physical laboratory (Centaur® XP; Siemens), a correlation coefficient of 0.998 was found, validating the diagnostic capability of the SAW immunosensor.


Assuntos
Imunoensaio/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Troponina I/sangue , Desenho de Equipamento , Ouro/química , Humanos , Limite de Detecção , Nanopartículas/química , Som
2.
Anal Chem ; 83(22): 8629-35, 2011 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-21992491

RESUMO

We present a rapid and sensitive surface acoustic wave (SAW) immunosensor that utilizes gold staining as a signal enhancement method. A sandwich immunoassay was performed on sensing area of the SAW sensor, which could specifically capture and detect cardiac markers (cardiac troponin I (cTnI), creatine kinase (CK)-MB, and myoglobin). The analytes in human serum were captured on gold nanoparticles (AuNPs) that were conjugated in advance with detection antibodies. Introduction of these complexes to the capture antibody-immobilized sensor surface resulted in a classic AuNP-based sandwich immunoassay format that has been used for signal amplification. In order to achieve further signal enhancement, a gold staining method was performed, which demonstrated that it is possible to obtain gold staining-mediated signal augmentation on a mass-sensitive device. The sensor response due to gold staining varied as a function of cardiac marker concentration. We also investigated effects of increasing operating frequency on sensor responses. Results showed that detection limit of the SAW sensor could be further improved by increasing the operating frequency.


Assuntos
Técnicas Biossensoriais/métodos , Creatina Quinase/sangue , Coração , Mioglobina/sangue , Troponina I/sangue , Anticorpos/análise , Biomarcadores/sangue , Técnicas Biossensoriais/instrumentação , Creatina Quinase/metabolismo , Ouro/química , Humanos , Imunoensaio/instrumentação , Nanopartículas Metálicas/química , Sensibilidade e Especificidade , Propriedades de Superfície
3.
Sci Rep ; 11(1): 1238, 2021 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-33441675

RESUMO

Bioelectrical impedance analysis (BIA) is used to analyze human body composition by applying a small alternating current through the body and measuring the impedance. The smaller the electrode of a BIA device, the larger the impedance measurement error due to the contact resistance between the electrode and human skin. Therefore, most commercial BIA devices utilize electrodes that are large enough (i.e., 4 × 1400 mm2) to counteract the contact resistance effect. We propose a novel method of compensating for contact resistance by performing 4-point and 2-point measurements alternately such that body impedance can be accurately estimated even with considerably smaller electrodes (outer electrodes: 68 mm2; inner electrodes: 128 mm2). Additionally, we report the use of a wrist-wearable BIA device with single-finger contact measurement and clinical test results from 203 participants at Seoul St. Mary's Hospital. The correlation coefficient and standard error of estimate of percentage body fat were 0.899 and 3.76%, respectively, in comparison with dual-energy X-ray absorptiometry. This result exceeds the performance level of the commercial upper-body portable body fat analyzer (Omron HBF-306). With a measurement time of 7 s, this sensor technology is expected to provide a new possibility of a wearable bioelectrical impedance analyzer, toward obesity management.


Assuntos
Impedância Elétrica , Manejo da Obesidade , Obesidade , Dispositivos Eletrônicos Vestíveis , Adolescente , Adulto , Idoso , Eletrodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/patologia , Obesidade/fisiopatologia
4.
ACS Nano ; 15(9): 14207-14217, 2021 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-34170113

RESUMO

Continuous monitoring of hydrogen sulfide (H2S) in human breath for early stage diagnosis of halitosis is of great significance for prevention of dental diseases. However, fabrication of a highly selective and sensitive H2S gas sensor material still remains a challenge, and direct analysis of real breath samples has not been properly attempted, to the best of our knowledge. To address the issue, herein, we introduce facile cofunctionalization of WO3 nanofibers with alkaline metal (Na) and noble metal (Pt) catalysts via the simple addition of sodium chloride (NaCl) and Pt nanoparticles (NPs), followed by electrospinning process. The Na-doping and Pt NPs decoration in WO3 grains induces the partial evolution of the Na2W4O13 phase, causing the buildup of Pt/Na2W4O13/WO3 multi-interface heterojunctions that selectively interacts with sulfur-containing species. As a result, we achieved the highest-ranked sensing performances, that is, response (Rair/Rgas) = 780 @ 1 ppm and selectivity (RH2S/REtOH) = 277 against 1 ppm ethanol, among the chemiresistor-based H2S sensors, owing to the synergistic chemical and electronic sensitization effects of the Pt NP/Na compound cocatalysts. The as-prepared sensing layer was proven to be practically effective for direct, and quantitative halitosis analysis based on the correlation (accuracy = 86.3%) between the H2S concentration measured using the direct breath signals obtained by our test device (80 cases) and gas chromatography. This study offers possibilities for direct, highly reliable and rapid detection of H2S in real human breath without the need of any collection or filtering equipment.


Assuntos
Halitose , Eletrônica , Halitose/diagnóstico , Humanos , Óxidos