Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 148(1): 35-46, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37199171

RESUMO

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Flutter Atrial/etiologia , Sistema de Registros , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
2.
J Cardiovasc Electrophysiol ; 34(1): 90-98, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36217994

RESUMO

INTRODUCTION: Phrenic nerve (PN) injury is a rare but severe complication of radiofrequency (RF) pulmonary vein isolation (PVI). The objective of this study was to characterize the typical intracardiac course of the PN with a three-dimensional electroanatomic mapping system, to quantify the need for modification of the ablation trajectory to avoid delivering an ablation lesion on sites with PN capture, and to identify very circumscribed areas of common PNC on the routine ablation trajectory of a RF-PVI, allowing fast and effective PN screening for everyday usage. METHODS: We enrolled 137 consecutive patients (63 ± 9 years, 64% men) undergoing PVI. A detailed high output (20 mA) pace-mapping protocol was performed in the right (RA) and left atrium (LA) and adjacent vasculature. RESULTS: The right PN was most commonly captured in the superior vena cava at a lateral (50%) or posterolateral (23%) position before descending along the RA either straight (29%) or with a posterolateral bend (20%). In the LA, beginning deep within the right superior pulmonary vein (RSPV), the right PN is most frequently detectable anterolateral (31%), then descends to the lateral proximal RSPV (23%), and further towards the lateral antral region (15%) onto the medial LA wall (12%). To avoid delivering an ablation lesion on sites with PN capture, modification of ablation trajectory was necessary in 23% of cases, most commonly in the lateral RSPV antrum (81%). No PN injury occurred. CONCLUSION: PN mapping frequently reveals the close proximity of the PN to the ablation trajectory during PVI, particularly in the lateral RSPV antrum. Routine PN pacing should be considered during RF PVI procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Traumatismos dos Nervos Periféricos , Veias Pulmonares , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Nervo Frênico/lesões , Veias Pulmonares/cirurgia , Veia Cava Superior/cirurgia , Átrios do Coração/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Traumatismos dos Nervos Periféricos/diagnóstico , Traumatismos dos Nervos Periféricos/etiologia , Traumatismos dos Nervos Periféricos/prevenção & controle
3.
J Cardiovasc Electrophysiol ; 34(8): 1613-1621, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37365931

RESUMO

INTRODUCTION: Improved sinus rhythm (SR) maintenance rates have been achieved in patients with persistent atrial fibrillation (AF) undergoing pulmonary vein isolation plus additional ablation of low voltage substrate (LVS) during SR. However, voltage mapping during SR may be hindered in persistent and long-persistent AF patients by immediate AF recurrence after electrical cardioversion. We assess correlations between LVS extent and location during SR and AF, aiming to identify regional voltage thresholds for rhythm-independent delineation/detection of LVS areas. (1) Identification of voltage dissimilarities between mapping in SR and AF. (2) Identification of regional voltage thresholds that improve cross-rhythm substrate detection. (3) Comparison of LVS between SR and native versus induced AF. METHODS: Forty-one ablation-naive persistent AF patients underwent high-definition (1 mm electrodes; >1200 left atrial (LA) mapping sites per rhythm) voltage mapping in SR and AF. Global and regional voltage thresholds in AF were identified which best match LVS < 0.5 mV and <1.0 mV in SR. Additionally, the correlation between SR-LVS with induced versus native AF-LVS was assessed. RESULTS: Substantial voltage differences (median: 0.52, interquartile range: 0.33-0.69, maximum: 1.19 mV) with a predominance of the posterior/inferior LA wall exist between the rhythms. An AF threshold of 0.34 mV for the entire left atrium provides an accuracy, sensitivity and specificity of 69%, 67%, and 69% to identify SR-LVS < 0.5 mV, respectively. Lower thresholds for the posterior wall (0.27 mV) and inferior wall (0.3 mV) result in higher spatial concordance to SR-LVS (4% and 7% increase). Concordance with SR-LVS was higher for induced AF compared to native AF (area under the curve[AUC]: 0.80 vs. 0.73). AF-LVS < 0.5 mV corresponds to SR-LVS < 0.97 mV (AUC: 0.73). CONCLUSION: Although the proposed region-specific voltage thresholds during AF improve the consistency of LVS identification as determined during SR, the concordance in LVS between SR and AF remains moderate, with larger LVS detection during AF. Voltage-based substrate ablation should preferentially be performed during SR to limit the amount of ablated atrial myocardium.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/cirurgia
4.
Europace ; 25(1): 65-73, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-35852306

RESUMO

AIMS: The cornerstone of pulmonary vein (PV) isolation (PVI) is a wide-area circumferential ablation (WACA) resulting in an antral PVI area. Pulsed-field ablation (PFA) is a new nonthermal 'single-shot' PVI technique resulting in well-characterized posterior isolation areas. However, information on circumferential PVI area is lacking. Thus, we sought to characterize the circumferential antral PVI areas after PFA-PVI. METHODS AND RESULTS: Atrial fibrillation (AF) patients underwent fluoroscopy-guided PVI with a pentaspline PFA catheter. Ultra-high-density voltage maps using a 20-polar circular mapping catheter were created before and immediately after PVI to identify and quantify (i) insufficient isolation areas per antral PV segment (10-segment model) and (ii) enlarged left atrial (LA) isolation areas (beyond the antral PV segments) per LA region (8-region model). The PFA-PVI with pre- (5469 ± 1822 points) and post-mapping (6809 ± 2769 points) was performed in 40 consecutive patients [age 62 ± 6 years, 25/40 (62.5%) paroxysmal AF]. Insufficient isolation areas were located most frequently in the anterior antral PV segments of the left PVs (62.5-77.5% of patients) with the largest extent (median ≥0.4 cm2) located in the same segments (segments 2/5/8). Enlarged LA isolation areas were located most frequently and most extensively on the posterior wall and roof region (89.5-100% of patients; median 1.1-2.7 cm2 per region). CONCLUSION: Fluoroscopy-guided PFA-PVI frequently results in insufficient isolation areas in the left anterior antral PV segments and enlarged LA isolation areas on the posterior wall/roof, which both may be extensive. To optimize the procedure, full integration of PFA catheter visualization into three-dimensional-mapping systems is needed.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Catéteres , Resultado do Tratamento
5.
Europace ; 25(7)2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37410906

RESUMO

Interventional electrophysiology offers a great variety of treatment options to patients suffering from symptomatic cardiac arrhythmia. Catheter ablation of supraventricular and ventricular tachycardia has globally evolved a cornerstone in modern arrhythmia management. Complex interventional electrophysiological procedures engaging multiple ablation tools have been developed over the past decades. Fluoroscopy enabled interventional electrophysiologist throughout the years to gain profound knowledge on intracardiac anatomy and catheter movement inside the cardiac cavities and hence develop specific ablation approaches. However, the application of X-ray technologies imposes serious health risks to patients and operators. To reduce the use of fluoroscopy during interventional electrophysiological procedures to the possibly lowest degree and to establish an optimal protection of patients and operators in cases of fluoroscopy is the main goal of modern radiation management. The present manuscript gives an overview of possible strategies of fluoroscopy reduction and specific radiation protection strategies.


Assuntos
Ablação por Cateter , Exposição à Radiação , Humanos , Arritmias Cardíacas/terapia , Eletrofisiologia Cardíaca , Técnicas Eletrofisiológicas Cardíacas , Fluoroscopia/métodos , Doses de Radiação , Exposição à Radiação/efeitos adversos
6.
Europace ; 25(3): 1126-1134, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36610064

RESUMO

AIMS: Transseptal puncture (TP) for left-sided catheter ablation procedures is routinely performed under fluoroscopic or echocardiographic guidance [transoesophageal echocardiography (TEE) or intracardiac echocardiography (ICE)], although three-dimensional (3D) mapping systems are readily available in most electrophysiology laboratories. Here, we sought to assess the feasibility and safety of a right atrial (RA) 3D map-guided TP. METHODS AND RESULTS: In 104 patients, 3D RA mapping was performed to identify the fossa ovalis (FO) using the protrusion technique. The radiofrequency transseptal needle was visualized and navigated to the desired potential FO-TP site. Thereafter, the interventionalist was unblinded to TEE and the potential FO-TP site was reassessed regarding its convenience and safety. After TP, the exact TP site was documented using a 17-segment-FO model. Reliable identification of the FO was feasible in 102 patients (98%). In these, 114 3D map-guided TP attempts were performed, of which 96 (84%) patients demonstrated a good position and 18 (16%) an adequate position after TEE unblinding. An out-of-FO or dangerous position did not occur. A successful 3D map-guided TP was performed in 110 attempts (97%). Four attempts (3%) with adequate positions were aborted in order to seek a more convenient TP site. The median time from RA mapping until the end of the TP process was 13 (12-17) min. No TP-related complications occurred. Ninety-eight TP sites (85.1%) were in the central portion or in the inner loop of the FO. CONCLUSION: A 3D map-guided TP is feasible and safe. It may assist to decrease radiation exposure and the need for TEE/ICE during left-sided catheter ablation procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Estudos de Viabilidade , Cateterismo Cardíaco/métodos , Átrios do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Punções , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Resultado do Tratamento
7.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37713626

RESUMO

AIMS: Electro-anatomical voltage, conduction velocity (CV) mapping, and late gadolinium enhancement (LGE) magnetic resonance imaging (MRI) have been correlated with atrial cardiomyopathy (ACM). However, the comparability between these modalities remains unclear. This study aims to (i) compare pathological substrate extent and location between current modalities, (ii) establish spatial histograms in a cohort, (iii) develop a new estimated optimized image intensity threshold (EOIIT) for LGE-MRI identifying patients with ACM, (iv) predict rhythm outcome after pulmonary vein isolation (PVI) for persistent atrial fibrillation (AF). METHODS AND RESULTS: Thirty-six ablation-naive persistent AF patients underwent LGE-MRI and high-definition electro-anatomical mapping in sinus rhythm. Late gadolinium enhancement areas were classified using the UTAH, image intensity ratio (IIR >1.20), and new EOIIT method for comparison to low-voltage substrate (LVS) and slow conduction areas <0.2 m/s. Receiver operating characteristic analysis was used to determine LGE thresholds optimally matching LVS. Atrial cardiomyopathy was defined as LVS extent ≥5% of the left atrium (LA) surface at <0.5 mV. The degree and distribution of detected pathological substrate (percentage of individual LA surface are) varied significantly (P < 0.001) across the mapping modalities: 10% (interquartile range 0-14%) of the LA displayed LVS <0.5 mV vs. 7% (0-12%) slow conduction areas <0.2 m/s vs. 15% (8-23%) LGE with the UTAH method vs. 13% (2-23%) using IIR >1.20, with most discrepancies on the posterior LA. Optimized image intensity thresholds and each patient's mean blood pool intensity correlated linearly (R2 = 0.89, P < 0.001). Concordance between LGE-MRI-based and LVS-based ACM diagnosis improved with the novel EOIIT applied at the anterior LA [83% sensitivity, 79% specificity, area under the curve (AUC): 0.89] in comparison to the UTAH method (67% sensitivity, 75% specificity, AUC: 0.81) and IIR >1.20 (75% sensitivity, 62% specificity, AUC: 0.67). CONCLUSION: Discordances in detected pathological substrate exist between LVS, CV, and LGE-MRI in the LA, irrespective of the LGE detection method. The new EOIIT method improves concordance of LGE-MRI-based ACM diagnosis with LVS in ablation-naive AF patients but discrepancy remains particularly on the posterior wall. All methods may enable the prediction of rhythm outcomes after PVI in patients with persistent AF.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Meios de Contraste , Gadolínio , Estudos de Coortes , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Átrios do Coração/patologia , Imageamento por Ressonância Magnética/métodos , Cardiomiopatias/etiologia , Ablação por Cateter/efeitos adversos
8.
Europace ; 24(7): 1102-1111, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35298612

RESUMO

AIMS: Atrial cardiomyopathy (ACM) is associated with increased arrhythmia recurrence rates after pulmonary vein isolation (PVI). We compare the most common left atrial (LA) late gadolinium enhancement magnetic resonance imaging (LGE-MRI)-methods [Utah-method and image intensity ratio (IIR)-methods] and endocardial voltage mapping for ACM-detection and outcome prediction after PVI for atrial fibrillation (AF). METHODS AND RESULTS: In this prospective observational study, 37 ablation-naive patients (66 ± 9 years, 84% male) with persistent AF underwent LA-LGE-MRI and high-definition voltage and activation mapping (2129 ± 484 sites) in sinus rhythm prior to PVI. The MRI-post-processing-analyses were performed by two independent expert laboratories. Arrhythmia recurrence was recorded within 12 months following PVI. The global ACM-extent was highly variable: median LA low-voltage substrate (LA-LVS) was 12.9% at <1.0 mV and 2.7% at <0.5 mV; median LA-LGE-extent using the Utah-method was 18.3% and 0.03-93.1% using the IIR-methods. The LA activation time was significantly correlated with LA-LVS (r = 0.76 at <0.5 mV and r = 0.82 at <1.0 mV, both P < 0.0001), but not with LA-LGE-extent. The highest regional matching between LA-LVS <0.5 mV and LA-LGE was found for the anterior wall in 57% of patients using the Utah-method and in 59% using IIR 1.20. The corresponding values for the posterior wall were 19% and 38%, respectively. Arrhythmia recurrence occurred in 15(41%) patients. Freedom from arrhythmia was significantly lower in those with LA-LVS ≥2 cm2 at 0.5 mV but not in those with LGE ≥20% (Utah-stages III and IV): 43% vs. 81%, P = 0.009 and 50% vs. 67%, P = 0.338, respectively. CONCLUSION: Comparison of the most common LA-LGE-MRI methods and endocardial voltage mapping revealed large discrepancies in global and regional ACM-extent.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Meios de Contraste , Feminino , Gadolínio , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino
9.
Europace ; 24(8): 1256-1266, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35647644

RESUMO

AIMS: Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. METHODS AND RESULTS: This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65 min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). CONCLUSION: In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Acidente Vascular Cerebral , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Adulto Jovem
10.
Europace ; 23(12): 2010-2019, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34463710

RESUMO

AIMS: Atrial cardiomyopathy (ACM) is associated with new-onset atrial fibrillation, arrhythmia recurrence after pulmonary vein isolation (PVI) and increased risk for stroke. At present, diagnosis of ACM is feasible by endocardial contact mapping of left atrial (LA) low-voltage substrate (LVS) or late gadolinium-enhanced magnetic resonance imaging, but their complexity limits a widespread use. The aim of this study was to assess non-invasive body surface electrocardiographic imaging (ECGI) as a novel clinical tool for diagnosis of ACM compared with endocardial mapping. METHODS AND RESULTS: Thirty-nine consecutive patients (66 ± 9 years, 85% male) presenting for their first PVI for persistent atrial fibrillation underwent ECGI in sinus rhythm using a 252-electrode-array mapping system. Subsequently, high-density LA voltage and biatrial activation maps (mean 2090 ± 488 sites) were acquired in sinus rhythm prior to PVI. Freedom from arrhythmia recurrence was assessed within 12 months follow-up. Increased duration of total atrial conduction time (TACT) in ECGI was associated with both increased atrial activation time and extent of LA-LVS in endocardial contact mapping (r = 0.77 and r = 0.66, P < 0.0001 respectively). Atrial cardiomyopathy was found in 23 (59%) patients. A TACT value of 148 ms identified ACM with 91.3% sensitivity and 93.7% specificity. Arrhythmia recurrence occurred in 15 (38%) patients during a follow-up of 389 ± 55 days. Freedom from arrhythmia was significantly higher in patients with a TACT <148 ms compared with patients with a TACT ≥148 ms (82.4% vs. 45.5%, P = 0.019). CONCLUSION: Analysis of TACT in non-invasive ECGI allows diagnosis of patients with ACM, which is associated with a significantly increased risk for arrhythmia recurrence following PVI.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
11.
Europace ; 22(5): 732-738, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32142124

RESUMO

AIMS: Transseptal puncture (TP) for left atrial (LA) catheter ablation procedures is routinely performed under fluoroscopic guidance. To decrease radiation exposure and increase safety alternative techniques are desirable. The aim of this study was to assess whether right atrial (RA) electroanatomic 3D mapping can reliably identify the fossa ovalis (FO) in preparation of TP. METHODS AND RESULTS: Between May 2019 and August 2019, electroanatomic RA mapping was performed before TP in 61 patients with paroxysmal or persistent atrial fibrillation. Three electroanatomic methods for FO identification, mapping catheter-induced FO protrusion, electroanatomic-guided analysis, and voltage mapping, were evaluated and compared with transoesophageal echocardiography (TOE). Mapping catheter-induced FO protrusion was feasible in 60 patients (98%) with a mean displacement of 6.8 ± 2.5 mm, confirmed by TOE, and proofed to be the most valuable and easiest marker for FO identification. Electroanatomic-guided analysis localized the FO midpoint consistently in the lower half (43 ± 7%) and posterior (18.2 ± 4.4 mm) to a line between coronary sinus and vena cava superior. Analysis of RA voltage maps during sinus rhythm (n = 40, low-voltage cut-off value 1.0 and 1.5 mV) allowed secure FO recognition in 33% and 18%, only. A step-by-step approach, combining FO protrusion (first step) with anatomy criteria in case of protrusion failure (second step) would have allowed for the correct localization of a TP site within the FO in all patients. CONCLUSION: Right atrial electroanatomic 3D mapping prior to TP proofed to be a simple tool for FO identification and may potentially be of use in the safe and radiation-free performance of TP prior to LA ablation procedures.


Assuntos
Fibrilação Atrial , Septo Interatrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Septo Interatrial/diagnóstico por imagem , Septo Interatrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Projetos Piloto , Punções , Resultado do Tratamento
12.
Europace ; 22(2): 240-249, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31782781

RESUMO

AIMS: Presence of arrhythmogenic left atrial (LA) low-voltage substrate (LVS) is associated with reduced arthythmia freedom rates following pulmonary vein isolation (PVI) in persistent atrial fibrillation (AF). We hypothesized that LA-LVS modifies amplified sinus-P-wave (APW) characteristics, enabling identification of patients at risk for arrhythmia recurrences following PVI. METHODS AND RESULTS: Ninety-five patients with persistent AF underwent high-density (>1200 sites) voltage mapping in sinus rhythm. Left atrial low-voltage substrate (<0.5 and <1.0 mV) was quantified in a 10-segment LA model. Amplified sinus-P-wave-morphology and -duration were evaluated using digitized 12-lead electrocardiograms (40-80 mm/mV, 100-200 mm/s). 12-months arrhythmia freedom following circumferential PVI was assessed in 139 patients with persistent AF. Left atrial low-voltage substrate was most frequently (84%) found at the anteroseptal LA. Characteristic changes of APW were related to the localization and extent of LA-LVS. At an early stage, LA-LVS predominantly located to the LA-anteroseptum and was associated with APW-prolongation (≥150 ms). More extensive LA-LVS involved larger areas of LA-anteroseptum, leading to morphological changes of APW (biphasic positive-negative P-waves in inferior leads). Severe LA-LVS involved the LA-anteroseptum, roof and posterior LA, but spared the inferior LA, lateral LA, and LA appendage. In this advanced stage, widespread LVS at the posterior LA abolished the negative portion of P-wave in the inferior leads. The delayed activation of the lateral LA and LA appendage produced the late positive deflections in the anterolateral leads, resulting in the "late-terminal P"-pattern. Structured analysis of APW-duration and -morphology stratified patients to their individual extent of LA-LVS (Grade 1: mean LA-LVS 4.9 cm2 at <1.0 mV; Grade 2: 28.6 cm2; Grade 3: 42.3 cm2; P < 0.01). The diagnostic value of APW-duration for identification of LA-LVS was significantly superior to standard P-wave-amplification (c-statistic 0.945 vs. 0.647). Arrhythmia freedom following PVI differed significantly between APW-predicted grades of LA-LVS-severity [hazard ratio (HR) 2.38, 95% confidence interval (CI) 1.18-4.83; P = 0.015 for Grade 1 vs. Grade 2; HR 1.79, 95% CI 1.00-3.21, P = 0.049 for Grade 2 vs. Grade 3). Arrhythmia freedom 12 months after PVI was 77%, 53%, and 33% in Grades 1, 2 and 3, respectively. CONCLUSION: Localization and extent of LA-LVS modifies APW-morphology and -duration. Analysis of APW allows accurate prediction of LA-LVS and enables rapid and non-invasive estimation of arrhythmia freedom following PVI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Liberdade , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
13.
Europace ; 21(6): 871-878, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-31157388

RESUMO

AIMS: Sinus rhythm restoration (SRR) in patients with atrial fibrillation (AF) and heart failure may improve systolic function and impact on consecutive clinical management, but time course and potential predictors of response to SRR are uncertain. METHODS AND RESULTS: We prospectively studied 50 consecutive patients who presented in heart failure with reduced ejection fraction (EF) and concomitant AF. After exclusion of valvular and coronary artery disease patients underwent electrical cardioversion. Serial echocardiography, cardiac magnetic resonance imaging (cMRI), and 24-h electrocardiograms were performed at baseline, and on Days 3 and 40 following SRR. Baseline left ventricular EF of the study population (76% male, age 69 ± 11 years) was 30 ± 7%. Sustained SRR (≥3 days) significantly improved EF (Day 3: 43 ± 7%, n = 46; Day 40: 53 ± 9%, n = 34; P < 0.001) as quantified by echocardiography. Comparable results were obtained using cMRI (baseline: 29 ± 8%; Day 3: 42 ± 9%). Three patients showed no response to SRR (EF improvement <15%). The percentage of patients meeting current criteria for implantable cardioverter-defibrillator (ICD) implantation for primary prevention dropped from 76% (n = 38) to 11% (n = 3) on Day 40 following SRR. No specific clinical or echocardiographic factor predicting improved EF after SRR could be identified. CONCLUSION: The majority of patients presenting with non-ischaemic, non-valvular heart failure with reduced EF and concomitant AF show a significant and rapid improvement in EF following SRR. An attempt at SRR and reassessment of the need for ICD implantation after 40 days may be warranted in all such patients.


Assuntos
Fibrilação Atrial/terapia , Cardiomiopatias/terapia , Cardioversão Elétrica , Disfunção Ventricular Esquerda/terapia , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico por imagem , Eletrocardiografia , Feminino , Humanos , Masculino , Estudos Prospectivos , Volume Sistólico , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico por imagem
14.
Europace ; 21(10): 1484-1493, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31280323

RESUMO

AIMS: Atrial fibrosis contributes to arrhythmogenesis in atrial fibrillation and can be detected by MRI or electrophysiological mapping. The current study compares the spatial correlation between delayed enhancement (DE) areas to low-voltage areas (LVAs) and to arrhythmogenic areas with spatio-temporal dispersion (ST-Disp) or continuous activity (CA) in atrial fibrillation (AF). METHODS AND RESULTS: Sixteen patients with persistent AF (nine long-standing) underwent DE-magnetic resonance imaging (1.25 mm × 1.25 mm × 2.5 mm) prior to pulmonary vein isolation. Left atrial (LA) voltage mapping was acquired in AF and the regional activation patterns of 7680 AF wavelets were analysed. Sites with ST-Disp or CA were characterized (voltage, duration) and their spatial relationship to DE areas and LVAs <0.5 mV was assessed. Delayed enhancement areas and LVAs covered 55% and 24% (P < 0.01) of total LA surface, respectively. Delayed enhancement area was present at 61% of LVAs, whereas low voltage was present at 28% of DE areas. Most DE areas (72%) overlapped with atrial high-voltage areas (>0.5 mV). Spatio-temporal dispersion and CA more frequently co-localized with LVAs than with DE areas (78% vs. 63%, P = 0.02). Regional bipolar voltage of ST-Disp vs. CA was 0.64 ± 0.47 mV vs. 0.58 ± 0.51 mV. All 28 ST-Disp and 56 CA areas contained electrograms with prolonged duration (115 ± 14 ms) displaying low voltage (0.34 ± 0.11 mV). CONCLUSION: A small portion of DE areas and LVAs harbour the arrhythmogenic areas displaying ST-Disp or CA. Most arrhythmogenic activities co-localized with LVAs, while there was less co-localization with DE areas. There is an important mismatch between DE areas and LVAs which needs to be considered when used as target for catheter ablation.


Assuntos
Fibrilação Atrial/diagnóstico , Função do Átrio Esquerdo/fisiologia , Átrios do Coração/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Meglumina/farmacologia , Miocárdio/patologia , Compostos Organometálicos/farmacologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Meios de Contraste/farmacologia , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Fibrose/patologia , Gadolínio , Átrios do Coração/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
15.
Europace ; 20(2): 279-287, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28011800

RESUMO

Aims: The number of pulmonary vein isolation (PVI) ablation procedures is steadily increasing worldwide resulting in a substantial radiation exposure to patients and operators. The aim of our study was to reduce radiation exposure during these procedures to a critical amount without compromising patient safety. Methods and results: First, we assessed radiation exposure for primary PVI procedures over time (2005-2015) at the University Heart Center Freiburg-Bad Krozingen. Second, we prospectively evaluated in 52 patients, the efficacy and safety of a novel radiation reduction program (particularly applying an enhanced fluoroscopy pulse dose-reduction and optimized 3D-mapping system use). In 2035 primary PVI procedures, radiation exposure, assessed as estimated effective dose (eED in mSv, dose area product * 0.002 * conversion factor for females), fluoroscopy-time, and procedure-time decreased significantly from 2005 to 2015 (e.g. eED decreased from 9.3 (interquartile range (IQR) 6.4-13.4) mSv to 0.9 (IQR 0.5-1.6) mSv, p for trend <0.001). Importantly, application of the enhanced radiation reduction program further reduced eED to 0.4 mSv (IQR 0.3-0.6, P < 0.001 vs. control), a value not significantly different from slow-pathway ablation procedures (P = 0.41). Multiple linear regression analysis identified the radiation reduction program as the only independent variable associated with a decrease in radiation exposure. Conclusion: Radiation exposure during PVI decreased over the last decade and can further be reduced significantly by the implementation of an enhanced radiation reduction program.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Programas e Projetos de Saúde , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
16.
J Ultrasound Med ; 37(5): 1091-1101, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29034496

RESUMO

OBJECTIVES: Microembolic signal detection by transcranial Doppler ultrasonography may be considered a surrogate for cerebral events during invasive cardiac procedures. However, the impact of the microembolic signal count during pulmonary vein isolation on the clinical outcome is not well evaluated. We investigated the effect of the microembolic signal count on the occurrence of new silent cerebral embolism measured by diffusion-weighted imaging (DWI)-magnetic resonance imaging (MRI), changes in neuropsychological testing, and the occurrence of clinical events during long-term follow-up after pulmonary vein isolation. METHODS: Pulmonary vein isolation was performed in 41 patients. The total microembolic signal burden (classified into "solid," "gaseous," and "equivocal") and sustained thromboembolic showers of greater than 30 seconds were recorded. Diffusion-weighted imaging-MRI and neuropsychological testing were performed before and after pulmonary vein isolation to assess for silent cerebral embolism and neuropsychological sequelae. Long-term follow-up was performed by telephone to assess for stroke/transient ischemic attack. RESULTS: A total of 68,729 microembolic signals (14,893 solid, 11,909 gaseous, and 41,927 equivocal) with an average of 1676 signals per patient and 42 thromboembolic showers were recorded. No correlation between the microembolic signal/thromboembolic shower count and the occurrence of new DWI lesions or neuropsychological capability was found. After a mean follow-up ± SD of 49 ± 4 months, 1 patient had an overt transient ischemic event, which was not associated with a high microembolic signal count. CONCLUSIONS: In this multicenter study, we found no impact of the intraprocedural microembolic symbol/thromboembolic shower count on the occurrence of new DWI lesions, neuropsychological capability, or overt neurologic deficits after pulmonary vein isolation. Thus, not only the microembolic signal count but also procedural/individual factors may contribute to commensurable clinical damage, which may challenge this method as a valid biomarker during pulmonary vein isolation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Embolia Intracraniana/diagnóstico , Veias Pulmonares/fisiopatologia , Processamento de Sinais Assistido por Computador , Ultrassonografia Doppler Transcraniana/métodos , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Humanos , Embolia Intracraniana/complicações , Embolia Intracraniana/fisiopatologia , Imageamento por Ressonância Magnética , Masculino , Testes Neuropsicológicos , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Fatores de Risco
17.
J Cardiovasc Electrophysiol ; 25(7): 701-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24575734

RESUMO

INTRODUCTION: Pulmonary vein reconnection (PVR) is an important cause of AF recurrence after ablation. With the advent of force sensing catheters, catheter-tissue contact can be determined quantitatively. Since contact force (CF) plays a major role in determining the characteristics of RF lesion, we prospectively assessed the mechanisms of PVR with regard to catheter-contact and lesion distances in patients undergoing AF ablation. METHODS AND RESULTS: Forty symptomatic AF patients underwent wide circumferential PV isolation (PVI) with SmartTouch™ CF catheter. The exact locations of acute PVI and spontaneous or adenosine-provoked PVR were annotated on CARTO. One thousand nine hundred and twenty-six RF lesions isolated 153 PVs. PVR occurred in 35 (23%) PVs: 22 (63%) adenosine-provoked and 13 (37%) spontaneous. CF was significantly lower at PVR versus PVI sites for RF lesions within 6 mm from these sites: mean CF 5 versus 11 g (P < 0.0001) and force-time integral (FTI) 225 versus 415 gs (P < 0.0001); 86% of PVR occurred with a mean CF < 10 g (FTI < 400 gs); and the remaining 14% occurred at ablation sites with a long interlesion distance (≥5 mm) despite mean CF ≥ 10 g. Eighty percent of PVR sites were located anteriorly. There were no significant differences in regard to arrhythmia freedom between the patients without (69%) versus with PVR (67%; P = 1.0). CONCLUSIONS: Acutely durable PVI can be achieved when RF lesions are delivered with a mean CF ≥ 10 g and an interlesion distance <5 mm. The majority of PVR occur anteriorly due to inadequate CF or long interlesion distances.


Assuntos
Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Adenosina , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Tempo , Transdutores de Pressão , Resultado do Tratamento
18.
J Cardiovasc Electrophysiol ; 25(5): 479-484, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24384060

RESUMO

BACKGROUND: Transseptal puncture (TP) is a prerequisite for LA ablations. LA access can be gained by catheter probing in case of PFO (trans-PFO method) or puncture of the interatrial septum (IAS) using a transseptal needle. A 2nd access can again be gained via PFO, a 2nd TP or catheter probing of the previous puncture site (probe-TS method). This study investigates the risk factors and complications related to the mode of transseptal access. METHODS AND RESULTS: From August 2010 to August 2012, a total of 544 LA ablations, were performed. The mode of LA access was either a double TP or a single TP followed by the probe-TS or the trans-PFO method, respectively. TP was always guided by TEE and was successfully performed without complications in all cases. In contrast, 6/410 patients (1.5%) in whom catheter probing was performed (probe-TS, n = 4, trans-PFO, n = 2) had a dissection of the superior IAS originating from inside the oval fossa (n = 5) or perforation above the oval fossa (n = 1). Perforation into the pericardial space occurred in 4/6 patients, leading to one cardiac tamponade. In 5/6 patients, LA ablation was successfully completed, after repeated TP, despite effective anticoagulation. Patients with complications had the following characteristics: LA size 46 ± 4 mm, persistent AF (5/6), a repeat transseptal procedure (3/6) and a right-sided pouch (RSP, 5/6). CONCLUSIONS: Interatrial septum dissection/perforation, occasionally with perforation into the pericardial space, is an unreported complication of TP, especially with the catheter-probing techniques. An RSP is an unrecognized risk factor in this context and can be visualized by TEE.


Assuntos
Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Septo Interatrial , Cateterismo Cardíaco/métodos , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Septo Interatrial/diagnóstico por imagem , Septo Interatrial/lesões , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Tamponamento Cardíaco/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Feminino , Forame Oval Patente/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Traumatismos Cardíacos/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Punções , Radiografia Intervencionista , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
19.
Int J Cardiol Heart Vasc ; 51: 101373, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38464963

RESUMO

Background: Brugada syndrome (BrS) is characterized by dynamic ST-elevations in right precordial leads and increased risk of ventricular fibrillation and sudden cardiac death. As the mechanism underlying ST-elevation and malignant arrhythmias is controversial computational modeling can aid in exploring the disease mechanism. Thus we aim to test the main competing hypotheses ('delayed depolarization' vs. 'early repolarization') of BrS in a whole-heart computational model. Methods: In a 3D whole-heart computational model, delayed epicardial RVOT activation with local conduction delay was simulated by reducing conductivity in the epicardial RVOT. Early repolarization was simulated by instead increasing the transient outward potassium current (Ito) in the same region. Additionally, a reduction in the fast sodium current (INa) was incorporated in both models. Results: Delayed depolarization with local conduction delay in the computational model resulted in coved-type ST-elevation with negative T-waves in the precordial surface ECG leads. 'Saddleback'-shaped ST-elevation was obtained with reduced substrate extent or thickness. Increased Ito simulations showed early repolarization in the RVOT with a descending but not coved-type ST-elevation. Reduced INa did not show a significant effect on ECG morphology. Conclusions: In this whole-heart BrS computational model of both major hypotheses, realistic coved-type ECG resulted only from delayed epicardial RVOT depolarization with local conduction delay but not early repolarizing ion channel modifications. These simulations provide further support for the depolarization hypothesis as electrophysiological mechanism underlying BrS.

20.
Clin Res Cardiol ; 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38324039

RESUMO

BACKGROUND: Epicardial ablation has become an integral part of the treatment of ventricular tachycardias (VT). This study reports the safety of epicardial access as well as the efficacy of epicardial ablation of structural heart disease in a tertiary single-center experience. METHODS: Between January 2016 and February 2022, consecutive patients undergoing an epicardial access for VT ablation were included. Different puncture techniques and occurrence of epicardial access-related complications as well as the safety of ablation using non-ionic 5% dextrose in water (D5W) compared to standard 0.9% normal saline (NS) irrigation were analyzed. VT recurrence rates during a mean follow-up of 37 ± 23 months were reported. RESULTS: In total, 197 patients undergoing a total of 239 procedures were included (59.8 ± 15.3 years, 86% males). A total of 154 patients (78%) had non-ischemic cardiomyopathies with a mean LVEF of 37 ± 14. Anterior-oriented epicardial access was aimed for in all cases and was successful in 217 (91%) of all procedures, whereas access was achieved in 19 procedures (8%) only using an inferior oriented access and in three procedures (1%) using surgical access due to severe adhesions or anatomical requirements. Overall epicardial puncture-related complications occurred in 18 (8%) of all procedures with minor pericardial bleeding in nine, pericardial tamponade in one, pneumothorax in five, pneumopericardium in one, and abdominal puncture in two cases. Presence of adhesions could be identified as the only independent predictor of epicardial access-related complications. D5W was used in 79 cases and regular 0.9% saline in 117 procedures. No differences were seen regarding acute ablation success or complications. During follow-up, 47% of all patients were free from any VTs (56% D5W vs. 40% NS; log-rank p = 0.747) and 92% of clinical VTs (98% D5W vs. 91% NS; log-rank p = 0.139). CONCLUSIONS: In this large single-centre experience, epicardial access and ablation were safe and feasible. Although long-term clinical VT recurrence rates were low, overall VT recurrences as well as mortality were high advocating for a highly experienced, interdisciplinary approach including intense management of underlying cardiac disease/heart failure. Routine usage of D5W was safe and associated with comparable short- or long-term clinical or overall VT freedom.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA