Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 23(1): 1096, 2022 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-36517815

RESUMO

BACKGROUND: Previous studies have compared different kinds of fixations for anterior cruciate ligament reconstruction. Nevertheless, there is no optimal method to date. To the best of authors' knowledge, there is no article discussing the combination of adjustable suspensory device and interference screw for hybrid tibial fixation. METHODS: In total, 66 patients (n = 34, adjustable suspensory device and interference screw; n = 32, cortical screw and interference screw) were analyzed. Their International Knee Documentation Committee score and Tegner activity level scale were evaluated before and after a 2-year follow-up. The Single Assessment Numeric Evaluation score was evaluated after a 2-year follow-up. Physical exams such as range of motion, anterior knee pain (VAS > = 3) and Lachman test were assessed before and at least 12 months after surgery. To evaluate tunnel widening, anteroposterior and lateral view radiography was conducted 1 day and at least 12 months after surgery. A more than 10% change was considered tibial tunnel widening. Mann-Whitney U test, independent t test, paired t test, Fisher's exact test and chi-squared test were used to compare the variables. Linear and logistic regression models were applied to adjust for potential confounders. RESULTS: No variable except gender (P = 0.006) showed significant difference with regard to demographic data. After adjustment, there was no statistically significant difference between the groups regarding post-operative physical exams. Patients who used adjustable suspensory device and interference screw had lower post-operative Single Assessment Numeric Evaluation score (adjusted ß - 8.194; P = 0.017), Tegner activity level scale (adjusted ß - 1.295; P = 0.001) and pre-operative degrees of knee flexion (adjusted ß - 2.825; P = 0.026). Less percentage of tunnel widening in the lateral view of radiographs was seen in patients in group of adjustable suspensory device and interference screw (adjusted ß - 1.733; P = 0.038). No significant difference was observed in the anteroposterior view of radiographs (adjusted ß - 0.667; P = 0.26). CONCLUSION: In these 66 patients, we observed less tibial tunnel widening and lower post-operative functional scores in the group of adjustable suspensory device and interference screw. Both groups displayed similar outcomes of physical exams as well as improvement after operation. The proposed method may become an alternative option. Nonetheless, the quality of our study is still limited, and thus further studies are warranted to determine the efficacy and further application. TRIAL REGISTRATION: Joint Institutional Review Board of Taipei Medical University, Taipei, Taiwan (No: N201805094 ). STUDY DESIGN: Prospective comparative cohort study; Level of evidence, II.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Humanos , Estudos Prospectivos , Estudos de Coortes , Fêmur/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Articulação do Joelho/cirurgia , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/cirurgia
2.
Int J Mol Sci ; 23(23)2022 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-36498952

RESUMO

This study evaluated the mid-term (12-month) biomechanical, biocompatibility, and biological performance of additive-manufactured bioabsorbable iron-based interference screws (ISs). Two bioabsorbable iron IS types-manufactured using pure iron powder (iron_IS) and using pure iron powder with 0.2 wt% tricalcium phosphate (TCP_IS)-were compared with conventional metallic IS (control) using in vitro biocompatibility and degradation analyses and an in vivo animal study. The in vitro ultimate failure strength was significantly higher for iron_IS and TCP_IS than for control ISs at 3 months post-operatively; however, the difference between groups were nonsignificant thereafter. Moreover, at 3 months after implantation, iron_IS and TCP_IS increased bone volume fraction, bone surface area fraction, and percent intersection surface; the changes thereafter were nonsignificant. Iron_IS and TCP_IS demonstrated degradation over time with increased implant surface, decreased implant volume, and structure thickness; nevertheless, the analyses of visceral organs and biochemistry demonstrated normal results, except for time-dependent iron deposition in the spleen. Therefore, compared with conventional ISs, bioabsorbable iron-based ISs exhibit higher initial mechanical strength. Although iron-based ISs demonstrate high biocompatibility 12 months after implantation, their corrosive iron products may accumulate in the spleen. Because they demonstrate mechanical superiority along with considerable absorption capability after implantation, iron-based ISs may have potential applications in implantable medical-device development in the future.


Assuntos
Fosfatos de Cálcio , Ferro , Animais , Coelhos , Ferro/química , Porosidade , Implantes Absorvíveis
3.
Medicina (Kaunas) ; 58(9)2022 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-36143825

RESUMO

Background and objectives: Treatment of a displaced or comminuted periprosthetic distal femur fracture is challenging, especially in patients with osteoporosis. In this case report, we shared our successful surgical experience of using a long intramedullary fibula bone graft in a plate fixation surgery for a periprosthetic distal femur fracture in an extremely elderly patient with osteoporosis. Case report: A 95-year-old woman with severe osteoporosis (bone mineral density level: -3.0) presented with right knee pain and deformity after a fall, and a right periprosthetic distal femur fracture was identified. The patient underwent an open reduction and an internal plate fixation surgery with the application of a long intramedullary fibular bone graft. Due to a solid fixation, immediate weight-bearing was allowed after the surgery. She could walk independently without any valgus or varus malalignment or shortening 3 months after the surgery. A solid union was achieved 4 months postoperatively. Conclusions: We present a case wherein a long intramedullary allogenous fibula strut bone graft was used successfully to treat a right periprosthetic femur fracture in an extremely elderly patient. A long allogenous fibula bone graft can act not only as a firm structure for bridging the bone defect but also as a guide for precise component alignment. We believe this treatment option for periprosthetic fractures is beneficial for achieving biological and mechanical stability and facilitates early mobilization and weight-bearing for the patient.


Assuntos
Fraturas do Fêmur , Osteoporose , Fraturas Periprotéticas , Idoso , Idoso de 80 Anos ou mais , Placas Ósseas/efeitos adversos , Feminino , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Fêmur , Fíbula , Fixação Interna de Fraturas/efeitos adversos , Humanos , Osteoporose/complicações , Fraturas Periprotéticas/complicações , Fraturas Periprotéticas/cirurgia , Resultado do Tratamento
4.
Int J Mol Sci ; 22(14)2021 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-34298988

RESUMO

This study evaluated the biocompatibility and biological performance of novel additive-manufactured bioabsorbable iron-based porous suture anchors (iron_SAs). Two types of bioabsorbable iron_SAs, with double- and triple-helical structures (iron_SA_2_helix and iron_SA_3_helix, respectively), were compared with the synthetic polymer-based bioabsorbable suture anchor (polymer_SAs). An in vitro mechanical test, MTT assay, and scanning electron microscope (SEM) analysis were performed. An in vivo animal study was also performed. The three types of suture anchors were randomly implanted in the outer cortex of the lateral femoral condyle. The ultimate in vitro pullout strength of the iron_SA_3_helix group was significantly higher than the iron_SA_2_helix and polymer_SA groups. The MTT assay findings demonstrated no significant cytotoxicity, and the SEM analysis showed cells attachment on implant surface. The ultimate failure load of the iron_SA_3_helix group was significantly higher than that of the polymer_SA group. The micro-CT analysis indicated the iron_SA_3_helix group showed a higher bone volume fraction (BV/TV) after surgery. Moreover, both iron SAs underwent degradation with time. Iron_SAs with triple-helical threads and a porous structure demonstrated better mechanical strength and high biocompatibility after short-term implantation. The combined advantages of the mechanical superiority of the iron metal and the possibility of absorption after implantation make the iron_SA a suitable candidate for further development.


Assuntos
Implantes Absorvíveis , Materiais Biocompatíveis , Âncoras de Sutura , Alanina Transaminase/sangue , Animais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/toxicidade , Fenômenos Biomecânicos , Nitrogênio da Ureia Sanguínea , Fosfatos de Cálcio/química , Fosfatos de Cálcio/toxicidade , Sulfato de Cálcio/administração & dosagem , Sulfato de Cálcio/química , Sulfato de Cálcio/toxicidade , Creatinina/sangue , Desenho de Equipamento , Fêmur/diagnóstico por imagem , Fêmur/ultraestrutura , Ferro , Lasers , Teste de Materiais , Microscopia Eletrônica de Varredura , Estrutura Molecular , Osseointegração , Polímeros/química , Polímeros/toxicidade , Porosidade , Coelhos , Distribuição Aleatória , Resistência à Tração , Vísceras , Microtomografia por Raio-X
5.
Eur J Public Health ; 30(1): 4-9, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31177269

RESUMO

BACKGROUND: There is a lack of evidence that shows whether a report card can improve health outcomes in terms of infection rates or unscheduled readmission by using rigorous methods to evaluate its impact. METHODS: We used the National Health Insurance Administration's claims database from 1 January 2004 to 30 December 2013 and a time series analysis to evaluate the impact of the quality report card initiative on three negative outcomes of total knee replacement for each quarter of the year, including the rates of superficial infection of a knee replacement, deep infection of knee arthroplasty and unplanned readmissions for surgical site infection. RESULTS: These negative outcomes (original scale) do not show significant decreases in terms of superficial infection (-0.05‰, -0.63 to 0.53‰, P = 0.87), deep infection (-0.003‰, -0.19 to 0.18‰, P = 0.97) and unscheduled readmission (0.02‰, -0.21 to 0.25‰, P = 0.88). CONCLUSION: The total knee replacement public report card initiative did not improve the rate of infection and unscheduled readmission for surgical site infection. This report card in Taiwan should involve physicians' participation in the design and be tailored to be suitable for reading by patients in order to further enhance the chance of improvement in these negative outcomes.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Humanos , Análise de Séries Temporais Interrompida , Readmissão do Paciente , Estudos Retrospectivos , Fatores de Risco , Taiwan
6.
BMC Musculoskelet Disord ; 21(1): 667, 2020 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-33032565

RESUMO

BACKGROUND: Several cup anteversion measurements for post-operative total hip arthroplasty (THA) surgery have been described. We developed the standardized Liaw's trigonometric method to eliminate the influence of patient position, which is the most accurate method for cup anteversion measurement. We then developed an ellipse method using the Elliversion software and reported an interobserver error reduction in 2013. In this study, we attempted to apply this ellipse method in the clinic and compared its accuracy with the standard trigonometric version. METHODS: In the present study, we attempted to incorporate the ellipse method with Liaw's standardized anteversion in the simulated cup position. We measured standardized Liaw's anteversion for 434 radiographs in the clinic using the ellipse method. Repeated standard deviation (RSD) was calculated for accuracy evaluation. Furthermore, paired t-test was used for comparison with the interobserver and intraobserver errors. RESULTS: We found that the standardized Liaw's anteversion measured using the ellipse method showed lower RSD than the radiographic version. RSD was 0.795 in the standardized Liaw's anteversion with ellipse method group. The p-values of the paired t-test were all higher than 0.05 when measuring the interobserver and intraobserver errors. It indicated that the ellipse method was a precise and simple tool for cup anteversion measurement. CONCLUSION: We believe that this ellipse measurement can assist surgeons while placing the acetabulum cup into the precise position and enable early diagnosis of acetabulum loosening.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Humanos , Período Pós-Operatório , Radiografia
7.
BMC Musculoskelet Disord ; 21(1): 92, 2020 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-32041587

RESUMO

BACKGROUND: Compared to other types of surgeries, minimally invasive surgeries (MISs) of humeral shaft fractures are associated with less radial nerve injury, less soft tissue injury and higher union rate. However, malrotation often occurs in MISs when closed reduction methods are used. This study aims to define specific palpable landmarks to help surgeons determine the correct torsional angle and reduce the incidence of malrotation. METHODS: Twenty-eight normal humeral computed tomography scans were retrieved from our image database. One line was drawn through the vertices of the intertubercular sulcus of the humeral head in the coronal view, and another line was drawn through the longest axis between the medial and lateral condyles in the coronal view. The angle between these two lines was measured at least 3 times for each scan. RESULTS: The profile of the intertubercular sulcus tangent line of the humeral head and the axis of the distal humerus was identified as the most accurate method for assessing the precision of torsion during MIS for humeral shaft fractures. The transepicondylar axis line is more internally rotated than the intertubercular sulcus tangent line. The mean angle was measured to be 41.1 degrees. CONCLUSIONS: The axis of the distal humeral condyles is internally rotated by approximately 41.1 degrees compared with the intertubercular sulcus tangent line of the humeral head. Minimally invasive surgeries can be performed by using these palpable landmarks. The torsional deformities can be reduced with the proper angle adjustment without the need for fluoroscopy. It can also be used to treat unstable comminuted humeral fractures. LEVEL OF EVIDENCE: Retrospective Study, Diagnostic study, Level III.


Assuntos
Pontos de Referência Anatômicos , Fraturas do Úmero/cirurgia , Úmero/diagnóstico por imagem , Anormalidade Torcional/prevenção & controle , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fixação de Fratura/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Anormalidade Torcional/etiologia , Adulto Jovem
8.
J Foot Ankle Surg ; 55(1): 106-11, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26364234

RESUMO

Measuring bone angles is an important method for diagnosing disease and predicting the prognosis in orthopedics. Traditionally, the angle is measured using lines drawn manually and adjusted by the naked eye. The purpose of the present study was to propose new methods to measure the bone angles formed by the axes of the calcaneus with good reliability and low operational error. The 2 new methods used linear regression analysis of the points inside and on the "envelope" line. The traditional method used the vector of the lines drawn for calculation. Digital radiographs of the lateral view of the feet from 51 patients were collected, and the angles were measured using these 3 methods. Next, we analyzed the reliability, differences, and correlations of these 3 methods. The intra- and interobserver comparisons revealed significant differences between the results of the 2 new methods and those of the traditional method. In addition, the new methods had greater reliability and better intra- and interobserver correlations than did the traditional method. We suggest that these 2 new methods to measure bone axis should be added to the Picture Archiving and Communication System to obtain more reliable and standardized data in clinical practice and for future research purposes.


Assuntos
Calcâneo/diagnóstico por imagem , Ortopedia/métodos , Intensificação de Imagem Radiográfica/métodos , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes
9.
J Immunol ; 190(7): 3276-88, 2013 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-23440410

RESUMO

NOD mice exhibit major defects in the earliest stages of T cell development in the thymus. Genome-wide genetic and transcriptome analyses were used to investigate the origins and consequences of an early T cell developmental checkpoint breakthrough in Rag1-deficient NOD mice. Quantitative trait locus analysis mapped the presence of checkpoint breakthrough cells to several known NOD diabetes susceptibility regions, particularly insulin-dependent diabetes susceptibility genes (Idd)9/11 on chromosome 4, suggesting common genetic origins for T cell defects affecting this trait and autoimmunity. Genome-wide RNA deep-sequencing of NOD and B6 Rag1-deficient thymocytes revealed the effects of genetic background prior to breakthrough, as well as the cellular consequences of the breakthrough. Transcriptome comparison between the two strains showed enrichment in differentially expressed signal transduction genes, prominently tyrosine kinase and actin-binding genes, in accord with their divergent sensitivities to activating signals. Emerging NOD breakthrough cells aberrantly expressed both stem cell-associated proto-oncogenes, such as Lmo2, Hhex, Lyl1, and Kit, which are normally repressed at the commitment checkpoint, and post-ß-selection checkpoint genes, including Cd2 and Cd5. Coexpression of genes characteristic of multipotent progenitors and more mature T cells persists in the expanding population of thymocytes and in the thymic leukemias that emerge with age in these mice. These results show that Rag1-deficient NOD thymocytes have T cell defects that can collapse regulatory boundaries at two early T cell checkpoints, which may predispose them to both leukemia and autoimmunity.


Assuntos
Transformação Celular Neoplásica/genética , Proteínas de Homeodomínio/genética , Células Precursoras de Linfócitos T/metabolismo , Actinas/metabolismo , Fatores Etários , Animais , Transformação Celular Neoplásica/imunologia , Mapeamento Cromossômico , Cromossomos de Mamíferos , Análise por Conglomerados , Feminino , Perfilação da Expressão Gênica , Regulação da Expressão Gênica no Desenvolvimento , Linfoma/genética , Linfoma/imunologia , Masculino , Camundongos , Camundongos Endogâmicos NOD , Camundongos Knockout , Células Precursoras de Linfócitos T/imunologia , Locos de Características Quantitativas , Transdução de Sinais , Células-Tronco/metabolismo , Timócitos/imunologia , Timócitos/metabolismo , Transcrição Gênica
10.
Aging Ment Health ; 19(6): 548-59, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25266062

RESUMO

OBJECTIVES: Little is known about the influence of routine laboratory measurements and lifestyle factors on generic quality of life (QOL) at older ages. We aimed to study the relationship between generic QOL and laboratory measurements and lifestyle factors in community dwelling older Chinese people. METHODS: We conducted a cross-sectional analysis. Six hundred and ninety nine elders were randomly selected from the examinees of the annual health examination in Taipei City, Taiwan. Blood, urine and stool of the participants were examined and lifestyle data were collected. Participants completed the CASP-19 (control, autonomy, self-realization, pleasure) questionnaire, a 19-item QOL scale. The relationship between QOL and laboratory results and lifestyle factors was explored, using multiple linear regression and profile analysis. RESULTS: The mean age of the participants was 75.5 years (SD = 6.5), and 49.5% were female. Male gender standardized ß coefficients (ß = 0.122) and exercise habit (ß = 0.170) were associated with a better QOL, whereas advanced age (ß = -0.242), blurred vision (ß = -0.143), depression (ß = -0.125), central obesity (ß = -0.093), anemia (ß = -0.095), rheumatoid arthritis (ß = -0.073), Parkinsonism (ß = -0.079), malignancy (ß = -0.086) and motorcycle riding (ß = -0.086) were associated with a lower QOL. Profile analysis revealed that young-old males, social drinkers, regular exercisers and car drivers had the best QOL (all p < 0.001). CONCLUSION: Of the many laboratory measurements, only anemia was associated with the lower QOL. By contrast, several lifestyle factors, such as social drinking, exercise habit and car driving, were associated with better QOL, whereas abdominal obesity and motorcycle riding were associated with lower QOL.


Assuntos
Envelhecimento/fisiologia , Envelhecimento/psicologia , Avaliação Geriátrica/métodos , Vida Independente/psicologia , Estilo de Vida/etnologia , Qualidade de Vida/psicologia , Idoso , Idoso de 80 Anos ou mais , Envelhecimento/etnologia , Índice de Massa Corporal , Estudos Transversais , Análise Fatorial , Feminino , Indicadores Básicos de Saúde , Humanos , Vida Independente/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Fatores Socioeconômicos , Inquéritos e Questionários , Taiwan/epidemiologia
11.
Eur Spine J ; 23(5): 999-1006, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24395004

RESUMO

STUDY DESIGN: This is a retrospective study. PURPOSE: To compare the morphometric parameters of the psoas major and lumbar multifidus muscles in lumbar spinal stenosis (LSS) patients exhibiting different functional performance. LSS refers to symptoms related to size reduction of the lumbar spinal canal; however, the degree of stenosis is poorly related to symptom severity and functional impairments. Morphometric changes in the paraspinal muscles have been correlated with chronic lower back pain in previous studies. However, correlations between the functional performance of LSS patients and the morphometric changes in paraspinal muscles have seldom been reported. METHODS: Sixty-six LSS patients without mechanical back pain or segmental instability were enrolled in the study. A review of their medical records and MRI images was performed. Morphometric parameters, including the fatty infiltration (FI) of the lumbar multifidus muscle as well as the relative cross-sectional area (RCSA) of the psoas major and lumbar multifidus muscles, were measured. Subjects were divided into high and low functional performance groups according to their Japanese Orthopedic Association (JOA) scores. RESULTS: The male LSS patients exhibited a larger psoas RCSA than the female patients, whereas the older patients exhibited a smaller psoas RCSA and higher multifidus FI than the younger patients. LSS patients in the high functional performance group exhibited a significantly larger psoas RCSA and lower multifidus FI. CONCLUSION: The psoas RCSA and multifidus FI can be used as predictive factors for functional performance in LSS patients.


Assuntos
Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/fisiopatologia , Músculos Paraespinais/diagnóstico por imagem , Estenose Espinal/diagnóstico por imagem , Estenose Espinal/fisiopatologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Dor Lombar/etiologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Radiografia , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores Sexuais
12.
Orthop Surg ; 16(1): 276-281, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37986662

RESUMO

Improper acetabulum component position is a significant risk factor for postoperative dislocation after total hip arthroplasty. Several radiographic two-dimensional methods exist for measuring acetabulum component anteversion, but they cannot distinguish between anteversion and retroversion. "Liaw's version," initially proposed as a simple mathematical standardized two-dimensional method, was modified to the computerized ellipse method, proving superior accuracy to traditional two-dimensional methods. In this article, we demonstrated its application in detecting and measuring retroverted acetabulum component. We obtained anteroposterior pelvis radiographs from a patient undergoing total hip arthroplasty on the day of surgery and 2 weeks postoperatively. The computerized ellipse method was used to measure the acetabulum component orientation. Upon comparison, the difference between θ assigned to be retroverted (9.52-8.56 = 0.96) is much smaller than the difference between θ assigned to be anteverted (23.81-18.86 = 4.95), leading us to determine retroversion. This was further confirmed by computed tomography at the 6-week follow-up. We propose that using the computerized ellipse method to measure Liaw's version can be a valuable tool in identifying acetabulum component retroversion on anteroposterior radiographs during routine postoperative follow-up and retrospective assessments of total hip arthroplasty patients.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Estudos Retrospectivos , Radiografia , Artroplastia de Quadril/métodos
13.
Bone Rep ; 20: 101742, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38404728

RESUMO

Introduction: Fractures affect people's quality of life especially in the elders. One of the most important risk factors is osteoporosis. There are many screening tools to predict osteoporosis and fractures. We aimed to compare the predictive validity of three commonly used screening tools: fracture risk assessment tool (FRAX), osteoporosis self-assessment tool for Asians (OSTA) and one-minute osteoporosis risk test. Among them, OSTA and one-minute osteoporosis risk test were originally developed to predict osteoporosis risks and FRAX was to predict fracture risks. Methods: This is an 11-year longitudinal study. We enrolled 708 senior people from health examinees in Taiwan in 2010. A standardized questionnaire and blood tests were provided. Annual telephone interview was conducted to assess the real fracture status. We calculated risk scores of FRAX, OSTA, and one-minute osteoporosis risk test and compared with real-world fracture records. Results: The mean age of the participants were 74.9 (SD 6.4). There were 356 (50.3 %) men. From 2010 to 2020, a total of 105 (14.8 %) persons suffered from fractures. Compared to people without fractures, people with fractures had higher FRAX major osteoporotic fracture risk scores (14.0 % ± 7.6 % vs.11.3 % ± 5.7 %), higher hip fracture risk scores, and higher OSTA risk (5.9 % ± 1.4 % vs. 5.3 % ± 1.3 %). Cox regression analysis showed that hazard ratios for fracture of high FRAX risk was 1.53 (95 % confidence interval (CI) 1.05-2.21), and for high OSTA risk was 1.37 (95 % CI 1.04-1.82). Conclusions: Only OSTA and FRAX scores were satisfactory in predicting 10-year fractures.

14.
Prev Med ; 57(5): 511-7, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23872174

RESUMO

OBJECTIVE: The purpose of this study is to contribute evidence towards heterogeneity in risk factors for single and recurrent falls. METHOD: This is a prospective study conducted in Taiwan. Participants were randomly selected from the examinees of the annual health examination in 2010. Participants were interviewed with a detailed questionnaire and followed up one year later. Predictor variables included socio-demographic characteristics, medical conditions, laboratory data, and risk factors for osteoporosis. The outcome was falls in the ensuing 12 months. RESULTS: The mean age of the 653 completers was 75.6 ± 6.4. Half (48.7%) were women. Fallers and recurrent fallers comprised 14.5% and 6.0% of the participants, respectively. Blurred vision (adjusted odds ratio (aOR): 1.93, 95% confidence interval (CI): 1.02-3.67), minimal outdoor activities (aOR: 2.28, 95% CI: 1.06-4.88), and overactive thyroid/parathyroid (aOR: 3.49, 95% CI: 1.29-9.50) were associated with single falls. Frailty (aOR: 2.81, 95% CI: 1.11-7.09), decreased body height (aOR: 3.15, 95% CI: 1.52-6.54) and taking sedatives/hypnotics (aOR: 4.23, 95% CI: 2.06-8.67) were associated with recurrent falls. Previous falls (aOR: 2.64, 95% CI: 1.44-4.84 for single falls; aOR: 5.26, 95% CI: 2.61-10.60 for recurrent falls) were associated with all falls. CONCLUSION: Different intervention strategies should be developed for single and recurrent fallers.


Assuntos
Acidentes por Quedas/estatística & dados numéricos , Vida Independente/estatística & dados numéricos , Acidentes por Quedas/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Disfunção Cognitiva/epidemiologia , Estudos Transversais , Feminino , Seguimentos , Idoso Fragilizado/estatística & dados numéricos , Avaliação Geriátrica/estatística & dados numéricos , Humanos , Masculino , Estudos Prospectivos , Fatores de Risco , Prevenção Secundária , Taiwan
15.
J Arthroplasty ; 28(10): 1788-90, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23850409

RESUMO

Evaluating three-dimensional angle error is necessary because we cannot get every patient's CT or MRI at all times. Creating a method that can calculate angle error from plain radiographs is therefore important. Using vector and trigonometric mathematics, we gradually deduct our formula which can calculate angle error from goal angles (the angles we plan to achieve before operation) to result angles (the angles we get after operation) by two perpendicular radiographs. We also encode it into Micorsoft Excel (Redmond Campus, Redmond, Washington, U.S.) so that it becomes more user-friendly. We hope this tool can be used when evaluating TKR, corrective osteotomy, fracture fixation, and so on.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Humanos , Articulação do Joelho/cirurgia , Prótese do Joelho , Modelos Biológicos , Radiografia , Tíbia/cirurgia
16.
Orthop J Sports Med ; 11(1): 23259671221142242, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36636031

RESUMO

Background: Single-row (SR) and double-row repair techniques have been described to treat rotator cuff tears. We present a novel surgical strategy of arthroscopic-assisted mini-open repair in which a locking-loop suture bridge (LLSB) is used. Purpose: To compare the functional outcomes and repair integrity of LLSB technique to the SR technique for arthroscopic-assisted mini-open repair of small to medium rotator cuff tears. Study Design: Cohort study; Level of evidence, 3. Methods: Included were 39 patients who underwent LLSB repair (LLSB group) and 44 patients who underwent SR suture anchor repair (SR group) from 2015 to 2018. We evaluated all patients preoperatively and at 3, 6, 12, and 24 months postoperatively using the visual analog scale (VAS) for pain, Oxford Shoulder Score (OSS), and American Shoulder and Elbow Surgeons (ASES) score. Also, shoulder sonography was performed at 12 months postoperatively to evaluate repair integrity using the Sugaya classification system. The independent-sample t test was used to analyze functional outcomes (VAS, OSS, and ASES scores), and the Fisher exact test was used to analyze postoperative sonography results. Results: Patients in both the LLSB and SR groups saw a significant improvement on all 3 outcome measures from preoperatively to 24 months postoperatively (P < .001 for all). However, when comparing scores between groups, only the scores at 3 months postoperatively differed significantly (VAS: P = .002; OSS: P < .001; ASES: P = .005). Shoulder sonography at 12 months postoperatively revealed no significant difference in repair integrity between the LLSB and SR groups (retear rate: 10.26% and 6.82%, respectively; P = .892). Conclusion: Better outcome scores were seen at 3-month follow-up in the LLSB group, with no difference in retear rates compared with the SR group at 12 months postoperatively. The LLSB technique was found to be a reliable technique for rotator cuff repair of small- to medium-sized tears.

17.
Biomedicines ; 11(5)2023 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-37239066

RESUMO

Currently, orthopedic surgeons mainly use the inter-teardrop line (IT-line) as the transverse mechanical axis of the pelvis (TAP) for postoperative evaluation of total hip arthroplasty (THA). However, the teardrop is often unclear in the pelvis anteroposterior (AP) radiographs, which makes postoperative evaluation of THA difficult. In this study, we attempted to identify other clear and accurate axes for postoperative evaluation of THA. We calculated the mean and standard deviation of these angles and tested the significance of these angles using t-tests. The inter-teardrops line (IT line) and the upper rim of the obturator foramen (UOF) had smaller angles with the IFH line. The bi-ischial line (BI line) was relatively inaccurate in measurements. We recommend using the IT line as the TAP when the lower boundary of the teardrops is clear and the shapes of the teardrops on both sides of the pelvis are symmetrical. When there is no deformation of the obturator foramen on pelvic AP radiographs, the UOF is also a good choice for the TAP. We do not recommend the BI line as the TAP.

18.
Carbohydr Polym ; 322: 121338, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37839831

RESUMO

Machine learning (ML) has been used for many clinical decision-making processes and diagnostic procedures in bioinformatics applications. We examined eight algorithms, including linear discriminant analysis (LDA), logistic regression (LR), k-nearest neighbor (KNN), random forest (RF), gradient boosting machine (GBM), support vector machine (SVM), Naïve Bayes classifier (NB), and artificial neural network (ANN) models, to evaluate their classification and prediction capabilities for four tissue types in Wolfiporia extensa using their monosaccharide composition profiles. All 8 ML-based models were assessed as exemplary models with AUC exceeding 0.8. Five models, namely LDA, KNN, RF, GBM, and ANN, performed excellently in the four-tissue-type classification (AUC > 0.9). Additionally, all eight models were evaluated as good predictive models with AUC value > 0.8 in the three-tissue-type classification. Notably, all 8 ML-based methods outperformed the single linear discriminant analysis (LDA) plotting method. For large sample sizes, the ML-based methods perform better than traditional regression techniques and could potentially increase the accuracy in identifying tissue samples of W. extensa.


Assuntos
Wolfiporia , Teorema de Bayes , Aprendizado de Máquina , Algoritmos , Redes Neurais de Computação
19.
Anaesth Intensive Care ; 51(2): 120-129, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36523257

RESUMO

Intermediate and high-risk patients undergoing surgery are often managed on a surgical ward in the absence of haemodynamic or ventilatory support requirements necessitating intensive care unit or high dependency unit admission. We describe a model of care for the multidisciplinary management of selected postoperative patients and the epidemiology of patients managed using this model at a tertiary Australian hospital.Of 25,139 patients undergoing inpatient surgery at our institution over a two-year period, 506 (2%) were referred to the Perioperative Medicine team. The median age of patients referred was 74 years; 85% had an American Society of Anesthesiologists physical status ≥3, and 44% underwent emergency surgery. Major complication or death within 30 days was 44.2% (213/482). The most common complications, as defined by the American College of Surgeons National Surgical Quality Improvement Program were transfusion within 72 h (17.4%), pneumonia/aspiration pneumonitis (11.3%), and acute renal failure (10.6%); median time to Medical Emergency Team call was 146 (interquartile range 77-279) h.Sixty-six percent of referred patients (280/423) required an intervention during their time under the service. This high incidence indicates that this population of patients merits closer attention, including routine measurement and reporting of postoperative outcomes to monitor and improve quality of care at our institution as part of an integrated perioperative service. We believe that with so much current focus on perioperative medicine, it is important we translate this to clinical care by evolving traditional models of management into more innovative strategies to meet the complex demands of today's surgical patients.


Assuntos
Medicina Perioperatória , Humanos , Idoso , Estudos de Coortes , Complicações Pós-Operatórias/epidemiologia , Tempo de Internação , Austrália
20.
Am J Physiol Heart Circ Physiol ; 302(1): H299-311, 2012 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-22003054

RESUMO

The Mas receptor is a class I G-protein-coupled receptor that is expressed in brain, testis, heart, and kidney. The intracellular signaling pathways activated downstream of Mas are still largely unknown. In the present study, we examined the expression pattern and signaling of Mas in the heart and assessed the participation of Mas in cardiac ischemia-reperfusion injury. Mas mRNA and protein were present in all chambers of human hearts, with cardiomyocytes and coronary arteries being sites of enriched expression. Expression of Mas in either HEK293 cells or cardiac myocytes resulted in constitutive coupling to the G(q) protein, which in turn activated phospholipase C and caused inositol phosphate accumulation. To generate chemical tools for use in probing the function of Mas, we performed a library screen and chemistry optimization program to identify potent and selective nonpeptide agonists and inverse agonists. Mas agonists activated G(q) signaling in a dose-dependent manner and reduced coronary blood flow in isolated mouse and rat hearts. Conversely, treatment of isolated rat hearts with Mas inverse agonists improved coronary flow, reduced arrhythmias, and provided cardioprotection from ischemia-reperfusion injury, an effect that was due, at least in part, to decreased cardiomyocyte apoptosis. Participation of Mas in ischemia-reperfusion injury was confirmed in Mas knockout mice, which had reduced infarct size relative to mice with normal Mas expression. These results suggest that activation of Mas during myocardial infarction contributes to ischemia-reperfusion injury and further suggest that inhibition of Mas-G(q) signaling may provide a new therapeutic strategy directed at cardioprotection.


Assuntos
Cardiotônicos/farmacologia , Circulação Coronária/efeitos dos fármacos , Subunidades alfa Gq-G11 de Proteínas de Ligação ao GTP/metabolismo , Infarto do Miocárdio/prevenção & controle , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Miocárdio/metabolismo , Proteínas Proto-Oncogênicas/antagonistas & inibidores , Receptores Acoplados a Proteínas G/antagonistas & inibidores , Transdução de Sinais/efeitos dos fármacos , Animais , Animais Recém-Nascidos , Apoptose/efeitos dos fármacos , Cardiotônicos/química , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Agonismo Inverso de Drogas , Ativação Enzimática , Células HEK293 , Humanos , Fosfatos de Inositol/metabolismo , Camundongos , Camundongos Knockout , Estrutura Molecular , Infarto do Miocárdio/genética , Infarto do Miocárdio/metabolismo , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Traumatismo por Reperfusão Miocárdica/genética , Traumatismo por Reperfusão Miocárdica/metabolismo , Traumatismo por Reperfusão Miocárdica/patologia , Traumatismo por Reperfusão Miocárdica/fisiopatologia , Miocárdio/patologia , Proto-Oncogene Mas , Proteínas Proto-Oncogênicas/genética , Proteínas Proto-Oncogênicas/metabolismo , RNA Mensageiro/metabolismo , Ratos , Ratos Sprague-Dawley , Receptores Acoplados a Proteínas G/genética , Receptores Acoplados a Proteínas G/metabolismo , Fatores de Tempo , Transfecção , Fosfolipases Tipo C/metabolismo , Função Ventricular Esquerda/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA