1.
Nano Lett ; 24(35): 11002-11011, 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-39166738

RESUMO

Early stage hepatocellular carcinoma (HCC) presents a formidable challenge in clinical settings due to its asymptomatic progression and the limitations of current imaging techniques in detecting micro-HCC lesions. Addressing this critical issue, we introduce a novel ultrathin gadolinium-oxide (Gd-oxide) nanosheet-based platform with heightened sensitivity for high-field MRI and as a therapeutic agent for HCC. Synthesized via a digestive ripening process, these Gd-oxide nanosheets exhibit an exceptional acid-responsive profile. The integration of the ultrathin Gd-oxide with an acid-responsive polymer creates an ultrasensitive high-field MRI probe, enabling the visualization of submillimeter-sized tumors with superior sensitivity. Our research underscores the ultrasensitive probe's efficacy in the treatment of orthotopic HCC. Notably, the ultrasensitive probe functions dually as a companion diagnostic tool, facilitating simultaneous imaging and therapy with real-time treatment monitoring capabilities. In conclusion, this study showcases an innovative companion diagnostic tool that holds promise for the early detection and effective treatment of micro-HCC.


Assuntos
Carcinoma Hepatocelular , Meios de Contraste , Gadolínio , Neoplasias Hepáticas , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/diagnóstico , Neoplasias Hepáticas/diagnóstico por imagem , Humanos , Gadolínio/química , Meios de Contraste/química , Animais , Camundongos , Nanoestruturas/química , Nanoestruturas/uso terapêutico , Linhagem Celular Tumoral
2.
BMC Musculoskelet Disord ; 25(1): 223, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38504222

RESUMO

OBJECTIVE: Our study aimed to develop a day anterior cervical discectomy and fusion (ACDF) procedure to treat degenerative cervical spondylosis (DCS). The goal was to analyze its clinical implications, safety, and early effects to provide a better surgical option for eligible DCS patients. METHODS: A retrospective analysis was performed to identify DCS patients who underwent day ACDF from September 2022 to August 2023. The operative time, intraoperative blood loss, postoperative drainage, preoperative and postoperative visual analog scale (VAS) scores, neck disability index (NDI) scores, Japanese Orthopedic Association (JOA) scores, JOA recovery rate (RR), incidence of dysphagia-related symptoms, 30-day hospital readmission rate, and incidence of other complications were recorded to evaluate early clinical outcomes. Radiography was performed to assess the location of the implants, neurological decompression, and cervical physiological curvature. RESULTS: All 33 patients (23 women and 10 men) underwent successful surgery and experienced significant symptomatic and neurological improvements. Among them, 26 patients underwent one-segment ACDF, 5 underwent two-segment ACDF, and 2 underwent three-segment ACDF. The average operative time was 71.1 ± 20.2 min, intraoperative blood loss was 19.1 ± 6.2 mL, and postoperative drainage was 9.6 ± 5.8 mL. The preoperative VAS and NDI scores improved postoperatively (7.1 ± 1.2 vs. 3.1 ± 1.3 and 66.7% ± 4.8% vs. 24.1% ± 2.5%, respectively), with a significant difference (P < 0.01). Moreover, the preoperative JOA scores improved significantly postoperatively (7.7 ± 1.3 vs. 14.2 ± 1.4; P < 0.01) with an RR of 93.9% in good or excellent. Postoperative dysphagia-related symptoms occurred in one patient (3.0%). During the follow-up period, no patient was readmitted within 30 days after discharge; however, an incisional hematoma was reported in one patient on the 6th day after discharge, which was cured by pressure dressing. The postoperative radiographs revealed perfect implant positions and sufficient nerve decompression in all patients. Furthermore, the preoperative cervical physiological curvature improved significantly after the operation (14.5° ± 4.0° vs. 26.3° ± 5.4°; P < 0.01). CONCLUSIONS: Day ACDF has good safety and early clinical efficacy, and it could be an appropriate choice for eligible DCS patients.


Assuntos
Transtornos de Deglutição , Fusão Vertebral , Espondilose , Masculino , Humanos , Feminino , Estudos Retrospectivos , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Discotomia/efeitos adversos , Discotomia/métodos , Espondilose/diagnóstico por imagem , Espondilose/cirurgia , Resultado do Tratamento , Seguimentos
3.
Europace ; 26(1)2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38109928

RESUMO

AIMS: Pulsed field ablation (PFA) is emerging as a non-thermal, tissue-specific technique for pulmonary vein isolation (PVI) in atrial fibrillation therapy. This pre-clinical study aims to investigate the feasibility and safety of PVI using a novel PFA system including a nanosecond-scale PFA generator, a novel lotos PFA catheter, and a customized 12 Fr steerable sheath. METHODS AND RESULTS: A total of 11 Yorkshire swine were included in this study, with 4 in the acute cohort and 7 in the chronic cohort. Under general anaesthesia, transseptal puncture and pulmonary vein (PV) angiography was initially performed. The PFA catheter was navigated to position at the right and left PV antrum after the electroanatomic reconstruction of the left atrium. Biphasic PFA applications were performed on PVs in both the spindle-shaped and the lotos-shaped poses. Pulmonary vein isolation and PFA-associated safety were assessed 30 min after ablation in both cohorts and 30 days later in the chronic cohort. Detailed necropsy and histopathology were performed. Additional intracardiac echocardiography and coronary angiogram were evaluated for safety. All target PVs (n = 20) were successfully isolated on the first attempt. No spasm of coronary artery or microbubble was seen during the procedure. Eleven of 12 PVs (91.6%) remained in isolation at the 30-day invasive study. No evidence of PV stenosis was observed in any targets. However, transient diaphragm capture occurred in 17.6%. Histopathological examinations showed no evidence of collateral injury. CONCLUSION: This study provides scientific evidence demonstrating the safety and efficacy of the novel PFA catheter and system for single-shot PVI, which shows great potential.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Suínos , Animais , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Estudos de Viabilidade , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Catéteres , Resultado do Tratamento
4.
J Nanobiotechnology ; 21(1): 434, 2023 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-37980476

RESUMO

Manganese-based nanomaterials (Mn-nanomaterials) hold immense potential in cancer diagnosis and therapies. However, most Mn-nanomaterials are limited by the low sensitivity and low efficiency toward mild weak acidity (pH 6.4-6.8) of the tumor microenvironment, resulting in unsatisfactory therapeutic effect and poor magnetic resonance imaging (MRI) performance. This study introduces pH-ultrasensitive PtMn nanoparticles as a novel platform for enhanced ferroptosis-based cancer theranostics. The PtMn nanoparticles were synthesized with different diameters from 5.3 to 2.7 nm with size-dominant catalytic activity and magnetic relaxation, and modified with an acidity-responsive polymer to create pH-sensitive agents. Importantly, R-PtMn-1 (3 nm core) presents "turn-on" oxidase-like activity, affording a significant enhancement ratio (pH 6.0/pH 7.4) in catalytic activity (6.7 folds), compared with R-PtMn-2 (4.2 nm core, 3.7 folds) or R-PtMn-3 (5.3 nm core, 2.1 folds), respectively. Moreover, R-PtMn-1 exhibits dual-mode contrast in high-field MRI. R-PtMn-1 possesses a good enhancement ratio (pH 6.4/pH 7.4) that is 3 or 3.2 folds for T1- or T2-MRI, respectively, which is higher than that of R-PtMn-2 (1.4 or 1.5 folds) or R-PtMn-3 (1.1 or 1.2 folds). Moreover, their pH-ultrasensitivity enabled activation specifically within the tumor microenvironment, avoiding off-target toxicity in normal tissues during delivery. In vitro studies demonstrated elevated intracellular reactive oxygen species production, lipid peroxidation, mitochondrial membrane potential changes, malondialdehyde content, and glutathione depletion, leading to enhanced ferroptosis in cancer cells. Meanwhile, normal cells remained unaffected by the nanoparticles. Overall, the pH-ultrasensitive PtMn nanoparticles offer a promising strategy for accurate cancer diagnosis and ferroptosis-based therapy.


Assuntos
Nanopartículas , Neoplasias , Humanos , Manganês/química , Medicina de Precisão , Meios de Contraste/química , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico , Neoplasias/patologia , Imageamento por Ressonância Magnética/métodos , Nanopartículas/química , Linhagem Celular Tumoral , Microambiente Tumoral
5.
BMC Public Health ; 23(1): 2388, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-38041010

RESUMO

BACKGROUND AND OBJECTIVE: Cardiovascular disease (CVD) is the leading cause of morbidity and mortality in the United States. However, current evidence on the association between muscle quality and CVD is limited. This study investigates the potential association between the muscle quality index (MQI) and the prevalence of CVD and CVD-related mortality. METHODS: Participants were selected from the National Health and Nutrition Examination Survey (NHANES) 2011-2014. Data on mortality and causes of death were obtained from the National Death Index (NDI) records through December 31, 2019. Statistical analysis used in this study, including weighted multivariable linear and logistic regression, cox regression and Kaplan-Meier (K-M) analysis, to estimate the association between MQI and all-cause mortality as well as CVD mortality. In addition, subgroup analysis was used to estimate the association between MQI and CVD subtypes, such as heart attack, coronary heart disease, angina, congestive heart failure, and stroke. RESULTS: A total of 5,053 participants were included in the final analysis. Weighted multivariable linear regression models revealed that a lower MQI.total level was independently associated with an increased risk of CVD development in model 3, with t value =-3.48, 95%CI: (-0.24, -0.06), P = 0.002. During 5,053 person-years of 6.92 years of follow-up, there were 29 deaths from CVD. Still, the association between MQI.total and CVD mortality, as well as all-cause mortality did not reach statistical significance in the fully adjusted model (HR = 0.58, 95% CI: 0.21-1.62, P = 0.30; HR = 0.91, 95% CI:0.65,1.28, P = 0.59, respectively). Subgroup analysis confirmed that MQI.total was negatively associated with congestive heart failure (OR = 0.35, 95% CI = 0.18,0.68, P = 0.01). CONCLUSION: This study highlights the potential of MQI as a measure of muscle quality, its negative correlation with congestive heart failure (CHF). However, MQI was not very useful for predicting the health outcomes such as CVD and mortality. Therefore, more attention should be paid to the early recognition of muscle weakness progression in CHF. Further studies are needed to explore more effective indicator to evaluate the association between muscle quality and health outcomes.


Assuntos
Doenças Cardiovasculares , Insuficiência Cardíaca , Infarto do Miocárdio , Humanos , Doenças Cardiovasculares/epidemiologia , Músculos , Inquéritos Nutricionais , Estados Unidos/epidemiologia , Exercício Físico
6.
J Interv Cardiol ; 2022: 6013474, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36072362

RESUMO

Aim: We aimed to evaluate the effectiveness and safety between high-power short-duration (HPSD) radiofrequency ablation (RFA) and conventional RFA in patients with atrial fibrillation (AF). Methods: Studies comparing HPSD and traditional applications in patients undergoing initial catheter ablation for atrial fibrillation from inception through December 2021 were searched on Pubmed, Medline, Cochrane, and Clinicaltrials.gov. Results: The meta-analysis included seventeen studies with a total of 4934 patients. HPSD group decreased procedure duration (mean difference (MD) -38.28 min, P < 0.001), RF duration (MD -20.51 min, P < 0.001), fluoroscopy duration (MD -5.19 min, P < 0.001), and acute pulmonary vein reconnection (Odds ratio (OR) 0.40, P < 0.001), while improving the freedom from atrial arrhythmia at one year (OR 1.48, 95% confidence interval (CI) 1.12-1.94, P=0.005) and rates of first-pass isolation (OR 8.92, P=0.001). Compared with the conventional group, freedom from atrial arrhythmia at one-year follow-up was higher in the HPSD group without the guidance of AI/LSI (OR 1.66, P=0.01) and studies with a power setting of 40-50 W (OR 1.93, P=0.002). Nevertheless, the two groups had similar effectiveness with a power setting of 50 W in the HPSD RFA (OR 1.10, P=0.52). There was no difference in complications between the two groups (P=0.71). Conclusion: HPSD RFA was associated with shorter procedure duration, higher freedom from atrial arrhythmia, and comparable safety compared to conventional RFA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Veias Pulmonares/cirurgia , Fatores de Tempo , Resultado do Tratamento
7.
Angew Chem Int Ed Engl ; 61(31): e202117229, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35460321

RESUMO

Ferroptosis exhibits potential to damage drug-resistant cancer cells. However, it is still restricted with the "off-target" toxicity from the undesirable leakage of metal ions from ferroptosis agents, and the lack of reliable imaging for monitoring the ferroptosis process in living systems. Herein, we develop a novel ternary alloy PtWMn nanocube as a Mn reservoir, and further design a microenvironment-triggered nanoplatform that can accurately release Mn ions within the tumor to increase reactive oxygen species (ROS) generation, produce O2 and consume excess glutathione for synergistically enhancing nonferrous ferroptosis. Moreover, this nanoplatform exerts a responsive signal in high-field magnetic resonance imaging (MRI), which enables the real-time report of Mn release and the monitoring of ferroptosis initiation through the signal changes of T1 -/T2 -MRI. Thus, our nanoplatform provides a novel strategy to store, deliver and precisely release Mn ions for MRI-guided high-specificity ferroptosis therapy.


Assuntos
Ferroptose , Nanopartículas , Neoplasias , Ligas , Linhagem Celular Tumoral , Humanos , Imageamento por Ressonância Magnética/métodos , Neoplasias/patologia , Microambiente Tumoral
8.
Artigo em Inglês | MEDLINE | ID: mdl-37752407

RESUMO

Magnetic resonance imaging (MRI) is a non-invasive, radiation-free imaging technique widely used for disease detection and therapeutic evaluation due to its infinite penetration depth. Magnetic nanoparticles (MNPs) have unique magnetic and physicochemical properties, making them ideal as contrast agents for MRI. However, the in vivo toxicity of MNPs, resulting from metal ion leakage and long-term accumulation in the reticuloendothelial system (RES), limits their clinical application. To overcome these challenges, there is considerable interest in the development of renal-clearable MNPs that can be completely cleared through the kidney, reducing retention time and potential toxic risks. In this review, we provide an overview of recent advancements in the development of renal-clearable MNPs for disease imaging and treatment. We discuss the factors influencing renal clearance, summarize the types of renal-clearable MNPs, their synthesis methods, and biomedical applications. This review aims to offer comprehensive information for the design and clinical translation of renal-clearable MNPs. This article is categorized under: Nanotechnology Approaches to Biology > Nanoscale Systems in Biology Diagnostic Tools > Biosensing.


Assuntos
Nanopartículas de Magnetita , Nanopartículas de Magnetita/química , Meios de Contraste/química , Nanotecnologia , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
9.
Eur Heart J Case Rep ; 8(2): ytae054, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38362062

RESUMO

Background: Previously, ablation at the outflow tract was considered to be safe and rarely affected the His-Purkinje system due to their spatial distance. However, we have reported a case of right bundle branch block (RBBB) and junctional beats that were recorded during radiofrequency catheter ablation in a patient who had a history of peri-membranous ventricular septal defect (pmVSD) closure and the implantation of a metallic occluder. Case summary: A 16-year-old girl with a metallic occluder for peri-membranous ventricular septum defect underwent an ablation procedure for premature ventricular complexes. During the ablation at the right ventricular outflow tract (RVOT), RBBB and junctional beats were recorded. His bundle potentials and the high-frequency potential generated by electrical interference were observed when mapping the margin of the occluder. To ensure safety, we attempted ablation at the right coronary cusp in the left ventricular outflow tract, which eventually proved to be successful, presenting an alternative ablation strategy. Conclusion: This is a rare report of RBBB and junctional beats observed during ablation at RVOT in a patient with pmVSD and a metallic occluder. The observed damage to the His-Purkinje system may be attributed to uncontrolled radiofrequency energy heating up caused by the metallic device. This case emphasizes the importance of thorough electroanatomic and activation mapping prior to starting the ablation procedure, especially in complicated cases. Furthermore, it suggests that ablation at a relatively remote position is both feasible and relatively safe for patients with occluder devices.

10.
Cancer Innov ; 3(3): e116, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38947758

RESUMO

Background: With the emergence of cytotoxic T lymphocyte-associated protein-4 (CTLA-4) inhibitors, the outcomes of patients with malignant tumors have improved significantly. However, the incidence of cardiovascular adverse events has also increased, which can affect tumor treatment. In this study, we evaluated the incidence and severity of adverse cardiovascular events caused by CTLA-4 inhibitors by analyzing reported trials that involved CTLA-4 inhibitor therapy. Methods: Randomized clinical trials published in English from January 1, 2013, to November 30, 2022, were searched using the Cochrane Library and PubMed databases. All included trials examined all grade and grades 3-5 cardiac and vascular adverse events. These involved comparisons of CTLA-4 inhibitors to placebo, CTLA-4 inhibitors plus chemotherapy to chemotherapy alone, CTLA-4 inhibitors combined with PD-1/PD-L1 inhibitors to PD-1/PD-L1 inhibitors alone, and CTLA-4 inhibitors plus target agent to PD-1/PD-L1 inhibitors plus target agent. The odds ratio (OR) and corresponding 95% confidence intervals (CIs) were calculated using the Mantel-Haenszel method. Results: Overall, 20 trials were included. CTLA-4 inhibitors significantly increased the incidence of all-grade cardiovascular toxicity (OR = 1.33, 95% CI: 1.00-1.75, p = 0.05). The incidence of all-grade cardiovascular toxicity increased in malignant tumor patients who received single-agent CTLA-4 inhibitors (OR = 1.73, 95% CI: 1.13-2.65, p = 0.01), as well as the incidence rate of grades 3-5 cardiovascular adverse events (OR = 2.00, 95% CI: 1.08-3.70, p = 0.03). Compared with the non-CTLA-4 inhibitor group, CTLA-4 inhibitors plus chemotherapy, PD-1/PD-L1 inhibitors, or target agent did not significantly affect the incidence of cardiac and vascular toxicity. The incidence of grades 3-5 cardiac failure, hypertension, pericardial effusion, myocarditis, and atrial fibrillation were much higher among patients exposed to CTLA-4 inhibitor, but the data were not statistically significant. Conclusion: Our findings suggest that the incidence rate of all cardiovascular toxicity and severe cardiovascular toxicity increased in patients who were administered CTLA-4 inhibitors. In addition, the risk of serious cardiovascular toxic events was independent of the type of adverse event. From these results, physicians should assess the benefits and risks of CTLA-4 inhibitors when treating malignancies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA