Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Leg Med (Tokyo) ; 50: 101863, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33618085

RESUMO

We report allele frequencies and standard population genetics parameters for 23 forensic autosomal STR loci tested among White British population. In addition, we use generated allele frequency data to compare the extent of genetic variation with 19 other European populations.


Assuntos
Genética Populacional , Etnicidade , Medicina Legal , Frequência do Gene , Loci Gênicos , Humanos , Repetições de Microssatélites/genética , População Branca/genética
2.
Forensic Sci Int Genet ; 13: 195-205, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25178681

RESUMO

The PowerPlex(®) ESI 16 Fast, ESI 17 Fast, ESX 16 Fast, and ESX 17 Fast Systems represent faster cycling versions (50min or less) of the PowerPlex(®) ESI and ESX Systems released by Promega in 2009 to accommodate the ENFSI and EDNAP groups' call for new STR multiplexes for Europe. In addition to amplification of purified DNA samples, these new faster cycling systems allow for direct amplification from single-source blood and buccal samples deposited on FTA(®) and nonFTA paper as well as from SwabSolution™ extracts of buccal swabs without the need for purification and quantitation. There are no changes to the autosomal primer pair sequences in the PowerPlex(®) ESI Fast and ESX Fast Systems compared to the original multiplexes, and full concordance at all autosomal loci and amelogenin was observed with data generated previously with the original PowerPlex(®) ESI and ESX Systems. This paper describes the developmental validation study performed on these new fast systems following guidelines issued by the Scientific Working Group on DNA Analysis Methods (SWGDAM) and those of the DNA Advisory Board (DAB). Validation data demonstrate that these systems are sensitive for detecting low levels of DNA while also being capable of generating robust profiles from the high amount of input DNA present in direct-amplification samples. These systems are also tolerant to both high concentrations of PCR inhibitors as well as to slight variations in the final concentration of master mix and primer pair present in the amplification reaction that might be encountered due to pipetting error. The results of this validation study demonstrate that these systems may be used on multiple thermal cyclers and capillary electrophoresis platforms.


Assuntos
Impressões Digitais de DNA , Repetições de Microssatélites , Reação em Cadeia da Polimerase Multiplex/instrumentação , Animais , Degradação Necrótica do DNA , Eletroforese Capilar , Humanos , Masculino , Reprodutibilidade dos Testes , Especificidade da Espécie , Manejo de Espécimes/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA