RESUMO
Safe, effective, cost-effective, easy feasible and low-waste decontamination technologies are fundamental importance from environmental and radiation protection aspects. In this study the effectiveness of AP-CITROX decontamination technology of Inconel alloy 690 was investigated. Non-radioactive representative metal samples were formed to test of decontamination technology and the clear-, the corroded-, the decontaminated layer were analysed electrochemically. The results indicate that the passivation step of the technology was not completed.
Assuntos
Ligas , Cromo , Descontaminação/métodos , Níquel , Humanos , Análise EspectralRESUMO
Although chloride compounds are the main cause of corrosion damage in distillation unit, standard methods to determine them do not guarantee good results. In this study, the chloride concentration of different crude oils was measured using different techniques and the results were compared. ASTM D3230, D4929 as standard methods, XRF as alternative technique and Neutron Activation Analysis as reference method, were applied. It is concluded that XRF method is an effective technique for measuring the chloride concentration of oils.