Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 14(5): 243-54, 2013 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-24036878

RESUMO

To provide an alternative device for immobilization of the head while easing claustrophobia and improving comfort, an "open-face" thermoplastic mask was evaluated using video-based optical surface imaging (OSI) and kilovoltage (kV) X-ray radiography. A three-point thermoplastic head mask with a precut opening and reinforced strips was developed. After molding, it provided sufficient visible facial area as the region of interest for OSI. Using real-time OSI, the head motion of ten volunteers in the new mask was evaluated during mask locking and 15minutes lying on the treatment couch. Using a nose mark with reference to room lasers, forced head movement in open-face and full-head masks (with a nose hole) was compared. Five patients with claustrophobia were immobilized with open-face masks, set up using OSI and kV, and treated in 121 fractions, in which 61 fractions were monitored during treatment using real-time OSI. With the open-face mask, head motion was found to be 1.0 ± 0.6 mm and 0.4° ± 0.2° in volunteers during the experiment, and 0.8 ± 0.3 mm and 0.4° ± 0.2° in patients during treatment. These agree with patient motion calculated from pre-/post-treatment OSI and kV data using different anatomical landmarks. In volunteers, the head shift induced by mask-locking was 2.3 ± 1.7 mm and 1.8° ± 0.6°, and the range of forced movements in the open-face and full-head masks were found to be similar. Most (80%) of the volunteers preferred the open-face mask to the full-head mask, while claustrophobic patients could only tolerate the open-face mask. The open-face mask is characterized for its immobilization capability and can immobilize patients sufficiently (< 2 mm) during radiotherapy. It provides a clinical solution to the immobilization of patients with head and neck (HN) cancer undergoing radiotherapy, and is particularly beneficial for claustrophobic patients. This new open-face mask is readily adopted in radiotherapy clinic as a superior alternative to the standard full-head mask.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Cabeça/diagnóstico por imagem , Máscaras/normas , Transtornos Fóbicos/psicologia , Radioterapia Conformacional/métodos , Idoso , Desenho de Equipamento , Feminino , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/psicologia , Humanos , Imobilização , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Radiografia , Radioterapia Conformacional/instrumentação , Radioterapia Conformacional/psicologia
2.
Med Phys ; 39(4): 1946-63, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22482616

RESUMO

PURPOSE: Commercial CT-based image-guided radiotherapy (IGRT) systems allow widespread management of geometric variations in patient setup and internal organ motion. This document provides consensus recommendations for quality assurance protocols that ensure patient safety and patient treatment fidelity for such systems. METHODS: The AAPM TG-179 reviews clinical implementation and quality assurance aspects for commercially available CT-based IGRT, each with their unique capabilities and underlying physics. The systems described are kilovolt and megavolt cone-beam CT, fan-beam MVCT, and CT-on-rails. A summary of the literature describing current clinical usage is also provided. RESULTS: This report proposes a generic quality assurance program for CT-based IGRT systems in an effort to provide a vendor-independent program for clinical users. Published data from long-term, repeated quality control tests form the basis of the proposed test frequencies and tolerances. CONCLUSION: A program for quality control of CT-based image-guidance systems has been produced, with focus on geometry, image quality, image dose, system operation, and safety. Agreement and clarification with respect to reports from the AAPM TG-101, TG-104, TG-142, and TG-148 has been addressed.


Assuntos
Guias de Prática Clínica como Assunto , Garantia da Qualidade dos Cuidados de Saúde/normas , Radioterapia Guiada por Imagem/normas , Tomografia Computadorizada por Raios X/normas , Estados Unidos
3.
Med Phys ; 49(4): 2621-2630, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35192211

RESUMO

PURPOSE: To evaluate the efficacy of using bronchoscopically implanted anchored electromagnetic transponders (EMTs) as surrogates for 1) tumor position and 2) repeatability of lung inflation during deep-inspiration breath-hold (DIBH) lung radiotherapy. METHODS: Forty-one patients treated with either hypofractionated (HF) or conventional (CF) lung radiotherapy on an IRB-approved prospective protocol using coached DIBH were evaluated for this study. Three anchored EMTs were bronchoscopically implanted into small airways near or within the tumor. DIBH treatment was gated by tracking the EMT positions. Breath-hold cone-beam-CTs (CBCTs) were acquired prior to every HF treatment or weekly for CF patients. Retrospectively, rigid registrations between each CBCT and the breath-hold planning CT were performed to match to 1) spine, 2) EMTs and 3) tumor. Absolute differences in registration between EMTs and spine were analyzed to determine surrogacy of EMTs for lung inflation. Differences in registration between EMTs and the tumor were analyzed to determine surrogacy of EMTs for tumor position. The stability of the EMTs was evaluated by analyzing the difference between inter-EMT displacements recorded at treatment from that of the plan for the CF patients, as well as the geometric residual (GR) recorded at the time of treatment. RESULTS: A total of 219 CBCTs were analyzed. The average differences between EMT centroid and spine registration among all CBCTs were 0.45±0.42 cm, 0.29±0.28 cm, and 0.18±0.15 cm in superior-inferior (SI), anterior-posterior (AP) and lateral directions, respectively. Only 59% of CBCTs had differences in registration < 0.5 cm for EMT centroid compared to spine, indicating that lung inflation is not reproducible from simulation to treatment. The average differences between EMT centroid and tumor registration among all CBCTs were 0.13±0.13 cm, 0.14±0.13 cm and 0.12±0.12 cm in SI, AP and lateral directions, respectively. Ninety-five percent of CBCTs resulted in a < 0.5 cm change between EMT centroid and tumor registration, indicating that EMT positions correspond well with tumor position during treatments. Six out of the seven recorded CF patients had average differences in inter-EMT displacements ≤0.26 cm and average GR ≤0.22 cm, indicating that the EMTs are stable throughout treatment. CONCLUSIONS: Bronchoscopically implanted anchored EMTs are good surrogates for tumor position and are reliable for maintaining tumor position when tracked during DIBH treatment, as long as the tumor size and shape are stable. Large differences in registration between EMTs and spine for many treatments suggest that lung inflation achieved at simulation is often not reproduced.


Assuntos
Neoplasias Pulmonares , Pulmão , Suspensão da Respiração , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Estudos Prospectivos , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos
4.
Med Dosim ; 47(1): 26-31, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34426041

RESUMO

Deep inspiration breath hold (DIBH) has dosimetric advantages for lung cancer patients treated with external beam therapy, but is difficult for many patients to perform. Proton therapy permits sparing of the downstream organs at risk (OAR). We compared conventionally fractionated proton (p) and photon(x) plans on both free breathing (FB) and DIBH planning CTs to determine the effect of DIBH with proton therapy. We evaluated 24 plans from 6 lung cancer patients treated with photon DIBH on a prospective protocol. All patients were re-planned using pencil beam scanning (PBS) proton therapy. New plans were generated for FB datasets with both modalities. All plans were renormalized to 60 Gy. We evaluated dosimetric parameters for heart, lung and esophagus. We also compared FBp to DIBHx parameters to quantify how FBp plans compare to DIBHx plans. Significant differences were found for lung metrics V20 and mean lung dose between FB and DIBH plans regardless of treatment modality. Furthermore, lung metrics for FBp were comparable or superior to DIBHx, suggesting that FB protons may be a viable alternative for those patients that cannot perform DIBH with IMRT. The heart dose metrics were significantly different for the 5 out of 6 patients where the PTV overlapped the heart as DIBH moved heart out of the high dose volume. Heart dose metrics were further reduced by proton therapy. DIBH offers similar relative advantages for lung sparing for PBS as it does for IMRT but the magnitude of the DIBH related gains in OAR sparing were smaller for PBS than IMRT. FBp plans offer similar or better lung and heart sparing compared to DIBHx plans. For IMRT patients who have difficulty performing DIBH, FB protons may offer an alternative.


Assuntos
Neoplasias Pulmonares , Terapia com Prótons , Radioterapia de Intensidade Modulada , Suspensão da Respiração , Coração , Humanos , Pulmão , Neoplasias Pulmonares/radioterapia , Órgãos em Risco , Estudos Prospectivos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
5.
Technol Cancer Res Treat ; 20: 15330338211027906, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34190006

RESUMO

PURPOSE/OBJECTIVE(S): The additional personnel and imaging procedures required for Adaptive Radiation Therapy (ART) pose a challenge for a broad implementation. We hypothesize that a change in transit fluence during the treatment course is correlated with the change of quality of life and thus can be used as a replanning trigger. MATERIALS/METHODS: Twenty-one head and neck cancer (HNC) patients filled out an MD Anderson Dysphagia Inventory (MDADI) questionnaire, before-and-after the radiotherapy treatment course. The transit fluence was measured by the Watchdog (WD) in-vivo portal dosimetry system. The patients were monitored with daily WD and weekly CBCTs. The region of interest (ROI) of each patient was defined as the outer contour of the patient between approximate spine levels C1 to C4, essentially the neck and mandible inside the beam's eye view. The nth day integrated transit fluence change, Δϕn, and the volume change, ΔVROI, of the ROI of each patient was calculated from the corresponding WD and CBCT measurements. The correlation between MDADI scores and age, gender, planning mean dose to salivary glands , weight change ΔW, ΔVROI, and Δϕn, were analyzed using the ranked-Pearson correlation. RESULTS: No statistically significant correlation was found for age, gender and ΔW. was found to have clinically important correlation with functional MDADI (ρ = -0.39, P = 0.081). ΔVROI was found to have statistically significant correlation of 0.44, 0.47 and 0.44 with global, physical and functional MDADI (P-value < 0.05). Δϕn was found to have statistically significant ranked-correlation (-0.46, -0.46 and -0.45) with physical, functional and total MDADI (P-value < 0.05). CONCLUSION: A transit fluence based decision support metric (DSM) is statistically correlated with the dysphagia risk. It can not only be used as an early signal in assisting clinicians in the ART patient selection for replanning, but also lowers the resource barrier of ART implementation.


Assuntos
Transtornos de Deglutição/etiologia , Neoplasias de Cabeça e Pescoço/radioterapia , Qualidade de Vida , Adulto , Idoso , Idoso de 80 Anos ou mais , Fracionamento da Dose de Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Músculos Faríngeos , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador , Medição de Risco/métodos , Glândulas Salivares , Xerostomia/etiologia
6.
Int J Radiat Oncol Biol Phys ; 110(1): 112-123, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33516580

RESUMO

PURPOSE: We sought to investigate the tumor control probability (TCP) of spinal metastases treated with stereotactic body radiation therapy (SBRT) in 1 to 5 fractions. METHODS AND MATERIALS: PubMed-indexed articles from 1995 to 2018 were eligible for data extraction if they contained SBRT dosimetric details correlated with actuarial 2-year local tumor control rates. Logistic dose-response models of collected data were compared in terms of physical dose and 3-fraction equivalent dose. RESULTS: Data were extracted from 24 articles with 2619 spinal metastases. Physical dose TCP modeling of 2-year local tumor control from the single-fraction data were compared with data from 2 to 5 fractions, resulting in an estimated α/ß = 6 Gy, and this was used to pool data. Acknowledging the uncertainty intrinsic to the data extraction and modeling process, the 90% TCP corresponded to 20 Gy in 1 fraction, 28 Gy in 2 fractions, 33 Gy in 3 fractions, and (with extrapolation) 40 Gy in 5 fractions. The estimated TCP for common fractionation schemes was 82% at 18 Gy, 90% for 20 Gy, and 96% for 24 Gy in a single fraction, 82% for 24 Gy in 2 fractions, and 78% for 27 Gy in 3 fractions. CONCLUSIONS: Spinal SBRT with the most common fractionation schemes yields 2-year estimates of local control of 82% to 96%. Given the heterogeneity in the tumor control estimates extracted from the literature, with variability in reporting of dosimetry data and the definition of and statistical methods of reporting tumor control, care should be taken interpreting the resultant model-based estimates. Depending on the clinical intent, the improved TCP with higher dose regimens should be weighed against the potential risks for greater toxicity. We encourage future reports to provide full dosimetric data correlated with tumor local control to allow future efforts of modeling pooled data.


Assuntos
Radiocirurgia/métodos , Neoplasias da Coluna Vertebral/radioterapia , Neoplasias da Coluna Vertebral/secundário , Dor do Câncer/radioterapia , Relação Dose-Resposta à Radiação , Humanos , Modelos Logísticos , Modelos Biológicos , Modelos Teóricos , Probabilidade , Hipofracionamento da Dose de Radiação , Radiocirurgia/normas , Dosagem Radioterapêutica , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/patologia , Resultado do Tratamento , Carga Tumoral
7.
Med Phys ; 37(3): 1237-45, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20384261

RESUMO

Digital tomosynthesis (DTS) with a linear accelerator-mounted imaging system provides a means of reconstructing tomographic images from radiographic projections over a limited gantry arc, thus requiring only a few seconds to acquire. Its application in the thorax, however, often results in blurred images from respiration-induced motion. This work evaluates the feasibility of respiration-correlated (RC) DTS for soft-tissue visualization and patient positioning. Image data acquired with a gantry-mounted kilovoltage imaging system while recording respiration were retrospectively analyzed from patients receiving radiotherapy for non-small-cell lung carcinoma. Projection images spanning an approximately 30 degrees gantry arc were sorted into four respiration phase bins prior to DTS reconstruction, which uses a backprojection, followed by a procedure to suppress structures above and below the reconstruction plane of interest. The DTS images were reconstructed in planes at different depths through the patient and normal to a user-selected angle close to the center of the arc. The localization accuracy of RC-DTS was assessed via a comparison with CBCT. Evaluation of RC-DTS in eight tumors shows visible reduction in image blur caused by the respiratory motion. It also allows the visualization of tumor motion extent. The best image quality is achieved at the end-exhalation phase of the respiratory motion. Comparison of RC-DTS with respiration-correlated cone-beam CT in determining tumor position, motion extent and displacement between treatment sessions shows agreement in most cases within 2-3 mm, comparable in magnitude to the intraobserver repeatability of the measurement. These results suggest the method's applicability for soft-tissue image guidance in lung, but must be confirmed with further studies in larger numbers of patients.


Assuntos
Artefatos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto
8.
Pract Radiat Oncol ; 10(1): e45-e49, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31446148

RESUMO

Spine stereotactic body radiation therapy frequently involves the delivery of high doses to targets in proximity to the spinal cord; thus, the radiation must be delivered with great spatial accuracy. Monitoring for large shifts in target and cord position that might occur during dose delivery is a challenge for clinics equipped with a conventional C-arm Linac. Treatment must be halted, then imaging and registration must be done to determine whether a significant shift has occurred. In this retrospective study of 1019 spine SBRT treatments, we investigated the number of target shifts >2 mm in any direction that occurred in carefully immobilized patients. Orthogonal kV images were acquired 3 to 5 times during each session using in an in-room imaging system. Although the likelihood of large intrafractional shifts was found to be very low, they did occur in 6 treatment sessions. Intrafractional monitoring was found to be an important safety component of treatment delivery.


Assuntos
Lesões por Radiação/prevenção & controle , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Coluna Vertebral/radioterapia , Tomografia Computadorizada de Feixe Cônico , Fracionamento da Dose de Radiação , Humanos , Movimento , Órgãos em Risco/diagnóstico por imagem , Aceleradores de Partículas , Posicionamento do Paciente , Lesões por Radiação/etiologia , Radiocirurgia/instrumentação , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia de Intensidade Modulada/instrumentação , Estudos Retrospectivos , Medula Espinal/diagnóstico por imagem , Medula Espinal/efeitos da radiação , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Fluxo de Trabalho
9.
Int J Radiat Oncol Biol Phys ; 71(2): 484-90, 2008 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-18234445

RESUMO

PURPOSE: To report tumor control and toxicity for patients treated with image-guided intensity-modulated radiotherapy (RT) for spinal metastases with high-dose single-fraction RT. METHODS AND MATERIALS: A total of 103 consecutive spinal metastases in 93 patients without high-grade epidural spinal cord compression were treated with image-guided intensity-modulated RT to doses of 18-24 Gy (median, 24 Gy) in a single fraction between 2003 and 2006. The spinal cord dose was limited to a 14-Gy maximal dose. The patients were prospectively examined every 3-4 months with clinical assessment and cross-sectional imaging. RESULTS: The overall actuarial local control rate was 90% (local failure developed in 7 patients) at a median follow-up of 15 months (range, 2-45 months). The median time to local failure was 9 months (range, 2-15 months) from the time of treatment. Of the 93 patients, 37 died. The median overall survival was 15 months. In all cases, death was from progression of systemic disease and not local failure. The histologic type was not a statistically significant predictor of survival or local control. The radiation dose was a significant predictor of local control (p = 0.03). All patients without local failure also reported durable symptom palliation. Acute toxicity was mild (Grade 1-2). No case of radiculopathy or myelopathy has developed. CONCLUSION: High-dose, single-fraction image-guided intensity-modulated RT is a noninvasive intervention that appears to be safe and very effective palliation for patients with spinal metastases, with minimal negative effects on quality of life and a high probability of tumor control.


Assuntos
Radioterapia de Intensidade Modulada/métodos , Neoplasias da Coluna Vertebral/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Lesões por Radiação/etiologia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/efeitos adversos , Terapia de Salvação , Medula Espinal/diagnóstico por imagem , Medula Espinal/efeitos da radiação , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/mortalidade , Neoplasias da Coluna Vertebral/secundário , Taxa de Sobrevida , Fatores de Tempo
10.
Int J Radiat Oncol Biol Phys ; 71(5): 1572-80, 2008 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-18539405

RESUMO

PURPOSE: Implanted gold markers and megavoltage (MV) portal imaging are commonly used for setup verification of paraspinal tumors treated with high-dose, single-fraction radiotherapy. We investigated whether the use of kilovoltage cone-beam computed tomography (CBCT) imaging eliminates the need for marker implantation. METHODS AND MATERIALS: Patients with paraspinal disease who were eligible for single-fraction stereotactic body radiotherapy were accrued to an institutional review board-approved protocol. Each of 16 patients underwent implantation of fiducial markers near the target. The markers were visible on the MV images. Three MV image pairs were acquired for each patient (initial, verification, and final) and were registered to the reference images. Every MV pair was complemented by a CBCT scan. CBCT image registration was performed automatically by maximizing the mutual information using a region of interest that excluded the markers. The corrections, as determined from the MV images, were compared with these from CBCT and were used for actual patient setup. RESULTS: The mean and standard deviation of the absolute values of the differences between the CBCT and MV corrections were 1.0 +/- 0.7, 1.0 +/- 0.6, and 1.0 +/- 0.8 mm for the left-right, anteroposterior, and superoinferior directions, respectively. The absolute differences between the corresponding pre- and post-treatment kilovoltage CBCT image registration were 0.6 +/- 0.5, 0.6 +/- 0.5, and 1.0 +/- 0.8 mm. CONCLUSION: The setup corrections found using CBCT without the use of implanted markers were consistent with the marker registration on MV projections. CBCT has additional advantages, including better positioning precision and robust automatic three-dimensional registration, as well as eliminating the need for invasive marker implantation. We have adopted CBCT for the setup of all single-fraction paraspinal patients. Our data have also demonstrated that target displacements during treatment are insignificant.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Próteses e Implantes , Radiocirurgia/métodos , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Algoritmos , Tomografia Computadorizada de Feixe Cônico/normas , Erros de Diagnóstico , Ouro , Humanos , Movimento , Neoplasias da Coluna Vertebral/secundário , Neoplasias da Coluna Vertebral/cirurgia
11.
J Neurosurg Spine ; 28(1): 72-78, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29087812

RESUMO

OBJECTIVE The aim of this study was to evaluate the safety and efficacy of kyphoplasty treatment prior to spine stereotactic radiosurgery (SRS) in patients with spine metastases. METHODS A retrospective review of charts, radiology reports, and images was performed for all patients who received SRS (single fraction; either standalone or post-kyphoplasty) at a large tertiary cancer center between January 2012 and July 2015. Patient and tumor variables were documented, as well as treatment planning data and dosimetry. To measure the photon scatter due to polymethyl methacrylate, megavolt photon beam attenuation was determined experimentally as it passed through a kyphoplasty cement phantom. Corrected electron density values were recalculated and compared with uncorrected values. RESULTS Of 192 treatment levels in 164 unique patients who underwent single-fraction SRS, 17 (8.8%) were treated with kyphoplasty prior to radiation delivery to the index level. The median time from kyphoplasty to SRS was 22 days. Four of 192 treatments (2%) demonstrated local tumor recurrence or progression at the time of analysis. Of the 4 local failures, 1 patient had kyphoplasty prior to SRS. This recurrence occurred 18 months after SRS in the setting of widespread systemic disease and spinal tumor progression. Dosimetric review demonstrated a lower than average treatment dose for this case compared with the rest of the cohort. There were no significant differences in dosimetry analysis between the group of patients who underwent kyphoplasty prior to SRS and the remaining patients in the cohort. A preliminary analysis of polymethyl methacrylate showed that dosimetric errors due to uncorrected electron density values were insignificant. CONCLUSIONS In cases without epidural spinal cord compression, stabilization with cement augmentation prior to SRS is safe and does not alter the efficacy of the radiation or preclude physicians from adhering to SRS planning and contouring guidelines.


Assuntos
Fraturas por Compressão/cirurgia , Cifoplastia , Radiocirurgia , Fraturas da Coluna Vertebral/cirurgia , Neoplasias da Coluna Vertebral/radioterapia , Neoplasias da Coluna Vertebral/secundário , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentos Ósseos , Feminino , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Radiometria , Estudos Retrospectivos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/etiologia , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Adulto Jovem
12.
Int J Radiat Oncol Biol Phys ; 69(5): 1502-8, 2007 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-17689028

RESUMO

PURPOSE: Image-guided intensity-modulated radiotherapy enables delivery of high-dose radiation to tumors close to the spinal cord. We report our experience with multifractionated regimens using image-guided intensity-modulated radiotherapy to treat gross paraspinal disease to doses beyond cord tolerance. METHODS AND MATERIALS: We performed a retrospective review of 27 consecutive patients with partially resected or unresectable paraspinal tumors irradiated to >5,300 cGy in standard fractionation. RESULTS: The median follow-up was 17.4 months (range, 2.1-47.3). Eighteen sarcomas, seven chordomas, and two ependymomas were treated. The median dose to the planning target volume was 6,600 cGy (range, 5,396-7,080) in 180- or 200-cGy fractions. The median planning target volume was 164 cm3 (range, 29-1,116). Seven patients developed recurrence at the treatment site (26%), and 6 of these patients had high-grade tumors. Three patients with recurrence had metastatic disease at the time of radiotherapy. The 2-year local control rate was 65%, and the 2-year overall survival rate was 79%. Of the 5 patients who died, 4 had metastatic disease at death. Twenty-three patients (84%) reported either no pain or improved pain at the last follow-up visit. Sixteen patients discontinued narcotic use after treatment (62.5%). Twenty-three patients (89%) had a stable or improved American Spine Injury Association score at the last follow-up visit. No patient experienced radiation-induced myelopathy. CONCLUSIONS: The dose to paraspinal tumors has traditionally been limited to respect cord tolerance. With image-guided intensity-modulated radiotherapy, greater doses of radiation delivered in multiple fractions can be prescribed with excellent target coverage, effective palliation, and acceptable toxicity and local control.


Assuntos
Cordoma/radioterapia , Ependimoma/radioterapia , Fótons/uso terapêutico , Radioterapia de Intensidade Modulada/métodos , Sarcoma/radioterapia , Neoplasias da Coluna Vertebral/radioterapia , Adulto , Idoso , Cordoma/mortalidade , Cordoma/secundário , Fracionamento da Dose de Radiação , Ependimoma/mortalidade , Ependimoma/secundário , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radioterapia de Intensidade Modulada/efeitos adversos , Estudos Retrospectivos , Sarcoma/mortalidade , Sarcoma/secundário , Medula Espinal , Neoplasias da Coluna Vertebral/mortalidade
13.
J Radiosurg SBRT ; 4(4): 315-323, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29296455

RESUMO

INTRODUCTION: Often in clinical practice radiation oncologists encounter patients who require treatment to the spine commonly in the setting of metastatic disease. These metastases usually cause pain, immobility, or neurologic deficits mandating expedited therapy to alleviate the suffering of our patients. Spine radiosurgery techniques have been used extensively for palliation purposes; however, given the patients' deteriorating condition or pain and inability to tolerate anesthesia the radiation oncologist is often left with the conundrum of how to best set up his or her patient in preparation for radiosurgery if supine is not a viable option. In the Memorial Sloan Kettering Cancer Center several patients have been treated successfully in the lateral decubitus position to overcome this set-up issue. In this report, the feasibility of the lateral decubitus set-up for patients who benefit from radiosurgery to the spine when and if they cannot tolerate standard supine position is explored. OBJECTIVE: To report on a retrospective case series of three patients with a total of four lesions who were treated with radiosurgery for spinal metastases while set up in the lateral decubitus position. METHODS AND MATERIALS: This is a retrospective case series of 3 patients who were treated with radiosurgery to the spine for palliation of painful metastatic foci. Patients were treated in the lateral decubitus position in 1-5 fractions in order to be eligible for this retrospective case series. Their set-up data, and clinical outcomes were then compared with historic controls. RESULTS: Patients who were treated in the lateral decubitus position were set up reliably and reproducibly. Additionally clinical outcomes on routine follow-up and imaging, and toxicity profiles also corroborated the utility of this treatment set-up. CONCLUSIONS: Routinely employing optical surface tracking during patient setup followed by KVCBCT prior to treatment delivery along with intra-fractional monitoring is safe and effective while utilizing the lateral decubitus position for the treatment of spinal metastases for patients who cannot tolerate the supine position. Finally the patient follow-up also corroborated that treatments were successful thus lending credence to the safety, ease, effectiveness, and feasibility of this patient set-up.

14.
Int J Radiat Oncol Biol Phys ; 62(1): 53-61, 2005 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-15850902

RESUMO

PURPOSE: The use of image-guided and stereotactic intensity-modulated radiotherapy (IMRT) techniques have made the delivery of high-dose radiation to lesions within close proximity to the spinal cord feasible. This report presents clinical and physical data regarding the use of IMRT coupled with noninvasive body frames (stereotactic and image-guided) for multifractionated radiotherapy. METHODS AND MATERIALS: The Memorial Sloan-Kettering Cancer Center (Memorial) stereotactic body frame (MSBF) and Memorial body cradle (MBC) have been developed as noninvasive immobilizing devices for paraspinal IMRT using stereotactic (MSBF) and image-guided (MBC) techniques. Patients were either previously irradiated or prescribed doses beyond spinal cord tolerance (54 Gy in standard fractionation) and had unresectable gross disease involving the spinal canal. The planning target volume (PTV) was the gross tumor volume with a 1 cm margin. The PTV was not allowed to include the spinal cord contour. All treatment planning was performed using software developed within the institution. Isocenter verification was performed with an in-room computed tomography scan (MSBF) or electronic portal imaging devices, or both. Patients were followed up with serial magnetic resonance imaging every 3-4 months, and no patients were lost to follow-up. Kaplan-Meier statistics were used for analysis of clinical data. RESULTS: Both the MSBF and MBC were able to provide setup accuracy within 2 mm. With a median follow-up of 11 months, 35 patients (14 primary and 21 secondary malignancies) underwent treatment. The median dose previously received was 3000 cGy in 10 fractions. The median dose prescribed for these patients was 2000 cGy/5 fractions (2000-3000 cGy), which provided a median PTV V100 of 88%. In previously unirradiated patients, the median prescribed dose was 7000 cGy (5940-7000 cGy) with a median PTV V100 of 90%. The median Dmax to the cord was 34% and 68% for previously irradiated and never irradiated patients, respectively. More than 90% of patients experienced palliation from pain, weakness, or paresthesia; 75% and 81% of secondary and primary lesions, respectively, exhibited local control at the time of last follow-up. No cases of radiation-induced myelopathy or radiculopathy have thus far been encountered. CONCLUSIONS: Precision stereotactic and image-guided paraspinal IMRT allows the delivery of high doses of radiation in multiple fractions to tumors within close proximity to the spinal cord while respecting cord tolerance. Although preliminary, the clinical results are encouraging.


Assuntos
Radioterapia Conformacional/métodos , Neoplasias da Coluna Vertebral/radioterapia , Adulto , Idoso , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/instrumentação , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Resultado do Tratamento
15.
Med Phys ; 32(8): 2606-14, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16193791

RESUMO

Because of the proximity of the spinal cord, effective radiotherapy of paraspinal tumors to high doses requires highly conformal dose distributions, accurate patient setup, setup verification, and patient immobilization. An immobilization cradle has been designed to facilitate the rapid setup and radiation treatment of patients with paraspinal disease. For all treatments, patients were set up to within 2.5 mm of the design using an amorphous silicon portal imager. Setup reproducibility of the target using the cradle and associated clinical procedures was assessed by measuring the setup error prior to any correction. From 350 anterior/posterior images, and 303 lateral images, the standard deviations, as determined by the imaging procedure, were 1.3 m, 1.6 m, and 2.1 in the ant/post, right/left, and superior/inferior directions. Immobilization was assessed by measuring patient shifts between localization images taken before and after treatment. From 67 ant/post image pairs and 49 lateral image pairs, the standard deviations were found to be less than 1 mm in all directions. Careful patient positioning and immobilization has enabled us to develop a successful clinical program of high dose, conformal radiotherapy of paraspinal disease using a conventional Linac equipped with dynamic multileaf collimation and an amorphous silicon portal imager.


Assuntos
Imobilização/instrumentação , Imobilização/métodos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Neoplasias da Coluna Vertebral/radioterapia , Tomografia Computadorizada por Raios X/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação
16.
IEEE Trans Med Imaging ; 24(3): 281-92, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15754979

RESUMO

The segmentation of deformable objects from three-dimensional (3-D) images is an important and challenging problem, especially in the context of medical imagery. We present a new segmentation algorithm based on matching probability distributions of photometric variables that incorporates learned shape and appearance models for the objects of interest. The main innovation over similar approaches is that there is no need to compute a pixelwise correspondence between the model and the image. This allows for a fast, principled algorithm. We present promising results on difficult imagery for 3-D computed tomography images of the male pelvis for the purpose of image-guided radiotherapy of the prostate.


Assuntos
Algoritmos , Inteligência Artificial , Imageamento Tridimensional/métodos , Modelos Biológicos , Reconhecimento Automatizado de Padrão/métodos , Neoplasias da Próstata/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radioterapia Assistida por Computador/métodos , Simulação por Computador , Humanos , Aumento da Imagem/métodos , Armazenamento e Recuperação da Informação/métodos , Masculino , Modelos Estatísticos , Análise de Componente Principal , Neoplasias da Próstata/radioterapia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuições Estatísticas , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos
17.
Int J Radiat Oncol Biol Phys ; 91(3): 588-94, 2015 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-25680601

RESUMO

PURPOSE: To compare the potential benefits of continuous monitoring of prostate position and intervention (CMI) using 2-mm displacement thresholds during stereotactic body radiation therapy (SBRT) treatment to those of a conventional image-guided procedure involving single localization prior to treatment. METHODS AND MATERIALS: Eighty-nine patients accrued to a prostate SBRT dose escalation protocol were implanted with radiofrequency transponder beacons. The planning target volume (PTV) margin was 5 mm in all directions, except for 3 mm in the posterior direction. The prostate was kept within 2 mm of its planned position by the therapists halting dose delivery and, if necessary, correcting the couch position. We computed the number, type, and time required for interventions and where the prostate would have been during dose delivery had there been, instead, a single image-guided setup procedure prior to each treatment. Distributions of prostate displacements were computed as a function of time. RESULTS: After the initial setup, 1.7 interventions per fraction were required, with a concomitant increase in time for dose delivery of approximately 65 seconds. Small systematic drifts in prostate position in the posterior and inferior directions were observed in the study patients. Without CMI, intrafractional motion would have resulted in approximately 10% of patients having a delivered dose that did not meet our clinical coverage requirement, that is, a PTV D95 of >90%. The posterior PTV margin required for 95% of the dose to be delivered with the target positioned within the PTV was computed as a function of time. The margin necessary was found to increase by 2 mm every 5 minutes, starting from the time of the imaging procedure. CONCLUSIONS: CMI using a tight 2-mm displacement threshold was not only feasible but was found to deliver superior PTV coverage compared with the conventional image-guided procedure in the SBRT setting.


Assuntos
Posicionamento do Paciente/instrumentação , Neoplasias da Próstata/cirurgia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia/prevenção & controle , Fracionamento da Dose de Radiação , Estudos de Viabilidade , Humanos , Imageamento Tridimensional , Masculino , Radioterapia de Intensidade Modulada , Fatores de Tempo
18.
Med Phys ; 42(6): 2813-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26127033

RESUMO

PURPOSE: To investigate constancy, within a treatment session, of the time lag relationship between implanted markers in abdominal tumors and an external motion surrogate. METHODS: Six gastroesophageal junction and three pancreatic cancer patients (IRB-approved protocol) received two cone-beam CTs (CBCT), one before and one after treatment. Time between scans was less than 30 min. Each patient had at least one implanted fiducial marker near the tumor. In all scans, abdominal displacement (Varian RPM) was recorded as the external motion signal. Purpose-built software tracked fiducials, representing internal signal, in CBCT projection images. Time lag between superior-inferior (SI) internal and anterior-posterior external signals was found by maximizing the correlation coefficient in each breathing cycle and averaging over all cycles. Time-lag-induced discrepancy between internal SI position and that predicted from the external signal (external prediction error) was also calculated. RESULTS: Mean ± standard deviation time lag, over all scans and patients, was 0.10 ± 0.07 s (range 0.01-0.36 s). External signal lagged the internal in 17/18 scans. Change in time lag between pre- and post-treatment CBCT was 0.06 ± 0.07 s (range 0.01-0.22 s), corresponding to 3.1% ± 3.7% (range 0.6%-10.8%) of gate width (range 1.6-3.1 s). In only one patient, change in time lag exceeded 10% of the gate width. External prediction error over all scans of all patients varied from 0.1 ± 0.1 to 1.6 ± 0.4 mm. CONCLUSIONS: Time lag between internal motion along SI and external signals is small compared to the treatment gate width of abdominal patients examined in this study. Change in time lag within a treatment session, inferred from pre- to post-treatment measurements is also small, suggesting that a single measurement of time lag at the session start is adequate. These findings require confirmation in a larger number of patients.


Assuntos
Fracionamento da Dose de Radiação , Neoplasias Gastrointestinais/fisiopatologia , Neoplasias Gastrointestinais/radioterapia , Movimento , Neoplasias Pancreáticas/fisiopatologia , Neoplasias Pancreáticas/radioterapia , Tomografia Computadorizada de Feixe Cônico , Marcadores Fiduciais , Neoplasias Gastrointestinais/diagnóstico por imagem , Humanos , Neoplasias Pancreáticas/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador , Fatores de Tempo
19.
Int J Radiat Oncol Biol Phys ; 55(3): 583-93, 2003 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-12573745

RESUMO

PURPOSE: To design and implement a noninvasive stereotactic immobilization technique with daily CT image-guided positioning to treat patients with paraspinal lesions accurately and to quantify the systematic and random patient setup errors occurring with this method. METHODS AND MATERIALS: A stereotactic body frame (SBF) was developed for "rigid" immobilization of paraspinal patients. The inherent accuracy of this system for stereotactic CT-guided treatment was evaluated with phantom studies. Seven patients with thoracic and lumbar spine lesions were immobilized with the SBF and positioned for 33 treatment fractions using daily CT scans. For all 7 patients, the daily setup errors, as assessed from the daily CT scans, were corrected at each treatment fraction. A retrospective analysis was also performed to assess what the impact on patient treatment would have been without the CT-based corrections (i.e., if patient setup had been performed only with the SBF). RESULTS: The average magnitude of systematic and random errors from uncorrected patient setups using the SBF was approximately 2 mm and 1.5 mm (1 SD), respectively. For fixed phantom targets, the system accuracy for the SBF localization and treatment was shown to be within 1 mm (1 SD) in any direction. Dose-volume histograms incorporating these uncertainties for an intensity-modulated radiotherapy plan for lumbar spine lesions were generated, and the effects on the dose-volume histograms were studied. CONCLUSION: We demonstrated a very accurate and precise method of patient immobilization and treatment delivery based on a noninvasive SBF and daily image guidance for paraspinal lesions. The SBF provides excellent immobilization for paraspinal targets, with setup accuracy better than 2 mm (1 SD). However, for highly conformal paraspinal treatments, uncorrected systematic and random errors of 2 mm in magnitude can result in a significantly greater (>100%) dose to the spinal cord than planned, even though the planned target coverage may not change substantially. With daily CT guidance using the SBF, we showed that the maximal spinal cord dose is ensured to be within 10-15% of the planned value.


Assuntos
Imobilização , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias da Coluna Vertebral/radioterapia , Técnicas Estereotáxicas , Tomografia Computadorizada por Raios X , Humanos , Vértebras Lombares , Movimento , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/normas , Reprodutibilidade dos Testes , Estudos Retrospectivos , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Vértebras Torácicas
20.
Int J Radiat Oncol Biol Phys ; 55(3): 811-24, 2003 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-12573769

RESUMO

PURPOSE: Delivering high dose to prostate with external beam radiation has been shown to improve local tumor control. However, it has to be carefully performed to avoid partial target miss and delivering excessive dose to surrounding normal tissues. One way to achieve safe dose escalation is to precisely localize prostate immediately before daily treatment. Therefore, the radiation can be accurately delivered to the target. Once the prostate position is determined with high confidence, planning target volume (PTV) safety margin might be reduced for further reduction of rectal toxicity. A rapid computed tomography (CT)-based online prostate localization method is presented for this purpose. METHODS AND MATERIALS: Immediately before each treatment session, the patient is immobilized and undergoes a CT scan in the treatment position using a CT scanner situated in the treatment room. At the CT console, posterior, anterior, left, and right extents of the prostate are manually identified on each axial slice. The translational prostate displacements relative to the planned position are estimated by simultaneously fitting these identified extents from this CT scan to a template created from the finely sliced planning CT scan. A total of 106 serial CT scans from 8 prostate cancer patients were performed immediately before treatments and used to retrospectively evaluate the precision of this daily prostate targeting method. The three-dimensional displacement of the prostate with respect to its planned position was estimated. RESULTS: Five axial slices from each treatment CT scan were sufficient to produce a reliable correction when compared with prostate center of gravity (CoG) displacements calculated from physician-drawn contours. The differences (mean +/- SD) between these two correction schemes in the right-left (R/L), posterior-anterior (P/A), and superior-inferior (S/I) directions are 0.0 +/- 0.4 mm, 0.0 +/- 0.7 mm, and -0.4 +/- 1.9 mm, respectively. With daily CT extent-fitting correction, 97% of the scans showed that the entire posterior prostate gland was covered by PTV given a margin of 6 mm at the rectum-prostate interface and 10 mm elsewhere. In comparison, only 74% and 65% could be achieved by the corrections based on daily and weekly bony matching on portal images, respectively. CONCLUSIONS: Results show that daily CT extent fitting provides a precise correction of prostate position in terms of CoG. Identifying prostate extents on five axial CT slices at the CT console is less time-consuming compared with daily contouring of the prostate on many slices. Taking advantage of the prostate curvature in the longitudinal direction, this method also eliminates the necessity of identifying prostate base and apex. Therefore, it is clinically feasible and should provide an accelerated localization of the prostate immediately before daily treatment.


Assuntos
Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Lesões por Radiação/prevenção & controle , Planejamento da Radioterapia Assistida por Computador/instrumentação , Doenças Retais/prevenção & controle , Estudos de Viabilidade , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Radiografia , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA