Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 197
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
CA Cancer J Clin ; 72(1): 34-56, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34792808

RESUMO

Radiation therapy (RT) continues to play an important role in the treatment of cancer. Adaptive RT (ART) is a novel method through which RT treatments are evolving. With the ART approach, computed tomography or magnetic resonance (MR) images are obtained as part of the treatment delivery process. This enables the adaptation of the irradiated volume to account for changes in organ and/or tumor position, movement, size, or shape that may occur over the course of treatment. The advantages and challenges of ART maybe somewhat abstract to oncologists and clinicians outside of the specialty of radiation oncology. ART is positioned to affect many different types of cancer. There is a wide spectrum of hypothesized benefits, from small toxicity improvements to meaningful gains in overall survival. The use and application of this novel technology should be understood by the oncologic community at large, such that it can be appropriately contextualized within the landscape of cancer therapies. Likewise, the need to test these advances is pressing. MR-guided ART (MRgART) is an emerging, extended modality of ART that expands upon and further advances the capabilities of ART. MRgART presents unique opportunities to iteratively improve adaptive image guidance. However, although the MRgART adaptive process advances ART to previously unattained levels, it can be more expensive, time-consuming, and complex. In this review, the authors present an overview for clinicians describing the process of ART and specifically MRgART.


Assuntos
Imagem por Ressonância Magnética Intervencionista/métodos , Neoplasias/radioterapia , Aceleradores de Partículas , Radioterapia (Especialidade)/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , História do Século XX , História do Século XXI , Humanos , Imagem por Ressonância Magnética Intervencionista/história , Imagem por Ressonância Magnética Intervencionista/instrumentação , Imagem por Ressonância Magnética Intervencionista/tendências , Neoplasias/diagnóstico por imagem , Radioterapia (Especialidade)/história , Radioterapia (Especialidade)/instrumentação , Radioterapia (Especialidade)/tendências , Planejamento da Radioterapia Assistida por Computador/história , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/tendências
2.
Lancet ; 399(10338): 1886-1901, 2022 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-35569466

RESUMO

BACKGROUND: In men with a detectable prostate-specific antigen (PSA) level after prostatectomy for prostate cancer, salvage prostate bed radiotherapy (PBRT) results in about 70% of patients being free of progression at 5 years. A three-group randomised trial was designed to determine whether incremental gains in patient outcomes can be achieved by adding either 4-6 months of short-term androgen deprivation therapy (ADT) to PBRT, or both short-term ADT and pelvic lymph node radiotherapy (PLNRT) to PBRT. METHODS: The international, multicentre, randomised, controlled SPPORT trial was done at 283 radiation oncology cancer treatment centres in the USA, Canada, and Israel. Eligible patients (aged ≥18 years) were those who after prostatectomy for adenocarcinoma of the prostate had a persistently detectable or an initially undetectable and rising PSA of between 0·1 and 2·0 ng/mL. Patients with and without lymphadenectomy (N0/Nx) were eligible if there was no clinical or pathological evidence of lymph node involvement. Other eligibility criteria included pT2 or pT3 disease, prostatectomy Gleason score of 9 or less, and a Zubrod performance status of 0-1. Eligible patients were randomly assigned to receive PBRT alone at a dose of 64·8-70·2 Gy at 1·8 Gy per fraction daily (group 1), PBRT plus short-term ADT (group 2), or PLNRT (45 Gy at 1·8 Gy per fraction, and then a volume reduction made to the planning target volume for the remaining 19·8-25 ·2 Gy) plus PBRT plus short-term ADT (group 3). The primary endpoint was freedom from progression, in which progression was defined as biochemical failure according to the Phoenix definition (PSA ≥2 ng/mL over the nadir PSA), clinical failure (local, regional, or distant), or death from any cause. A planned interim analysis of 1191 patents with minimum potential follow-up time of 5 years applied a Haybittle-Peto boundary of p<0·001 (one sided) for comparison of 5-year freedom from progression rates between the treatment groups. This trial is registered with ClinicalTrials.gov, NCT00567580. The primary objectives of the trial have been completed, although long-term follow-up is continuing. FINDINGS: Between March 31, 2008, and March 30, 2015, 1792 eligible patients were enrolled and randomly assigned to the three treatment groups (592 to group 1 [PBRT alone], 602 to group 2 [PBRT plus short-term ADT], and 598 to group 3 [PLNRT plus PBRT plus short-term ADT]). 76 patients subsequently found to be ineligible were excluded from the analyses; thus, the evaluable patient population comprised 1716 patients. At the interim analysis (n=1191 patients; data cutoff May 23, 2018), the Haybittle-Peto boundary for 5-year freedom from progression was exceeded when group 1 was compared with group 3 (difference 17·9%, SE 2·9%; p<0·0001). The difference between groups 2 and 3 did not exceed the boundary (p=0·0063). With additional follow-up beyond the interim analysis (the final planned analysis; data cutoff May 26, 2021), at a median follow-up among survivors of 8·2 years (IQR 6·6-9·4), the 5-year freedom from progression rates in all 1716 eligible patients were 70·9% (95% CI 67·0-74·9) in group 1, 81·3% (78·0-84·6) in group 2, and 87·4% (84·7-90·2) in group 3. Per protocol criteria, freedom from progression in group 3 was superior to groups 1 and 2. Acute (≤3 months after radiotherapy) grade 2 or worse adverse events were significantly more common in group 3 (246 [44%] of 563 patients) than in group 2 (201 [36%] of 563; p=0·0034), which, in turn, were more common than in group 1 (98 [18%] of 547; p<0·0001). Similar findings were observed for grade 3 or worse adverse events. However, late toxicity (>3 months after radiotherapy) did not differ significantly between the groups, apart from more late grade 2 or worse blood or bone marrow events in group 3 versus group 2 (one-sided p=0·0060) attributable to the addition of PLNRT in this group. INTERPRETATION: The results of this randomised trial establish the benefit of adding short-term ADT to PBRT to prevent progression in prostate cancer. To our knowledge, these are the first such findings to show that extending salvage radiotherapy to treat the pelvic lymph nodes when combined with short-term ADT results in meaningful reductions in progression after prostatectomy in patients with prostate cancer. FUNDING: National Cancer Institute.


Assuntos
Neoplasias da Próstata , Radioterapia (Especialidade) , Adolescente , Adulto , Antagonistas de Androgênios/uso terapêutico , Androgênios , Humanos , Linfonodos/patologia , Masculino , Próstata/patologia , Antígeno Prostático Específico , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/radioterapia , Terapia de Salvação/efeitos adversos
3.
J Appl Clin Med Phys ; 22(8): 303-309, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34231963

RESUMO

PURPOSE: To estimate the overall spatial distortion on clinical patient images for a 0.35 T MR-guided radiotherapy system. METHODS: Ten patients with head-and-neck cancer underwent CT and MR simulations with identical immobilization. The MR images underwent the standard systematic distortion correction post-processing. The images were rigidly registered and landmark-based analysis was performed by an anatomical expert. Distortion was quantified using Euclidean distance between each landmark pair and tagged by tissue interface: bone-tissue, soft tissue, or air-tissue. For baseline comparisons, an anthropomorphic phantom was imaged and analyzed. RESULTS: The average spatial discrepancy between CT and MR landmarks was 1.15 ± 1.14 mm for the phantom and 1.46 ± 1.78 mm for patients. The error histogram peaked at 0-1 mm. 66% of the discrepancies were <2 mm and 51% <1 mm. In the patient data, statistically significant differences (p-values < 0.0001) were found between the different tissue interfaces with averages of 0.88 ± 1.24 mm, 2.01 ± 2.20 mm, and 1.41 ± 1.56 mm for the air/tissue, bone/tissue, and soft tissue, respectively. The distortion generally correlated with the in-plane radial distance from the image center along the longitudinal axis of the MR. CONCLUSION: Spatial distortion remains in the MR images after systematic distortion corrections. Although the average errors were relatively small, large distortions observed at bone/tissue interfaces emphasize the need for quantitative methods for assessing and correcting patient-specific spatial distortions.


Assuntos
Imageamento por Ressonância Magnética , Planejamento da Radioterapia Assistida por Computador , Humanos , Imagens de Fantasmas
4.
J Appl Clin Med Phys ; 18(3): 163-169, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28436094

RESUMO

PURPOSE: Magnetic resonance image (MRI) guided radiotherapy enables gating directly on the target position. We present an evaluation of an MRI-guided radiotherapy system's gating performance using an MRI-compatible respiratory motion phantom and radiochromic film. Our evaluation is geared toward validation of our institution's clinical gating protocol which involves planning to a target volume formed by expanding 5 mm about the gross tumor volume (GTV) and gating based on a 3 mm window about the GTV. METHODS: The motion phantom consisted of a target rod containing high-contrast target inserts which moved in the superior-inferior direction inside a body structure containing background contrast material. The target rod was equipped with a radiochromic film insert. Treatment plans were generated for a 3 cm diameter spherical planning target volume, and delivered to the phantom at rest and in motion with and without gating. Both sinusoidal trajectories and tumor trajectories measured during MRI-guided treatments were used. Similarity of the gated dose distribution to the planned, motion-frozen, distribution was quantified using the gamma technique. RESULTS: Without gating, gamma pass rates using 4%/3 mm criteria were 22-59% depending on motion trajectory. Using our clinical standard of repeated breath holds and a gating window of 3 mm with 10% target allowed outside the gating boundary, the gamma pass rate was 97.8% with 3%/3 mm gamma criteria. Using a 3 mm window and 10% allowed excursion, all of the patient tumor motion trajectories at actual speed resulting in at least 95% gamma pass rate at 4%/3 mm. CONCLUSIONS: Our results suggest that the device can be used to compensate respiratory motion using a 3 mm gating margin and 10% allowed excursion results in conjunction with repeated breath holds. Full clinical validation requires a comprehensive evaluation of tracking performance in actual patient images, outside the scope of this study.


Assuntos
Imageamento por Ressonância Magnética , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem/instrumentação , Dosimetria Fotográfica , Humanos , Movimento , Imagens de Fantasmas , Radiometria , Respiração
5.
J Appl Clin Med Phys ; 17(4): 377-390, 2016 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-27455472

RESUMO

CT image reconstruction is typically evaluated based on the ability to reduce the radiation dose to as-low-as-reasonably-achievable (ALARA) while maintaining acceptable image quality. However, the determination of common image quality metrics, such as noise, contrast, and contrast-to-noise ratio, is often insufficient for describing clinical radiotherapy task performance. In this study we designed and implemented a new comparative analysis method associating image quality, radiation dose, and patient size with radiotherapy task performance, with the purpose of guiding the clinical radiotherapy usage of CT reconstruction algorithms. The iDose4 iterative reconstruction algorithm was selected as the target for comparison, wherein filtered back-projection (FBP) reconstruction was regarded as the baseline. Both phantom and patient images were analyzed. A layer-adjustable anthropomorphic pelvis phantom capable of mimicking 38-58 cm lateral diameter-sized patients was imaged and reconstructed by the FBP and iDose4 algorithms with varying noise-reduction-levels, respectively. The resulting image sets were quantitatively assessed by two image quality indices, noise and contrast-to-noise ratio, and two clinical task-based indices, target CT Hounsfield number (for electron density determination) and structure contouring accuracy (for dose-volume calculations). Additionally, CT images of 34 patients reconstructed with iDose4 with six noise reduction levels were qualitatively evaluated by two radiation oncologists using a five-point scoring mechanism. For the phantom experiments, iDose4 achieved noise reduction up to 66.1% and CNR improvement up to 53.2%, compared to FBP without considering the changes of spatial resolution among images and the clinical acceptance of reconstructed images. Such improvements consistently appeared across different iDose4 noise reduction levels, exhibiting limited interlevel noise (< 5 HU) and target CT number variations (< 1 HU). The radiation dose required to achieve similar contouring accuracy decreased when using iDose4 in place of FBP, up to 32%. Contouring accuracy improvement for iDose4 images, when compared to FBP, was greater in larger patients than smaller-sized patients. Overall, the iDose4 algorithm provided superior radiation dose control while maintaining or improving task performance, when compared to FBP. The reader study on image quality improvement of patient cases shows that physicians preferred iDose4-reconstructed images on all cases compared to those from FBP algorithm with overall quality score: 1.21 vs. 3.15, p = 0.0022. However, qualitative evaluation strongly indicated that the radiation oncologists chose iDose4 noise reduction levels of 3-4 with additional consideration of task performance, instead of image quality metrics alone. Although higher iDose4 noise reduction levels improved the CNR through the further reduction of noise, there was pixelization of anatomical/tumor structures. Very-low-dose scans yielded severe photon starvation artifacts, which decreased target visualization on both FBP and iDose4 reconstructions, especially for the 58 cm phantom size. The iDose4 algorithm with a moderate noise reduction level is hence suggested for CT simulation and treatment planning. Quantitative task-based image quality metrics should be further investigated to accommodate additional clinical applications.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Análise e Desempenho de Tarefas , Tomografia Computadorizada por Raios X/métodos , Humanos , Doses de Radiação , Intensificação de Imagem Radiográfica , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/instrumentação
6.
Semin Radiat Oncol ; 34(1): 14-22, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38105089

RESUMO

MR-Guided Radiation Therapy (MRIgRT) has been made possible only due to the ingenuity and commitment of commercial radiation therapy system vendors. Unlike conventional linear accelerator systems, MRIgRT systems have had to overcome significant and previously untested techniques to integrate the MRI systems with the radiation therapy delivery systems. Each of these three commercial systems has developed different approaches to integrating their MR and Linac functions. Each has also decided on a different main magnetic field strength, from 0.35T to 1.5T, as well as different design philosophies for other systems, such as the patient support assembly and treatment planning workflow. This paper is intended to provide the reader with a detailed understanding of each system's configuration so that the reader can better interpret the scientific literature concerning these commercial MRIgRT systems.


Assuntos
Radioterapia Guiada por Imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Aceleradores de Partículas , Fluxo de Trabalho , Planejamento da Radioterapia Assistida por Computador
7.
Biomed Phys Eng Express ; 10(2)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38382110

RESUMO

Objective. In image-guided radiotherapy (IGRT), off-by-one vertebral body misalignments are rare but potentially catastrophic. In this study, a novel detection method for such misalignments in IGRT was investigated using densely-connected convolutional networks (DenseNets) for applications towards real-time error prevention and retrospective error auditing.Approach. A total of 4213 images acquired from 527 radiotherapy patients aligned with planar kV or MV radiographs were used to develop and test error-detection software modules. Digitally reconstructed radiographs (DRRs) and setup images were retrieved and co-registered according to the clinically applied alignment contained in the DICOM REG files. A semi-automated algorithm was developed to simulate patient positioning errors on the anterior-posterior (AP) and lateral (LAT) images shifted by one vertebral body. A DenseNet architecture was designed to classify either AP images individually or AP and LAT image pairs. Receiver-operator characteristic curves (ROC) and areas under the curves (AUC) were computed to evaluate the classifiers on test subsets. Subsequently, the algorithm was applied to the entire dataset in order to retrospectively determine the absolute off-by-one vertebral body error rate for planar radiograph guided RT at our institution from 2011-2021.Main results. The AUCs for the kV models were 0.98 for unpaired AP and 0.99 for paired AP-LAT. The AUC for the MV AP model was 0.92. For a specificity of 95%, the paired kV model achieved a sensitivity of 99%. Application of the model to the entire dataset yielded a per-fraction off-by-one vertebral body error rate of 0.044% [0.0022%, 0.21%] for paired kV IGRT including one previously unreported error.Significance. Our error detection algorithm was successful in classifying vertebral body positioning errors with sufficient accuracy for retrospective quality control and real-time error prevention. The reported positioning error rate for planar radiograph IGRT is unique in being determined independently of an error reporting system.


Assuntos
Radioterapia Guiada por Imagem , Corpo Vertebral , Humanos , Estudos Retrospectivos , Radiografia , Radioterapia Guiada por Imagem/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
8.
Artigo em Inglês | MEDLINE | ID: mdl-38485098

RESUMO

PURPOSE: Present knowledge of patient setup and alignment errors in image guided radiation therapy (IGRT) relies on voluntary reporting, which is thought to underestimate error frequencies. A manual retrospective patient-setup misalignment error search is infeasible owing to the bulk of cases to be reviewed. We applied a deep learning-based misalignment error detection algorithm (EDA) to perform a fully automated retrospective error search of clinical IGRT databases and determine an absolute gross patient misalignment error rate. METHODS AND MATERIALS: The EDA was developed to analyze the registration between planning scans and pretreatment cone beam computed tomography scans, outputting a misalignment score ranging from 0 (most unlikely) to 1 (most likely). The algorithm was trained using simulated translational errors on a data set obtained from 680 patients treated at 2 radiation therapy clinics between 2017 and 2022. A receiver operating characteristic analysis was performed to obtain target thresholds. DICOM Query and Retrieval software was integrated with the EDA to interact with the clinical database and fully automate data retrieval and analysis during a retrospective error search from 2016 to 2017 and from 2021 to 2022 for the 2 institutions, respectively. Registrations were flagged for human review using both a hard-thresholding method and a prediction trending analysis over each individual patient's treatment course. Flagged registrations were manually reviewed and categorized as errors (>1 cm misalignment at the target) or nonerrors. RESULTS: A total of 17,612 registrations were analyzed by the EDA, resulting in 7.7% flagged events. Three previously reported errors were successfully flagged by the EDA, and 4 previously unreported vertebral body misalignment errors were discovered during case reviews. False positive cases often displayed substantial image artifacts, patient rotation, and soft tissue anatomy changes. CONCLUSIONS: Our results validated the clinical utility of the EDA for bulk image reviews and highlighted the reliability and safety of IGRT, with an absolute gross patient misalignment error rate of 0.04% ± 0.02% per delivered fraction.

9.
Int J Radiat Oncol Biol Phys ; 118(5): 1181-1191, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38160916

RESUMO

PURPOSE: Real-time intrafraction tracking/gating is an integral component of magnetic resonance imaging-guided radiation therapy (MRgRT) and may have contributed to the acute toxicity reduction during prostate stereotactic body radiation therapy observed on the MRgRT-arm of the MIRAGE (MAGNETIC RESONANCE IMAGING-GUIDED Stereotactic Body Radiotherapy for Prostate Cancer) randomized trial (NCT04384770). Herein we characterized intrafraction prostate motion and assessed gating effectiveness. METHODS AND MATERIALS: Seventy-nine patients were treated on an MR-LINAC. Real-time cine imaging was acquired at 4Hz in a sagittal plane. If >10% of the prostate area moved outside of a 3-mm gating boundary, an automatic beam hold was initiated. An in-house tool was developed to retrospectively extract gating signal for all patients and identify the tracked prostate in each cine frame for a subgroup of 40 patients. The fraction of time the prostate was within the gating window was defined as the gating duty cycle (GDC). RESULTS: A total of 391 treatments from 79 patients were analyzed. Median GDC was 0.974 (IQR, 0.916-0.983). Fifty (63.2%) and 24 (30.4%) patients had at least 1 fraction with GDC ≤0.9 and GDC ≤0.8, respectively. Incidence of low GDC fractions among patients appeared stochastic. Patients with minimum GDC <0.8 trended toward more frequent grade 2 genitourinary toxicity compared with those with minimum GDC >0.8 (38% vs 18%, P = .065). Prostate intrafraction motion was mostly along the bladder-rectum axis and predominantly in the superior-anterior direction. Motion in the inferior-posterior direction was associated with significantly higher rate of acute grade 2 genitourinary toxicity (66.7% vs 13.9%, P = .001). Gating limited mean prostate motion during treatment delivery in fractions with a GDC <0.9 (<0.8) to 2.9 mm (2.9 mm) versus 4.1 mm (4.7 mm) for ungated motion. CONCLUSIONS: Fractions with large intrafraction motion were associated with increased toxicity and their occurrence among patients appears stochastic. Real-time tracking/gating effectively mitigated this motion and is likely a major contributing factor of acute toxicity reduction associated with MRgRT.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Masculino , Humanos , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Estudos Retrospectivos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/patologia , Imageamento por Ressonância Magnética/métodos
10.
Phys Imaging Radiat Oncol ; 30: 100573, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38585371

RESUMO

Background and purpose: Magnetic Resonance Imaging (MRI)-guided Stereotactic body radiotherapy (SBRT) treatment to prostate bed after radical prostatectomy has garnered growing interests. The aim of this study is to evaluate intra-fractional anatomic and dose/volume metric variations for patients receiving this treatment. Materials and methods: Nineteen patients who received 30-34 Gy in 5 fractions on a 0.35T MR-Linac were included. Pre- and post-treatment MRIs were acquired for each fraction (total of 75 fractions). The Clinical Target Volume (CTV), bladder, rectum, and rectal wall were contoured on all images. Volumetric changes, Hausdorff distance, Mean Distance to Agreement (MDA), and Dice similarity coefficient (DSC) for each structure were calculated. Median value and Interquartile range (IQR) were recorded. Changes in target coverage and Organ at Risk (OAR) constraints were compared and evaluated using Wilcoxon rank sum tests at a significant level of 0.05. Results: Bladder had the largest volumetric changes, with a median volume increase of 48.9 % (IQR 28.9-76.8 %) and a median MDA of 5.1 mm (IQR 3.4-7.1 mm). Intra-fractional CTV volume remained stable with a median volume change of 1.2 % (0.0-4.8 %). DSC was 0.97 (IQR 0.94-0.99). For the dose/volume metrics, there were no statistically significant changes observed except for an increase in bladder hotspot and a decrease of bladder V32.5 Gy and mean dose. The CTV V95% changed from 99.9 % (IQR 98.8-100 %) to 99.6 % (IQR 93.9-100 %). Conclusion: Despite intra-fractional variations of OARs, CTV coverage remained stable during MRI-guided SBRT treatments for the prostate bed.

11.
Int J Radiat Oncol Biol Phys ; 118(4): 986-997, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-37871887

RESUMO

PURPOSE: Emerging data suggest that trigone dosimetry may be more associated with poststereotactic body radiation therapy (SBRT) urinary toxicity than whole bladder dosimetry. We quantify the dosimetric effect of interfractional displacement and deformation of the whole bladder and trigone during prostate SBRT using on-board, pretreatment 0.35T magnetic resonance images (MRI). METHODS AND MATERIALS: Seventy-seven patients treated with MRI-guided prostate SBRT (40 Gy/5 fractions) on the MRI arm of a phase 3 single-center randomized trial were included. Bladder and trigone structures were contoured on images obtained from a 0.35T simulation MRI and 5 on-board pretreatment MRIs. Dice similarity coefficient (DSC) scores and changes in volume between simulation and daily treatments were calculated. Dosimetric parameters including Dmax, D0.03 cc, Dmean, V40 Gy, V39 Gy, V38 Gy, and V20 Gy for the bladder and trigone for the simulation and daily treatments were collected. Both physician-scored (Common Terminology Criteria for Adverse Events, version 4.03 scale) as well as patient-reported (International Prostate Symptom Scores and the Expanded Prostate Cancer Index Composite-26 scores) acute genitourinary (GU) toxicity outcomes were collected and analyzed. RESULTS: The average treatment bladder volume was about 30% smaller than the simulation bladder volume; however, the trigone volume remained fairly consistent despite being positively correlated with total bladder volume. Overall, the trigone accounted for <2% of the bladder volume. Median DSC for the bladder was 0.79, whereas the median DSC of the trigone was only 0.33. No statistically significant associations between our selected bladder and trigonal dosimetric parameters and grade ≥2 GU toxicity were identified, although numerically, patients with GU toxicity (grade ≥2) had higher intermediate doses to the bladder (V20 Gy and Dmean) and larger volumes exposed to higher doses in the trigone (V40 Gy, V39 Gy, and V38 Gy). CONCLUSIONS: The trigone exhibits little volume change, but considerable interfractional displacement/deformation. As a result, the relative volume of the trigone receiving high doses during prostate SBRT varies substantially between fractions, which could influence GU toxicity and may not be predicted by radiation planning dosimetry.


Assuntos
Neoplasias da Próstata , Exposição à Radiação , Radiocirurgia , Masculino , Humanos , Bexiga Urinária/efeitos da radiação , Próstata/diagnóstico por imagem , Próstata/patologia , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia
12.
Phys Med Biol ; 69(7)2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38452385

RESUMO

Objective. To combat the motion artifacts present in traditional 4D-CBCT reconstruction, an iterative technique known as the motion-compensated simultaneous algebraic reconstruction technique (MC-SART) was previously developed. MC-SART employs a 4D-CBCT reconstruction to obtain an initial model, which suffers from a lack of sufficient projections in each bin. The purpose of this study is to demonstrate the feasibility of introducing a motion model acquired during CT simulation to MC-SART, coined model-based CBCT (MB-CBCT).Approach. For each of 5 patients, we acquired 5DCTs during simulation and pre-treatment CBCTs with a simultaneous breathing surrogate. We cross-calibrated the 5DCT and CBCT breathing waveforms by matching the diaphragms and employed the 5DCT motion model parameters for MC-SART. We introduced the Amplitude Reassignment Motion Modeling technique, which measures the ability of the model to control diaphragm sharpness by reassigning projection amplitudes with varying resolution. We evaluated the sharpness of tumors and compared them between MB-CBCT and 4D-CBCT. We quantified sharpness by fitting an error function across anatomical boundaries. Furthermore, we compared our MB-CBCT approach to the traditional MC-SART approach. We evaluated MB-CBCT's robustness over time by reconstructing multiple fractions for each patient and measuring consistency in tumor centroid locations between 4D-CBCT and MB-CBCT.Main results. We found that the diaphragm sharpness rose consistently with increasing amplitude resolution for 4/5 patients. We observed consistently high image quality across multiple fractions, and observed stable tumor centroids with an average 0.74 ± 0.31 mm difference between the 4D-CBCT and MB-CBCT. Overall, vast improvements over 3D-CBCT and 4D-CBCT were demonstrated by our MB-CBCT technique in terms of both diaphragm sharpness and overall image quality.Significance. This work is an important extension of the MC-SART technique. We demonstrated the ability ofa priori5DCT models to provide motion compensation for CBCT reconstruction. We showed improvements in image quality over both 4D-CBCT and the traditional MC-SART approach.


Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares , Humanos , Projetos Piloto , Tomografia Computadorizada Quadridimensional/métodos , Processamento de Imagem Assistida por Computador/métodos , Movimento (Física) , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Imagens de Fantasmas , Algoritmos
13.
JAMA Oncol ; 10(3): 352-359, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38206614

RESUMO

Importance: Intrathoracic progression remains the predominant pattern of failure in patients treated with concurrent chemoradiation followed by a consolidation immune checkpoint inhibitor for locally advanced, unresectable non-small cell lung cancer (NSCLC). Objective: To determine the maximum tolerated dose (MTD) and use of hypofractionated concurrent chemoradiation with an adaptive stereotactic ablative radiotherapy (SABR) boost. Design, Setting, and Participants: This was an early-phase, single-institution, radiation dose-escalation nonrandomized controlled trial with concurrent chemotherapy among patients with clinical stage II (inoperable/patient refusal of surgery) or III NSCLC (American Joint Committee on Cancer Staging Manual, seventh edition). Patients were enrolled and treated from May 2011 to May 2018, with a median patient follow-up of 18.2 months. Patients advanced to a higher SABR boost dose if dose-limiting toxic effects (any grade 3 or higher pulmonary, gastrointestinal, or cardiac toxic effects, or any nonhematologic grade 4 or higher toxic effects) occurred in fewer than 33% of the boost cohort within 90 days of follow-up. The current analyses were conducted from January to September 2023. Intervention: All patients first received 4 Gy × 10 fractions followed by an adaptive SABR boost to residual metabolically active disease, consisting of an additional 25 Gy (low, 5 Gy × 5 fractions), 30 Gy (intermediate, 6 Gy × 5 fractions), or 35 Gy (high, 7 Gy × 5 fractions) with concurrent weekly carboplatin/paclitaxel. Main Outcome and Measure: The primary outcome was to determine the MTD. Results: Data from 28 patients (median [range] age, 70 [51-88] years; 16 [57%] male; 24 [86%] with stage III disease) enrolled across the low- (n = 10), intermediate- (n = 9), and high- (n = 9) dose cohorts were evaluated. The protocol-specified MTD was not exceeded. The incidences of nonhematologic acute and late (>90 days) grade 3 or higher toxic effects were 11% and 7%, respectively. No grade 3 toxic effects were observed in the intermediate-dose boost cohort. Two deaths occurred in the high-dose cohort. Two-year local control was 74.1%, 85.7%, and 100.0% for the low-, intermediate-, and high-dose cohorts, respectively. Two-year overall survival was 30.0%, 76.2%, and 55.6% for the low-, intermediate-, and high-dose cohorts, respectively. Conclusions and Relevance: This early-phase, dose-escalation nonrandomized controlled trial showed that concurrent chemoradiation with an adaptive SABR boost to 70 Gy in 15 fractions with concurrent chemotherapy is a safe and effective regimen for patients with locally advanced, unresectable NSCLC. Trial Registration: ClinicalTrials.gov Identifier: NCT01345851.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radiocirurgia , Humanos , Masculino , Idoso , Feminino , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Neoplasias Pulmonares/tratamento farmacológico , Radiocirurgia/efeitos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Fracionamento da Dose de Radiação
14.
Radiother Oncol ; 191: 110064, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38135187

RESUMO

BACKGROUND AND PURPOSE: Radiation dose escalation may improve local control (LC) and overall survival (OS) in select pancreatic ductal adenocarcinoma (PDAC) patients. We prospectively evaluated the safety and efficacy of ablative stereotactic magnetic resonance (MR)-guided adaptive radiation therapy (SMART) for borderline resectable (BRPC) and locally advanced pancreas cancer (LAPC). The primary endpoint of acute grade ≥ 3 gastrointestinal (GI) toxicity definitely related to SMART was previously published with median follow-up (FU) 8.8 months from SMART. We now present more mature outcomes including OS and late toxicity. MATERIALS AND METHODS: This prospective, multi-center, single-arm open-label phase 2 trial (NCT03621644) enrolled 136 patients (LAPC 56.6 %; BRPC 43.4 %) after ≥ 3 months of any chemotherapy without distant progression and CA19-9 ≤ 500 U/mL. SMART was delivered on a 0.35 T MR-guided system prescribed to 50 Gy in 5 fractions (biologically effective dose10 [BED10] = 100 Gy). Elective coverage was optional. Surgery and chemotherapy were permitted after SMART. RESULTS: Mean age was 65.7 years (range, 36-85), induction FOLFIRINOX was common (81.7 %), most received elective coverage (57.4 %), and 34.6 % had surgery after SMART. Median FU was 22.9 months from diagnosis and 14.2 months from SMART, respectively. 2-year OS from diagnosis and SMART were 53.6 % and 40.5 %, respectively. Late grade ≥ 3 toxicity definitely, probably, or possibly attributed to SMART were observed in 0 %, 4.6 %, and 11.5 % patients, respectively. CONCLUSIONS: Long-term outcomes from the phase 2 SMART trial demonstrate encouraging OS and limited severe toxicity. Additional prospective evaluation of this novel strategy is warranted.


Assuntos
Neoplasias Pancreáticas , Radiocirurgia , Humanos , Idoso , Neoplasias Pancreáticas/patologia , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Planejamento da Radioterapia Assistida por Computador , Radiocirurgia/efeitos adversos
15.
J Appl Clin Med Phys ; 14(1): 3949, 2013 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-23318382

RESUMO

One of the most important aspects of quality assurance (QA) in radiation therapy is redundancy of patient treatment dose calculation. This work is focused on the patient-specific time and 3D dose treatment plan verification for stereotactic radiosurgery using Leksell Gamma Knife Perfexion (LGK PFX). The virtual model of LGK PFX was developed in MATLAB, based on the physical dimensions provided by the manufacturer. The ring-specific linear attenuation coefficients (LAC) and output factors (OFs) reported by the manufacturer were replaced by the measurement-based collimator size-specific OFs and a single LAC = 0.0065 mm-1. Calculation depths for each LGK PFX shot were obtained by ray-tracing technique, and the dose calculation formalism was similar to the one used by GammaPlan treatment planning software versions 8 and 9. The architecture of the QA process was based on the in-house online database search of the LGK PFX database search for plan-specific information. A series of QA phantom plans was examined to verify geometric and dosimetric accuracy of the software. The accuracy of the QA process was further evaluated through evaluation of a series of patient plans. The shot time/focus point dose verification for each shot took less than 1 sec/shot with full 3D isodose verification taking about 30 sec/shot on a desktop PC. GammaPlan database access time took less than 0.05 sec. The geometric accuracy (location of the point of maximum dose) of the phantom and patient plan was dependent on the resolution of the original dose matrix and was of the order of 1 dose element. Dosimetric accuracy of the independently calculated phantom and patient point (focus) doses was within 3.5% from the GammaPlan, with the mean = 2.3% and SD= 1.1%. The process for independent pretreatment patient-specific Gamma Knife Perfexion time and dose verification was created and validated.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde/métodos , Radiocirurgia/instrumentação , Radiocirurgia/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Assistência Centrada no Paciente/normas , Radiocirurgia/métodos , Dosagem Radioterapêutica , Estados Unidos
16.
Pract Radiat Oncol ; 2023 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-38043644

RESUMO

PURPOSE: Recently, a randomized trial demonstrated that a hyaluronic acid (HA) spacer placed before prostate hypofractionated intensity modulated radiation therapy improved rectal dosimetry and reduced acute grade 2+ gastrointestinal toxicity. However, 26.5% of patients receiving the spacer experienced a minimal clinically important decline (MCID) in bowel quality-of-life (QOL). The purpose of this study is to evaluate whether certain characteristics of the rectal spacer, as determined on postimplant imaging, were associated with change in bowel QOL at 3-months. METHODS AND MATERIALS: This is a secondary analysis of the 136 patients who received the HA spacer on the randomized trial. Postimplant spacer characteristics (ie, prostate-rectum spacing at superior/midgland/inferior/apex planes, symmetry, prostate volume, spacer volume) were systematically analyzed from structure sets using custom software code. Characteristics demonstrating significant associations with rectal V30 on multivariate linear regression were identified. Linear regression models were used to analyze the associations of such characteristics with change (baseline to 3 months) in both bowel and urinary QOL. RESULTS: Apical spacing (mean 9.4 (standard deviation 4.0)) was significantly smaller than spacing measurements at more superior planes. 95.6% of patients had a symmetrical implant. Apical spacing (P < .001) and prostate volume (P = .01) were significantly associated with rectal V30 on multivariate analysis. However, only apical spacing (0.38/mm; P = .01) was associated with change in bowel QOL, even with adjustment of baseline bowel score (-0.33; P < .01). Percentages of patients with bowel MCID were 14.8% for >= 10 mm versus 36.6% for <10 mm apical spacing (P = .01). Apical spacing was not associated with change in urinary QOL (-0.09; P = .72), when adjusted for baseline urinary QOL (-0.52; P < .01). CONCLUSION: Greater apical spacing was associated with improved rectal dosimetry and smaller decline in bowel QOL at 3-months. Further prospective data are needed to fully understand the ramifications of increased apical spacing.

17.
Front Med (Lausanne) ; 10: 1151867, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37840998

RESUMO

Purpose: Recent advancements in obtaining image-based biomarkers from CT images have enabled lung function characterization, which could aid in lung interventional planning. However, the regional heterogeneity in these biomarkers has not been well documented, yet it is critical to several procedures for lung cancer and COPD. The purpose of this paper is to analyze the interlobar and intralobar heterogeneity of tissue elasticity and study their relationship with COPD severity. Methods: We retrospectively analyzed a set of 23 lung cancer patients for this study, 14 of whom had COPD. For each patient, we employed a 5DCT scanning protocol to obtain end-exhalation and end-inhalation images and semi-automatically segmented the lobes. We calculated tissue elasticity using a biomechanical property estimation model. To obtain a measure of lobar elasticity, we calculated the mean of the voxel-wise elasticity values within each lobe. To analyze interlobar heterogeneity, we defined an index that represented the properties of the least elastic lobe as compared to the rest of the lobes, termed the Elasticity Heterogeneity Index (EHI). An index of 0 indicated total homogeneity, and higher indices indicated higher heterogeneity. Additionally, we measured intralobar heterogeneity by calculating the coefficient of variation of elasticity within each lobe. Results: The mean EHI was 0.223 ± 0.183. The mean coefficient of variation of the elasticity distributions was 51.1% ± 16.6%. For mild COPD patients, the interlobar heterogeneity was low compared to the other categories. For moderate-to-severe COPD patients, the interlobar and intralobar heterogeneities were highest, showing significant differences from the other groups. Conclusion: We observed a high level of lung tissue heterogeneity to occur between and within the lobes in all COPD severity cases, especially in moderate-to-severe cases. Heterogeneity results demonstrate the value of a regional, function-guided approach like elasticity for procedures such as surgical decision making and treatment planning.

18.
Radiother Oncol ; 183: 109631, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36934894

RESUMO

BACKGROUND AND PURPOSE: We examined the interfractional variations of clinical target volumes (CTVs), planning target volumes (PTVs), and organs-at-risk (OARs) in patients receiving MRI-guided stereotactic body radiotherapy (SBRT) to the prostate bed and evaluated the potential role of adaptive planning. MATERIALS AND METHODS: 31 patients received 30-34 Gy in five fractions to the prostate bed on a phase II clinical trial. OARs, CTVs, and PTVs were retrospectively contoured on daily pretreatment MRIs (n = 155). Geometric comparisons were made between initial planning contours and daily pretreatment contours. Predicted treatment plans for each fraction were evaluated using the following constraints: CTV V95%>93%, PTV V95%>90%, bladder Dmax < 36.7 Gy, bladder V32.5 Gy < 35%, rectum Dmax < 36.7 Gy, rectum V27.5 Gy < 45%, rectum 32.5 Gy < 30%, and rectal wall V24Gy < 50%. Adaptive planning was simulated for all fractions that failed to meet these criteria. Plans were then re-evaluated. RESULTS: Median change in volume was 0.48% for CTV, -24.5% for bladder, and 6.95% for rectum. Median DSC was 0.89 for CTV, 0.79 for bladder, and 0.76 for rectum. 145/155 fractions (93.5%) met CTV V95%>93%. 75/155 fractions (48.4%) failed at least one OAR dose constraint. Overall, 83/155 fractions (53.5%) met criteria for adapting planning. This affected 24/31 patients (77.4%). Following adaptive planning, all fractions met CTV V95%>93% and PTV V95%>90% and 120/155 fractions (77.4%) met all OAR constraints. CONCLUSION: Due to significant interfractional variations in anatomy, a majority of fractions failed to meet both target volume and OAR constraints. However, adaptive planning was effective in overcoming these anatomic changes. Adaptive planning should be routinely considered in prostate bed SBRT.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Masculino , Humanos , Próstata , Estudos Retrospectivos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Prostatectomia , Imageamento por Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Órgãos em Risco
19.
Med Phys ; 50(5): 2662-2671, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36908243

RESUMO

BACKGROUND: Misalignment to the incorrect vertebral body remains a rare but serious patient safety risk in image-guided radiotherapy (IGRT). PURPOSE: Our group has proposed that an automated image-review algorithm be inserted into the IGRT process as an interlock to detect off-by-one vertebral body errors. This study presents the development and multi-institutional validation of a convolutional neural network (CNN)-based approach for such an algorithm using patient image data from a planar stereoscopic x-ray IGRT system. METHODS: X-rays and digitally reconstructed radiographs (DRRs) were collected from 429 spine radiotherapy patients (1592 treatment fractions) treated at six institutions using a stereoscopic x-ray image guidance system. Clinically-applied, physician approved, alignments were used for true-negative, "no-error" cases. "Off-by-one vertebral body" errors were simulated by translating DRRs along the spinal column using a semi-automated method. A leave-one-institution-out approach was used to estimate model accuracy on data from unseen institutions as follows: All of the images from five of the institutions were used to train a CNN model from scratch using a fixed network architecture and hyper-parameters. The size of this training set ranged from 5700 to 9372 images, depending on exactly which five institutions were contributing data. The training set was randomized and split using a 75/25 split into the final training/ validation sets. X-ray/ DRR image pairs and the associated binary labels of "no-error" or "shift" were used as the model input. Model accuracy was evaluated using images from the sixth institution, which were left out of the training phase entirely. This test set ranged from 180 to 3852 images, again depending on which institution had been left out of the training phase. The trained model was used to classify the images from the test set as either "no-error" or "shifted", and the model predictions were compared to the ground truth labels to assess the model accuracy. This process was repeated until each institution's images had been used as the testing dataset. RESULTS: When the six models were used to classify unseen image pairs from the institution left out during training, the resulting receiver operating characteristic area under the curve values ranged from 0.976 to 0.998. With the specificity fixed at 99%, the corresponding sensitivities ranged from 61.9% to 99.2% (mean: 77.6%). With the specificity fixed at 95%, sensitivities ranged from 85.5% to 99.8% (mean: 92.9%). CONCLUSION: This study demonstrated the CNN-based vertebral body misalignment model is robust when applied to previously unseen test data from an outside institution, indicating that this proposed additional safeguard against misalignment is feasible.


Assuntos
Aprendizado Profundo , Humanos , Raios X , Corpo Vertebral , Estudos Retrospectivos , Redes Neurais de Computação
20.
JAMA Oncol ; 9(3): 365-373, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36633877

RESUMO

Importance: Magnetic resonance imaging (MRI) guidance offers multiple theoretical advantages in the context of stereotactic body radiotherapy (SBRT) for prostate cancer. However, to our knowledge, these advantages have yet to be demonstrated in a randomized clinical trial. Objective: To determine whether aggressive margin reduction with MRI guidance significantly reduces acute grade 2 or greater genitourinary (GU) toxic effects after prostate SBRT compared with computed tomography (CT) guidance. Design, Setting, and Participants: This phase 3 randomized clinical trial (MRI-Guided Stereotactic Body Radiotherapy for Prostate Cancer [MIRAGE]) enrolled men aged 18 years or older who were receiving SBRT for clinically localized prostate adenocarcinoma at a single center between May 5, 2020, and October 1, 2021. Data were analyzed from January 15, 2021, through May 15, 2022. All patients had 3 months or more of follow-up. Interventions: Patients were randomized 1:1 to SBRT with CT guidance (control arm) or MRI guidance. Planning margins of 4 mm (CT arm) and 2 mm (MRI arm) were used to deliver 40 Gy in 5 fractions. Main Outcomes and Measures: The primary end point was the incidence of acute (≤90 days after SBRT) grade 2 or greater GU toxic effects (using Common Terminology Criteria for Adverse Events, version 4.03 [CTCAE v4.03]). Secondary outcomes included CTCAE v4.03-based gastrointestinal toxic effects and International Prostate Symptom Score (IPSS)-based and Expanded Prostate Cancer Index Composite-26 (EPIC-26)-based outcomes. Results: Between May 2020 and October 2021, 156 patients were randomized: 77 to CT (median age, 71 years [IQR, 67-77 years]) and 79 to MRI (median age, 71 years [IQR, 68-75 years]). A prespecified interim futility analysis conducted after 100 patients reached 90 or more days after SBRT was performed October 1, 2021, with the sample size reestimated to 154 patients. Thus, the trial was closed to accrual early. The incidence of acute grade 2 or greater GU toxic effects was significantly lower with MRI vs CT guidance (24.4% [95% CI, 15.4%-35.4%] vs 43.4% [95% CI, 32.1%-55.3%]; P = .01), as was the incidence of acute grade 2 or greater gastrointestinal toxic effects (0.0% [95% CI, 0.0%-4.6%] vs 10.5% [95% CI, 4.7%-19.7%]; P = .003). Magnetic resonance imaging guidance was associated with a significantly smaller percentage of patients with a 15-point or greater increase in IPSS at 1 month (6.8% [5 of 72] vs 19.4% [14 of 74]; P = .01) and a significantly reduced percentage of patients with a clinically significant (≥12-point) decrease in EPIC-26 bowel scores (25.0% [17 of 68] vs 50.0% [34 of 68]; P = .001) at 1 month. Conclusions and Relevance: In this randomized clinical trial, compared with CT-guidance, MRI-guided SBRT significantly reduced both moderate acute physician-scored toxic effects and decrements in patient-reported quality of life. Longer-term follow-up will confirm whether these notable benefits persist. Trial Registration: ClinicalTrials.gov Identifier: NCT04384770.


Assuntos
Ilusões Ópticas , Neoplasias da Próstata , Radiocirurgia , Masculino , Humanos , Idoso , Próstata/patologia , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Qualidade de Vida , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA