Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Arthroplasty ; 39(2): 336-342, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37586596

RESUMO

BACKGROUND: The Coronal Plane Alignment of the Knee (CPAK) classification categorizes knee phenotypes based on constitutional limb alignment (arithmetic hip-knee-ankle angle or aHKA) and joint line obliquity (JLO). This study aimed to determine if sagittal and rotational knee alignments vary among CPAK types in order to establish whether this classification should be expanded beyond coronal plane assessment. METHODS: Coronal, sagittal, and rotational alignment measurements were made and CPAK types were calculated from computed tomographic data of 437 patients (509 knees) who underwent robotic-assisted total knee arthroplasty (TKA). Differences in femoral, tibial, and tibio-femoral angular measurements were compared across CPAK types, and correlations were made to aHKA and JLO. Nonparametric and linear regression tests were used to analyze between-type differences. RESULTS: There were no differences in tibial slope or femoral rotational measures across CPAK phenotypes. However, CPAK Type III knees had a greater tibio-femoral rotation mean difference than CPAK Type I, II, IV, and V knees (P < .05). We also found increased femoral flexion in Type I knees when compared to Type VI knees (P = .01). The aHKA had a weak correlation with femoral flexion angle, and JLO had a weak correlation with femoral posterior condylar axis to tibial antero-posterior axis angle. CONCLUSION: Few clinically important differences in sagittal and rotational alignments were found between CPAK types, indicating that CPAK phenotype has little correlation to 3-dimensional alignment characteristics. Need for an expansion of the CPAK classification beyond coronal plane alignment is not supported from these results.


Assuntos
Artroplastia do Joelho , Fraturas Ósseas , Osteoartrite do Joelho , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Joelho/cirurgia , Artroplastia do Joelho/métodos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Fraturas Ósseas/cirurgia , Estudos Retrospectivos
2.
Knee Surg Sports Traumatol Arthrosc ; 31(11): 4755-4765, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37490128

RESUMO

PURPOSE: The purpose of this study was to understand if differences exist between computed tomography (CT) and long leg radiographs (LLR) when defining coronal plane alignment of the lower limb in total knee arthroplasty (TKA). It aimed to identify any such differences between the two imaging modalities by quantifying constitutional limb alignment (arithmetic hip-knee-ankle angle (aHKA), joint line obliquity (JLO) and Coronal Plane Alignment of the Knee (CPAK) type within the same population. METHODS: A retrospective radiographic study compared pre-operative LLR and CT measurements in patients undergoing robotic-assisted TKA. The aHKA, JLO and CPAK types were calculated after measuring the medial proximal tibial angle (MPTA) and lateral distal femoral angle (LDFA). The primary outcomes were the mean differences in aHKA (MPTA-LDFA), JLO (MPTA + LDFA) and proportions of CPAK types between LLR and CT groups. The secondary outcomes were the differences in CT-derived MPTA values based on four different tibial sagittal landmarks. RESULTS: After exclusions, 465 imaging sets were analysed in 394 patients. There was a statistically significant mean difference between LLR and CT, respectively, for both MPTA (87.5° vs. 86.2°; p < 0.01) and LDFA (88.7° vs. 87.3°; p < 0.01). There were also statistically significant differences for aHKA (- 0.2° vs. - 1.1°) and JLO (175.1° vs. 173.4°) for LLR and CT, respectively (both p < 0.01). CT increased the proportion of patients with CPAK Type I (constitutional varus aHKA, apex distal JLO) and CPAK Type II (neutral aHKA, apex distal JLO), and decreased numbers of CPAK Types III-VI. There were significant mean differences in the MPTA using varying sagittal landmarks. CONCLUSION: Alignment determined by LLRs underestimates the magnitude of both constitutional varus alignment and joint line obliquity compared to CT, differences that notably increase the proportions of patients included in CPAK Types I and II. These distinctions are primarily due to underestimation of proximal tibial varus when measured on LLRs compared to CT, which more specifically defines articular weight-bearing points. LEVEL OF EVIDENCE: III.

3.
Knee Surg Sports Traumatol Arthrosc ; 31(11): 5118-5127, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37789215

RESUMO

PURPOSE: Key concepts in total knee arthroplasty include restoration of limb alignment and soft-tissue balance. Although differences in balance have been reported amongst mechanical alignment (MA), kinematic alignment (KA) and functional alignment (FA) techniques, it remains unclear whether there are differences in gap imbalance or resection thicknesses when comparing different constitutional alignment subgroups. METHODS: MA (measured resection technique), KA (matched resections technique) and FA (technique based on the restricted KA boundaries) were compared in 116 consecutive patients undergoing 137 robotic-assisted cruciate-retaining total knee arthroplasties. The primary outcome was the proportion of balanced gaps (differential laxities ≤ 2 mm) for extension, flexion, medial and lateral gap measurements. Manual pre-resection laxity measurements were obtained for MA and KA and manual post-resection measurements were obtained for FA in 10° and in 90° of knee flexion. Secondary outcomes were resection depths and implant alignment. All outcomes were analysed per constitutional coronal alignment and joint line obliquity subgroups. RESULTS: The proportions of balance in all four gap measurements were 54.7%, 66.4% and 96.5%, with MA, KA and FA, respectively. Across all constitutional alignment types, FA achieved the highest proportion of balance. MA resected the least amount of bone from the medial tibial plateau. KA had femoral components in most valgus and most internally rotated, tibial components in most varus and was the most bone-preserving for the posteromedial femoral condyle. FA had the most externally rotated femoral components and was most bone-preserving for the distal femoral resections. CONCLUSION: The study shows that implant alignment to the mechanical axis or joint line anatomy (equal resections) alone does not guarantee a balanced total knee arthroplasty. FA resulted in the highest proportion of balanced knees across all analysed subgroups. Future research will consider whether one alignment philosophy leads to superior outcomes for different constitutional alignment subgroups. LEVEL OF EVIDENCE: Level II.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Articulação do Joelho/cirurgia , Joelho/cirurgia , Tíbia/cirurgia , Osteoartrite do Joelho/cirurgia
4.
J Arthroplasty ; 38(9): 1892-1899.e1, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36963533

RESUMO

BACKGROUND: The extent of geographic variation in knee phenotypes remains unclear. The Coronal Plane Alignment of the Knee (CPAK) Classification proposes 9 coronal plane phenotypes based on constitutional limb alignment and joint line obliquity. This systematic review aims to examine differences in the distributions of CPAK types across geographic regions. METHODS: A systematic review of the literature was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Studies reporting distributions of knee phenotypes according to the CPAK classification for healthy and/or arthritic knees were included. RESULTS: There were 7 studies included, accounting for 5,964 knees in 3,917 subjects. Among healthy knees (n = 1,214), CPAK type II was the most common type in Belgium (39.2%), Taiwan (39.3%), and India (25.6%). Among arthritic knees (n = 2,804), CPAK type I was the most common in France (33.4%), India (58.8%), and Japan (53.8%), whereas CPAK type II was the most common in Australia (32.8%). The proportion of CPAK type I and II knees varied significantly across geographic regions among healthy (P < .01) and arthritic knees (P < .01). CONCLUSION: Significant variation in CPAK distributions exists between countries. Further work is needed to delineate racial and sexual differences in CPAK types, which were not explored in this article. A better understanding of population-level variability in knee phenotypes may enable orthopaedic surgeons to offer a more personalized approach to knee arthroplasty.


Assuntos
Osteoartrite do Joelho , Tíbia , Humanos , Tíbia/cirurgia , Fêmur , Fenômenos Biomecânicos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Fenótipo , Estudos Retrospectivos
5.
Knee Surg Sports Traumatol Arthrosc ; 30(9): 2980-2990, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35819463

RESUMO

PURPOSE: Kinematically aligned total knee arthroplasty (KA TKA) relies on precise determination of constitutional alignment to set resection targets. The arithmetic hip-knee-ankle angle (aHKA) is a radiographic method to estimate constitutional alignment following onset of arthritis. Intraoperatively, constitutional alignment may also be approximated using navigation-based angular measurements of deformity correction, termed the stressed HKA (sHKA). This study aimed to investigate the relationship between these methods of estimating constitutional alignment to better understand their utility in KA TKA. METHODS: A radiological and intraoperative computer-assisted navigation study was undertaken comparing measurements of the aHKA using radiographs and computed tomography (CT-aHKA) to the sHKA in 88 TKAs meeting the inclusion criteria. The primary outcome was the difference in the paired means between the three methods to determine constitutional alignment (aHKA, CT-aHKA, sHKA). Secondary outcomes included testing agreement across measurements using Bland-Altman plots and analysis of subgroup differences based on different patterns of compartmental arthritis. RESULTS: There were no statistically significant differences between any paired comparison or across groups (aHKA vs. sHKA: 0.1°, p = 0.817; aHKA vs. CT-aHKA: 0.3°, p = 0.643; CT-aHKA vs. sHKA: 0.2°, p = 0.722; ANOVA, p = 0.845). Bland-Altman plots were consistent with good agreement for all comparisons, with approximately 95% of values within limits of agreement. There was no difference in the three paired comparisons (aHKA, CT-aHKA, and sHKA) for knees with medial compartment arthritis. However, these findings were not replicated in knees with lateral compartment arthritis. CONCLUSIONS: There was no significant difference between the arithmetic HKA (whether obtained using CT or radiographs) and the stressed HKA in this analysis. These findings further validate the preoperative arithmetic method and support use of the intraoperative stressed HKA as techniques to restore constitutional lower limb alignment in KA TKA. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Tornozelo , Fenômenos Biomecânicos , Humanos , Articulação do Joelho , Extremidade Inferior , Estudos Retrospectivos
6.
Knee Surg Sports Traumatol Arthrosc ; 30(9): 2931-2940, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35075509

RESUMO

PURPOSE: Restricted kinematic alignment (rKA) in total knee arthroplasty (TKA) aims to restore native soft tissue laxities while limiting alignment extremes that risk prosthetic failure. However, there is no consensus where restricted boundaries (RB) should be set. This study aims to determine the proportion of limbs in which constitutional alignment and joint line obliquity (JLO) would be restored with various RB scenarios, to inform decision making in rKA TKA. METHODS: The mechanical hip-knee-ankle (mHKA) angle, arithmetic hip-knee-ankle (aHKA) angle, lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA) were measured on radiographs of 500 normal knees. Incrementally wider RBs were then applied. The proportion of limbs within each increment was determined when RBs were applied only to HKA, or to HKA, LDFA and MPTA together. In addition, the proportion of limbs within published adjusted mechanical alignment (aMA) and rKA protocols were determined, as well as those within one, two and three standard deviations of the means for HKA, LDFA and MPTA. RESULTS: When restrictions to mHKA alone were applied, 74.0% and 97.8% of knees were captured with boundaries of ± 3° and ± 6° respectively. However, when the same boundaries to HKA were also applied to MPTA and LDFA, 36.2% and 91.0% of knees were captured respectively, highlighting the limiting effect that JLO has on restoration of normal knee phenotypes. When comparing previously published boundaries, aMA of 0° ± 3° captured 36.2%; rKA of 0° ± 3 for HKA and 85° to 95° for LDFA/MPTA captured 67.8%; rKA of - 5° to 4° HKA and 86°-93° for LDFA/MPTA captured 63%; and rKA of - 6° to + 3° for HKA and 84°-93° for LDFA/MPTA captured 85.4%. CONCLUSION: The greatest proportions of normal knee phenotypes were captured with boundaries that were centred around population means for HKA and JLO. Further, these findings demonstrate that restricting the JLO has a significant limiting influence on restoration of normal knee phenotypes beyond that of restricting HKA alone. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Fraturas Ósseas , Osteoartrite do Joelho , Tomada de Decisões , Humanos , Articulação do Joelho , Fenótipo , Estudos Retrospectivos , Tíbia
7.
Knee Surg Sports Traumatol Arthrosc ; 30(8): 2806-2814, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34291311

RESUMO

PURPOSE: In total knee arthroplasty (TKA), knee phenotypes including joint line obliquity are of interest regarding surgical realignment strategies. The hypothesis of this study is that better clinical results, including decreased postoperative knee pain, will be observed for patients with a restored knee phenotype. METHODS: A retrospective analysis was performed on prospective data, including 1078 primary osteoarthritic knees in 936 patients. The male:female ratio was 780:298, mean age at surgery was 71.3 years ± 8.0. International Knee Society Scores and standardized long-leg radiographs (LLR) were collected preoperatively and at 2 years follow-up after TKA. Patients were categorized using the Coronal Plane Alignment of the Knee (CPAK) classification including the lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA) measured on LLR by a single observer, allowing knee phenotypes to be categorized considering the arithmetic hip-knee-ankle (aHKA) angle (MPTA-LDFA) as measure of constitutional alignment, and joint line obliquity (JLO) (MPTA + LDFA). Clinical results were compared between patients with surgically restored preoperative constitutional knee phenotype to patients without restored constitutional knee phenotypes. Descriptive data analysis such as means, standard deviations and ranges were performed. T tests for independent samples were performed to compare group differences. Comparisons of categorical data were performed using the χ2 test. Significance was set at p < 0.05. RESULTS: A third of patients (33.4%) had constitutional knee varus with apex distal JLO. 63.5% of patients had preoperative apex distal JLO. Postoperatively, 57.8% of patients had a neutral HKA (- 2° to 2°) and a neutral JLO (- 3° and 3°), with only 18% of patients with restored constitutional knee phenotype. Of these patients, statistically less postoperative pain was observed in patients where apex distal JLO was restored compared to non-restored apex distal JLO (pain score 46.7 vs. 44.6; p = 0.02) without clinical relevance. Other categories of restored JLO or arithmetic HKA angle were not associated with improved outcomes. CONCLUSION: This study showed that performing mechanical alignment for primary TKA resulted in most cases in a change of the preoperative knee phenotype. These results emphasize the relevance of considering joint line obliquity to better understand preoperative knee deformity and better restore knee phenotypes with a more personalized realignment strategy to potentially improve TKA postoperative results. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Fraturas Ósseas , Osteoartrite do Joelho , Artroplastia do Joelho/métodos , Feminino , Fraturas Ósseas/cirurgia , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Masculino , Osteoartrite do Joelho/cirurgia , Dor/cirurgia , Fenótipo , Estudos Prospectivos , Estudos Retrospectivos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
8.
Knee Surg Sports Traumatol Arthrosc ; 29(2): 498-506, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32170358

RESUMO

BACKGROUND: The accuracy of surgeon-defined assessment (SDA) of soft tissue balance in total knee arthroplasty (TKA) is poorly understood despite balance being considered a significant determinant of surgical success. The study's hypothesis was that intra-operative SDA is a poor predictor of coronal balance in TKA. METHODS: A prospective, multicenter study assessing accuracy of SDA of balance was conducted in 250 patients (285 TKAs). Eight surgeons and thirteen trainees participated, and all were blinded to sensor measurements. The primary outcome was test accuracy of SDA measured at 10°, 45° and 90° compared to sensor measures as the gold standard test. Cohen's kappa coefficient was calculated to determine chance-corrected agreement. Secondary outcomes include the relationship of SDA to level of surgical experience, analysis of between-surgeon differences, and the influence of patient and operative factors on SDA accuracy. RESULTS: Average accuracy of SDA was 58.3%, 61.2% and 66.5% at 10°, 45° and 90° respectively. Cohen's kappa coefficient was 0.18 at all angles and rated as "slight agreement". SDA sensitivities to correctly identify a balanced knee (76.2% at 10°; 82.6% at 45°; 83.2% at 90°) were approximately twice specificities to correctly identify an unbalanced knee (42.6% at 10°; 34.1% at 45°; 41.4% at 90°). Surgical experience (surgeon versus trainee) had no effect on capacity to determine balance. Considerable between-surgeon variability was found (33-65% at 10°, 41-73% at 45°, 55-89% at 90°). CONCLUSION: SDA was a poor predictor of balance, particularly when assessing the unbalanced TKA. Surgeon experience had no effect on test accuracy and considerable between-surgeon variability was recorded. These findings question the accuracy of SDA in TKA. TRIAL REGISTRATION NUMBER: ACTRN# 12618000817246.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Idoso , Fenômenos Biomecânicos , Feminino , Humanos , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Cirurgiões Ortopédicos , Osteoartrite do Joelho/cirurgia , Equilíbrio Postural , Estudos Prospectivos , Amplitude de Movimento Articular , Método Simples-Cego , Resultado do Tratamento
9.
J Arthroplasty ; 36(2): 514-519, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32928594

RESUMO

BACKGROUND: It is undetermined whether using sensors for knee balancing in total knee arthroplasty (TKA) improves patient outcomes. The purpose of this study was to compare clinical outcomes of sensor balance (SB) with manual balance (MB) TKA with a minimum two-year follow-up. METHODS: A consecutive series of 207 MB TKAs was compared with 222 SB TKAs between April 2014 and April 2017. A single surgeon performed all surgeries, using the same prosthesis. The primary end point was the aggregated mean change in four subscales of the Knee injury and Osteoarthritis Outcome Score (KOOS4) between preoperative and two-year time points. Secondary outcomes included mean differences between groups in all five KOOS subscales, proportions of knee balancing procedures, and rates of reoperations including revisions and manipulations for stiffness. RESULTS: The mean changes in the KOOS4 aggregated means for MB TKA (42.4; standard deviation, 29.1) and SB TKA (41.5; standard deviation, 25.0) were not significantly different (mean difference, 0.9; 95% confidence interval: -2.6 to 4.4, P = .62). There were significantly more balancing procedures in the SB group (55.9% versus 16.9%; P < .01). There were no significant differences in the number of reoperations (1.4% SB versus 1.4% MB; P = .71) or manipulations for stiffness (3.7% SB versus 4.4% MB; P = .69). CONCLUSION: The use of sensors in TKA to achieve knee balance did not result in improved clinical outcomes, despite significantly increasing the number of surgical interventions required to achieve a balanced knee. Sensors did not alter the rates of revision surgery or requirements for manipulation. It remains to be determined whether precise soft-tissue balancing improves prosthetic survivorship and joint biomechanics.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Seguimentos , Humanos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Resultado do Tratamento
10.
Knee Surg Sports Traumatol Arthrosc ; 28(9): 2808-2815, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31352496

RESUMO

PURPOSE: Biomechanical studies suggest that PF tracking is not reliably restored to physiological values in TKA despite surgical technique optimization. A clinical observation is that current TKA designs may not replicate anterior femoral offset. The aim was to examine the intraoperative resection thicknesses of the anterior femoral condyles during TKA and correlate these findings relative to modern prostheses. METHODS: This was a retrospective analysis of 199 patients who underwent 233 TKAs using a single implant design with measured anterior femoral condylar resection thicknesses. The aim was to restore posterior condylar offset whilst minimizing overstuffing of the anterior compartment of the knee by choosing the smallest prosthesis to allow for the maximal anterior resection as close to the cortex without inducing notching. Prosthetic measurements from 7 commonly used TKAs were collected by analysis of 3D models of median sized explants. RESULTS: An average of 7.9 mm (SD 2.5 mm, range 2-16.5 mm) and 11.5 mm (SD 2.5 mm, range 2-21 mm) was resected from the medial and lateral aspects of the anterior femur, respectively. The average anterior flange thickness for the prosthesis data set was 6.6 mm (SD 0.6 mm, range 6.1-7.9 mm) medially and 7.6 mm (SD 0.7 mm, range 6.8-9.0 mm) laterally. Comparison across patients who received the median prosthesis size of 5 (SD 1.3, range 2-8) was inadequately restored by 1.4 mm (p < 0.00001) medially and 3.4 mm (p < 0.00001) laterally. CONCLUSION: Host anatomy is not routinely restored during TKA. The surgical teaching to aim for an anterior femoral osteotomy close to the anterior cortex will result in understuffing of the PFJ and based on current prosthesis designs, the risk of overstuffing is not as significant as once believed. Future prostheses and surgical techniques should aim to restore not only posterior femoral but also anterior femoral offset. LEVEL OF EVIDENCE: IV, Case series.


Assuntos
Artroplastia do Joelho/instrumentação , Fêmur/anatomia & histologia , Articulação do Joelho/anatomia & histologia , Prótese do Joelho , Desenho de Prótese , Idoso , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Feminino , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
12.
J Arthroplasty ; 34(2): 290-294.e1, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30389257

RESUMO

BACKGROUND: Soft tissue balance is believed to be a major determinant of improved outcomes in total knee arthroplasty (TKA). We conducted this study to assess the accuracy of surgeon-defined assessment (SDA) of knee balance compared to pressure sensor data. We also assessed for any association between experience (learning curve) and accuracy of SDA. METHODS: A total of 308 patients undergoing 322 mechanically aligned TKA were prospectively analyzed. Femoral and tibial trial implants were inserted before performing knee balancing. We compared the surgeon determination on knee balance at 10°, 45°, and 90° of flexion to sensor data at the same flexion angles. RESULTS: Accuracy of SDA was 63%, 57.5%, and 63.8% at 10°, 45°, and 90°, respectively, when compared to sensor data. SDA had an overall sensitivity of 81% and specificity of 37.7%. Capacity to determine an unbalanced knee worsened at higher knee flexion angles with SDA test specificity of 53.5%, 34.8%, and 24.8% at 10°, 45°, and 90°, respectively (P = .0004 at 10° vs 45°, P < .0001 at 10° vs 90°). Cohen's kappa coefficient was 0.29 at 10° indicating fair agreement, and 0.14 and 0.12 at 45° and 90°, respectively, indicating poor agreement. The use of sensor had no time-based learning effect on capacity to determine knee balance. CONCLUSION: SDA is a poor predictor of the true soft tissue balance when compared to sensor data, particularly in assessing whether a knee is unbalanced. In addition, increased use of sensors did not improve surgeon capacity to determine knee balance.


Assuntos
Artroplastia do Joelho/instrumentação , Articulação do Joelho/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/métodos , Feminino , Fêmur/cirurgia , Humanos , Articulação do Joelho/fisiologia , Prótese do Joelho , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade , Pressão , Amplitude de Movimento Articular , Rotação , Cirurgiões , Tíbia/cirurgia
13.
J Arthroplasty ; 32(9): 2725-2729.e1, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28483212

RESUMO

BACKGROUND: Leg lengthening occurs in 83% of primary total knee arthroplasty (TKA). The effects of leg length discrepancy (LLD) on THA patients are well established. However, patient function and satisfaction associated with LLD after primary TKA has not been analyzed. This study aimed to quantify the magnitude of limb lengthening, identify radiographic and perceived LLD, and correlate these with predictive factors and functional outcomes in a series of TKA patients. METHODS: Patients undergoing primary TKA who met inclusion criteria were prospectively enrolled in this study. Leg length measurements were measured on standardized preoperative and postoperative long leg radiographs. Patients completed preoperative and 6-month postoperative Knee Society Score and functional Knee Injury and Osteoarthritis Outcome Score, as well as a postoperative satisfaction and customized leg length-specific functional questionnaire. RESULTS: Ninety-one patients undergoing TKA surgeries were included. Mean overall lengthening was 3.5 mm (range, -31.0 to 21.4 mm; SD, 8.4) with 77% of limbs lengthened; 89% of patients had no LLD (defined as ≥10 mm) after TKA. Postoperative radiographic LLD was associated with increased preoperative LLD (P < .001). Perceived postoperative LLD was associated with female gender (P = .02), decreased satisfaction (18% vs 84%; P < .001), and poorer functional score changes. Perceived LLD was not associated with radiographic LLD. CONCLUSION: Radiographic lengthened LLD is uncommon after primary TKA (11%) and does not correlate with perceived LLD. Patients with perceived LLD have decreased satisfaction and functional score improvements after TKA surgery.


Assuntos
Artroplastia do Joelho , Artropatias/fisiopatologia , Articulação do Joelho/cirurgia , Desigualdade de Membros Inferiores/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Alongamento Ósseo , Feminino , Humanos , Artropatias/cirurgia , Articulação do Joelho/fisiopatologia , Desigualdade de Membros Inferiores/cirurgia , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório
14.
J Arthroplasty ; 32(3): 777-782, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27667534

RESUMO

BACKGROUND: Accelerometer-based, portable navigation devices have been introduced as a less invasive and simpler technique to perform navigated surgical implantation of knee prostheses. They have been postulated to have better accuracy than conventional instruments in restoration of alignment in total knee arthroplasty. METHODS: A total of 190 patients were enrolled in this prospective, randomized controlled trial and underwent total knee arthroplasty using either the KneeAlign or conventional guides. Multiplanar alignment was evaluated with a CT imaging protocol. RESULTS: A total of 86.5% of portable navigation device and 82.2% of conventional group had a postoperative hip-knee angle within 3° of neutral alignment (P = .54). There was no significant difference between the 2 groups for component coronal and sagittal plane alignment. Portable navigation device did not significantly increase the time to perform the surgery. CONCLUSION: Portable navigation device demonstrates accurate restoration of alignment; however, there was no statistically significant difference when compared with conventional guides.


Assuntos
Artroplastia do Joelho/instrumentação , Cirurgia Assistida por Computador/instrumentação , Acelerometria , Idoso , Artroplastia do Joelho/métodos , Feminino , Humanos , Joelho/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Cirurgia Assistida por Computador/métodos
15.
J Arthroplasty ; 32(1): 28-32, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27567057

RESUMO

BACKGROUND: Tranexamic acid (TXA) is commonly used in primary total knee arthroplasty (TKA); however, the most appropriate route of administration is still debated. This study was conducted to compare the 2 most commonly used routes of TXA administration, intravenous (IV) and intra-articular (IA). METHODS: This study was conducted as a double-blind, randomized, noninferiority trial and included patients undergoing primary unilateral TKA. Patients were randomized to receive IV or IA TXA and compared for postoperative fall in hemoglobin (Hb) on day 1 (primary outcome) and day 2, and blood transfusion rates, length of stay, and complications. RESULTS: Of the 183 patients recruited, 168 were included and supplied complete data. The between-group difference in mean Hb fall at day 1 was 0.08 g/dL with the Hb fall higher in the IA group. The 95% confidence interval was -0.18 to 0.34 which did not reach the noninferiority margin of 0.5 g/dL. No significant difference was seen in the secondary outcomes. CONCLUSION: IA TXA is noninferior to IV TXA in terms of fall in Hb on the first postoperative day. Due to the potential for reduced serum levels and easier administration (single dose), this trial supports the use of IA TXA for primary TKA.


Assuntos
Antifibrinolíticos/administração & dosagem , Artroplastia do Joelho , Perda Sanguínea Cirúrgica/prevenção & controle , Ácido Tranexâmico/administração & dosagem , Administração Intravenosa , Idoso , Artroplastia do Joelho/efeitos adversos , Transfusão de Sangue , Método Duplo-Cego , Feminino , Hemoglobinas/análise , Humanos , Injeções Intra-Articulares , Masculino , Pessoa de Meia-Idade
16.
J Arthroplasty ; 29(6): 1138-42, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24524776

RESUMO

Patient specific guides (PSGs) are postulated to improve the alignment of components in total knee arthroplasty. Three hundred consecutive total knee arthroplasties performed with either conventional (CON) (n = 185) or Visionaire PSG (n = 115) were evaluated with a CT protocol for coronal limb alignment, coronal and sagittal alignment of individual components and femoral component rotation. There was no statistically significant difference between the two groups in any of the above parameters. In addition, no difference was found in total operative time. PSGs do not offer any benefit over conventional guides in terms improving the coronal alignment of the limb or alignment of individual components.


Assuntos
Artroplastia do Joelho/instrumentação , Fêmur/diagnóstico por imagem , Artropatias/cirurgia , Articulação do Joelho/cirurgia , Tíbia/diagnóstico por imagem , Tomografia Computadorizada Espiral , Idoso , Fêmur/cirurgia , Humanos , Artropatias/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Pessoa de Meia-Idade , Estudos Retrospectivos , Tíbia/cirurgia
17.
Bone Joint J ; 106-B(6): 525-531, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38821506

RESUMO

The aim of mechanical alignment in total knee arthroplasty is to align all knees into a fixed neutral position, even though not all knees are the same. As a result, mechanical alignment often alters a patient's constitutional alignment and joint line obliquity, resulting in soft-tissue imbalance. This annotation provides an overview of how the Coronal Plane Alignment of the Knee (CPAK) classification can be used to predict imbalance with mechanical alignment, and then offers practical guidance for bone balancing, minimizing the need for soft-tissue releases.


Assuntos
Artroplastia do Joelho , Articulação do Joelho , Humanos , Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Articulação do Joelho/diagnóstico por imagem , Fenômenos Biomecânicos , Mau Alinhamento Ósseo/diagnóstico por imagem
18.
Bone Jt Open ; 5(2): 109-116, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38325412

RESUMO

Aims: While mechanical alignment (MA) is the traditional technique in total knee arthroplasty (TKA), its potential for altering constitutional alignment remains poorly understood. This study aimed to quantify unintentional changes to constitutional coronal alignment and joint line obliquity (JLO) resulting from MA. Methods: A retrospective cohort study was undertaken of 700 primary MA TKAs (643 patients) performed between 2014 and 2017. Lateral distal femoral and medial proximal tibial angles were measured pre- and postoperatively to calculate the arithmetic hip-knee-ankle angle (aHKA), JLO, and Coronal Plane Alignment of the Knee (CPAK) phenotypes. The primary outcome was the magnitude and direction of aHKA, JLO, and CPAK alterations. Results: The mean aHKA and JLO increased by 0.1° (SD 3.4°) and 5.8° (SD 3.5°), respectively, from pre- to postoperatively. The most common phenotypes shifted from 76.3% CPAK Types I, II, or III (apex distal JLO) preoperatively to 85.0% IV, V, or VI (apex horizontal JLO) postoperatively. The proportion of knees with apex proximal JLO increased from 0.7% preoperatively to 11.1% postoperatively. Among all MA TKAs, 60.0% (420 knees) were changed from their constitutional alignments into CPAK Type V, while 40.0% (280 knees) either remained in constitutional Type V (5.0%, 35 knees) or were unintentionally aligned into other CPAK types (35.0%; 245 knees). Conclusion: Fixed MA targets in TKA lead to substantial changes from constitutional alignment, primarily a significant increase in JLO. These findings enhance our understanding of alignment alterations resulting from both unintended changes to knee phenotypes and surgical resection imprecision.

19.
J Arthroplasty ; 28(4): 620-3, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23107810

RESUMO

Total knee arthroplasty is a painful operation. Peri-articular local anesthetic injections reduce post-operative pain and assist recovery. It is inconclusive whether intra-operative injections of peri-articular corticosteroids are of benefit. Therefore our clinical question was: in patients with osteoarthritis who are undergoing TKA, does the addition of high or low dose corticosteroid to peri-articular injections of local anesthetic and adrenaline improve post-operative pain and range of motion? We performed a prospective, double-blinded, randomized controlled trial of two different doses of triamcinolone acetate (N = 42 in each group) added to local anesthetic in TKA for osteoarthritis. There were no significant differences in pain scores or ROM between the control and corticosteroid groups. Differences in secondary outcomes were also non-significant. Peri-articular corticosteroids do not appear to be of benefit in TKA.


Assuntos
Anestésicos Locais/administração & dosagem , Artroplastia do Joelho , Glucocorticoides/administração & dosagem , Dor Pós-Operatória/prevenção & controle , Triancinolona/administração & dosagem , Idoso , Método Duplo-Cego , Quimioterapia Combinada , Humanos , Injeções Intra-Articulares , Estudos Prospectivos
20.
Cureus ; 15(1): e34349, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36865978

RESUMO

BACKGROUND: Total knee arthroplasty (TKA) has become the treatment of choice for advanced osteoarthritis. Identifying malalignment is central to improving TKA outcomes and providing optimal management of TKA patients with post-operative pain and dissatisfaction. Computed tomography (CT) imaging has become increasingly popular as a more precise way of analysing post-TKA component alignment and the Perth CT protocol remains the current predominant assessment tool. This study aimed to analyse and compare inter- and intra-observer agreement of a post-operative multi-parameter quantitative CT assessment (Perth CT protocol) in TKA patients. METHODS: Post-operative CT images of 27 patients who underwent TKA were analysed retrospectively. Images were analysed by an experienced radiographer and a final-year medical student at least two weeks apart. Measurements for nine angles were collected: modified hip-knee-ankle (mHKA) angle, lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA), femoral flexion and tibial slope, femoral rotation angle, femoral-tibial match rotational angle, tibial tubercle lateralisation distance, and Berger's tibial rotation. Intra-observer and inter-observer intraclass correlation coefficients (ICCs) were calculated. RESULTS: Inter-observer reliability for the measurements of all variables varied from poor to excellent (ICC: -0.003 to 0.981). Five out of the nine angles demonstrated good to excellent reliability. Inter-observer reliability was highest for mHKA in the coronal plane and the poorest for the tibial slope angle in the sagittal plane. The intra-observer reliability for both reviewers was excellent (0.999 vs. 0.989). CONCLUSION: This study demonstrates that the Perth CT protocol has excellent intra-observer reliability and good to excellent inter-observer reliability for five out of nine of the measured angles used to assess component alignment post-TKA, making it a useful tool for surgical outcome prediction and success.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA