Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Clin Radiol ; 71(8): 779-95, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26944696

RESUMO

Magnetic resonance imaging (MRI) techniques provide non-invasive and non-ionising methods for the highly accurate anatomical depiction of the heart and vessels throughout the cardiac cycle. In addition, the intrinsic sensitivity of MRI to motion offers the unique ability to acquire spatially registered blood flow simultaneously with the morphological data, within a single measurement. In clinical routine, flow MRI is typically accomplished using methods that resolve two spatial dimensions in individual planes and encode the time-resolved velocity in one principal direction, typically oriented perpendicular to the two-dimensional (2D) section. This review describes recently developed advanced MRI flow techniques, which allow for more comprehensive evaluation of blood flow characteristics, such as real-time flow imaging, 2D multiple-venc phase contrast MRI, four-dimensional (4D) flow MRI, quantification of complex haemodynamic properties, and highly accelerated flow imaging. Emerging techniques and novel applications are explored. In addition, applications of these new techniques for the improved evaluation of cardiovascular (aorta, pulmonary arteries, congenital heart disease, atrial fibrillation, coronary arteries) as well as cerebrovascular disease (intra-cranial arteries and veins) are presented.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Transtornos Cerebrovasculares/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Humanos , Aumento da Imagem/métodos
2.
Lupus ; 24(11): 1126-34, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26038342

RESUMO

In the long-term survival of patients with systemic lupus erythematosus (SLE), cardiovascular disease (CVD) is a leading cause of death. Recently, multimodality cardiovascular imaging methods have been adopted for the evaluation of cardiovascular risk, which has shown to be associated with both traditional cardiovascular risk factors and SLE-specific conditions. Quantitative imaging biomarkers, which can describe both morphological and functional abnormalities in the heart, are expected to provide new insights to stratify cardiovascular risks and to guide SLE management by assessing individual responses to therapies either protecting the cardiovascular system or suppressing the autoimmune reactions. In this review, we will discuss cutting-edge cardiovascular imaging techniques and potential clinical applications and limitations of those techniques for the evaluation of major SLE-related heart disorders.


Assuntos
Doenças Cardiovasculares/complicações , Doenças Cardiovasculares/diagnóstico por imagem , Lúpus Eritematoso Sistêmico/complicações , Lúpus Eritematoso Sistêmico/diagnóstico por imagem , Adulto , Idoso , Diagnóstico por Imagem/métodos , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Radiografia
3.
Magn Reson Med ; 71(4): 1542-53, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23716466

RESUMO

PURPOSE: Changes in aortic geometry or presence of aortic valve (AoV) disease can result in substantially altered aortic hemodynamics. Dilatation of the ascending aorta or AoV abnormalities can result in an increase in helical flow. METHODS: 4D flow magnetic resonance imaging was used to test the feasibility of quantitative helicity analysis using equidistantly distributed 2D planes along the entire aorta. The evaluation of the method included three parts: (1) the quantification of helicity in 12 healthy subjects, (2) an evaluation of observer variability and test-retest reliability, and (3) the quantification of helical flow in 16 patients with congenitally altered bicuspid AoVs. RESULTS: Helicity quantification in healthy subjects revealed consistent directions of flow rotation along the entire aorta with high clockwise helicity in the aortic arch and an opposite rotation sense in the ascending and descending aorta. The results demonstrated good scan-rescan and inter- and intraobserver agreement of the helicity parameters. Helicity quantification in patients revealed a significant increase in absolute peak relative helicity during systole and a considerably greater heterogeneous distribution of mean helicity in the aorta. CONCLUSION: The method has the potential to serve as a reference distribution for comparisons of helical flow between healthy subjects and patients or between different patient groups.


Assuntos
Aorta/patologia , Aorta/fisiopatologia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/patologia , Doenças das Valvas Cardíacas/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Adulto , Valva Aórtica/patologia , Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Velocidade do Fluxo Sanguíneo , Técnicas de Imagem de Sincronização Cardíaca/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Eur Radiol ; 23(2): 339-47, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22886534

RESUMO

OBJECTIVES: The aim of this study was the evaluation of left ventricular (LV) segmental 3D velocities in patients with hypertensive heart disease using magnetic resonance (MR) tissue phase mapping (TPM). METHODS: LV radial, long-axis and rotational myocardial velocities were assessed by TPM in patients with LV hypertrophy and preserved EF (n = 18, age = 53 ± 12 years) and volunteers (n = 20, age = 51 ± 4 years). Systolic and diastolic peak and time-to-peak velocities were mapped onto a 16-segment LV model. 3D myocardial motion was displayed on an extended visualisation model. Correlation coefficients were calculated to investigate differences in regional dynamics. RESULTS: Patients revealed diastolic dysfunction as expressed by decreased peak long-axis velocities in all (except apical) segments (basal, P ≤ 0.01; two midventricular segments, P = 0.02, P = 0.03). During systole, hypertrophy was associated with heterogeneous behaviour for long-axis velocities including an increase in anteroseptal apical and midventricular regions (P = 0.001), a reduction in mid-inferior segments (P = 0.03) and enhanced septal velocities (P < 0.05). Segmental correlation analysis revealed altered dynamics of LV base rotation and increased dyssynchrony of lateral long-axis motion. CONCLUSIONS: Patients with hypertensive heart disease demonstrated alterations in systolic long-axis motion, basal rotation and dyssynchrony. Longitudinal studies are needed to investigate the value of regional wall motion abnormalities regarding disease progression and outcome.


Assuntos
Hipertensão/complicações , Hipertrofia Ventricular Esquerda/complicações , Hipertrofia Ventricular Esquerda/diagnóstico , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão , Adulto , Idoso , Estudos de Casos e Controles , Progressão da Doença , Feminino , Humanos , Hipertensão/diagnóstico , Masculino , Pessoa de Meia-Idade , Contração Miocárdica/fisiologia , Valores de Referência , Medição de Risco , Rotação , Sensibilidade e Especificidade , Índice de Gravidade de Doença
5.
Eur Radiol ; 23(12): 3361-9, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23812310

RESUMO

OBJECTIVES: To test the feasibility of four-dimensional (4D) flow MRI to quantify the systolic wall shear stress (WSSsystole) and oscillatory shear index (OSI) in high-grade internal carotid artery (ICA) stenosis before and after endarterectomy (CEA). METHODS: Twenty patients with ≥60 % ICA stenosis were prospectively and consequently included. Four-dimensional flow MRI was used to measure individual time-resolved 3D blood flow velocities. Segmental WSSsystole and OSI were derived at eight wall segments in analysis planes positioned along the ICA, common (CCA) and external carotid artery (ECA). RESULTS: Regional WSSsystole of all patients decreased after CEA (P < 0.05). Changes were most prominent at the ICA bulb but remained unchanged in the CCA and ECA. OSI was significantly lower after CEA in the lateral vessel walls (P < 0.05). For analysis planes at the stenosis in- and outlet, a reduction of mean WSSsystole by 32 % and 52 % (P < 0.001) and OSI distal to the stenosis (40 %, P = 0.01) was found after CEA. CONCLUSIONS: Our findings show the potential of in vivo 4D flow MRI to quantify haemodynamic changes in wall shear stress even in patients with complex flow conditions.


Assuntos
Artéria Carótida Interna/fisiopatologia , Estenose das Carótidas/fisiopatologia , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas , Hemodinâmica , Imageamento por Ressonância Magnética , Idoso , Velocidade do Fluxo Sanguíneo , Artéria Carótida Interna/patologia , Artéria Carótida Interna/cirurgia , Estenose das Carótidas/diagnóstico , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estudos Prospectivos , Estresse Mecânico , Sístole
6.
Magn Reson Med ; 67(1): 258-68, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21630351

RESUMO

The aim of this study was to evaluate the performance of a closed circuit MR compatible pneumatically driven pump system using a ventricular assist device as pulsatile flow pump for in vitro 3D flow simulation. Additionally, a pressure control unit was integrated into the flow circuit. The performance of the pump system and its test-retest reliability was evaluated using a stenosis phantom (60% lumen narrowing). Bland-Altman analysis revealed a good test-retest reliability (mean differences = -0.016 m/s, limits of agreement = ±0.047 m/s) for in vitro flow measurements. Furthermore, a rapid prototyping in vitro model of a normal thoracic aorta was integrated into the flow circuit for a direct comparison of flow characteristics with in vivo data in the same subject. The pneumatically driven ventricular assist device was attached to the ascending aorta of the in vitro model to simulate the beating left ventricle. In the descending part of the healthy aorta a flexible stenosis was integrated to model an aortic coarctation. In vivo and in vitro comparison showed significant (P = 0.002) correlations (r = 0.9) of mean velocities. The simulation of increasing coarctation grade led to expected changes in the flow patterns such as jet flow in the post-stenotic region and increased velocities.


Assuntos
Determinação da Pressão Arterial/instrumentação , Coração Auxiliar , Imageamento por Ressonância Magnética/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Retroalimentação
7.
Magn Reson Med ; 66(2): 402-9, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21381100

RESUMO

Parallel imaging based on generalized autocalibrating partially parallel acquisitions is widely used in the clinical routine. To date, no detailed analysis has been presented describing the dependence of the image quality on the reconstruction and acquisition parameters such as the number of autocalibration signal (ACS) lines NACS, the reconstruction kernel size (bx×by), and the undersampling factor R. To evaluate their influence on the performance of generalized autocalibrating partially parallel acquisitions, two phantom data sets acquired with 12-channel and 32-channel receive coils and three in vivo measurements were analyzed. Reconstruction parameters were systematically varied between R=2-4, NACS=4-64, bx=1-9, and by=2-10 to characterize their influence on image quality and noise. A main aspect of the analysis was to optimize the parameter set with respect to the effectively achieved net image acceleration. Selecting the undersampling factor R as small as possible for a given net acceleration yielded the best result in a clear majority of cases. For all data sets and coil geometries, the optimal kernel sizes and number of ACS lines were similar for a chosen undersampling factor R. In summary, the number of ACS lines should not be chosen below NACS=10-16. A robust choice for the kernel size was bx=9 and by=2-4.


Assuntos
Algoritmos , Artefatos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
J Magn Reson Imaging ; 34(3): 518-25, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21761462

RESUMO

PURPOSE: To employ magnetic resonance tissue phase mapping (TPM) for the assessment of age-related left ventricular (LV) synchrony of radial and long-axis motion in healthy volunteers and in hypertensive heart disease, dilated cardiomyopathy (DCM), and left bundle branch block (LBBB). MATERIALS AND METHODS: TPM (spatial/temporal resolution = 1.3 × 2.6 mm(2)/13.8 msec) was employed to measure radial and long-axis myocardial velocities in 58 healthy volunteers of three age groups and 37 patients (hypertensive, n = 18; DCM, n = 12; DCM and LBBB n = 7). Regional times-to-peak velocities (TTP) in systole and diastole were derived for all LV segments. Four measures of dyssynchrony were defined as the standard deviation of systolic and diastolic TTP for radial and long-axis motion. RESULTS: Systolic radial and diastolic long-axis dyssynchrony was increased (P < 0.01) in all patient groups compared to controls. Multiple regressions revealed a significant relationship of dyssynchrony with LV ejection fraction and mass for systolic radial (P < 0.001 resp. P = 0.02), diastolic radial (P < 0.001 resp. P < 0.05), and long-axis (P < 0.001 resp. P = 0.001) motion. Diastolic dyssynchrony correlated with the LV remodeling index (P < 0.05) and increased with age (P < 0.03). Systolic long-axis dyssynchrony was not influenced by disease or LV function. CONCLUSION: Radial systolic and long-axis diastolic dyssynchrony were the most sensitive markers for altered dyssynchrony in hypertensive heart disease or DCM. Future studies are needed to evaluate the diagnostic value of TPM-derived dyssynchrony parameters.


Assuntos
Envelhecimento/patologia , Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Disfunção Ventricular Esquerda/patologia , Disfunção Ventricular Esquerda/fisiopatologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Eur Radiol ; 21(8): 1651-7, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21720942

RESUMO

OBJECTIVES: Comprehensive analysis of haemodynamics by 3D flow visualisation and retrospective flow quantification in patients after repair of tetralogy of Fallot (TOF). METHODS: Time-resolved flow-sensitive 4D MRI (spatial resolution ~ 2.5 mm, temporal resolution = 38.4 ms) was acquired in ten patients after repair of TOF and in four healthy controls. Data analysis included the evaluation of haemodynamics in the aorta, the pulmonary trunk (TP) and left (lPA) and right (rPA) pulmonary arteries by 3D blood flow visualisation using particle traces, and quantitative measurements of flow velocity. RESULTS: 3D visualisation of whole heart haemodynamics provided a comprehensive overview on flow pattern changes in TOF patients, mainly alterations in flow velocity, retrograde flow and pathological vortices. There was consistently higher blood flow in the rPA of the patients (rPA/lPA flow ratio: 2.6 ± 2.5 vs. 1.1 ± 0.1 in controls). Systolic peak velocity in the TP was higher in patients (1.9 m/s ± 0.7 m/s) than controls (0.9 m/s ± 0.1 m/s). CONCLUSIONS: 4D flow-sensitive MRI permits the comprehensive evaluation of blood flow characteristics in patients after repair of TOF. Altered flow patterns for different surgical techniques in the small patient cohort may indicate its value for patient monitoring and potentially identifying optimal surgical strategies.


Assuntos
Imageamento por Ressonância Magnética/métodos , Tetralogia de Fallot/fisiopatologia , Tetralogia de Fallot/cirurgia , Adolescente , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Criança , Pré-Escolar , Feminino , Hemodinâmica , Humanos , Imageamento Tridimensional , Lactente , Masculino , Adulto Jovem
10.
Eur Radiol ; 21(5): 1026-33, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21085967

RESUMO

OBJECTIVES: To evaluate the image quality of time-resolved contrast-enhanced MRA (tr-MRA) employing echo-sharing with stochastic trajectories for the bilateral examination of the hands. METHODS: In this institutional review-board approved study, Tr-MRA was compared with multiphasic contrast-enhanced MRA (mp-MRA) featuring sub-systolic venous compression in 20 healthy volunteers at 3.0 T using the following settings: TR/TE: 2.8/1.2 ms, flip angle: 25°, acceleration factor: 4, effective voxel size: 0.9 × 0.8 × 0.9 cm, acquisition time 4.9 s per 3D volume. RESULTS: With tr-MRA the arterial first-pass contrast agent transit is clearly seen. On average the contrast agent arrived 34 s post-injection and reached the proper digital arteries after 44 s. The mean arterio-venous window was 13 s. Bilateral contrast enhancement was asynchronous in 56-62%. On a semiquantitative scale (0 = non-sufficient to 4 = excellent) tr-MRA (mp-MRA) yielded an average ranking of 2.8-3.6 (3.1-3.8) in the greater and intermediate sized segments and 1.3-2.0 (1.6-2.3) in the proper digital arteries. CONCLUSION: Compared with established multiphasic ce-MRA, time-resolved MRA allows a four times faster acquisition. It reflects the natural haemodynamics of the hand arteries with no need for sub-systolic venous compression and may be beneficial in the detection of hand circulation disorders. Image quality is comparable to mp-MRA. In both techniques depiction of the proper digital arteries is limited.


Assuntos
Mãos/patologia , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Meios de Contraste/farmacologia , Diagnóstico por Imagem/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Isquemia/patologia , Masculino , Software , Processos Estocásticos , Fatores de Tempo
11.
Pediatr Radiol ; 41(10): 1333-6, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21674287

RESUMO

Neonatal aortic dissection is rare and most frequently iatrogenic. Decision making and appropriate imaging are highly challenging for pediatric cardiologists and radiologists. We present MRI and echocardiographic findings in the follow-up at 6 months of age of a boy with a conservatively treated iatrogenic neonatal aortic dissection (type B). To evaluate the morphology of the aortic arch and descending aorta, we carried out multidirectional time-resolved three-dimensional flow-analysis and contrast-enhanced MR angiography (CE-MRA). The MRI and Doppler echocardiographic results were closely comparable. Three-dimensional visualization helped assess details of blood flow acceleration and alteration caused by the dissection, and played a key role in our deciding not to treat surgically.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico , Dissecção Aórtica/diagnóstico , Angiografia por Ressonância Magnética/métodos , Anormalidades Múltiplas , Dissecção Aórtica/diagnóstico por imagem , Angiografia Digital , Aneurisma da Aorta Torácica/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Meios de Contraste , Ecocardiografia Doppler , Humanos , Doença Iatrogênica , Imageamento Tridimensional , Lactente , Recém-Nascido , Masculino
12.
Magn Reson Med ; 61(1): 65-74, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19097219

RESUMO

To determine three-dimensional (3D) blood flow patterns in the carotid bifurcation, 10 healthy volunteers and nine patients with internal carotid artery (ICA) stenosis > or =50% were examined by flow-sensitive 4D MRI at 3T. Absolute and mean blood velocities, pulsatility index (PI), and resistance index (RI) were measured in the common carotid arteries (CCAs) by duplex sonography (DS) and compared with flow-sensitive 4D MRI. Furthermore, 3D MRI blood flow patterns in the carotid bifurcation of volunteers and patients before and after recanalization were graded by two independent readers. Blood flow velocities measured by MRI were 31-39% lower than in DS. However, PI and RI differed by only 13-16%. Rating of 3D flow characteristics in the ICA revealed consistent patterns for filling and helical flow in volunteers. In patients with ICA stenosis, 3D blood flow visualization was successfully employed to detect markedly altered filling and helical flow patterns (forward-moving spiral flow) in the ICA bulb and to evaluate the effect of revascularization, which restored filling and helical flow. Our results demonstrate the feasibility of flow-sensitive 4D MRI for the quantification and 3D visualization of physiological and pathological flow patterns in the carotid artery bifurcation.


Assuntos
Velocidade do Fluxo Sanguíneo , Artérias Carótidas/fisiopatologia , Estenose das Carótidas/diagnóstico , Estenose das Carótidas/fisiopatologia , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Reologia/métodos , Adulto , Idoso , Algoritmos , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Acta Radiol ; 50(8): 909-13, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19639472

RESUMO

Recent advances in flow-sensitive magnetic resonance imaging (MRI) and data analysis allow for comprehensive noninvasive three-dimensional (3D) visualization of complex blood flow. Electrocardiogram (ECG)-gated three-directional (3dir) flow measurements were employed to assess and visualize time-resolved 3D blood flow in the pulmonary arteries (PA) and thoracic aorta. We present findings in a juvenile patient with surgically corrected transposition of the great arteries (d-TGA) and aortic coarctation. For the first time, the complex flow patterns in the PA following d-TGA were visualized. Morphologically, a slight asymmetry of the PA was found, with considerable impact on vascular hemodynamics, resulting in diastolic retrograde flow in the larger vessel and diastolic filling of the smaller PA. Additionally, increased flow to the supraaortic vessels was found due to aortic coarctation.


Assuntos
Imagem Cinética por Ressonância Magnética/métodos , Transposição dos Grandes Vasos/fisiopatologia , Adolescente , Aorta Torácica/fisiopatologia , Velocidade do Fluxo Sanguíneo , Eletrocardiografia , Humanos , Imageamento Tridimensional , Masculino , Artéria Pulmonar/fisiopatologia , Transposição dos Grandes Vasos/cirurgia
14.
Nervenarzt ; 80(8): 929-40, 2009 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-19319500

RESUMO

Magnetic resonance imaging allows detailed visualization of the thoracic aorta and is not limited by air artefacts or insonation angles like transoesophageal echocardiography (TEE). Thus the aortic arch can be investigated with higher accuracy, and additional embolic high-risk sources such as complex plaques can be additionally detected by MRI in patients with cryptogenic stroke. Furthermore, MRI provides exact 3D plaque localisation and can be combined with multidirectional 3D MRI velocity mapping. In this way, previously not demonstrable retrograde flow paths originating at complex descending aortic plaques reaching the supra-aortic great arteries can be identified as the probable stroke mechanism in certain patients. The same technique can also be applied to the carotid arteries. This allows analysing the complex 3D helical flow within the internal carotid artery as well as measuring absolute flow velocities and wall shear stress in combination with data on vessel anatomy derived from conventional MR angiography. It is the purpose of this work to describe the state of the art of these modern MR imaging techniques and their potential to identify potential stroke mechanisms, and to analyse the particular role of individual haemodynamic factors on the development of local atherosclerosis.


Assuntos
Doenças da Aorta/complicações , Doenças da Aorta/diagnóstico , Doenças das Artérias Carótidas/complicações , Doenças das Artérias Carótidas/diagnóstico , Angiografia por Ressonância Magnética/métodos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Diagnóstico Diferencial , Humanos
16.
Magn Reson Med ; 60(3): 631-9, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18727081

RESUMO

The purpose of the study was to evaluate the performance of steady-state free precession (SSFP)-tagging at 1.5T and 3T and to define the ideal settings with respect to optimized tag contrast throughout the cardiac cycle for both field strengths. To identify optimal imaging parameters data acquisition was repeated for different flip angles. Left ventricular tag-tissue contrast, tag fading times, tag persistence, and myocardial signal-to-noise ratio (SNR) were quantified in basal, mid-ventricular, and apical slice locations. To assess the effect of field strength on image quality and artifact level, additional semiquantitative image grading was performed by two experienced readers. SSFP-tagging at 3T proved superior to 1.5T and provided significantly enhanced tag persistence and myocardial SNR while maintaining overall image quality and artifact level. The definition of a tag quality index demonstrated optimal SSFP-tagging performance for a flip angle of 20 degrees . Diastolic tag visibility was improved at 3T and resulted in enhanced average tag persistence of 789 +/- 128 ms compared to 523 +/- 40 ms at 1.5T. For SSFP-tagging at 3T the combination of T(1) lengthening and superior myocardial SNR is highly promising and has the potential to improve the depiction of tagged myocardial function throughout the entire cardiac cycle.


Assuntos
Ventrículos do Coração/metabolismo , Angiografia por Ressonância Magnética/métodos , Contração Miocárdica , Adulto , Feminino , Humanos , Aumento da Imagem , Angiografia por Ressonância Magnética/normas , Masculino , Adulto Jovem
17.
Magn Reson Med ; 60(5): 1218-31, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18956416

RESUMO

Quantification of CINE phase contrast (PC)-MRI data is a challenging task because of the limited spatiotemporal resolution and signal-to-noise ratio (SNR). The method presented in this work combines B-spline interpolation and Green's theorem to provide optimized quantification of blood flow and vessel wall parameters. The B-spline model provided optimal derivatives of the measured three-directional blood velocities onto the vessel contour, as required for vectorial wall shear stress (WSS) computation. Eight planes distributed along the entire thoracic aorta were evaluated in a 19-volunteer study using both high-spatiotemporal-resolution planar two-dimensional (2D)-CINE-PC ( approximately 1.4 x 1.4 mm(2)/24.4 ms) and lower-resolution 3D-CINE-PC ( approximately 2.8 x 1.6 x 3 mm(3)/48.6 ms) with three-directional velocity encoding. Synthetic data, error propagation, and interindividual, intermodality, and interobserver variability were used to evaluate the reliability and reproducibility of the method. While the impact of MR measurement noise was only minor, the limited resolution of PC-MRI introduced systematic WSS underestimations. In vivo data demonstrated close agreement for flow and WSS between 2D- and 3D-CINE-PC as well as observers, and confirmed the reliability of the method. WSS analysis along the aorta revealed the presence of a circumferential WSS component accounting for 10-20%. Initial results in a patient with atherosclerosis suggest the potential of the method for understanding the formation and progression of cardiovascular diseases.


Assuntos
Aorta Torácica/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Técnicas de Imagem por Elasticidade/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Algoritmos , Aorta Torácica/anatomia & histologia , Módulo de Elasticidade , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resistência ao Cisalhamento , Estresse Mecânico
18.
Rheumatology (Oxford) ; 47(1): 65-7, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18077491

RESUMO

OBJECTIVE: To determine the effect of corticosteroid treatment on mural inflammatory hyperenhancement in MRI in GCA. METHODS: MRI of the superficial temporal artery with sub-millimetre in-plane spatial resolution (195 x 260 microm) was performed in 17 patients with proven GCA at the initiation of corticosteroid treatment and after 16 months of therapy. Visual MRI scores for mural inflammation were correlated with clinical and laboratory findings. RESULTS: Intensity of inflammatory hyperenhancement decreased significantly under corticosteroid therapy (2.3 +/- 0.6 vs 0.5 +/- 0.6, P < 0.001, with MRI score >2 indicating vasculitis). This finding correlated with the clinical and serological remission in 15/17 patients. Of the two patients with active disease, one had persisting mural inflammation in MRI indicative of relapsing disease. The other patient presenting with signs of polymyalgia rheumatica had no inflammatory changes of the superficial temporal arteries on MRI scan at follow-up. CONCLUSIONS: Mural contrast enhancement in high-resolution MRI is pronounced in active disease and decreases under corticosteroid treatment, correlating well with laboratory remission.


Assuntos
Artérias Cerebrais/patologia , Arterite de Células Gigantes/diagnóstico , Glucocorticoides/uso terapêutico , Angiografia por Ressonância Magnética/métodos , Prednisolona/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Sedimentação Sanguínea , Proteína C-Reativa/análise , Meios de Contraste/administração & dosagem , Feminino , Gadolínio DTPA/administração & dosagem , Arterite de Células Gigantes/sangue , Arterite de Células Gigantes/tratamento farmacológico , Humanos , Aumento da Imagem , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
19.
J Neurol Neurosurg Psychiatry ; 79(5): 540-6, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-17965147

RESUMO

OBJECTIVES: To evaluate a new three dimensional (3D) MRI protocol for the reliable detection of aortic high risk plaques compared with transoesophageal echocardiography (TOE) and to test the reliability of additional MRI in stroke of undetermined aetiology. METHODS: 74 acute stroke patients were examined by both TOE and MRI at 3 Tesla with special regard to aortic high risk plaques (ie, > OR = 4 mm, superimposed thrombi). ECG synchronised pre- and post-contrast T1 weighted 3D imaging (spatial resolution approximately 1 mm3) covering the thoracic aorta was employed. In plaques > OR = 3 mm, additional two dimensional T2 imaging and time resolved (CINE) imaging sequences were performed. Aetiology of brain ischaemia was classified according to modified TOAST (Trial of Org 10172 in Acute Stroke Treatment) criteria. Aortic high risk embolic sources detected by MRI in patients with cryptogenic stroke were evaluated. RESULTS: Differences in maximum aortic wall thickness for TOE and MRI were not statistically significant for all aortic segments. The overall number of high risk plaques detected by MRI (n = 74) was substantially higher compared with TOE (n = 47). Most noticeably, MRI identified aortic high risk pathologies in 8/26 (30.8%) patients with cryptogenic stroke after standard diagnostics, including TOE (n = 2: dissection or thrombus; n = 6: plaques > OR = 4 mm). CONCLUSIONS: Our results demonstrate the feasibility of this 3D MRI protocol for the reliable detection of aortic high risk plaques in acute stroke patients. Because of improved visualisation of the aortic arch and the detection of additional embolic sources not seen by standard diagnostics, this novel technique may become a valuable tool for future patients with cryptogenic stroke.


Assuntos
Doenças da Aorta/diagnóstico , Aterosclerose/diagnóstico , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Embolia Intracraniana/etiologia , Imagem Cinética por Ressonância Magnética , Imageamento por Ressonância Magnética , Doença Aguda , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico , Aorta Torácica , Aneurisma Aórtico/complicações , Aneurisma Aórtico/diagnóstico , Doenças da Aorta/complicações , Aterosclerose/complicações , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco , Trombose/complicações , Trombose/diagnóstico
20.
HNO ; 56(12): 1233-8, 2008 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-18488183

RESUMO

Reports on acquired traumatic laryngomalacia appear only rarely in the literature. We report a case of a 47-year-old patient with breathlessness after a transcervical approach to the spine during general anesthesia with intubation. Laryngostroboscopy revealed a smooth and, during inspiration, retroflexed epiglottis at the posterior pharyngeal wall. Additionally, dynamic magnetic resonance imaging for the first time showed hypermobility of the upper edge of the epiglottis. After partial laser epiglottectomy, the patient's complaints disappeared.


Assuntos
Epiglote/lesões , Epiglote/cirurgia , Laminectomia/efeitos adversos , Laringomalácia/etiologia , Laringomalácia/cirurgia , Feminino , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA