Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 389(16): 1466-1476, 2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37634188

RESUMO

BACKGROUND: Data regarding clinical outcomes after optical coherence tomography (OCT)-guided percutaneous coronary intervention (PCI) as compared with angiography-guided PCI are limited. METHODS: In this prospective, randomized, single-blind trial, we randomly assigned patients with medication-treated diabetes or complex coronary-artery lesions to undergo OCT-guided PCI or angiography-guided PCI. A final blinded OCT procedure was performed in patients in the angiography group. The two primary efficacy end points were the minimum stent area after PCI as assessed with OCT and target-vessel failure at 2 years, defined as a composite of death from cardiac causes, target-vessel myocardial infarction, or ischemia-driven target-vessel revascularization. Safety was also assessed. RESULTS: The trial was conducted at 80 sites in 18 countries. A total of 2487 patients underwent randomization: 1233 patients were assigned to undergo OCT-guided PCI, and 1254 to undergo angiography-guided PCI. The minimum stent area after PCI was 5.72±2.04 mm2 in the OCT group and 5.36±1.87 mm2 in the angiography group (mean difference, 0.36 mm2; 95% confidence interval [CI], 0.21 to 0.51; P<0.001). Target-vessel failure within 2 years occurred in 88 patients in the OCT group and in 99 patients in the angiography group (Kaplan-Meier estimates, 7.4% and 8.2%, respectively; hazard ratio, 0.90; 95% CI, 0.67 to 1.19; P = 0.45). OCT-related adverse events occurred in 1 patient in the OCT group and in 2 patients in the angiography group. Stent thrombosis within 2 years occurred in 6 patients (0.5%) in the OCT group and in 17 patients (1.4%) in the angiography group. CONCLUSIONS: Among patients undergoing PCI, OCT guidance resulted in a larger minimum stent area than angiography guidance, but there was no apparent between-group difference in the percentage of patients with target-vessel failure at 2 years. (Funded by Abbott; ILUMIEN IV: OPTIMAL PCI ClinicalTrials.gov number, NCT03507777.).


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Tomografia de Coerência Óptica , Humanos , Angiografia Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Método Simples-Cego , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Diabetes Mellitus , Implante de Prótese Vascular/métodos , Stents
2.
Circulation ; 147(6): 469-481, 2023 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-36524476

RESUMO

BACKGROUND: Patients with diabetes have increased rates of major adverse cardiac events (MACEs). We hypothesized that this is explained by diabetes-associated differences in coronary plaque morphology and lipid content. METHODS: In PROSPECT II (Providing Regional Observations to Study Predictors of Events in the Coronary Tree), 898 patients with acute myocardial infarction with or without ST-segment elevation underwent 3-vessel quantitative coronary angiography and coregistered near-infrared spectroscopy and intravascular ultrasound imaging after successful percutaneous coronary intervention. Subsequent MACEs were adjudicated to either treated culprit lesions or untreated nonculprit lesions. This substudy stratified patients by diabetes status and assessed baseline culprit and nonculprit prevalence of high-risk plaque characteristics defined as maximum plaque burden ≥70% and maximum lipid core burden index ≥324.7. Separate covariate-adjusted multivariable models were performed to identify whether diabetes was associated with nonculprit lesion-related MACEs and high-risk plaque characteristics. RESULTS: Diabetes was present in 109 of 898 patients (12.1%). During a median 3.7-year follow-up, MACEs occurred more frequently in patients with versus without diabetes (20.1% versus 13.5% [odds ratio (OR), 1.94 (95% CI, 1.14-3.30)]), primarily attributable to increased risk of myocardial infarction related to culprit lesion restenosis (4.3% versus 1.1% [OR, 3.78 (95% CI, 1.12-12.77)]) and nonculprit lesion-related spontaneous myocardial infarction (9.3% versus 3.8% [OR, 2.74 (95% CI, 1.25-6.04)]). However, baseline prevalence of high-risk plaque characteristics was similar for patients with versus without diabetes concerning culprit (maximum plaque burden ≥70%: 90% versus 93%, P=0.34; maximum lipid core burden index ≥324.7: 66% versus 70%, P=0.49) and nonculprit lesions (maximum plaque burden ≥70%: 23% versus 22%, P=0.37; maximum lipid core burden index ≥324.7: 26% versus 24%, P=0.47). In multivariable models, diabetes was associated with MACEs in nonculprit lesions (adjusted OR, 2.47 [95% CI, 1.21-5.04]) but not with prevalence of high-risk plaque characteristics (adjusted OR, 1.21 [95% CI, 0.86-1.69]). CONCLUSIONS: Among patients with recent myocardial infarction, both treated and untreated lesions contributed to the diabetes-associated ≈2-fold increased MACE rate during the 3.7-year follow-up. Diabetes-related plaque characteristics that might underlie this increased risk were not identified by multimodality imaging. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02171065.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Diabetes Mellitus , Infarto do Miocárdio , Intervenção Coronária Percutânea , Placa Aterosclerótica , Humanos , Doença da Artéria Coronariana/complicações , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Síndrome Coronariana Aguda/terapia , Placa Aterosclerótica/complicações , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Infarto do Miocárdio/complicações , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/patologia , Angiografia Coronária/métodos , Intervenção Coronária Percutânea/efeitos adversos , Lipídeos , Valor Preditivo dos Testes , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 103(6): 833-842, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38639137

RESUMO

BACKGROUND: Stent underexpansion, typically related to lesion calcification, is the strongest predictor of adverse events after percutaneous coronary intervention (PCI). Although uncommon, underexpansion may also occur in non-severely calcified lesions. AIM: We sought to identify the prevalence and anatomical characteristics of underexpansion in non-severely calcified lesions. METHODS: We included 993 patients who underwent optical coherence tomography-guided PCI of 1051 de novo lesions with maximum calcium arc <180°. Negative remodeling (NR) was the smallest lesion site external elastic lamina diameter that was also smaller than the distal reference. Stent expansion was evaluated using a linear regression model accounting for vessel tapering; underexpansion required both stent expansion <70% and stent area <4.5mm2. RESULTS: Underexpansion was observed in 3.6% of non-heavily calcified lesions (38/1051). Pre-stent maximum calcium arc and thickness were greater in lesions with versus without underexpansion (median 119° vs. 85°, p = 0.002; median 0.95 mm vs. 0.78 mm, p = 0.008). NR was also more common in lesions with underexpansion (44.7% vs. 24.5%, p = 0.007). In the multivariable logistic regression model, larger and thicker eccentric calcium, mid left anterior descending artery (LAD) location, and NR were associated with underexpansion in non-severely calcified lesions. The rate of underexpansion was especially high (30.7%) in lesions exhibiting all three morphologies. Two-year TLF tended to be higher in underexpanded versus non-underexpanded stents (9.7% vs. 3.7%, unadjusted hazard ratio [95% confidence interval] = 3.02 [0.92, 9.58], p = 0.06). CONCLUSION: Although underexpansion in the absence of severe calcium (<180°) is uncommon, mid-LAD lesions with NR and large and thick eccentric calcium were associated with underexpansion.


Assuntos
Doença da Artéria Coronariana , Vasos Coronários , Intervenção Coronária Percutânea , Stents , Tomografia de Coerência Óptica , Calcificação Vascular , Humanos , Masculino , Feminino , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/efeitos adversos , Idoso , Pessoa de Meia-Idade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Prevalência , Fatores de Risco , Vasos Coronários/diagnóstico por imagem , Resultado do Tratamento , Estudos Retrospectivos , Índice de Gravidade de Doença , Desenho de Prótese , Valor Preditivo dos Testes , Fatores de Tempo , Angiografia Coronária , Remodelação Vascular
4.
Curr Cardiol Rep ; 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38809401

RESUMO

PURPOSE OF REVIEW: To provide a summary of prevalence, pathogenesis, and treatment of coronary calcified nodules (CNs). RECENT FINDINGS: CNs are most frequently detected at the sites of hinge motion of severely calcified lesions such as in the middle segment of right coronary artery and left main coronary bifurcation. On histopathology, CNs exhibit two distinctive morphologies: eruptive and non-eruptive. Eruptive CNs, which have a disrupted fibrous cap with adherent thrombi, are biologically active. Non-eruptive CNs, which have an intact fibrous cap without thrombi, are biologically inactive, representing either healed eruptive CNs or protrusion of calcium due to plaque progression. Recent studies using optical coherence tomography (OCT) have shown a difference in the mechanism of stent failure in the two subtypes, demonstrating early reappearance of eruptive CNs in the stent (at ~ 6 months) as a unique mechanism of stent failure that does not seem to be preventable by simply achieving adequate stent expansion. The cause of CN reappearance in stent is not known and could be due to acute or subacute intrusion or continued growth of the CN. Whether modification of CN is needed, the most effective calcium modification modality and effectiveness of stent implantation in eruptive CNs has not been elucidated. In this review, we discuss pathogenesis of CNs and how intravascular imaging can help diagnose and manage patients with CNs. We also discuss medical and transcatheter therapies beyond conventional stent implantation for effective treatment of eruptive CNs that warrant testing in prospective studies.

5.
Circulation ; 143(7): 624-640, 2021 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-33191769

RESUMO

BACKGROUND: Myocardial infarction with nonobstructive coronary arteries (MINOCA) occurs in 6% to 15% of myocardial infarctions (MIs) and disproportionately affects women. Scientific statements recommend multimodality imaging in MINOCA to define the underlying cause. We performed coronary optical coherence tomography (OCT) and cardiac magnetic resonance (CMR) imaging to assess mechanisms of MINOCA. METHODS: In this prospective, multicenter, international, observational study, we enrolled women with a clinical diagnosis of myocardial infarction. If invasive coronary angiography revealed <50% stenosis in all major arteries, multivessel OCT was performed, followed by CMR (cine imaging, late gadolinium enhancement, and T2-weighted imaging and T1 mapping). Angiography, OCT, and CMR were evaluated at blinded, independent core laboratories. Culprit lesions identified by OCT were classified as definite or possible. The CMR core laboratory identified ischemia-related and nonischemic myocardial injury. Imaging results were combined to determine the mechanism of MINOCA, when possible. RESULTS: Among 301 women enrolled at 16 sites, 170 were diagnosed with MINOCA, of whom 145 had adequate OCT image quality for analysis; 116 of these underwent CMR. A definite or possible culprit lesion was identified by OCT in 46.2% (67/145) of participants, most commonly plaque rupture, intraplaque cavity, or layered plaque. CMR was abnormal in 74.1% (86/116) of participants. An ischemic pattern of CMR abnormalities (infarction or myocardial edema in a coronary territory) was present in 53.4% (62/116) of participants undergoing CMR. A nonischemic pattern of CMR abnormalities (myocarditis, takotsubo syndrome, or nonischemic cardiomyopathy) was present in 20.7% (24/116). A cause of MINOCA was identified in 84.5% (98/116) of the women with multimodality imaging, higher than with OCT alone (P<0.001) or CMR alone (P=0.001). An ischemic cause was identified in 63.8% of women with MINOCA (74/116), a nonischemic cause was identified in 20.7% (24/116) of the women, and no mechanism was identified in 15.5% (18/116). CONCLUSIONS: Multimodality imaging with coronary OCT and CMR identified potential mechanisms in 84.5% of women with a diagnosis of MINOCA, 75.5% of which were ischemic and 24.5% of which were nonischemic, alternate diagnoses to myocardial infarction. Identification of the cause of MINOCA is feasible and has the potential to guide medical therapy for secondary prevention. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02905357.


Assuntos
Vasos Coronários/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Idoso , Vasos Coronários/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Estudos Prospectivos
6.
Lancet ; 397(10278): 985-995, 2021 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-33714389

RESUMO

BACKGROUND: Near-infrared spectroscopy (NIRS) and intravascular ultrasound are promising imaging modalities to identify non-obstructive plaques likely to cause coronary-related events. We aimed to assess whether combined NIRS and intravascular ultrasound can identify high-risk plaques and patients that are at risk for future major adverse cardiac events (MACEs). METHODS: PROSPECT II is an investigator-sponsored, multicentre, prospective natural history study done at 14 university hospitals and two community hospitals in Denmark, Norway, and Sweden. We recruited patients of any age with recent (within past 4 weeks) myocardial infarction. After treatment of all flow-limiting coronary lesions, three-vessel imaging was done with a combined NIRS and intravascular ultrasound catheter. Untreated lesions (also known as non-culprit lesions) were identified by intravascular ultrasound and their lipid content was assessed by NIRS. The primary outcome was the covariate-adjusted rate of MACEs (the composite of cardiac death, myocardial infarction, unstable angina, or progressive angina) arising from untreated non-culprit lesions during follow-up. The relations between plaques with high lipid content, large plaque burden, and small lumen areas and patient-level and lesion-level events were determined. This trial is registered with ClinicalTrials.gov, NCT02171065. FINDINGS: Between June 10, 2014, and Dec 20, 2017, 3629 non-culprit lesions were characterised in 898 patients (153 [17%] women, 745 [83%] men; median age 63 [IQR 55-70] years). Median follow-up was 3·7 (IQR 3·0-4·4) years. Adverse events within 4 years occurred in 112 (13·2%, 95% CI 11·0-15·6) of 898 patients, with 66 (8·0%, 95% CI 6·2-10·0) arising from 78 untreated non-culprit lesions (mean baseline angiographic diameter stenosis 46·9% [SD 15·9]). Highly lipidic lesions (851 [24%] of 3500 lesions, present in 520 [59%] of 884 patients) were an independent predictor of patient-level non-culprit lesion-related MACEs (adjusted odds ratio 2·27, 95% CI 1·25-4·13) and non-culprit lesion-specific MACEs (7·83, 4·12-14·89). Large plaque burden (787 [22%] of 3629 lesions, present in 530 [59%] of 898 patients) was also an independent predictor of non-culprit lesion-related MACEs. Lesions with both large plaque burden by intravascular ultrasound and large lipid-rich cores by NIRS had a 4-year non-culprit lesion-related MACE rate of 7·0% (95% CI 4·0-10·0). Patients in whom one or more such lesions were identified had a 4-year non-culprit lesion-related MACE rate of 13·2% (95% CI 9·4-17·6). INTERPRETATION: Combined NIRS and intravascular ultrasound detects angiographically non-obstructive lesions with a high lipid content and large plaque burden that are at increased risk for future adverse cardiac outcomes. FUNDING: Abbott Vascular, Infraredx, and The Medicines Company.


Assuntos
Infarto do Miocárdio/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Ultrassonografia/métodos , Idoso , Angina Instável/epidemiologia , Morte , Feminino , Humanos , Lipídeos/análise , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Placa Aterosclerótica/química , Estudos Prospectivos , Países Escandinavos e Nórdicos
7.
Catheter Cardiovasc Interv ; 100(4): 687-695, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35842776

RESUMO

OBJECTIVES: The aim of this study was to compare the ability of two different atherectomy modalities, the directional atherectomy system (DAS) and the orbital atherectomy system (OAS), to modify plaque and augment luminal gain as evaluated by angiography and intravascular ultrasound (IVUS) in patients with symptomatic femoro-popliteal peripheral arterial disease (PAD). BACKGROUND: Atherectomy is frequently utilized in the treatment of complex PAD. To date, there are no head-to-head comparisons of existing devices and their selection is based mostly on operator preference rather than on supportive data. METHODS: This was a single-center, prospective, randomized trial designed to assess the impact of DAS in comparison to OAS on atherosclerotic plaque. Pre- and postatherectomy lesion characterization was performed by angiography and IVUS. Drug-coated balloon (DCB) angioplasty was performed after atherectomy with similar analysis repeated. RESULTS: Sixty patients were randomized to undergo either DAS or OAS. Pretreatment angiographic and IVUS characteristics were similar in the DAS and OAS groups. DAS led to a greater reduction in plaque volume throughout the entire lesion (5.9% vs. 1.1%, p = 0.003). This corresponded to a greater increase in total vessel and lumen volume by IVUS (161.5 mm3 vs. 50.2 mm3 , p = 0.001; 178.6 mm3 vs. 47.0 mm3 , p = 0.004, respectively), as well as a reduction in angiographic stenosis (40% vs. 70%, p < 0.001). After DCB, 10 patients required stenting for suboptimal results in the OAS group compared with two in the DAS group (p = 0.021). CONCLUSIONS: Compared to OAS, DAS demonstrated a greater plaque volume reduction and luminal gain with significantly fewer stents needed post-DCB.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Placa Aterosclerótica , Humanos , Angiografia , Angioplastia com Balão/efeitos adversos , Aterectomia/efeitos adversos , Materiais Revestidos Biocompatíveis , Artéria Femoral/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Artéria Poplítea/diagnóstico por imagem , Estudos Prospectivos , Resultado do Tratamento , Ultrassonografia de Intervenção , Grau de Desobstrução Vascular
8.
Catheter Cardiovasc Interv ; 99(7): 2028-2037, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35419936

RESUMO

OBJECTIVES: The purpose of the current study was to use intravascular ultrasound (IVUS) to clarify anatomical and morphological lesion characteristics of uncrossable lesions. BACKGROUND: Uncrossable lesions are not always severely calcified. The prevalence of uncrossable lesions that are nonseverely calcified as well as other mechanisms for uncrossability has not been well clarified. METHODS: A total of 252 de novo uncrossable lesions in native coronary arteries that underwent either rotational or orbital atherectomy due to inability of any balloon to cross the lesion and 38 lesions with severe calcium in which IVUS crossed preatherectomy were included. Severe calcium is defined as maximum arc of calcium ≥270°. RESULTS: Severe calcification was absent in 16% of uncrossable lesions, 83% of which had a significant vessel bend. Compared with crossable lesions with severe calcium, uncrossable lesions with severe calcium more often had a bend in the vessel (71% vs. 21%, p < 0.001) and a longer length of continuous severe calcium (median length of calcium ≥270° 3.8 mm vs. 1.9 mm, p = 0.001). Other than severe calcium (especially long continuous calcium) or a bend in the vessel, anatomical factors associated with uncrossabilty were aorto-ostial lesion location and small vessels. CONCLUSIONS: Uncrossable lesions are not always severely calcified. The interaction of lesion morphology (continuous long and large arcs of calcium) and vessel geometry (bend in the vessel or ostial lesion location) affect lesion crossability.


Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana , Calcificação Vascular , Aterectomia Coronária/efeitos adversos , Cálcio , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Resultado do Tratamento , Ultrassonografia de Intervenção , Calcificação Vascular/diagnóstico por imagem
9.
Catheter Cardiovasc Interv ; 98(3): 483-491, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-32915510

RESUMO

OBJECTIVES: We sought to evaluate the severity and patterns of calcifications in the left main coronary artery (LMCA) and proximal segments of left anterior descending coronary artery (LAD) and left circumflex artery (LCX) using optical coherence tomography (OCT) in patients with and without prior coronary artery bypass grafting (CABG). BACKGROUND: CABG may accelerate upstream calcium development. METHODS: OCT images (n = 76) of the LMCA bifurcation from either the LAD or LCX in 76 patients with at least one patent left coronary graft, on average 7.0 ± 5.6 years post-CABG, were compared with 148 OCT images in propensity-score-matched non-CABG controls. RESULTS: Minimum lumen areas in the LMCA, LAD, and LCX in post-CABG patients were smaller than non-CABG controls. Maximum calcium arc and thickness as well as calcium length were greater in the LMCA and LCX, but not in the LAD in post-CABG patients versus non-CABG controls. Calcium located at the carina of a bifurcation, calcified nodules (CN), thin intimal calcium, and lobulated calcium were more prevalent in post-CABG patients. After adjusting for multiple covariates, prior CABG was an independent predictor of calcification at the carina of a bifurcation (odds ratio [OR] 5.77 [95% confidence interval, CI: 1.5-21.6]), thin intimal calcium (4.7 [1.5-14.4]), and the presence of a CN (15.60 [3.2-76.2]). CONCLUSIONS: Prior CABG is associated with greater amount of calcium in the LMCA and the proximal LCX, as well as higher prevalence of atypical calcium patterns, including CN, thin or lobulated calcium, and calcifications located at the carina of a bifurcation, compared with non-CABG controls.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Tomografia de Coerência Óptica , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 98(5): E677-E686, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34357673

RESUMO

OBJECTIVES: This study was conducted to use optical coherence tomography (OCT) to compare vascular healing between bioresorbable polymer (BP) and durable polymer (DP) everolimus-eluting stents (EES) in patients with acute coronary syndromes (ACS). BACKGROUND: Whether BP-EES induce better vascular healing compared to contemporary DP-EES remains controversial, especially for ACS. METHODS: In this prospective, randomized, non-inferiority trial, we used OCT to compare 6-month vascular healing in patients with ACS randomized to BP versus DP-EES: percent strut coverage (primary endpoint, non-inferiority margin of 2.0%) and neointimal thickness and percent neointimal hyperplasia (NIH) volume. As an exploratory analysis, morphological factors related to the endpoints and the effect of underlying lipidic plaque on stent healing were evaluated. RESULTS: A total of 104 patients with ACS were randomly assigned to BP-EES (n = 52) versus DP-EES (n = 52). Of these, 86 patients (40 BP-EES and 46 DP-EES) were included in the final OCT analyses. Six-month percent strut coverage of BP-EES (83.6 ± 11.4%) was not non-inferior compared to those of DP-EES (81.6 ± 13.9%), difference 2.0% (lower 95% confidence interval-2.6%), pnon-inferiority  = 0.07. There were no differences in neointimal thickness 70.0 ± 33.9 µm versus 67.2 ± 33.9 µm, p = 0.71; and percent NIH volume 7.5 ± 4.7% versus 7.3 ± 5.3%, p = 0.85. By multivariable linear regression analysis, stent type was not associated with percent strut coverage or percent NIH volume; however, percent baseline embedded struts or stent expansion was positively associated with percent NIH volume. Greater NIH volume was observed in lipidic compared with non-lipidic segments (8.7 ± 5.6% vs. 6.1 ± 5.2%, p = 0.005). CONCLUSIONS: Six-month strut coverage of BP-EES was not non-inferior compared to those of DP-EES in ACS patients. Good stent apposition and expansion were independently associated with better vascular healing.


Assuntos
Síndrome Coronariana Aguda , Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/cirurgia , Humanos , Polímeros , Estudos Prospectivos , Sirolimo , Tomografia de Coerência Óptica , Resultado do Tratamento
11.
Biomed Eng Online ; 20(1): 34, 2021 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-33823858

RESUMO

BACKGROUND: Coronary plaque vulnerability prediction is difficult because plaque vulnerability is non-trivial to quantify, clinically available medical image modality is not enough to quantify thin cap thickness, prediction methods with high accuracies still need to be developed, and gold-standard data to validate vulnerability prediction are often not available. Patient follow-up intravascular ultrasound (IVUS), optical coherence tomography (OCT) and angiography data were acquired to construct 3D fluid-structure interaction (FSI) coronary models and four machine-learning methods were compared to identify optimal method to predict future plaque vulnerability. METHODS: Baseline and 10-month follow-up in vivo IVUS and OCT coronary plaque data were acquired from two arteries of one patient using IRB approved protocols with informed consent obtained. IVUS and OCT-based FSI models were constructed to obtain plaque wall stress/strain and wall shear stress. Forty-five slices were selected as machine learning sample database for vulnerability prediction study. Thirteen key morphological factors from IVUS and OCT images and biomechanical factors from FSI model were extracted from 45 slices at baseline for analysis. Lipid percentage index (LPI), cap thickness index (CTI) and morphological plaque vulnerability index (MPVI) were quantified to measure plaque vulnerability. Four machine learning methods (least square support vector machine, discriminant analysis, random forest and ensemble learning) were employed to predict the changes of three indices using all combinations of 13 factors. A standard fivefold cross-validation procedure was used to evaluate prediction results. RESULTS: For LPI change prediction using support vector machine, wall thickness was the optimal single-factor predictor with area under curve (AUC) 0.883 and the AUC of optimal combinational-factor predictor achieved 0.963. For CTI change prediction using discriminant analysis, minimum cap thickness was the optimal single-factor predictor with AUC 0.818 while optimal combinational-factor predictor achieved an AUC 0.836. Using random forest for predicting MPVI change, minimum cap thickness was the optimal single-factor predictor with AUC 0.785 and the AUC of optimal combinational-factor predictor achieved 0.847. CONCLUSION: This feasibility study demonstrated that machine learning methods could be used to accurately predict plaque vulnerability change based on morphological and biomechanical factors from multi-modality image-based FSI models. Large-scale studies are needed to verify our findings.


Assuntos
Aprendizado de Máquina , Placa Aterosclerótica/diagnóstico por imagem , Tomografia de Coerência Óptica , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Ultrassonografia
12.
Circulation ; 139(4): 477-484, 2019 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-30586699

RESUMO

BACKGROUND: Measuring fractional flow reserve (FFR) with a pressure wire remains underutilized because of the invasiveness of guide wire placement or the need for a hyperemic stimulus. FFR derived from routine coronary angiography (FFRangio) eliminates both of these requirements and displays FFR values of the entire coronary tree. The FFRangio Accuracy versus Standard FFR (FAST-FFR) study is a prospective, multicenter, international trial with the primary goal of determining the accuracy of FFRangio. METHODS: Coronary angiography was performed in a routine fashion in patients with suspected coronary artery disease. FFR was measured in vessels with coronary lesions of varying severity using a coronary pressure wire and hyperemic stimulus. Based on angiograms of the respective arteries acquired in ≥2 different projections, on-site operators blinded to FFR then calculated FFRangio using proprietary software. Coprimary end points were the sensitivity and specificity of the dichotomously scored FFRangio for predicting pressure wire-derived FFR using a cutoff value of 0.80. The study was powered to meet prespecified performance goals for sensitivity and specificity. RESULTS: Ten centers in the United States, Europe, and Israel enrolled a total of 301 subjects and 319 vessels meeting inclusion/exclusion criteria which were included in the final analysis. The mean FFR was 0.81 and 43% of vessels had an FFR≤0.80. The per-vessel sensitivity and specificity were 94% (95% CI, 88% to 97%) and 91% (86% to 95%), respectively, both of which exceeded the prespecified performance goals. The diagnostic accuracy of FFRangio was 92% overall and remained high when only considering FFR values between 0.75 to 0.85 (87%). FFRangio values correlated well with FFR measurements ( r=0.80, P<0.001) and the Bland-Altman 95% confidence limits were between -0.14 and 0.12. The device success rate for FFRangio was 99%. CONCLUSIONS: FFRangio measured from the coronary angiogram alone has a high sensitivity, specificity, and accuracy compared with pressure wire-derived FFR. FFRangio has the promise to substantially increase physiological coronary lesion assessment in the catheterization laboratory, thereby potentially leading to improved patient outcomes. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique Identifier: NCT03226262.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Imageamento Tridimensional/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Cateterismo Cardíaco , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Europa (Continente) , Feminino , Humanos , Israel , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Estados Unidos
13.
Catheter Cardiovasc Interv ; 96(1): E53-E58, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31631521

RESUMO

OBJECTIVE: The primary objective was to demonstrate diagnostic equivalence between RFR and iFR in clinical practice. BACKGROUND: The instantaneous wave-free ratio (iFR), a nonhyperemic pressure ratio (NHPR), has been shown to be noninferior to fractional flow reserve (FFR) in determining coronary artery stenosis severity in intermediate lesions. However, iFR has a number of inherent limitations, including sensitive landmarking of the pressure waveform and the assumption that maximal flow and minimal microcirculatory resistance occur during a fixed period within diastole. The resting full-cycle ratio (RFR) is a novel NHPR which evaluates the entire cardiac cycle independent of the ECG, landmark identification, and timing within the cardiac cycle. METHODS: RE-VALIDATE RFR was designed to determine the diagnostic utility of RFR for the physiological assessment of coronary artery disease in clinical practice compared to iFR. RFR was also tested for equivalence (1% margin), diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), areas under the receiver operated characteristic curve (AUC), and correlations compared to calculated iFR (iFRcalc ). RESULTS: From two centers, 501 blinded rest- and hyperemic pressure recordings from 431 patients were suitable for analysis according to a core laboratory. The mean FFR, RFR, and iFRcalc were 0.80 ± 0.09, 0.90 ± 0.08, and 0.90 ± 0.08, respectively. Based on a binary cut-off approach (RFR/iFR ≤0.89), RFR demonstrated equivalence with iFRcalc (95% confidence interval: 0.025-0.019) with overall diagnostic accuracy 97.8%, sensitivity 97.8%, specificity 97.8%, PPV 96.2%, NPV 98.7%, and AUC 0.96 (0.94-0.97, p < .001). RFR had a mean bias 0.003 (95% limits of agreement: 0.019, -0.025). CONCLUSIONS: RFR was equivalent to iFR in clinical practice. RFR is an alternative NHPR, avoiding the need for hyperemic agents, thus potentially reducing side effects, procedural time and cost compared to FFR.


Assuntos
Cateterismo Cardíaco , Estenose Coronária/diagnóstico , Reserva Fracionada de Fluxo Miocárdico , Hiperemia/fisiopatologia , Idoso , Estenose Coronária/fisiopatologia , Feminino , Georgia , Humanos , Masculino , Pessoa de Meia-Idade , Cidade de Nova Iorque , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
14.
Biomed Eng Online ; 19(1): 90, 2020 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-33256759

RESUMO

BACKGROUND: Detecting coronary vulnerable plaques in vivo and assessing their vulnerability have been great challenges for clinicians and the research community. Intravascular ultrasound (IVUS) is commonly used in clinical practice for diagnosis and treatment decisions. However, due to IVUS limited resolution (about 150-200 µm), it is not sufficient to detect vulnerable plaques with a threshold cap thickness of 65 µm. Optical Coherence Tomography (OCT) has a resolution of 15-20 µm and can measure fibrous cap thickness more accurately. The aim of this study was to use OCT as the benchmark to obtain patient-specific coronary plaque cap thickness and evaluate the differences between OCT and IVUS fibrous cap quantifications. A cap index with integer values 0-4 was also introduced as a quantitative measure of plaque vulnerability to study plaque vulnerability. METHODS: Data from 10 patients (mean age: 70.4; m: 6; f: 4) with coronary heart disease who underwent IVUS, OCT, and angiography were collected at Cardiovascular Research Foundation (CRF) using approved protocol with informed consent obtained. 348 slices with lipid core and fibrous caps were selected for study. Convolutional Neural Network (CNN)-based and expert-based data segmentation were performed using established methods previously published. Cap thickness data were extracted to quantify differences between IVUS and OCT measurements. RESULTS: For the 348 slices analyzed, the mean value difference between OCT and IVUS cap thickness measurements was 1.83% (p = 0.031). However, mean value of point-to-point differences was 35.76%. Comparing minimum cap thickness for each plaque, the mean value of the 20 plaque IVUS-OCT differences was 44.46%, ranging from 2.36% to 91.15%. For cap index values assigned to the 348 slices, the disagreement between OCT and IVUS assignments was 25%. However, for the OCT cap index = 2 and 3 groups, the disagreement rates were 91% and 80%, respectively. Furthermore, the observation of cap index changes from baseline to follow-up indicated that IVUS results differed from OCT by 80%. CONCLUSIONS: These preliminary results demonstrated that there were significant differences between IVUS and OCT plaque cap thickness measurements. Large-scale patient studies are needed to confirm our findings.


Assuntos
Vasos Coronários/diagnóstico por imagem , Tomografia de Coerência Óptica , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Placa Aterosclerótica/diagnóstico por imagem , Ultrassonografia
15.
Catheter Cardiovasc Interv ; 93(3): 411-418, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-30345635

RESUMO

OBJECTIVE: We sought to evaluate whether automated coregistration of optical coherence tomography (OCT) with angiography reduces geographic miss (GM) during coronary stenting. BACKGROUND: Previous intravascular ultrasound or OCT studies have showed that residual disease at the stent edge or stent edge dissection was associated with stent thrombosis or edge restenosis. This has been termed GM. METHODS: Two hundred de novo coronary lesions were randomized in a 1:1 ratio to OCT-guided percutaneous coronary intervention (PCI) with versus without automated coregistration of OCT with angiography. GM, the primary endpoint, was defined as angiographic ≥type B dissection or diameter stenosis >50% or OCT minimum lumen area <4.0 mm2 with significant residual disease or dissection (dissection flap >60°) within 5 mm from the stent edge. RESULTS: The prevalence of GM was not different comparing OCT-guided PCI with versus without automated coregistration (27.6% vs 34.0%, P = 0.33). However, there was a trend toward a reduced prevalence of significant distal stent edge dissection in lesions with automated coregistration (11.1% vs 20.8%, P = 0.07). The discrepancy in the distance between planned versus actual implanted stent location with automated coregistration was significantly shorter than without coregistration (1.9 ± 1.6 mm vs 2.6 ± 2.7 mm, P = 0.03), especially the prevalence of ≥5 mm discrepancy that was less frequent with automated coregistration. CONCLUSIONS: Automated coregistration of OCT with angiography did not reduce the primary endpoint of GM after stent implantation.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Intervenção Coronária Percutânea , Tomografia de Coerência Óptica , Idoso , Automação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , New York , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Valor Preditivo dos Testes , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Stents , Fatores de Tempo , Resultado do Tratamento
16.
J Biomech Eng ; 141(9)2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31141591

RESUMO

Medical image resolution has been a serious limitation in plaque progression research. A modeling approach combining intravascular ultrasound (IVUS) and optical coherence tomography (OCT) was introduced and patient follow-up IVUS and OCT data were acquired to construct three-dimensional (3D) coronary models for plaque progression investigations. Baseline and follow-up in vivo IVUS and OCT coronary plaque data were acquired from one patient with 105 matched slices selected for model construction. 3D fluid-structure interaction (FSI) models based on IVUS and OCT data (denoted as IVUS + OCT model) were constructed to obtain stress/strain and wall shear stress (WSS) for plaque progression prediction. IVUS-based IVUS50 and IVUS200 models were constructed for comparison with cap thickness set as 50 and 200 µm, respectively. Lumen area increase (LAI), plaque area increase (PAI), and plaque burden increase (PBI) were chosen to measure plaque progression. The least squares support vector machine (LS-SVM) method was employed for plaque progression prediction using 19 risk factors. For IVUS + OCT model with LAI, PAI, and PBI, the best single predictor was plaque strain, local plaque stress, and minimal cap thickness, with prediction accuracy as 0.766, 0.838, and 0.890, respectively; the prediction accuracy using best combinations of 19 factors was 0.911, 0.881, and 0.905, respectively. Compared to IVUS + OCT model, IVUS50, and IVUS200 models had errors ranging from 1% to 66.5% in quantifying cap thickness, stress, strain and prediction accuracies. WSS showed relatively lower prediction accuracy compared to other predictors in all nine prediction studies.

17.
Molecules ; 24(3)2019 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-30691115

RESUMO

Macrophages play an important role in the regulation of inflammation and immune response as well as the pathogenesis of chronic inflammatory diseases and cancer. Therefore, targeted delivery of therapeutic reagents to macrophages is an effective method for treatment and diagnosis. We previously examined the therapeutic applications of polyrotaxanes (PRXs) comprised of multiple cyclodextrins (CDs) threaded on a polymer chain and capped with bulky stopper molecules. In the present study, we designed an α-d-mannose-modified α-CD/poly(ethylene glycol)-based PRX (Man-PRX). The intracellular uptake of Man-PRX through the interaction with macrophage mannose receptor (MMR) in macrophage-like RAW264.7 cells was examined. Intracellular Man-PRX uptake was observed in MMR-positive RAW264.7 cells but was negligible in MMR-negative NIH/3T3 cells. In addition, the intracellular Man-PRX uptake in RAW264.7 cells was significantly inhibited in the presence of free α-d-mannose and an anti-MMR antibody, which suggests that MMR is involved in the intracellular uptake of Man-PRX. Moreover, the polarization of RAW264.7 cells affected the Man-PRX internalization efficiency. These results indicate that Man-PRX is an effective candidate for selective targeting of macrophages through a specific interaction with the MMR.


Assuntos
Endocitose/efeitos dos fármacos , Macrófagos/efeitos dos fármacos , Macrófagos/fisiologia , Manose/química , Receptores de Superfície Celular/metabolismo , Rotaxanos/química , Rotaxanos/farmacologia , Animais , Polaridade Celular/efeitos dos fármacos , Espectroscopia de Ressonância Magnética , Camundongos , Células NIH 3T3 , Células RAW 264.7 , Rotaxanos/síntese química
18.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 75(11): 1286-1296, 2019.
Artigo em Japonês | MEDLINE | ID: mdl-31748454

RESUMO

The work of radiological technologists is changing and more complicated because of the development of medical technology and implementation of information technology (IT). Although the cases of incident and accident have been reported, they have not been comprehensively analyzed in the workflow for radiotherapy. In this study, we visualized the workflow of radiological technologists in radiotherapy and revealed the causes of incidents and accidents. The work process was visualized by drawing workflow map. The structuring of problem was performed with interpretive structural modeling (ISM) method based on graph theory by analyzing of work categorized by safety management. Our results may be able to clarify the work of radiological technologists leads to the reduction of incidents and accidents in radiation therapy.


Assuntos
Bases de Dados Factuais , Fluxo de Trabalho , Acidentes , Gestão da Segurança
19.
Lancet ; 388(10060): 2618-2628, 2016 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-27806900

RESUMO

BACKGROUND: Percutaneous coronary intervention (PCI) is most commonly guided by angiography alone. Intravascular ultrasound (IVUS) guidance has been shown to reduce major adverse cardiovascular events (MACE) after PCI, principally by resulting in a larger postprocedure lumen than with angiographic guidance. Optical coherence tomography (OCT) provides higher resolution imaging than does IVUS, although findings from some studies suggest that it might lead to smaller luminal diameters after stent implantation. We sought to establish whether or not a novel OCT-based stent sizing strategy would result in a minimum stent area similar to or better than that achieved with IVUS guidance and better than that achieved with angiography guidance alone. METHODS: In this randomised controlled trial, we recruited patients aged 18 years or older undergoing PCI from 29 hospitals in eight countries. Eligible patients had one or more target lesions located in a native coronary artery with a visually estimated reference vessel diameter of 2·25-3·50 mm and a length of less than 40 mm. We excluded patients with left main or ostial right coronary artery stenoses, bypass graft stenoses, chronic total occlusions, planned two-stent bifurcations, and in-stent restenosis. Participants were randomly assigned (1:1:1; with use of an interactive web-based system in block sizes of three, stratified by site) to OCT guidance, IVUS guidance, or angiography-guided stent implantation. We did OCT-guided PCI using a specific protocol to establish stent length, diameter, and expansion according to reference segment external elastic lamina measurements. All patients underwent final OCT imaging (operators in the IVUS and angiography groups were masked to the OCT images). The primary efficacy endpoint was post-PCI minimum stent area, measured by OCT at a masked independent core laboratory at completion of enrolment, in all randomly allocated participants who had primary outcome data. The primary safety endpoint was procedural MACE. We tested non-inferiority of OCT guidance to IVUS guidance (with a non-inferiority margin of 1·0 mm2), superiority of OCT guidance to angiography guidance, and superiority of OCT guidance to IVUS guidance, in a hierarchical manner. This trial is registered with ClinicalTrials.gov, number NCT02471586. FINDINGS: Between May 13, 2015, and April 5, 2016, we randomly allocated 450 patients (158 [35%] to OCT, 146 [32%] to IVUS, and 146 [32%] to angiography), with 415 final OCT acquisitions analysed for the primary endpoint (140 [34%] in the OCT group, 135 [33%] in the IVUS group, and 140 [34%] in the angiography group). The final median minimum stent area was 5·79 mm2 (IQR 4·54-7·34) with OCT guidance, 5·89 mm2 (4·67-7·80) with IVUS guidance, and 5·49 mm2 (4·39-6·59) with angiography guidance. OCT guidance was non-inferior to IVUS guidance (one-sided 97·5% lower CI -0·70 mm2; p=0·001), but not superior (p=0·42). OCT guidance was also not superior to angiography guidance (p=0·12). We noted procedural MACE in four (3%) of 158 patients in the OCT group, one (1%) of 146 in the IVUS group, and one (1%) of 146 in the angiography group (OCT vs IVUS p=0·37; OCT vs angiography p=0·37). INTERPRETATION: OCT-guided PCI using a specific reference segment external elastic lamina-based stent optimisation strategy was safe and resulted in similar minimum stent area to that of IVUS-guided PCI. These data warrant a large-scale randomised trial to establish whether or not OCT guidance results in superior clinical outcomes to angiography guidance. FUNDING: St Jude Medical.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção/métodos , Idoso , Vasos Coronários/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento
20.
Cardiovasc Diabetol ; 16(1): 7, 2017 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-28086778

RESUMO

BACKGROUND: Adenosine-free coronary pressure wire metrics have been proposed to test the functional significance of coronary artery lesions, but it is unexplored whether their diagnostic performance might be altered in patients with diabetes. METHODS: We performed a post-hoc analysis of the CONTRAST study, which prospectively enrolled an international cohort of patients undergoing routine fractional flow reserve (FFR) assessment for standard indications. Paired, repeated measurements of all physiology metrics (Pd/Pa, iFR, contrast-based FFR, and FFR) were made. A central core laboratory analyzed blinded pressure tracings in a standardized fashion. RESULTS: Of 763 subjects enrolled at 12 international centers, 219 (29%) had diabetes. The two groups were well-balanced for age, clinical presentation (stable or unstable), coronary vessel studied, volume and type of intracoronary contrast, and volume of intracoronary adenosine. A binary threshold of cFFR ≤ 0.83 produced an accuracy superior to both Pd/Pa and iFR when compared with FFR ≤ 0.80 in the absence of significant interaction with diabetes status; indeed, accuracy in subgroups of patients with or without diabetes was similar for cFFR (86.7 vs 85.4% respectively; p = 0.76), iFR (84.2 vs 80.0%, p = 0.29) and Pd/Pa (81.3 vs 78.9%, p = 0.55). There was no significant heterogeneity between patients with or without diabetes in terms of sensitivity and specificity of all metrics. The area under the receiver operating characteristic (ROC) curve was largest for cFFR compared with Pd/Pa and iFR which were equivalent (cFFR 0.961 and 0.928; Pd/Pa 0.916 and 0.870; iFR 0.911 and 0.861 in diabetic and non-diabetic patients respectively). CONCLUSIONS: cFFR provides superior diagnostic performance compared with Pd/Pa or iFR for predicting FFR irrespective of diabetes (clinicaltrials.gov identifier NCT02184117).


Assuntos
Meios de Contraste , Diabetes Mellitus/diagnóstico por imagem , Diabetes Mellitus/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Internacionalidade , Idoso , Estudos de Coortes , Meios de Contraste/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA