Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 131
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Exp Eye Res ; 244: 109930, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38750782

RESUMO

Corneal neovascularization (CoNV) is a vision-threatening ocular disease commonly secondary to infectious, inflammatory, and traumatic etiologies. Slit lamp photography, in vivo confocal microscopy, angiography, and optical coherence tomography angiography (OCTA) are the primary diagnostic tools utilized in clinical practice to evaluate the vasculature of the ocular surface. However, there is currently a dearth of comprehensive literature that reviews the advancements in imaging technology for CoNV administration. Initially designed for retinal vascular imaging, OCTA has now been expanded to the anterior segment and has shown promising potential for imaging the conjunctiva, cornea, and iris. This expansion allows for the quantitative monitoring of the structural and functional changes associated with CoNV. In this review, we emphasize the impact of algorithm optimization in anterior segment-optical coherence tomography angiography (AS-OCTA) on the diagnostic efficacy of CoNV. Through the analysis of existing literature, animal model assessments are further reported to investigate its pathological mechanism and exhibit remarkable therapeutic interventions. In conclusion, AS-OCTA holds broad prospects and extensive potential for clinical diagnostics and research applications in CoNV.


Assuntos
Neovascularização da Córnea , Angiofluoresceinografia , Tomografia de Coerência Óptica , Neovascularização da Córnea/diagnóstico , Humanos , Tomografia de Coerência Óptica/métodos , Animais , Angiofluoresceinografia/métodos , Córnea/irrigação sanguínea , Córnea/patologia , Córnea/diagnóstico por imagem , Microscopia Confocal
2.
Ophthalmic Physiol Opt ; 43(4): 885-897, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37073817

RESUMO

PURPOSE: To assess changes in visual function and optical and tear film quality in computer users. METHODS: Forty computer workers and 40 controls were evaluated at the beginning and end of a working day. Symptoms were assessed using the Quality of Vision questionnaire (QoV), 5-item Dry Eye Questionnaire (DEQ-5) and Symptom Assessment in Dry Eye version II (SANDE II). Tear film quality was evaluated using the Medmont E300 dynamic corneal topography tool to measure the tear film surface quality (TFSQ), TFSQ area and auto tear break-up time (TBUT). Optical quality was assessed by measuring high, low and total ocular aberrations with a Hartmann-Shack wavefront sensor. Visual performance was assessed by measuring photopic and mesopic visual acuity, photopic and mesopic contrast sensitivity and light disturbance. RESULTS: Poorer DEQ-5, QoV and SANDE II scores were obtained in computer workers at the end of the working day compared with controls (p ≤ 0.02). Computer workers exhibited a higher (worse) TFSQ and TFSQ area at visit 2 compared with visit 1 (p ≤ 0.04), while no significant differences in TBUT (p = 0.19) or ocular aberrations were observed (p ≥ 0.09). Additionally, both light disturbance (p ≤ 0.04) and mesopic and photopic contrast sensitivity worsened at several spatial frequencies (p ≤ 0.04) throughout the working day in computer workers, while visual acuity remained unchanged (p ≥ 0.07). In contrast, control subjects exhibited no decrease in any variable during the day. CONCLUSIONS: While visual acuity remained unchanged, several aspects of visual function and quality of vision decreased over a day of computer use. These changes were accompanied by greater dry eye symptoms and tear film changes, which are likely to have played a fundamental role. The present study provides insight into new metrics to assess digital eye strain.


Assuntos
Síndromes do Olho Seco , Visão Ocular , Humanos , Lágrimas , Acuidade Visual , Topografia da Córnea , Síndromes do Olho Seco/diagnóstico
3.
Ophthalmic Physiol Opt ; 42(5): 1062-1073, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35801815

RESUMO

PURPOSE: To assess and compare short-term visual and optical quality and tear film stability between two dual-focus (DF) prototype myopia control contact lenses (CLs) having different inner zone diameters. METHODS: Twenty-eight myopic subjects were included in this randomised, double-masked crossover study. Refraction, best-corrected visual acuity (VA) and tear film stability were measured at baseline (i.e., when uncorrected). Subjects were then binocularly fitted with the DF CLs, with only the sensorial dominant eye being assessed. Lenses were of the same material and had inner zone diameters of either 2.1 mm (S design) or 4.0 mm (M design). Visual and physical short-term lens comfort, over-refraction, best-corrected VA, stereopsis at 40 cm, best-corrected photopic and mesopic contrast sensitivity (CS), size and shape of light disturbance (LD), wavefront aberrations, subjective quality of vision (QoV Questionnaire) and tear film stability were measured for each lens. RESULTS: Both CL designs decreased tear film stability compared with baseline (p < 0.05). VA and photopic CS were within normal values for the subjects' age with each CL. When comparing lenses, the M design promoted better photopic CS for the 18 cycles per degree spatial frequency (p < 0.001) and better LD (p < 0.02). However, higher-order aberrations were improved with the S design (p = 0.02). No significant difference between the two CLs was found for QoV scores and tear film stability. CONCLUSIONS: Both DF CLs provided acceptable visual performance under photopic conditions. The 4.0 mm inner zone gave better contrast sensitivity at high frequencies and lower light disturbance, while the 2.1 mm central diameter induced fewer higher-order aberrations for a 5 mm pupil diameter. Both CLs produced the same subjective visual short-term lens comfort.


Assuntos
Lentes de Contato Hidrofílicas , Lentes de Contato , Miopia , Sensibilidades de Contraste , Estudos Cross-Over , Humanos , Miopia/terapia , Refração Ocular , Acuidade Visual
4.
Eye Contact Lens ; 47(8): 480-483, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33928923

RESUMO

ABSTRACT: A 38-year-old woman, previous daily disposable soft contact lens wearer, reported an episode of microbial keratitis positive for Pseudomonas aeruginosa 11 months before contacting the investigators. After acute treatment, she was left with a degree of opacity in the pupillary area, corneal scar, and an irregular corneal profile, with a best spectacle visual acuity of +0.48 logarithm of the minimum angle of resolution. A scleral lens was able to mask those corneal sequelae and, even considering the corneal opacity, the visual acuity recovered to +0.06 logarithm of the minimum angle of resolution. The patient was fitted with a 16.4-mm scleral lens and attended several appointments over a 12-month follow-up period. After 12 months of scleral lens wear, the improvement of both high-contrast and low-contrast visual acuities remained stable and a clearing of the corneal opacity was observed. The comfort was assessed with the Ocular Surface Disease Index questionnaire, which depicted a comfort enhancement from 75.0 to 47.9 over the short term. The Quality of Vision questionnaire was also administrated and showed an improvement on frequency, severity, and bothersome of the vision-related symptoms over time. Scleral lens may be a good option to improve vision, comfort, and restore the ocular surface function in patients with corneal scars and opacities secondary to microbial keratitis.


Assuntos
Lentes de Contato Hidrofílicas , Ceratite , Adulto , Feminino , Humanos , Ceratite/terapia , Esclera , Transtornos da Visão , Acuidade Visual
5.
BMC Ophthalmol ; 20(1): 279, 2020 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-32652982

RESUMO

BACKGROUND: To investigate the biomechanical properties of the cornea in myopic eyes using corneal visualization Scheimpflug technology (Corvis ST). The relationships between the biomechanical properties of the cornea and the degree of myopia were also investigated. METHODS: 265 eyes of 265 subjects were included. Based on spherical equivalent (SE) in diopters (D), participants were divided into four groups: low myopia/control (SE: - 0.50 to - 3.00D), moderate myopia (SE: - 3.00 to - 6.00D), high myopia (SE: - 6.00 to - 10.00D) and severe myopia (SE greater than - 10.00D). Axial length (AL), anterior segment parameters, and corneal biomechanical properties were obtained with the Lenstar LS900, Pentacam HR and Corvis ST, respectively. RESULTS: Mean (±SD) SE was - 7.29 ± 4.31D (range: - 0.63 to - 25.75D). Mean AL was 26.31 ± 1.82 mm (range: 21.87 to 31.94 mm). Significant differences were detected within the four groups in terms of six corneal biomechanical parameters: deformation amplitude (DA), time from start until second applanation (A2-time), length of flattened cornea at the second applanation (A2-length), corneal velocity during the first and second applanation (A2-velocity), time from start to highest concavity (HC-time), and central curvature at highest concavity (HC radius). AL was positively associated with DA whereas negatively associated with A1-velocity and A2-length. SE was positively associated with A2-time, HC-time and A2-velocity, whereas negatively associated with DA. IOP was positively associated with four corneal biomechanical parameters and negatively associated with three parameters. CONCLUSIONS: Eyes with severe myopia showed greater DA, lesser A2 time, HC time, and faster A2-velocity compared to low to high myopia. This suggests the cornea becomes weaker and more deformable with elongation of axial length with corresponding increases in myopia. DA, A2-time and A2-velocity could be useful corneal biomechanical indicators in patients with myopia.


Assuntos
Miopia , Tonometria Ocular , Fenômenos Biomecânicos , Córnea/diagnóstico por imagem , Humanos , Pressão Intraocular
6.
Optom Vis Sci ; 97(9): 775-789, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32941333

RESUMO

SIGNIFICANCE: This study shows the optical and visual quality behavior of modern scleral lenses (SLs) in the medium and long term in patients with irregular cornea (IC) and regular cornea (RC). PURPOSE: The purpose of this study was to evaluate the 12-month optical quality outcomes with SL in patients with IC and RC. METHODS: Sixty-nine patients completed the 12 months of follow-up (99 eyes with IC and 27 with RC). LogMAR high- and low-contrast visual acuity, whole eye aberrometry, and the size (Light Disturbance Index, %) and shape (BFCIrregSD, mm) of night vision disturbances were measured at baseline with habitual correction (HC), best spectacle correction (BSC), and SL at all the follow-up visits (1, 3, 6, and 12 months). Subjective visual quality was measured with the Quality of Vision (QoV) questionnaire. RESULTS: After SL fitting, high-contrast visual acuity improved significantly compared with HC and BSC in the IC group (average improvement of +0.35 ± 0.32 and +0.29 ± 0.26 to +0.08 ± 0.14, P < .001) and RC group (+0.17 ± 0.23 and +0.12 ± 0.23 to +0.10 ± 0.23, P < .05). Light Disturbance Index decreased significantly with SL compared with HC and BSC from 13.85 ± 13.99% and 15.89 ± 13.38% to 5.75 ± 4.51% in the IC group (P < .001) and 6.16 ± 5.38 and 5.98 ± 5.39 to 3.99 ± 3.05 in the RC group (P < .05). BFCIrregSD also decreased significantly, namely, in the IC group (-51%). All subscales of the QoV questionnaire had a statistically significant decrease (improvement) with SL (P < .05). CONCLUSIONS: Scleral lenses promote a better subjective and objective visual quality, mainly in patients with IC. Additional measurements such as night vision disturbances, aberrometry, and subjective perceptions should be considered to characterize the visual enhancement promoted by SL in RC and IC patients.


Assuntos
Lentes de Contato , Aberrações de Frente de Onda da Córnea/terapia , Ceratocone/terapia , Óptica e Fotônica , Esclera , Acuidade Visual/fisiologia , Aberrometria , Adulto , Aberrações de Frente de Onda da Córnea/fisiopatologia , Feminino , Seguimentos , Humanos , Ceratocone/fisiopatologia , Masculino , Pessoa de Meia-Idade , Ajuste de Prótese , Inquéritos e Questionários
7.
Ophthalmic Physiol Opt ; 40(6): 718-727, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32885875

RESUMO

PURPOSE: To compare the optical and visual performance of a dual-focus (DF) contact lens used for myopia control with a single-vision (SV) contact lens of the same material. METHODS: A randomised, double-masked crossover study. Twenty-eight healthy, myopic volunteers between 18 and 32 years of age (23.49 ± 4.07 years) participated in this study. The sensory dominant eye for distance vision was determined. Refraction, best-corrected visual acuity (VA) and aberrations for 3 mm and 5 mm pupil diameters were quantified without a contact lens in situ. Subjects were fitted with two contact lens designs: DF and SV, both made of omafilcon A material. The Quality of Vision (QoV) questionnaire, over-refraction, best-corrected VA, stereopsis at 40 cm, best-corrected photopic and mesopic contrast sensitivity, light disturbance and aberrations were assessed 25 min after contact lens insertion. RESULTS: There were no statistically significant differences in best-corrected VA and stereopsis between the baseline, DF and SV conditions. Photopic and mesopic contrast sensitivity were lower for the DF contact lens at all frequencies, with the exception of the mesopic contrast sensitivity at 18 cycles per degree (p = 0.23). Higher order aberrations and light disturbance size and irregularity were higher for the DF contact lens (p < 0.001). No differences were found in higher order aberrations between baseline and the SV contact lens condition for each pupil diameter. QoV scores also revealed lower frequency, severity and bothersome scores with the SV contact lens than with the DF contact lens (p < 0.001). CONCLUSIONS: The DF contact lens design decreased the psychophysical and psychometric visual quality scores in the short-term under dim-light conditions when compared with a single-vision contact lens design of the same material. VA and stereopsis were unaffected by the lens design.


Assuntos
Visão de Cores/fisiologia , Lentes de Contato Hidrofílicas , Sensibilidades de Contraste/fisiologia , Miopia/fisiopatologia , Acuidade Visual , Adolescente , Adulto , Estudos Cross-Over , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Masculino , Miopia/terapia , Fatores de Tempo , Adulto Jovem
8.
Retina ; 39(9): 1720-1731, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29975344

RESUMO

PURPOSE: To evaluate the clinical effectiveness of intravitreal bevacizumab (IVB) injection combined with cataract surgery in the treatment of patients with cataract and coexisting diabetic retinopathy (DR). METHODS: Pertinent comparative studies were identified through systemic searches of PubMed, EMBASE, and the Cochrane Controlled Trials Register up to March 1, 2016. Outcome measures included corrected distance vision acuity, central macular thickness, and progression of DR and maculopathy. A meta-analysis was performed using RevMan (Cochrane Collaboration, Oxford, United Kingdom). RESULTS: Six studies describing a total of 283 eyes were identified. The meta-analysis results showed that corrected distance vision acuity measured at 1 month and 3 months after cataract surgery was significantly better in the IVB groups than in the control groups (P < 0.00001 and P = 0.01), whereas the corrected distance vision acuity at 6 months did not vary significantly between the 2 groups (P = 0.24). Similarly, the central macular thickness at 1, 3, and 6 months after surgery was significantly thinner in the IVB groups than in the control groups (P = 0.01, P = 0.0004, and P = 0.01, respectively). At 6 months, the progression of postoperative DR and maculopathy occurred more frequently in the control group than in the IVB group (P = 0.0001 and P < 0.0001, respectively). CONCLUSION: Our meta-analysis indicates that cataract surgery combined with IVB seems to be an effective treatment in patients with coexisting DR in the short term (up to 6 months). More randomized, prospective, and large-sample-sized trials are needed to evaluate the long-term effects of IVB at the time of cataract surgery in patients with DR.


Assuntos
Inibidores da Angiogênese/administração & dosagem , Bevacizumab/administração & dosagem , Retinopatia Diabética/tratamento farmacológico , Facoemulsificação/métodos , Idoso , Catarata/complicações , Terapia Combinada , Retinopatia Diabética/complicações , Feminino , Humanos , Injeções Intravítreas , Masculino , Pessoa de Meia-Idade , Ensaios Clínicos Controlados Aleatórios como Assunto , Transtornos da Visão
9.
Eye Contact Lens ; 44(5): 279-285, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29219898

RESUMO

OBJECTIVES: To develop a quality of life (QoL) instrument for patients fitted with Orthokeratology (OrthoK) and other modalities of contact lenses. METHODS: A 45-item pilot questionnaire was developed from an extensive literature review, focus groups, and interviews. Subsequently, 234 participants fitted with contact lenses (OrthoK, soft lenses, and gas permeable lenses) or spectacles completed the pilot questionnaire. Rasch analysis was used to assess the psychometric properties in terms of person separation, item fit statistics, category threshold ordering, differential item functioning (DIF), and targeting. A subset of participants completed the final questionnaire twice (1 week apart) and the repeatability assessed (within-subject standard deviation). The Spearman rank-order correlation coefficient between the questionnaire score and binocular visual acuity was calculated to assess construct validity. RESULTS: Inspection of category probability curves suggested that one category was underused and the response options were collapsed. Furthermore, Rasch analyses indicated 22 items misfitted the model and were removed. The final questionnaire contained 23 items with a person separation of 2.18, item fit statistics within the range 0.83 to 1.15, targeting 1.05 logits, and no significant DIF (<0.8 logits). The repeatability (Sr) was 4.21 and there was no correlation between questionnaire scores and binocular visual acuity (rs=0.03, P=0.65). CONCLUSIONS: The Orthokeratology and Contact Lens Quality of Life Questionnaire demonstrated excellent psychometric properties and is capable of measuring vision-related QoL in patients fitted with various forms of contact lenses including OrthoK lenses. The tool is scored on a 0 to 100 interval level scale with higher scores indicating better QoL.


Assuntos
Lentes de Contato , Procedimentos Ortoceratológicos , Avaliação de Resultados em Cuidados de Saúde/métodos , Qualidade de Vida , Erros de Refração/terapia , Inquéritos e Questionários/normas , Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Psicometria , Erros de Refração/psicologia , Adulto Jovem
10.
Ophthalmology ; 124(9): 1280-1289, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28433446

RESUMO

PURPOSE: To investigate the association between dysphotopsia and neural responses in visual and higher-level cortical regions in patients who recently received multifocal intraocular lens (IOL) implants. DESIGN: Cross-sectional study. PARTICIPANTS: Thirty patients 3 to 4 weeks after bilateral cataract surgery with diffractive IOL implantation and 15 age- and gender-matched control subjects. METHODS: Functional magnetic resonance imaging (fMRI) was performed when participants viewed low-contrast grating stimuli. A light source surrounded the stimuli in half of the runs to induce disability glare. Visual acuity, wavefront analysis, Quality of Vision (QoV) questionnaire, and psychophysical assessment were performed. MAIN OUTCOME MEASURES: Cortical activity (blood oxygen level dependent [BOLD] signal) in the primary visual cortex and in higher-level brain areas, including the attention network. RESULTS: When viewing low-contrast stimuli under glare, patients showed significant activation of the effort-related attention network in the early postoperative period, involving the frontal, middle frontal, parietal frontal, and postcentral gyrus (multisubject random-effects general linear model (GLM), P < 0.03). In contrast, controls showed only relative deactivation (due to lower visibility) of visual areas (occipital lobe and middle occipital gyrus, P < 0.03). Patients also had relatively stronger recruitment of cortical areas involved in learning (anterior cingulate gyrus), task planning, and solving (caudate body). Patients reporting greater symptoms induced by dysphotic symptoms showed significantly increased activity in several regions in frontoparietal circuits, as well as cingulate gyrus and caudate nucleus (q < 0.05). We found no correlation between QoV questionnaire scores and optical properties (total and higher order aberration, modulation transfer function, and Strehl ratio). CONCLUSIONS: This study shows the association between patient-reported subjective difficulties and fMRI outcomes, independent of optical parameters and psychophysical performance. The increased activity of cortical areas dedicated to attention (frontoparietal circuits), to learning and cognitive control (cingulate), and to task goals (caudate) likely represents the beginning of the neuroadaptation process to multifocal IOLs.


Assuntos
Adaptação Psicológica/fisiologia , Ofuscação , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Transtornos da Visão/fisiopatologia , Córtex Visual/fisiologia , Idoso , Sensibilidades de Contraste/fisiologia , Estudos Transversais , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Oxigênio/sangue , Satisfação do Paciente , Estudos Prospectivos , Desenho de Prótese , Pseudofacia/fisiopatologia , Inquéritos e Questionários , Transtornos da Visão/diagnóstico por imagem , Acuidade Visual/fisiologia , Córtex Visual/diagnóstico por imagem
11.
Eye Contact Lens ; 43(1): e1-e3, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26222098

RESUMO

INTRODUCTION: Psoriasis is a common chronic inflammatory skin disease. Ocular manifestations, which occur in 10% to 20% of cases of psoriasis, are usually bilateral and often present during an exacerbation of the psoriasis. Serious corneal involvement is rare but can be devastating. CASE REPORT: Two cases of sterile corneal infiltrates secondary to an exacerbation of psoriasis are presented. Treatment involved the use of 0.02% topical tacrolimus ointment, which resulted in resolution of the symptoms and infiltrates. DISCUSSION AND CONCLUSION: Topical tacrolimus may be considered as an alternative treatment option to corticosteroids in sterile corneal infiltrates.


Assuntos
Doenças da Córnea/tratamento farmacológico , Imunossupressores/uso terapêutico , Psoríase/tratamento farmacológico , Tacrolimo/uso terapêutico , Administração Tópica , Adulto , Doenças da Córnea/etiologia , Humanos , Masculino , Pomadas , Psoríase/complicações
12.
Ophthalmology ; 123(4): 697-708, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26826749

RESUMO

PURPOSE: To determine the effectiveness of different interventions to slow down the progression of myopia in children. METHODS: We searched MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, World Health Organization International Clinical Trials Registry Platform, and ClinicalTrials.gov from inception to August 2014. We selected randomized controlled trials (RCTs) involving interventions for controlling the progression of myopia in children with a treatment duration of at least 1 year for analysis. MAIN OUTCOME MEASURES: The primary outcomes were mean annual change in refraction (diopters/year) and mean annual change in axial length (millimeters/year). RESULTS: Thirty RCTs (involving 5422 eyes) were identified. Network meta-analysis showed that in comparison with placebo or single vision spectacle lenses, high-dose atropine (refraction change: 0.68 [0.52-0.84]; axial length change: -0.21 [-0.28 to -0.16]), moderate-dose atropine (refraction change: 0.53 [0.28-0.77]; axial length change: -0.21 [-0.32 to -0.12]), and low-dose atropine (refraction change: 0.53 [0.21-0.85]; axial length change: -0.15 [-0.25 to -0.05]) markedly slowed myopia progression. Pirenzepine (refraction change: 0.29 [0.05-0.52]; axial length change: -0.09 [-0.17 to -0.01]), orthokeratology (axial length change: -0.15 [-0.22 to -0.08]), and peripheral defocus modifying contact lenses (axial length change: -0.11 [-0.20 to -0.03]) showed moderate effects. Progressive addition spectacle lenses (refraction change: 0.14 [0.02-0.26]; axial length change: -0.04 [-0.09 to -0.01]) showed slight effects. CONCLUSIONS: This network analysis indicates that a range of interventions can significantly reduce myopia progression when compared with single vision spectacle lenses or placebo. In terms of refraction, atropine, pirenzepine, and progressive addition spectacle lenses were effective. In terms of axial length, atropine, orthokeratology, peripheral defocus modifying contact lenses, pirenzepine, and progressive addition spectacle lenses were effective. The most effective interventions were pharmacologic, that is, muscarinic antagonists such as atropine and pirenzepine. Certain specially designed contact lenses, including orthokeratology and peripheral defocus modifying contact lenses, had moderate effects, whereas specially designed spectacle lenses showed minimal effect.


Assuntos
Atropina/administração & dosagem , Óculos , Midriáticos/administração & dosagem , Miopia/prevenção & controle , Comprimento Axial do Olho/fisiologia , Bases de Dados Factuais , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Refração Ocular/fisiologia , Resultado do Tratamento
13.
Graefes Arch Clin Exp Ophthalmol ; 252(3): 509-14, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24158371

RESUMO

BACKGROUND: To compare the accommodative amplitude (AA), facility (AF), and lag between dominant and non-dominant eyes. METHODS: Seventy students [mean (SD) age: 21.2 (1.7) years, range 18-25] from Zahedan University of Medical Sciences were selected. Retinoscopy and subjective refraction was used to determine the refractive error. The hole-in-the card method was used to determine eye dominance. The accommodative amplitude (AA) was measured in the dominant and non-dominant eye using the push-up method, and accommodative facility (AF) using ±2.00 dioptre flipper lenses at 40 cm. Accommodative lag was determined using monocular estimate method (MEM) retinoscopy at 40 cm. RESULTS: The right eye was dominant in 53 subjects (75.7 %). There was no significant difference in refractive error (sphere, cylinder, and spherical equivalent) between dominant and non-dominant eyes. The mean (SD) for the AA, AF, and lag in dominant eyes was 12.48 (2.56) dioptres, 12.45 (4.83) cycles per minute, and 0.80 (0.27) dioptres respectively. The mean (SD) for the AA, AF, and lag in non-dominant eyes was 12.16 (2.37) dioptres, 12.20 (4.88) cycles per minute, and 0.83 (0.28) dioptres respectively. The mean (SD) difference in AA, AF, and lag between dominant and non dominant eyes was 0.32 (0.75) dioptres (P = 0.001), 0.25 (1.05) cycles per minute (P = 0.04), and -0.02 (0.11) dioptres (P = 0.10) respectively. The AA and AF was statistically better (P < 0.05) in the dominant eye group than in the non-dominant eye group. These data provided little evidence of any difference in the accommodative lag between dominant and non-dominant eyes (P > 0.05). CONCLUSION: The right eye was dominant in 76 % of subjects. Superior AA and AF was found in the dominant eye as determined by hole-in-the card method in young healthy adults, although these differences are perhaps not of clinical significance (<0.50 dioptres and <2 cycles per minute).


Assuntos
Acomodação Ocular/fisiologia , Dominância Ocular/fisiologia , Adolescente , Adulto , Estudos Transversais , Feminino , Humanos , Masculino , Estudos Prospectivos , Refração Ocular/fisiologia , Retinoscopia , Acuidade Visual/fisiologia , Adulto Jovem
14.
Eye (Lond) ; 38(4): 668-679, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37875701

RESUMO

The amniotic membrane is a single epithelial layer of the placenta. It has anti-inflammatory, anti-scarring, anti-angiogenic and possibly bactericidal properties. The basement membrane of the amniotic membrane acts as a substrate to encourage healing and re-epithelialisation. It has been used in many ocular surface diseases including persistent epithelial defects (corneal or conjunctival), chemical or thermal burns, limbal stem cell deficiency, cicatrising conjunctivitis, ocular graft versus host disease, microbial keratitis, corneal perforation, bullous keratopathy, dry eye disease, corneal haze following refractive surgery and cross-linking, band keratopathy, ocular surface neoplasia, pterygium surgery, and ligneous conjunctivitis. This review provides an up-to-date overview of amniotic membrane transplantation including the structural and biological properties, preparation and application, clinical indications, and commercially available products.


Assuntos
Conjuntivite , Doenças da Córnea , Distrofias Hereditárias da Córnea , Oftalmopatias , Feminino , Gravidez , Humanos , Âmnio/transplante , Oftalmopatias/cirurgia , Córnea , Doenças da Córnea/cirurgia
15.
Acta Ophthalmol ; 2024 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-38780148

RESUMO

PURPOSE: To manage patient dissatisfaction following multifocal intraocular lens (MF-IOL) implantation by IOL exchange with either a monofocal or an alternative MF-IOL, and to compare outcomes in these two groups. METHODS: MF-IOL exchange was performed in 32 patients (64 eyes) with neuroadaptation failure. The MF-to-MF group involved patients who had a MF-IOL exchanged with another MF-IOL of a different optical profile and the MF-to-MO group involved patients who had a MF-IOL exchanged to a monofocal IOL. Visual outcomes and complications were analysed. The Quality of Vision (QoV) questionnaire, Visual Function Index (VF-14) and its Rasch-revised version (VF-8R) were also used to assess outcomes. RESULTS: There were no significant differences (p > 0.05) in the QoV scores between the two groups, both preoperatively and postoperatively. Preoperatively, there were no significant differences in VF-14 scores between both groups (p > 0.05). Postoperatively, there were statistically significant differences in VF-14 (total score, intermediate vision and near vision) in favour of the MF-to-MF group (p < 0.05). The postoperative VF-8R score in the MF-to-MF group was significantly better than the MF-to-MO group (p ≤ 0.001). Uncorrected and corrected near as well as corrected distance visual acuities were significantly better (p < 0.05) in the MF-to-MF group compared to the MF-to-MO group at 3 months. CONCLUSION: Patient dissatisfaction and neuroadaptation failure following MF-IOL implantation can be managed by an IOL exchange with an alternative optical design of MF-IOL or a monofocal IOL. Although, in the current study, the MF-to-MF group showed some better postoperative results, both options are feasible solutions.

16.
Adv Sci (Weinh) ; 11(25): e2401710, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38582513

RESUMO

Corneal neovascularization (CNV) is a common clinical finding seen in a range of eye diseases. Current therapeutic approaches to treat corneal angiogenesis, in which vascular endothelial growth factor (VEGF) A plays a central role, can cause a variety of adverse side effects. The technology of Clustered Regularly Interspaced Short Palindromic Repeats (CRISPR)/Cas9 can edit VEGFA gene to suppress its expression. CRISPR offers a novel opportunity to treat CNV. This study shows that depletion of VEGFA with a novel CRISPR/Cas9 system inhibits proliferation, migration, and tube formation of human umbilical vein endothelial cells (HUVECs) in vitro. Importantly, subconjunctival injection of this dual AAV-SpCas9/sgRNA-VEGFA system is demonstrated which blocks suture-induced expression of VEGFA, CD31, and α-smooth muscle actin as well as corneal neovascularization in mice. This study has established a strong foundation for the treatment of corneal neovascularization via a gene editing approach for the first time.


Assuntos
Sistemas CRISPR-Cas , Neovascularização da Córnea , Modelos Animais de Doenças , Edição de Genes , Células Endoteliais da Veia Umbilical Humana , Fator A de Crescimento do Endotélio Vascular , Neovascularização da Córnea/genética , Neovascularização da Córnea/terapia , Neovascularização da Córnea/metabolismo , Animais , Edição de Genes/métodos , Camundongos , Fator A de Crescimento do Endotélio Vascular/genética , Fator A de Crescimento do Endotélio Vascular/metabolismo , Humanos , Células Endoteliais da Veia Umbilical Humana/metabolismo , Sistemas CRISPR-Cas/genética , Camundongos Endogâmicos C57BL , Proliferação de Células/genética
17.
Optom Vis Sci ; 90(8): 720-44, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23873034

RESUMO

PURPOSE: The aim of this article was to systematically review all the available ophthalmic patient-reported outcome (PRO) instruments (questionnaires) that demonstrated interval measurement properties to identify the instruments with the highest psychometric quality for use in different eye diseases and conditions. METHODS: An extensive literature review was carried out to identify all existing ophthalmic PRO instruments. Instruments were then excluded if they did not have demonstrable interval measurement properties; the remaining instruments were reviewed. The quality of the following psychometric properties was assessed: content development (initial item development process), performance of the response scale, dimensionality (whether the instrument measures a single construct), measurement precision, validity (convergent, concurrent, discriminant, and known groups), reliability (test-retest), targeting (whether the items are appropriate [e.g., difficulty level] for the population), differential item functioning (whether subgroups of people respond differently to an item), and responsiveness. RESULTS: The search identified 48 PRO instruments that demonstrated interval measurement properties, and these were relevant to nine applications: glaucoma, dry eye, refractive errors, cataract, amblyopia and strabismus, macular diseases, adult low vision, children low vision, and others. These instruments were evaluated against the psychometric property quality criteria and were rated for quality based on the number of criteria met. CONCLUSIONS: This review provides a descriptive catalog of ophthalmic PRO instruments to inform researchers and clinicians on the choice of the highest-quality PRO instrument suitable for their purpose.


Assuntos
Oftalmopatias , Oftalmologia/normas , Avaliação de Resultados em Cuidados de Saúde/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Inquéritos e Questionários/normas , Humanos , Psicometria/instrumentação , Qualidade de Vida , Reprodutibilidade dos Testes , Estudos de Validação como Assunto
18.
Optom Vis Sci ; 90(8): 760-4, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23792364

RESUMO

PURPOSE: The purpose of this study is to evaluate the interchangeability of the three subscales of the Quality of Vision (QoV) questionnaire: Frequency, Severity and Bothersome. This will indicate if any of the subscales are predictive of one another and whether respondents need to complete all three subscales. METHODS: Data from four studies were pooled together, totaling 1930 completed questionnaires. Patient groups consisted of spectacle wearers, contact lens wearers, post-laser refractive surgery (including laser in situ keratomileusis, laser-assisted subepithelial keratectomy, and photorefractive keratectomy surgeries for various refractive errors), patients with cataract, and patients having undergone lens implantation surgery (consisting of monofocal, multifocal, and pseudoaccommodative intraocular lenses). The Bland-Altman limits of agreement (LoA) method was used to assess the interchangeability between the three subscales of the QoV questionnaire. RESULTS: The mean difference, standard deviation of the differences, and the LoA for the Frequency versus Severity subscale was 2.8570, 6.784, and -10.4397 to 16.1537, respectively. The mean difference, standard deviation of the differences, and the LoA for the Frequency versus Bothersome subscale was 5.4674, 12.5768, and -19.1831 to 30.1179, respectively. The mean difference, standard deviation of the differences, and the LoA for the Severity versus Bothersome subscale was 2.6104, 9.4444, and -15.9006 to 21.1213, respectively. CONCLUSIONS: The wide LoA found in this study indicate that the three subscales of the QoV questionnaire (Frequency, Severity and Bothersome.) measure different aspects of the latent trait, quality of vision. Users should continue to use all three subscales of the questionnaire to achieve a comprehensive assessment of subjective quality of vision.


Assuntos
Qualidade de Vida/psicologia , Procedimentos Cirúrgicos Refrativos , Perfil de Impacto da Doença , Inquéritos e Questionários , Adulto , Idoso , Idoso de 80 Anos ou mais , Extração de Catarata , Lentes de Contato , Óculos , Feminino , Humanos , Ceratectomia Subepitelial Assistida por Laser , Ceratomileuse Assistida por Excimer Laser In Situ , Lentes Intraoculares , Masculino , Pessoa de Meia-Idade , Ceratectomia Fotorrefrativa , Visão Ocular/fisiologia , Acuidade Visual/fisiologia , Adulto Jovem
19.
J Clin Med ; 12(3)2023 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-36769412

RESUMO

The aim of this study was to investigate the effects of atropine on patients' perception of visual quality after trabeculectomy. Forty patients undergoing standard trabeculectomy with mitomycin C were enrolled in this prospective randomized study. All surgeries were conducted at the ophthalmology department of the University Medical Center of Mainz, Germany. All patients received the same postoperative treatment with ofloxacin and dexamethasone eye drops. Following randomization of patients into two groups of 20 patients, the intervention group also received atropine eye drops three times daily for the first 2 days after surgery to stabilize the anterior chamber. All patients completed a visual quality questionnaire before surgery and 2 and 6 weeks after surgery. Results were compared using the Wilcoxon test. After surgery, there was a reduction in visual quality in all patients. Patients who received atropine eye drops described a greater and longer-lasting reduction in visual quality than those who did not receive atropine eye drops. Trabeculectomy often leads to a transient reduction in visual quality. This reduction was greater in severity and duration in patients who received postoperative atropine eye drops. Thus, unless there is an underlying medical necessity, we would discourage the application of atropine as a standard therapy for trabeculectomy surgery.

20.
J Refract Surg ; 39(7): 474-480, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37449505

RESUMO

PURPOSE: To assess repeatability and agreement of corneal epithelial thickness mapping in eyes with keratoconus using three optical coherence tomography (OCT) devices featuring different technologies: spectral-domain (SD) OCT combined with Placido disk corneal topography (MS-39), swept-source OCT (Anterion), and SD-OCT (Avanti). METHODS: Three consecutive measurements were acquired with the three devices in 60 eyes with keratoconus. The mean epithelial thickness was calculated in the central 2-mm zone and in 2- to 5-mm and 5- to 7-mm diameter rings. The repeatability was calculated using pooled within-subject standard deviation (Sw). The agreement was assessed by paired t tests and Bland-Altman plots. RESULTS: The repeatability (Sw) of the epithelial thickness for the central 2-mm zone was 0.91, 0.71, and 0.93 µm for the MS-39, Anterion, and Avanti, respectively. All thicknesses with the MS-39 were greater than those of the Anterion and Avanti, with mean differences of 4.11 ± 1.34 µm (P < .001) and 0.52 ± 1.30 µm (P = .003), respectively. The 95% limits of agreement were 1.484 to 6.736 µm for the MS-39 and Anterion, -3.068 to 2.028 µm for the Avanti and MS-39, and 1.258 to 5.922 µm for for the Avanti and Anterion. CONCLUSIONS: Epithelial thickness mapping results were most repeatable with the Anterion, followed by the MS-39 and Avanti. The MS-39 gave the thickest values, followed by the Avanti and Anterion. The differences were significant, making the devices not interchangeable for epithelial thickness mapping in eyes with keratoconus. [J Refract Surg. 2023;39(7):474-480.].


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Tomografia de Coerência Óptica/métodos , Paquimetria Corneana , Reprodutibilidade dos Testes , Córnea , Topografia da Córnea/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA