1.
Lancet Oncol ; 24(5): e207-e218, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37142382

RESUMO

Lung cancer screening with low-dose CT was recommended by the UK National Screening Committee (UKNSC) in September, 2022, on the basis of data from trials showing a reduction in lung cancer mortality. These trials provide sufficient evidence to show clinical efficacy, but further work is needed to prove deliverability in preparation for a national roll-out of the first major targeted screening programme. The UK has been world leading in addressing logistical issues with lung cancer screening through clinical trials, implementation pilots, and the National Health Service (NHS) England Targeted Lung Health Check Programme. In this Policy Review, we describe the consensus reached by a multiprofessional group of experts in lung cancer screening on the key requirements and priorities for effective implementation of a programme. We summarise the output from a round-table meeting of clinicians, behavioural scientists, stakeholder organisations, and representatives from NHS England, the UKNSC, and the four UK nations. This Policy Review will be an important tool in the ongoing expansion and evolution of an already successful programme, and provides a summary of UK expert opinion for consideration by those organising and delivering lung cancer screenings in other countries.


Assuntos
Neoplasias Pulmonares , Medicina Estatal , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Detecção Precoce de Câncer , Inglaterra , Pulmão
2.
Ulster Med J ; 82(2): 75-81, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-24082283

RESUMO

BACKGROUND: PET/CT scanning can determine suitability for curative therapy and inform decision making when considering radical therapy in patients with non-small cell lung cancer (NSCLC). Metastases to central mediastinal lymph nodes (N2) may alter such management decisions. We report a 2 year retrospective series assessing N2 lymph node staging accuracy with PET/CT compared to pathological analysis at surgery. METHODS: Patients with NSCLC attending our centre (excluding those who had induction chemotherapy) who had staging PET/CT scans and pathological nodal sampling between June 2006 and June 2008 were analysed. For each lymph node assessed pathologically, the corresponding PET/CT status was determined. 64 patients with 200 N2 lymph nodes were analysed. RESULTS: Sensitivity of PET/CT scans for indentifying involved N2 lymph nodes was 39%, specificity 96% and overall accuracy 90%. For individual lymph node analysis, logistic regression demonstrated a significant linear association between PET/CT sensitivity and time from scanning to surgery (p=0.031) but not for specificity and accuracy. Those scanned <9 weeks before pathological sampling were significantly more sensitive (64% >9 weeks, 0% ≥ 9 weeks, p=0.013) and more accurate (94% <9 weeks, 81% ≥ 9 weeks, p=0.007). Differences in specificity were not seen (97% <9 weeks, 91% ≥ 9 weeks, p=0.228). No significant difference in specificity was found at any time point. CONCLUSIONS: We recommend that if a PET/CT scan is older than 9 weeks, and management would be altered by the presence of N2 nodes, re-staging of the mediastinum should be undertaken.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/secundário , Neoplasias Pulmonares/patologia , Linfonodos/diagnóstico por imagem , Imagem Multimodal , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Feminino , Fluordesoxiglucose F18 , Humanos , Neoplasias Pulmonares/cirurgia , Linfonodos/patologia , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Fatores de Tempo , Tomografia Computadorizada por Raios X