Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Biol Chem ; 299(8): 105021, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37423299

RESUMO

Recurrent hormone receptor-positive (HR+) breast cancer kills more than 600,000 women annually. Although HR+ breast cancers typically respond well to therapies, approximately 30% of patients relapse. At this stage, the tumors are usually metastatic and incurable. Resistance to therapy, particularly endocrine therapy is typically thought to be tumor intrinsic (e.g., estrogen receptor mutations). However, tumor-extrinsic factors also contribute to resistance. For example, stromal cells, such as cancer-associated fibroblasts (CAFs), residing in the tumor microenvironment, are known to stimulate resistance and disease recurrence. Recurrence in HR+ disease has been difficult to study due to the prolonged clinical course, complex nature of resistance, and lack of appropriate model systems. Existing HR+ models are limited to HR+ cell lines, a few HR+ organoid models, and xenograft models that all lack components of the human stroma. Therefore, there is an urgent need for more clinically relevant models to study the complex nature of recurrent HR+ breast cancer, and the factors contributing to treatment relapse. Here, we present an optimized protocol that allows a high take-rate, and simultaneous propagation of patient-derived organoids (PDOs) and matching CAFs, from primary and metastatic HR+ breast cancers. Our protocol allows for long-term culturing of HR+ PDOs that retain estrogen receptor expression and show responsiveness to hormone therapy. We further show the functional utility of this system by identifying CAF-secreted cytokines, such as growth-regulated oncogene α , as stroma-derived resistance drivers to endocrine therapy in HR+ PDOs.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/genética , Neoplasias da Mama/patologia , Receptores de Estrogênio/genética , Receptores de Estrogênio/metabolismo , Recidiva Local de Neoplasia/patologia , Fibroblastos/metabolismo , Organoides/metabolismo , Microambiente Tumoral
2.
Radiology ; 309(2): e230530, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37962503

RESUMO

Background Despite growing interest in using contrast-enhanced mammography (CEM) for breast cancer screening as an alternative to breast MRI, limited literature is available. Purpose To determine whether CEM is noninferior to breast MRI or abbreviated breast MRI (AB MRI) and superior to two-dimensional mammography in an asymptomatic population simulating those who would present for screening and then undergo diagnostic work-up. Materials and Methods This enriched reader study used CEM and MRI data prospectively collected from asymptomatic individuals at a single institution from December 2014 to March 2020. Case sets were obtained at screening, as part of work-up for a screening-detected finding, or before biopsy of a screening-detected abnormality. All images were anonymized and randomized, and all 12 radiologists interpreted them. For CEM interpretation, readers were first shown low-energy images as a surrogate for digital mammography and asked to give a forced Breast Imaging Reporting and Data System score for up to three abnormalities. The highest score was used as the case score. Readers then reviewed the full CEM examination and scored it similarly. After a minimum 1-month washout, the readers similarly interpreted AB MRI and full MRI examinations. Receiver operating characteristic analysis, powered to test CEM noninferiority to full MRI, was performed. Results The study included 132 case sets (14 negative, 74 benign, and 44 malignant; all female participants; mean age, 54 years ± 12 [SD]). The mean areas under the receiver operating characteristic curve (AUCs) for digital mammography, CEM, AB MRI, and full MRI were 0.79, 0.91, 0.89, and 0.91, respectively. CEM was superior to digital mammography (P < .001). No evidence of a difference in AUC was found between CEM and AB MRI and MRI. Conclusion In an asymptomatic study sample, CEM was noninferior to full MRI and AB MRI and was superior to digital mammography. Clinical trial registration no. NCT03482557 and NCT02275871 © RSNA, 2023 Supplemental material is available for this article.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Pessoa de Meia-Idade , Área Sob a Curva , Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética , Mamografia , Exame Físico
3.
Radiology ; 305(2): 299-306, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35819328

RESUMO

Background Despite the increasing use of contrast-enhanced mammography (CEM), there are limited data on the evaluation of findings on recombined images and the association with malignancy. Purpose To determine the rates of malignancy of enhancement findings on CEM images in the presence or absence of low-energy findings using the Breast Imaging Reporting and Data System (BI-RADS) lexicon developed for mammography and MRI. Materials and Methods All diagnostic CEM examinations performed at one academic institution between December 2015 and December 2019 had low-energy and recombined images retrospectively. Data were independently reviewed by three breast imaging radiologists with 5-25 years of experience using the BI-RADS mammography and MRI lexicon. Outcome was determined with pathologic analysis or 1-year imaging or clinical follow-up. The χ2 and Fisher exact tests were used for analysis. Results A total of 371 diagnostic CEM studies were performed in 371 women (mean age, 54 years ± 11[SD]). Sensitivity, specificity, positive predictive value (PPV), and negative predictive value of enhancement on CEM images was 95% (104 of 109 [95% CI: 90, 98]), 67% (176 of 262 [95% CI: 61, 73]), 55% (104 of 190 [95% CI: 47, 62]), and 97% (176 of 181 [95% CI: 94, 99]), respectively. Among 190 CEM studies with enhancing findings, enhancing lesions were more likely to be malignant when associated with low-energy findings (26% vs 59%, P < .001). Among enhancement types, mass enhancement composed 71% (99 of 140) of all malignancies with PPV of 63% when associated with low-energy findings. Foci, non-mass enhancement, and mass enhancement without low-energy findings had PPV of 6%, 24%, and 38%, respectively. Neither background parenchymal enhancement nor density was associated with enhancement type (P = .19 and P = .28, respectively). Conclusion Mass enhancement on recombined images using CEM was most commonly associated with malignancy, especially when associated with low-energy findings. Enhancement types were more likely to be benign when not associated with low-energy findings; however, they should still be viewed with suspicion, given the high association with malignancy. © RSNA, 2022 Online supplemental material is available for this article.


Assuntos
Neoplasias da Mama , Neoplasias , Humanos , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Mamografia/métodos , Imageamento por Ressonância Magnética/métodos , Valor Preditivo dos Testes , Neoplasias da Mama/diagnóstico por imagem
4.
Radiology ; 310(1): e240014, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38259211
5.
AJR Am J Roentgenol ; 212(1): 222-231, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30383409

RESUMO

OBJECTIVE: The purpose of this article is to discuss the essential steps involved in performing, interpreting, managing, and reporting findings on contrast-enhanced mammography for successful implementation into clinical practice. CONCLUSION: To successfully implement contrast-enhanced mammography into clinical practice, an understanding about the acquisition of images, image interpretation, and reporting of the spectrum of negative, benign, and malignant findings is essential.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Meios de Contraste , Mamografia/métodos , Diagnóstico Diferencial , Feminino , Humanos , Intensificação de Imagem Radiográfica
6.
Radiographics ; 39(7): 1907-1920, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31697627

RESUMO

Contrast-enhanced mammography (CEM) is a developing modality used for the workup and management of breast cancer. Although diagnostic imaging modalities such as mammography and US have historically been the mainstays of initial breast cancer workup, recent advances in breast MRI have allowed better disease evaluation. However, MRI is not always readily available, can be time consuming, and is contraindicated in certain patients. CEM is an alternative to US and MRI, and it can be used to obtain contrast material-enhanced information and standard mammograms simultaneously. A CEM examination is shorter than that of MRI, and the modalities have similar rates of sensitivity to detect lesions. CEM also costs less than MRI. The authors evaluate clinical uses of CEM and discuss the literature supporting these indications.©RSNA, 2019.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Meios de Contraste , Mamografia/métodos , Idoso , Antineoplásicos/farmacologia , Antineoplásicos/uso terapêutico , Mama/efeitos dos fármacos , Doenças Mamárias/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Calcinose/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico por imagem , Diagnóstico Diferencial , Detecção Precoce de Câncer , Feminino , Previsões , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Terapia Neoadjuvante , Ultrassonografia Mamária/métodos
7.
Breast J ; 25(2): 262-268, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30746809

RESUMO

The purpose of this study was to evaluate providers' ordering practices and perceptions of breast magnetic resonance imaging (MRI) in an academic network in order to better understand and educate a referral base. An online survey was distributed to primary care providers (PCPs) and specialists in our hospital and community practices. Questions included provider demographics, current ordering practices, challenges to ordering, and perceptions about breast MRI. Of 525 ordering providers, 134 responded (26% response rate). Of 134 providers, 57 (42%) order breast MRI in practice. Of those who do not, the most consistent reason was a lack of familiarity with the use of breast MRI (32/77 [42%] of cases). Of 57 cases, 45 (79%) order less than 10 exams annually. The most frequent indication is for high-risk screening (40/47 [84%]). PCPs order fewer breast MRI compared with specialists (P = 0.01). Both PCPs and specialists have mixed perceptions of the clinical utility of breast MRI. However, 30% of all providers are ordering more breast MRI since the enactment of breast density legislation in Massachusetts. Furthermore, 29% report they would order breast MRI more often to screen women with dense breasts if there was a low cost option. Referring provider surveys are useful tools for assessing a radiology practice. Our study suggests a growing clinical interest in breast MRI for screening; however, there is a need for provider education on the clinical utility of breast MRI. Increasing the radiologist's role in targeted educational interventions may help improve awareness and lead to more appropriate utilization of resources.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Densidade da Mama , Feminino , Humanos , Cobertura do Seguro , Massachusetts , Médicos de Atenção Primária
8.
Breast J ; 25(4): 604-611, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31206889

RESUMO

The purpose is to determine whether an abbreviated MRI protocol (ABMR) is ready to be used for breast cancer screening in an academic practice setting. Two hundred and fifty nine breast MRIs from 1/1/2012 to 6/30/2012 were retrospectively reviewed using ABMR (MIP, Pre-contrastT1, single dynamic post-contrastT1, and subtraction). Five breast radiologists (4-28 year-expr) participated in this reader study performed in two phases: Phase1 - radiologist's privy to clinical history but not to comparison imaging. Phase2 - radiologists provided comparison imaging. For phase1, studies were reviewed using three steps: (a) MIP only (positive/negative/intermediate); (b) ABMR (recall/no recall) and (c) With T2 (for changes in recommendations). Radiologist also recorded total time for interpretation. In Phase2 the MRIs coded as "recall" were re-reviewed with available comparison studies, noting changes in final recommendation. The abnormal interpretation rates (AIRs) were calculated for phase1 and phase2 results with comparison to the original full protocol. Of the 259 patients (avg. age-52 years; range 26-78), there were seven cancers (three invasive, three DCIS and one breast lymphoma). Acquisition time for ABMR was 3 minutes, ABMR + T2-8 minutes, and original full protocol 16 minutes. Average MIP was positive or indeterminate in 86% (6/7) and negative in 14% (1/7) cancers. The average AIR for MIP only was 20.8% (sens-77.1%; spec-80.8%. The AIR w/o comparisons was 25.6% (sens-91.4%; spec- 76.2%); however the average AIR decreased in phase 2 with comparisons to 13.7% (sens-91.4%; spec-88.5%). The AIR of the original full protocol read was 16.2% (sens-100%; spec-85.7%). Addition of T2 changed assessment in only 3% (1.2%-6.5%). Avg. read time for ABMR including T2 was 2.5 minutes (1.6-4.0 minutes). ABMR is reliable for breast cancer screening, with acceptable interpretation time and acceptable AIR.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Centros Médicos Acadêmicos , Adulto , Idoso , Neoplasias da Mama/patologia , Neoplasias da Mama/prevenção & controle , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/prevenção & controle , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Programas de Rastreamento , Pessoa de Meia-Idade , Radiologistas , Sensibilidade e Especificidade , Fatores de Tempo
10.
Radiographics ; 38(6): 1651-1664, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30303794

RESUMO

Physician wellness is recognized as a critical component of enhancing the quality of health care. An epidemic of symptoms related to stress and burnout among medical professionals, including radiologists, in the workplace is threatening not only health care providers at a personal level but also the entire health care system. In this review, the authors highlight recognized stressors in the contemporary radiology workplace and offer practical suggestions for mitigating burnout, improving professional engagement, and promoting wellness. Thematic goals to focus on include fostering an integrated and harmonious community at work, diminishing workplace detractors, creating opportunities to cultivate positive attitudes and intellect, and implementing effective leadership practices. ©RSNA, 2018.


Assuntos
Esgotamento Profissional/prevenção & controle , Promoção da Saúde , Satisfação no Emprego , Radiologistas/psicologia , Humanos , Liderança , Cultura Organizacional
11.
Breast J ; 24(3): 319-324, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28833841

RESUMO

Performance benchmarks exist for mammography (MG); however, performance benchmarks for magnetic resonance imaging (MRI) are not yet fully developed. The purpose of our study was to perform an MRI audit based on established MG and screening MRI benchmarks and to review whether these benchmarks can be applied to an MRI practice. An IRB approved retrospective review of breast MRIs was performed at our center from 1/1/2011 through 12/31/13. For patients with biopsy recommendation, core biopsy and surgical pathology results were reviewed. The data were used to derive mean performance parameter values, including abnormal interpretation rate (AIR), positive predictive value (PPV), cancer detection rate (CDR), percentage of minimal cancers and axillary node negative cancers and compared with MG and screening MRI benchmarks. MRIs were also divided by screening and diagnostic indications to assess for differences in performance benchmarks amongst these two groups. Of the 2455 MRIs performed over 3-years, 1563 were performed for screening indications and 892 for diagnostic indications. With the exception of PPV2 for screening breast MRIs from 2011 to 2013, PPVs were met for our screening and diagnostic populations when compared to the MRI screening benchmarks established by the Breast Imaging Reporting and Data System (BI-RADS) 5 Atlas® . AIR and CDR were lower for screening indications as compared to diagnostic indications. New MRI screening benchmarks can be used for screening MRI audits while the American College of Radiology (ACR) desirable goals for diagnostic MG can be used for diagnostic MRI audits. Our study corroborates established findings regarding differences in AIR and CDR amongst screening versus diagnostic indications.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética/normas , Benchmarking , Biópsia/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Mamografia , Programas de Rastreamento/estatística & dados numéricos , Estudos Retrospectivos
12.
Breast J ; 24(2): 115-119, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28833923

RESUMO

Atypical ductal hyperplasia (ADH), atypical lobular hyperplasia (ALH), and lobular carcinoma in situ (LCIS) are commonly seen on breast core needle biopsy (CNB). Many institutions recommend excision of these lesions to exclude malignancy. A retrospective chart review was performed on patients who had ADH, ALH, or LCIS on breast CNB from 1/1/08 to 12/31/10 who subsequently had surgical excision of the biopsy site. Study objectives included determining upgrade to malignancy at surgical excision, identification of predictors of upgrade, and validation of a recently published predictive model. Clinical and demographic factors, pathology, characteristics of the biopsy procedure and visible residual lesion were recorded. T test and chi-squared test were used to identify predictors. Classification tree was used to predict upgrade. 151 patients had mean age of 53 years. The mean maximum lesion size on imaging was 11 mm. The primary atypia was ADH in 63.6%, ALH in 27.8%, and LCIS in 8.6%. 16.6% of patients had upgrade to malignancy, with 72% DCIS and 28% invasive carcinoma. Risk factors for upgrade included maximum lesion size (P = .002) and radiographic presence of residual lesion (P = .001). A predictive model based on these factors had sensitivity 78%, specificity 80% and AUC = 0.88. Validating a published nomogram with our data produced accuracy figures (AUC = 0.65) within published CI of 0.63-0.82. In CNB specimens containing ADH, ALH, or LCIS, initial lesion size and presence of residual lesion are predictors of upgrade to malignancy. A validated model may be helpful in developing patient management strategies.


Assuntos
Neoplasias da Mama/patologia , Carcinoma Intraductal não Infiltrante/patologia , Lesões Pré-Cancerosas/patologia , Valor Preditivo dos Testes , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia com Agulha de Grande Calibre , Feminino , Humanos , Hiperplasia/patologia , Pessoa de Meia-Idade , Estudos Retrospectivos
13.
AJR Am J Roentgenol ; 209(4): 935-942, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28777649

RESUMO

OBJECTIVE: The purpose of this study was to determine whether mammography adds clinical value in the diagnostic imaging workup of women 30 years old and older who present with palpable breast lumps. MATERIALS AND METHODS: We retrospectively identified the records of all women 30 years old and older who underwent imaging evaluation with mammography and ultrasound for a palpable lump between January 1, 2009, and December 31, 2010. Imaging reports were reviewed for findings related to the lump and for incidental nonpalpable findings. Benign versus malignant outcomes were determined by pathologic analysis or 24-month imaging or clinical follow-up. The contribution of mammography to final diagnosis was assessed on the basis of objective criteria to determine the clinical impact of mammographic findings. RESULTS: The study cohort included 861 patients presenting with 935 palpable lumps. Imaging correlates were reported for 568 of 935 (60.7%) lumps, and imaging findings were negative in 367 of 935 (39.3%). Of the 935 palpable lumps, 858 (91.8%) were benign and 77 (8.2%) were malignant. Mammography added clinical value in the evaluation of 27 of 77 (35.0%) malignant lumps by better delineating extent of disease and in the evaluation of 26 of 858 benign lumps (3.0%) by confirming benignity. Fifty-two of 861 (6.0%) patients had incidental findings that led to a recommendation for biopsy. Twenty-nine of the 52 findings were originally seen with mammography and 23 with ultrasound. Mammography also depicted seven incidental malignancies in nonpalpable areas, and ultrasound depicted one incidental malignancy. CONCLUSION: Adjunct mammography is warranted for evaluation of palpable breast lumps in women 30 years old and older because of the value added to clinical management. In all age cohorts, mammography contributed to delineation of disease extent, detection of incidental malignancies, and confirmation of benign diagnoses.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Mama/patologia , Mamografia , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
14.
AJR Am J Roentgenol ; 209(2): 454-464, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28537752

RESUMO

OBJECTIVE: The purpose of our study is to review the clinical presentation, multimodality appearance, and management of the most common benign and malignant spindle cell lesions of the breast. CONCLUSION: Spindle cell lesions of the breast exhibit characteristic features at mammography, ultrasound, and MRI. Although a definitive diagnosis of these lesions cannot be made with diagnostic imaging alone, knowledge of their characteristic imaging features can assist in refining the differential diagnosis and guiding appropriate management.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Carcinoma/diagnóstico por imagem , Carcinoma/patologia , Imagem Multimodal , Diagnóstico Diferencial , Feminino , Humanos
15.
Radiology ; 280(2): 370-8, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26937802

RESUMO

Purpose To review mammographic, ultrasonographic (US), and magnetic resonance (MR) imaging features and pathologic characteristics of estrogen receptor (ER)-positive, lymph node-negative invasive breast cancer and to determine the relationship of these characteristics to Oncotype DX (Genomic Health, Redwood City, Calif) test recurrence scores (ODRS) for breast cancer recurrence. Materials and Methods This institutional review board-approved retrospective study was performed in a single large academic medical center. The study population included patients with ER-positive, lymph node-negative invasive breast cancer who underwent genomic testing from January 1, 2009, to December 31, 2013. Imaging features of the tumor were classified according to the Breast Imaging Reporting and Data System lexicon by breast imagers who were blinded to the ODRS. Mammography was performed in 86% of patients, US was performed in 84%, and MR imaging was performed in 33%, including morphologic and kinetic evaluation. Images from each imaging modality were evaluated. Each imaging finding, progesterone receptor (PR) and human epidermal growth factor receptor 2 (HER2) status, and tumor grade were then individually correlated with ODRS. Analysis of variance was used to determine differences for each imaging feature. Regression analysis was used to calculate prediction of recurrence on the basis of imaging features combined with histopathologic features. Results The 319 patients had a mean age ± standard deviation of 55 years ± 8.7 (range, 31-82 years). Imaging features with a positive correlation with ODRS included a well-circumscribed oval mass (P = .024) at mammography, vascularity (P = .047) and posterior enhancement (P = .004) at US, and lobulated mass (P = .002) at MR imaging. Recurrence scores were predicted by using these features in combination with PR and HER2 status and tumor grade by using the threshold of more than 30 as a high recurrence score. With a regression tree, there was correlation (r = 0.79) with 89% sensitivity and 83% specificity. Conclusion On the basis of preliminary data, information obtained routinely for breast cancer diagnosis can reliably be used to predict the ODRS with high sensitivity and specificity. (©) RSNA, 2016.


Assuntos
Neoplasias da Mama/diagnóstico , Perfilação da Expressão Gênica/métodos , Perfilação da Expressão Gênica/estatística & dados numéricos , Mamografia/estatística & dados numéricos , Recidiva Local de Neoplasia/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/genética , Feminino , Humanos , Linfonodos , Mamografia/métodos , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/genética , Receptores de Estrogênio , Reprodutibilidade dos Testes , Estudos Retrospectivos
16.
Radiology ; 278(3): 698-706, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26458206

RESUMO

PURPOSE: To compare the recall and cancer detection rates (CDRs) at screening with digital breast tomosynthesis (DBT) with those at screening with two-dimensional (2D) mammography and to evaluate variations in the recall rate (RR) according to patient age, risk factors, and breast density and among individual radiologists at a single U.S. academic medical center. MATERIALS AND METHODS: This institutional review board-approved, HIPAA-compliant prospective study with a retrospective cohort included 85 852 asymptomatic women who presented for breast cancer screening over a 3-year period beginning in 2011. A DBT unit was introduced into the existing 2D mammography screening program, and patients were assigned to the first available machine. Ten breast-subspecialized radiologists interpreted approximately 90% of the examinations. RRs were calculated overall and according to patient age, breast density, and individual radiologist. CDRs were calculated. Single and multiple mixed-effect logistic regression analyses, χ(2) tests, and Bonferroni correction were utilized, as appropriate. RESULTS: The study included 5703 (6.6%) DBT examinations and 80 149 (93.4%) 2D mammography examinations. The DBT subgroup contained a higher proportion of patients with risk factors for breast cancer and baseline examinations. DBT was used to detect 54.3% more carcinomas (+1.9 per 1000, P < .0018) than 2D mammography. The RR was 7.51% for 2D mammography and 6.10% for DBT (absolute change, 1.41%; relative change, -18.8%; P < .0001). The DBT subgroup demonstrated a significantly lower RR for patients with extremely or heterogeneously dense breasts and for patients in their 5th and 7th decades. CONCLUSION: Implementing DBT into a U.S. breast cancer screening program significantly decreased the screening RR overall and for certain patient subgroups, while significantly increasing the CDR. These findings may encourage more widespread adoption and reimbursement of DBT and facilitate improved patient selection.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Continuidade da Assistência ao Paciente , Imageamento Tridimensional , Mamografia/métodos , Programas de Rastreamento/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos
17.
Can Assoc Radiol J ; 67(2): 122-9, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26632099

RESUMO

PURPOSE: It is well known that radiologic-pathologic correlation is critical in managing patients with breast disease. Although regular multidisciplinary conferences addressing radiologic-pathologic correlation are common at most major academic institutions, this approach is not universal in community-based settings or even some of the smaller academic practices. This study was performed to assess the impact of a weekly multidisciplinary conference on patient care to determine whether all breast practices should adopt this approach as a means to streamline and improve the quality of patient care. METHODS: We reviewed cases of percutaneous breast core biopsies presented at our weekly breast radiology-pathology correlation conference from July 1, 2008, to June 30, 2012. Each reviewed case was assigned to 1 of 4 categories (concordant → concordant, concordant → discordant, discordant → discordant, and discordant → concordant) based on the "initial" and "final" impressions of concordance between radiology and pathology. Changes in concordance, histopathological diagnosis, or management that occurred during the conference were recorded prospectively and analysed. Changes in management that were considered significant included changes in recommendations for surgery, repeat core biopsy, or follow-up imaging. RESULTS: Of 1387 presented at the conference, 1313 (94.7%) had no change during the meeting, confirming 1279 (92.2%) concordant and 34 (2.4%) discordant cases. A total of 74 (5.3%) cases had a change during the conference: 22 of 74 (29.7%) were changed from discordant to concordant, avoiding surgical excision in 15 and short interval imaging in 7; 23 of 74 (31.1%) were changed from concordant to discordant; on excision 3 were cancer, 3 atypia, 10 benign, 2 stable on follow-up imaging, and 5 lost to follow-up; the remaining 29 of 74 (39.2%) stayed concordant after review, but had a change in management, avoiding surgery in 14 and short interval imaging in 15. Overall, as a result of this conference, repeat biopsy or excision was recommended in 23, surgery was avoided in 29, short interval imaging avoided in 22, and cancer detected in 3 cases. CONCLUSIONS: Our weekly breast radiology-pathology correlation conference impacted patient management in up to 5.3% of cases. These results support the need to incorporate a weekly multidisciplinary case review of breast core biopsies into all breast care practices. Such a conference maximizes cancer detection, identifies discordant cases in a timely manner, decreases follow-up imaging, and avoids unnecessary surgical intervention.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Doenças Mamárias/patologia , Comunicação Interdisciplinar , Mamografia , Equipe de Assistência ao Paciente/estatística & dados numéricos , Qualidade da Assistência à Saúde/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Biópsia , Feminino , Humanos , Pessoa de Meia-Idade , Assistência ao Paciente
18.
AJR Am J Roentgenol ; 204(1): 204-10, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25539258

RESUMO

OBJECTIVE: The purpose of this study was to determine the frequencies of atypia and cancer at excisional biopsy of lesions with a diagnosis of mucocele-like lesion (MLL) at percutaneous breast biopsy. MATERIALS AND METHODS: Retrospective review of 9286 lesions subjected to percutaneous imaging-guided biopsy identified MLLs in 35 (0.38%) patients. Medical records, imaging studies, and histologic results were reviewed. RESULTS: Of the 35 patients with core biopsy findings of MLL, 27 underwent stereotactic core needle biopsy (19 with microcalcifications, five with calcifications with an associated mass, and three with only a mass), and eight underwent ultrasound-guided core needle biopsy (four with a solid mass, three with a complex cystic mass). At core biopsy, 12 of 35 (34%) MLLs were associated with atypia (10 cases of atypical ductal hyperplasia, two of flat epithelial atypia), and 23 of 35 (66%) were benign MLL only. All 12 MLLs associated with atypia and 12 of 23 benign MLLs were surgically excised. Eleven patients did not undergo surgery, five of whom were lost to follow-up. One of the 12 (3% of the 35) MLLs associated with atypia was upgraded to DCIS. None were upgraded to invasive cancer. None of the benign MLLs were upgraded to malignancy, and findings at excision of four of the 23 (17%) benign MLLs led to a change in diagnosis to a high-risk lesion (three atypical ductal hyperplasia, one atypical lobular hyperplasia). CONCLUSION: MLL is a rare diagnosis but is encountered in large-volume breast practices. The findings are nonspecific with a range of imaging appearances. No imaging test is reliable for differentiating MLL from other suspicious lesions or lesions with associated atypia. Surgery is clearly warranted for MLL associated with atypia at core needle biopsy because it may be upgraded to malignancy upon excision. However, if the presence of atypia at excision of benign MLL will change clinical management, then benign MLL at core needle biopsy warrants surgical excision in some cases. In patients whose treatment will not change if atypia is found at excision, close surveillance with short-interval follow-up is a reasonable alternative.


Assuntos
Neoplasias da Mama/epidemiologia , Neoplasias da Mama/patologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/estatística & dados numéricos , Mucocele/epidemiologia , Mucocele/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Boston/epidemiologia , Feminino , Humanos , Mastectomia/estatística & dados numéricos , Pessoa de Meia-Idade , Prevalência , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Adulto Jovem
19.
AJR Am J Roentgenol ; 204(1): 219-27, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25539260

RESUMO

OBJECTIVE: The purpose of this article is to review the varied appearances and associated diagnoses of nonmass enhancement on breast MRI with radiologic-pathologic correlation. CONCLUSION: Knowledge of the distribution and internal characteristics of these findings is helpful to determine when core needle biopsy is indicated. Correlating imaging with pathologic findings is critical in making appropriate recommendations regarding clinical management.


Assuntos
Algoritmos , Neoplasias da Mama/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto
20.
Radiographics ; 35(1): 239-53, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25590401

RESUMO

Current comprehensive health care reform in the United States demands that policy makers, insurers, providers, and patients work in reshaping the health care system to deliver care that is both more affordable and of higher quality. A tectonic shift is under way that runs contrary to the traditional goal of radiology groups to perform and interpret large numbers of imaging examinations. In fact, radiology service requisitions now must be evaluated for their appropriateness, possibly resulting in a reduction in the number of imaging studies performed. To be successful, radiology groups will have to restructure their business practices and strategies to align with the emerging health care paradigm. This article outlines a four-stage strategic framework that has aided corporations in achieving their goals and that can be readily adapted and applied by radiologists. The four stages are (a) definition and articulation of a purpose, (b) clear definition of strategic goals, (c) prioritization of specific strategic enablers, and (d) implementation of processes for tracking progress and enabling continuous adaptation. The authors provide practical guidance for applying specific tools such as analyses of strengths, weaknesses, opportunities, and threats (so-called SWOT analyses), prioritization matrices, and balanced scorecards to accomplish each stage. By adopting and applying these tools within the strategic framework outlined, radiology groups can position themselves to succeed in the evolving health care environment.


Assuntos
Reforma dos Serviços de Saúde , Administração da Prática Médica/organização & administração , Radiologia/organização & administração , Humanos , Modelos Organizacionais , Objetivos Organizacionais , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA