Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 107
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38753112

RESUMO

Implant-related infections may need suppressive antibiotic therapy (SAT). We describe a SAT strategy using dalbavancin with therapeutic drug monitoring (TDM). This is a retrospective bicentric study of patients with implant-related infection who received dalbavancin SAT between January 2021 and September 2023. Fifteen patients were included. Median number of injections was 4 (IQR: 2-7). Median time between two reinjections was 57 days (IQR 28-82). Dalbavancin plasma concentrations were above 4 mg/L for 97.9% of dosages (93/95) and above 8 mg/L for 85% (81/95). These results support the use of dalbavancin SAT for implant-related infections.

2.
Int Orthop ; 46(5): 989-997, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35113185

RESUMO

INTRODUCTION: Total hip arthroplasty (THA) in young adults, especially in those with hip dysplasia, is affected by wear and acetabular fixation problems. Shelf acetabuloplasty is performed to delay THA in patients with acetabular dysplasia. Thus, we conducted a retrospective, continuous case-control study at a single healthcare facility to analyze (1) the influence of prior shelf acetabuloplasty on the survival of a subsequent THA and (2) the functional outcomes. MATERIALS AND METHODS: We evaluated 105 patients (124 THA) who underwent THA due to hip dysplasia: 54 patients (61 THA) were included in the THA post-shelf acetabuloplasty group (case group) and 51 patients (63 THA) in the THA for dysplasia group (control group). RESULTS: At 15 years' follow-up, 89% of patients (95% CI: 84-91%) in the shelf group and 83% (95% CI: 81-90%) in the dysplasia group had not undergone surgical revision. This difference between groups was not statistically significant (p = 0.566). The functional outcomes were satisfactory in both groups; however, they were significantly better in the dysplasia group than in the shelf group based on the Merle d'Aubigne and Postel score (16.9 vs 16.0 min-max: 14-18 vs 3-18) (p = 0.01), Harris Hip score (90.0 vs 84.7, min-max: 62-100 vs 22-100) (p = 0.017), and the Oxford-12 (18/60 vs 21/60, min-max: 45-12 vs 51-12) (p = 0.04). CONCLUSION: Shelf acetabuloplasty before THA does not negatively affect THA survivorship. The functional outcomes appear to be better in the hips that did not undergo shelf acetabuloplasty, although the results were good in both groups.


Assuntos
Acetabuloplastia , Artroplastia de Quadril , Luxação Congênita de Quadril , Luxação do Quadril , Artroplastia de Quadril/efeitos adversos , Estudos de Casos e Controles , Seguimentos , Luxação do Quadril/cirurgia , Luxação Congênita de Quadril/cirurgia , Articulação do Quadril/cirurgia , Humanos , Reoperação , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
3.
Int Orthop ; 46(12): 2799-2806, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35960343

RESUMO

INTRODUCTION: The management of prosthetic joint infection (PJI) has been widely studied in the context of total hip arthroplasty (THA). However, the outcomes of debridement, antibiotics and implant retention (DAIR) for PJI have never been compared between hip resurfacing arthroplasty (HRA) and THA. This led us to carry out a retrospective case-control study comparing the surgical treatment of post-operative infections between HRA and THA to determine the infection remission rate and the medium-term functional outcomes. METHODS: This single-centre case-control study analysed 3056 HRA cases of which 13 patients had a PJI treated by DAIR. These patients were age-matched with 15 infected THA hips treated by DAIR and modular component exchange (controls). Their survival (no recurrence of the infection) was compared and factors that could affect the success of the DAIR were explored: sex, body mass index, age at surgery, presence of haematoma, type of bacteria present and antibiotic therapy. RESULTS: At a mean follow-up of five years (2-7), the infection control rate was significantly higher in the HRA group (100% [13/13]) than in the THA group (67% [10/15]) (p = 0.044). More patients in the THA group had undergone early DAIR (< 30 days) (73% [11/15]) than in the HRA group (54% [7/13]). There was no significant difference between the two groups in the ASA score, presence of comorbidities, body mass index and duration of the initial arthroplasty procedure. At the review, the Oxford-12 score of 17/60 (12-28) was better in the HRA group than the score of 25/60 (12-40) in the THA group (p = 0.004). CONCLUSION: DAIR, no matter the time frame, is a viable therapeutic option for infection control after HRA.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Antibacterianos/uso terapêutico , Estudos de Casos e Controles , Desbridamento , Estudos Retrospectivos
4.
J Antimicrob Chemother ; 76(11): 3033-3036, 2021 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-34406411

RESUMO

BACKGROUND: The optimal length of the intravenous antibiotic treatment of periprosthetic joint infections (PJIs) generally ranges from one to six weeks and is a matter of debate. Most antibiotics active against Gram-positive cocci (GPC) exhibit both high oral bioavailability and bone diffusion. Thus, early oral therapy may be a reasonable option in GPC-related PJIs. METHODS: A 2 year before and after monocentric study that aimed to compare two antibiotic strategies. Empirical intravenous postoperative antibiotic treatment was followed by 7 to 10 days of intravenous targeted therapy ('before' group) or by full orally targeted antibiotic treatment ('after' group). The primary outcome was a treatment failure during follow-up. RESULTS: A total of 93 patients were analysed, 43 and 50 in the before and the after groups, respectively. Both groups were comparable in terms of surgical procedures, comorbidities, microbiological documentation and infection site. Antibiotics prescribed to our patients had high oral bioavailability and bone diffusion with rifampicin/fluoroquinolone combinations being the most frequent antibiotic regimens. Both hospital stay and intravenous antibiotic treatment mean durations were shorter in the before group than in the after group [15.0 versus 11.0 days; (P < 0.01) and 13.0 versus 7.0 days; P < 0.001, respectively]. The remission rate assessed after at least a year of follow-up was comparable in the before and the after groups (hazard ratio = 0.70; 95% CI 0.30-1.58). CONCLUSIONS: Full oral targeted antibiotic therapy using a drug regimen with high oral bioavailability and good bone diffusion is an option for the treatment of patients with GPC-related PJIs.


Assuntos
Cocos Gram-Positivos , Administração Intravenosa , Administração Oral , Antibacterianos/uso terapêutico , Humanos , Rifampina
5.
Clin Orthop Relat Res ; 479(7): 1534-1544, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34128911

RESUMO

BACKGROUND: Patient-reported outcome measures such as the Oxford-12 Hip Score and Hip Disability and Osteoarthritis Outcome Score (HOOS) are used in daily orthopaedic practice to evaluate patients. Because different studies use different scores, it would be important to build conversion tables between scores (crosswalk) to compare the results of one study with those of another study. Various mapping methods can be used to develop crosswalk tables that convert Oxford-12 scores to the HOOS (and its derivatives, including the HOOS physical function short form, HOOS joint replacement, and HOOS-12) and vice versa. Although prior studies have investigated this issue, they are limited to short forms of the HOOS score. Consequently, they cannot be applied to hip preservation surgery and do not include quality-of-life items, whereas the Oxford-12 Hip Score is used for all hip evaluations. QUESTIONS/PURPOSES: We prospectively studied the Oxford-12 and HOOS and its derivatives to (1) determine which version of the HOOS has the best mapping with the Oxford-12, (2) define the most-appropriate mapping method using selected indicators, and (3) generate crosswalk tables between these two patient-reported outcome measures. METHODS: The study enrolled 500 adult patients before primary THA (59% men [294 of 500 patients]) with hip osteoarthritis or avascular necrosis of the femoral head who completed the HOOS and Oxford-12. Patients were recruited from January 2018 to September 2019 in a tertiary-care university hospital, and we included all primary THAs in patients older than 18 years with a BMI lower than 35 kg/m2 and greater than 18 kg/m2. After a minimum of 6 months of follow-up, 39% (195 of 500) of the patients were assessed using the same tools. To determine which version of the HOOS mapped best to the Oxford-12 and what the most-appropriate mapping method was, we used preoperative data from all 500 patients. Because there is no consensus on the method to establish crosswalk, various mapping methods (linear regression, tobit regression, and quantile regression) and equating methods (linear equating and equipercentile method) were applied along with cross-validation to determine which method was the most suitable and which form of the HOOS provided the best result according to different criteria (mean absolute error, r2, and Kolmogorov-Smirnov distance).To generate crosswalk tables, we created a conversion table (between the Oxford-12 and the HOOS form that was chosen after answering our first research question and the method chosen after answering our second question) using preoperative and postoperative data (n = 695). This table was meant to be simple to use and allows easy conversions from one scoring system to another. RESULTS: The Oxford-12 and HOOS were strongly correlated (Pearson correlation coefficient range 0.586-0.842) for the HOOS subcategories and HOOS physical function, HOOS joint replacement, and HOOS-12. The correlation between the HOOS-12 and Oxford-12 was the strongest (r = 0.825). According to the three different criteria and five methods, the HOOS-12 was the best suited for mapping. The goal was to minimize the mean absolute error (perfect model = 0), have a Kolmogorov-Smirnov distance as close as possible to 0, and have the r2 as close as possible to 1. Regarding the most-suitable method for the crosswalk mapping (research question 2), the five methods generated similar results for the r2 (range 0.63-0.67) and mean absolute error (range 6-6.2). For the Kolmogorov-Smirnov distance, the equipercentile method was the best (Kolmogorov-Smirnov distance 0.04), with distance reduced by 43% relative to the regression methods (Kolmogorov-Smirnov distance 0.07). A graphical comparison of the predicted and observed scores showed that the equipercentile method provided perfect superposition of predicted and observed values after mapping. Finally, crosswalk tables were produced between the HOOS-12 and Oxford-12. CONCLUSION: The HOOS-12 is the most complete and suitable form of the HOOS for mapping with the Oxford-12, while the equipercentile method is the most suitable for predicting values after mapping. This study provides clinicians with a reliable tool to crosswalk between these scores not only for joint arthroplasty but also for all types of hip surgeries while also assessing quality of life. Our findings should be confirmed in additional studies. CLINICAL RELEVANCE: The resulting crosswalk tables can be used in meta-analyses, systematic reviews, or clinical practice to compare clinical studies that did not include both outcome scores. In addition, with these tools, the clinician can collect only one score while still being able to compare his or her results with those obtained in other databases and registries, and to add his or her results to other databases and joint registries.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Avaliação da Deficiência , Necrose da Cabeça do Fêmur/cirurgia , Osteoartrite do Quadril/cirurgia , Medidas de Resultados Relatados pelo Paciente , Adulto , Idoso , Idoso de 80 Anos ou mais , Correlação de Dados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Período Pré-Operatório , Estudos Prospectivos , Qualidade de Vida , Análise de Regressão , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Adulto Jovem
6.
Ann Clin Microbiol Antimicrob ; 19(1): 9, 2020 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-32199450

RESUMO

BACKGROUND: This study aimed to evaluate in vitro susceptibility to ceftobiprole of clinical strains identified from prosthetic joint infections (PJIs) compared to that of the associations currently recommended for post-operative empirical antibiotic therapy (PEAT) (vancomycin with either cefepime, third-generation cephalosporin or piperacillin-tazobactam). METHODS: We performed a 1-year retrospective study on all the surgical procedures performed in our hospital for PJI. Susceptibility profiles of all the strains cultured from surgical samples were reviewed to compare ceftobiprole to current used associations. RESULTS: During the study period (from January 2018 to December 2018), we identified 106 patients managed for PJI and a total of 216 surgical interventions. One hundred-fifty strains were identified from intraoperative samples, excluding redundant strains. Staphylococcus spp. represented 52.7% of all strains and Enterobacteriales 13.3%. Twenty-three patients had polymicrobial infection (22%). Among 149 surgical procedures with positive culture results, ceftobiprole covered the bacterial strains in 138 (92.6%) cases. In comparison, this percentage was 94.6% for vancomycin plus cefepime (p = 0.64), 92.6% for vancomycin plus a third-generation cephalosporin in 138 cases (p = 1) and 94.6% for vancomycin plus piperacillin-tazobactam) (p = 0.64). CONCLUSION: Based on antimicrobial susceptibility testing, our results suggest that ceftobiprole could be an interesting option for PEAT in PJIs, allowing the use of a single agent.


Assuntos
Antibacterianos/uso terapêutico , Cefalosporinas/uso terapêutico , Infecções Relacionadas à Prótese/tratamento farmacológico , Coinfecção/tratamento farmacológico , Infecções por Enterobacteriaceae/tratamento farmacológico , Feminino , Humanos , Masculino , Testes de Sensibilidade Microbiana , Infecções Relacionadas à Prótese/microbiologia , Estudos Retrospectivos , Infecções Estafilocócicas/tratamento farmacológico , Infecções Estafilocócicas/microbiologia
7.
J Arthroplasty ; 35(12): 3703-3709, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32768257

RESUMO

BACKGROUND: We aimed to compare the long-term clinical outcomes, complications, and survival of 2 revision stems with different geometries, extents of coating, and distal-locking mechanisms. METHODS: We retrospectively compared outcomes at a minimum of 7 years following revision THA using 2 proximally coated distal-locking stems: 98 Ultime first-generation (G1) and 116 Linea second-generation (G2) stems. Ten-year Kaplan-Meier survival was assessed considering stem re-revision for any reason and for aseptic reasons. At final follow-up, Harris Hip Score and Oxford Hip Score were collected, and any thigh pain or complications were noted. RESULTS: Considering re-revision for any reason, survival was 69% for G1 stems and 91% for G2 stems. Considering re-revision for aseptic reasons, survival was 77% for G1 stems and 92% for G2 stems. Re-revisions were due to fracture of 6 G1 stems but no G2 stems. Complications that required reoperation without stem or cup removal occurred in 3 of the G1 stems and 1 of the G2 stems. Compared to the G1 stems, the G2 stems resulted in better Harris Hip Score (83 vs 71, P = .001), Oxford Hip Score (22 vs 27, P = .019), less thigh pain (4% vs 39%, P < .001), and fewer nonoperated complications (9% vs 15%). CONCLUSION: The second-generation stem had significantly better survival and clinical outcomes than the first-generation stem. The differences in survival and clinical outcomes could be attributed to the larger coated surface of the G2 stem and to the fact that the G1 stem was originally intended as a temporary implant to be followed by de-escalation.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
8.
Int Orthop ; 44(9): 1661-1667, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32385555

RESUMO

BACKGROUND: Limiting the risk of dislocation is one of the main aims of both dual mobility and Lefèvre retentive cups. However, these devices have never been compared. The goal of our study was to compare these devices in total hip arthroplasty revisions for instability. The judgement criterion was non-recurrence of dislocation in a follow-up period of eight years. METHODS: This retrospective case-control study compared two continuous paired series of total hip arthroplasty revisions for instability. These series included 63 patients and 159 patients with implantation of a Lefèvre retentive cup and a dual mobility cup, respectively. RESULTS: The success rate at eight years (i.e., no recurrence) was 91 ± 0.05% and 95 ± 0.02% in the Lefèvre retentive cup and dual mobility groups, respectively. The difference was not statistically significant (p = 0.6). CONCLUSION: It seems that the Lefèvre retentive cup provides comparable outcomes with the dual mobility cup in the total hip arthroplasty revisions for instability, avoiding recurrence in long term.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Estudos de Casos e Controles , Seguimentos , Luxação do Quadril/epidemiologia , Luxação do Quadril/cirurgia , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos
9.
Knee Surg Sports Traumatol Arthrosc ; 27(4): 1241-1250, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30203198

RESUMO

PURPOSE: Few studies investigated whether trochlear and patellar design enhancements improve long-term outcomes of total knee arthroplasty (TKA). This study aimed to compare the long-term survival and complication rates of two consecutive generations of the same TKA system with identical tibiofemoral geometry, but different patellofemoral designs. METHODS: The authors retrieved the records of 93 patients (104 knees) operated with the HLS II system and 116 patients (122 knees) operated with HLS Evolution system. Patients were evaluated preoperatively and at a minimum of 10 years noting all complications. Kaplan-Meier (KM) survival was compared for two endpoints: (1) revision of all components and (2) revision of any component. RESULTS: From the HLS II series, the incidence of revision of all components was 6.4%, and of any component was 9.8%. From the HLS Evolution series, the incidence of revision of all components was 4.1%, and of any component was 5.1%. Comparing the survival at equivalent follow-up of 14 years, considering revision of all components, the HLS II had higher survival than the HLS Evolution (98.9% vs 95.9%), while considering revision of any component, the HLS II had lower survival than the HLS Evolution (93.0% vs 94.9%). The differences in survival of the two implants were not significant, neither at equivalent follow-up of 14 years (n.s.), nor at maximum follow-up of each cohort (n.s.). The complication rate was higher for the HLS II series compared to the HLS Evolution (28% vs 12%, p = 0.009), but patellofemoral complications were not more frequent (8% vs 6%, n.s.). CONCLUSIONS: Though the differences in survival of the two implants were not significant, conflicting findings are observed due to partial revisions for patellar fractures (5 in the HLS II series and 1 in the HLS Evolution series) which could be related to patellofemoral design enhancements. This study highlights the importance of patello-femoral geometry, which is often overlooked in TKA. LEVEL OF EVIDENCE: Retrospective comparative study, Level III.


Assuntos
Artroplastia do Joelho/métodos , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho , Patela/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur/diagnóstico por imagem , Seguimentos , França/epidemiologia , Humanos , Incidência , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Patela/diagnóstico por imagem , Complicações Pós-Operatórias/epidemiologia , Prognóstico , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Adulto Jovem
10.
J Arthroplasty ; 32(4): 1206-1210, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27988181

RESUMO

BACKGROUND: Total hip arthroplasty with metal-on-metal (MoM) bearings has been suspected to cause adverse reactions to metal debris (ARMD), with the incidence varying greatly by implant type and patient gender. The prevalence of ARMD from small-diameter MoM bearings in women is unknown, especially after 10 years of follow-up (FU). METHODS: Cementless 28-mm MoM total hip arthroplasty bearings (Metasul) were implanted consecutively in 42 active women between 1996 and 2002. They were reviewed after a minimum of 10 years' FU with clinical, laboratory, radiological, and ultrasound assessments. RESULTS: Mean FU was 15.9 years (range, 13-18). The mean Postel-Merle d'Aubigné and Oxford scores were 16.9 (range, 13-18) and 15.1 (range, 12-24), respectively, at FU. Mean cup inclination angle was 46.3° (range, 35°-57°). No femoral osteolysis was detected, but limited acetabular osteolysis (11%) over the screw holes occurred in 5 cases. No liquid or solid synovial reactions or ARMD were apparent on ultrasound, even in the 5 cases of pelvic osteolysis. Mean chromium levels were 1.32 µg/L (range, 0.1-7.9) and cobalt levels were 1.85 µg/L (range, 0.35-13.6). Cobalt was >3 µg/L in only 3 cases. The 15.9-year survivorship was 95% (range, 94.1%-98.9%). CONCLUSION: Reliable results were obtained with 28-mm MoM bearings, notably in young, active patients. This implant configuration requires very accurate positioning. No ARMD was seen in this group at 16 years' FU.


Assuntos
Prótese de Quadril/efeitos adversos , Próteses Articulares Metal-Metal/efeitos adversos , Metais/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Acetábulo/cirurgia , Adolescente , Adulto , Artroplastia de Quadril/efeitos adversos , Cromo/sangue , Cobalto/sangue , Feminino , Fêmur/cirurgia , Seguimentos , Humanos , Incidência , Pessoa de Meia-Idade , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Prevalência , Desenho de Prótese , Radiografia , Reoperação , Estudos Retrospectivos , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia , Adulto Jovem
11.
Int Orthop ; 41(12): 2503-2508, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28616704

RESUMO

INTRODUCTION: Metal-on-metal (MoM) hip replacement bearings produce metallic ions that can cause health complications. Metallic release also occurs with other materials, but data on metallic ion levels after knee arthroplasty are sparse. We postulate that knee replacement generates elevating metallic ions (chromium (Cr), cobalt (Co) and titanium (Ti)) during the first year after implantation. PATIENTS AND METHODS: This ongoing prospective study included all patients who underwent the same type of knee arthroplasty between May and December 2013. Cr, Co and Ti levels were measured in whole blood at pre-operation and one-year follow-up (6 and 12 months). Clinical and radiographic data (range of motion, Oxford, International Knee Society (IKS) and satisfaction scores) were recorded. RESULTS: In 90 patients, preoperative Cr, Co and Ti metallic ion levels were respectively 0.45 µg/l, 0.22 µg/l, 2.94 µg/l and increased to 1.27 µg/l, 1.41 µg/l, 4.08 µg/l (p < 0.0001) at last one-year follow-up. Mean Oxford and IKS scores rose, respectively, from 45.9 (30-58) and 24.9 (12-52) to 88.3 (0-168) and 160.8 (93-200) (p < 0.001). CONCLUSION: After the implantation of knee arthroplasty, we found significant blood elevation of Cr, Co and Ti levels one year after implantation exceeding the normal values. This metallic ion release could lead to numerous effects: allergy, hypersensitivity, etc.


Assuntos
Artroplastia do Joelho/efeitos adversos , Cromo/sangue , Cobalto/sangue , Prótese do Joelho/efeitos adversos , Titânio/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese/efeitos adversos
12.
Anal Chem ; 88(5): 2777-83, 2016 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26824493

RESUMO

Bone samples extracted from embalmed cadavers are commonly used as controls in the study of bone. The effects of embalmment on the molecular composition of bone are unknown. The objective of this study was to determine the effect of embalmment on the molecular composition and structure of bone, as evaluated by Raman spectroscopy. Bone samples of femoral heads from five embalmed donors and five fresh-frozen donors were compared using Raman microspectroscopy with DuoScan technology. Physicochemical parameters simultaneously describing the organic and mineral phases of bone were compared using the Mann-Whitney U test. Partial least squares discriminant analysis (PLS-DA) was used to determine specific Raman spectral features of each group. Study of the mineral phase showed a 15% reduction of the mineral-to-matrix ratio (p < 0.001), an 8% decrease of type B carbonate substitution (p < 0.001), and a 2% increase in crystallinity (p < 0.001) in the embalmed donors group compared to those of the fresh donors group. Regarding the organic phase of bone, the hydroxyproline-to-proline ratio was increased by 18% in the embalmed group (p < 0.001), with no variation in both the relative proteoglycan content (GAG/CH3) (p = 0.08) and collagen maturity (p = 0.57). PLS-DA showed that the embalmed group was characterized mainly by peaks assigned to hydroxyproline, lipids, and collagen. Embalmment induces significant modifications of the molecular composition of bone. Bone samples from embalmed subjects should be avoided as controls for Raman spectroscopy studies. Preservation procedures performed prior to bone sampling should be reported in studies using human cadaver samples.


Assuntos
Osso e Ossos , Cadáver , Análise Espectral Raman/métodos , Humanos , Microscopia Confocal
13.
Clin Orthop Relat Res ; 474(10): 2126-33, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27278679

RESUMO

BACKGROUND: A primary concern of younger, more active patients who have undergone total hip arthroplasty (THA) is the longevity of the implant. Cementless fixation and hard-on-hard bearings are recognized as options to enhance THA durability. Earlier, we published a series of 83 cementless primary THAs using 28-mm metal-on-metal (MoM) bearings in patients aged 50 years or younger; here we provide concise followup on that same group after an additional 8-year survey period. QUESTIONS/PURPOSES: (1) What is the long-term survivorship of cementless primary THA using 28-mm MoM bearings in patients aged 50 years or younger? (2) What are the clinical and radiographic results of cementless THA in this active patient population? (3) Can any of the observed implant failures or adverse events be attributed to the metallic nature of the bearing couple? METHODS: We retrospectively reviewed 83 cementless THAs performed in three institutions over a decade (1995-2004) in 68 patients with 28-mm MoM articulation. All patients (15 bilateral) had a median age of 42 years (range, 24-50 years) at the time of the index procedure and 56 of them (82% [70 hips]) had activity level graded Devane 4 or 5 before significant hip pain. A 28-mm Metasul™ articulation was used with an Alloclassic-SL™ cementless stem in all cases paired with three different cementless titanium acetabular components (one threaded and two press-fit cups) from the same manufacturer. Survivorship analysis was calculated according to Dobbs life table, patient clinical results were evaluated with use of the Postel-Merle d'Aubigné scoring system, radiographic analysis was performed by independent observers, and cobalt level was determined in whole blood. RESULTS: The 15-year survivorship (33 hips at risk) for revision for any reasons (four hips) and for aseptic loosening (one hip) was 96% (95% confidence interval [CI], 81%-99%) and 99% (95% CI, 85%-99.9%), respectively. The median Merle d'Aubigné-Postel score remained stable at 17 points (range, 10-18). Thus far, we have not observed pseudotumors or other adverse reactions to metallic debris. Eight hips have undergone reoperation: trochanteric suture removal (one), psoas tendon impingement (two), and five revisions for periprosthetic fracture (one), late infection (two), acetabular osteolysis (one, as a result of polyethylene backside wear), and one hydroxyapatite-coated cup for aseptic loosening. None of the complications, failures, or revisions observed so far could directly be related to the metallic nature of the 28-mm Metasul bearings used in this selected group of patients. CONCLUSIONS: The current survey at 13-year median followup has not yet indicated any long-term deleterious effects related to dissemination of metallic ions. Two senior authors continue to use 28- or 32-mm Metasul™ bearings with cementless THA components in young and active patient populations. Longer followup with a more sophisticated imaging study is necessary to confirm this so far positive report. LEVEL OF EVIDENCE: Level IV, therapeutic study.


Assuntos
Artroplastia de Quadril/instrumentação , Articulação do Quadril/cirurgia , Prótese de Quadril , Próteses Articulares Metal-Metal , Adulto , Fatores Etários , Artroplastia de Quadril/efeitos adversos , Fenômenos Biomecânicos , Cromo/sangue , Ligas de Cromo , Feminino , Seguimentos , França , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Recuperação de Função Fisiológica , Reoperação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
14.
Clin Orthop Relat Res ; 474(10): 2190-9, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27255729

RESUMO

BACKGROUND: Despite widespread use of ceramic-on-ceramic (CoC) in total hip arthroplasty (THA) during the past 10 years, little is known about why revisions are performed in hips with this bearing or the time elapsed before revision. QUESTIONS/PURPOSES: The purposes of this study were: (1) Do the reasons for first revision differ between CoC bearings and other bearing couples? (2) Does the time to revision differ between CoC and other bearing couples? (3) Are there unique reasons for revisions of CoC bearings? METHODS: All members of the Société Française de Chirurgie Orthopédique et Traumatologique (SoFCOT) who performed ≥ 30 revisions per year were invited to participate in this multicenter, prospective, observational study. Our data represent 12% of the revision procedures performed in France. A total of 2107 first revisions of THA (from January 2010 to December 2011) were done in 2107 patients (1201 females [57%] and 906 males [43%]; median age, 73 years; age range, 17-104 years) at the time of surgery after a median of 11 years (range, 0 day-42 years) after the primary THA. There were 238 of 2107 (11%) CoC, 148 of 2107 (7%) metal-on-metal (MoM), and 1721 of 2017 (82%) metal-on-polyethylene (MoP) bearings. RESULTS: The reasons for reoperation differed according to the bearing component: (1) for the MoP reference bearing (odds ratio [OR]; 95% confidence interval), cup loosening occurred in 698 of 1721 hips (41%), periprosthetic fracture in 220 of 1721 hips (13%), and osteolysis in 213 of 1721 hips (12%); (2) for CoC, cup loosening occurred in 41 of 238 hips (17%) (OR, 0.31 [0.22-0.43; p < 0.001), infection in 39 of 238 hips (16%) (OR, 1.63 [1.12-2.37]; p = 0.01), and dislocation in 23 of 238 hips (10%) (OR, 0.9 [0.57-1.42]; p = 0.9); (3) for MoM, cup loosening occurred in 28 of 148 hips (19%) (OR, 0.34 [0.22-0.52]; p < 0.001), adverse reaction to metallic debris in 26 of 148 hips (18%) (OR, 18.12 [9.84-33.4]; p < 0.001), and infection in 16 of 148 hips (11%) (OR, 1 [0.59-1.73]; p = 0.9). In comparison with MoP, osteolysis was rarely the reason for revision in CoC (four of 238 hips [2%]; OR, 0.12 [0.05-0.33]; p < 0.001), but this bearing was frequently revised because of iliopsoas irritation (18 of 238 hips [8%]; OR, 4.9 [2.7-9]; p < 0.001). The time elapsed before revision differed between bearings: median of 3 years (range, 3 days to 28 years) for CoC and 4 years (range, 14 days to 37 years) for MoM versus a median 13 years (range, 0 day to 42 years) for MoP (p < 0.001). Thirty-seven of the 238 revisions (16%) were directly related to ceramic use (ceramic breakage [n = 23], squeaking [n = 6], impingement [n = 7], incorrect ceramic insert insertion [n = 1]). No factors were identified that contributed to breakage of the 12 bulk ceramic components (eight heads, four inserts, four of 12 Delta ceramic). No factors were associated with squeaking, iliopsoas irritation, or impingement, but component orientation was not assessed. CONCLUSIONS: The reasons and time to first revision differed between CoC and other bearings. CoC THAs are revised earlier and are sensitive to mechanical problems such as impingement, squeaking, and ceramic rupture that did not disappear with introduction of Delta ceramics and large-diameter (≥ 36 mm) bearings. CoC was rarely revised for osteolysis, but a high rate of iliopsoas irritation requires further investigation. LEVEL OF EVIDENCE: Level III, therapeutic study.


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Cerâmica , Articulação do Quadril/cirurgia , Prótese de Quadril , Próteses Articulares Metal-Metal , Polietileno , Complicações Pós-Operatórias/cirurgia , Reoperação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Distribuição de Qui-Quadrado , Feminino , França , Articulação do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Adulto Jovem
15.
Int Orthop ; 40(5): 907-12, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26572886

RESUMO

PURPOSE: To assess osseointegration and stability of a primary cementless femoral stem, many scoring systems have been developed, but none of them have taken into account only the radiolucent line. The purposes of this study were (1) to compare the results between the Engh score to assess osseointegration and stability of the cementless stem with results of a score called the O-SS score (osseointegration-secondary stability), which takes into account the radiolucent line, (2) to verify the relationship between these two scores and the functional results, and (3) to verify if there is a relationship between the O-SS score and secondary subsidence or a pedestal. METHODS: A clinical and radiological evaluation was performed in a group of 100 hip prosthesis revisions comparing the results obtained by Engh score and O-SS score for which reproducibility was analysed. RESULTS: Inter-observer reproducibility was estimated to be average at 0.5 and intra-observer reproducibility good at 0.7. The correlation with the Engh score was good at r = 0.59 (p < 0.0001). For the 80 cases assessed O-SS score as very good/good, Harris hip score was at 83.7 versus 78.25 for the 20 cases assessed as average/poor (p = 0.07). For the 73 cases with assessed Engh score as very good/good, this score was at 82.8 versus 82.14 for the 27 cases assessed as average/poor. No correlation between the O-SS score and secondary subsidence (p = 0.2) or pedestal (p = 0.2) was noticed. CONCLUSION: The evaluation of the clear radiolucent line alone, extent and location, is a sufficient condition to assess osseointegration and secondary stability of a cementless femoral stem.


Assuntos
Artroplastia de Quadril/métodos , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Osseointegração , Reoperação/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Desenho de Prótese , Reprodutibilidade dos Testes , Estudos Retrospectivos
16.
Int Orthop ; 39(8): 1487-94, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25564445

RESUMO

PURPOSE: The purpose of this study was to finalize a method allowing a qualitative and numerical evaluation of the bone stock and to confirm its reproducibility, to verify the relationship between the secondary bone stock value and the functional results, and to determine the main factors influencing the value of the bone stock. METHODS: A clinical and radiological evaluation was performed in a group of 150 revisions of total hip replacements according to a new method taking into account cortical bone thickness, bone density and bone defects. RESULTS: Interobserver reproducibility was evaluated at an average of 0.6 and intra-observer reproducibility was considered good at 0.8. Between the initial bone stock and at the last follow-up, no significant difference was noticed. For secondary bone stock considered as "very good or good", the gain was +38.1 points versus +29.9 points for patients evaluated as "average or poor" (p < 0.0001). Between the initial bone stock assessment and at last follow-up, a significant relation was found in numerical values for the global type of primary fixation and in the presence of osteopenia (p < 0.0001). CONCLUSIONS: Deficient secondary bone stock can result in less favourable functional results. The numerical scores confirm the importance of strategic choices during surgery in order to manage bone stock preservation.


Assuntos
Fêmur/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Feminino , Fêmur/diagnóstico por imagem , Fêmur/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Radiografia , Reoperação , Reprodutibilidade dos Testes , Estudos Retrospectivos
17.
Int Orthop ; 38(5): 923-8, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24323353

RESUMO

PURPOSE: Cup design has been incriminated as the source of groin pain after hip resurfacing but has not been well described; thus, it was assessed in a prospective study looking at three implant types. METHODS: A group-match was done between three groups of hip resurfacing devices according to age, sex, body mass index, activity level, osteoarthritis aetiology and pre-operative scores. RESULTS: The global groin pain rate was 5.7 % at six months and 2.7 % at last follow-up. Groin pain rate was significantly different between the three groups (p = 0.004) and had a strong influence on the subjective results (p = 0.04). No groin pain emerged between six months and last follow-up. No clinical differences were noted in Harris hip score and Merle d'Aubigné-Postel score at last follow-up. However, the Oxford hip score and Devane activity score were significantly lower for cups with macrostructures. CONCLUSION: The low groin pain rate in this prospective cohort was probably secondary to the specific surgical technique used and seems to be correlated with cup design. Macrostructures on the external part of the cup could be significantly harmful.


Assuntos
Prótese de Quadril/efeitos adversos , Dor/etiologia , Feminino , Virilha , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese
18.
Bone Joint J ; 106-B(3 Supple A): 97-103, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38423079

RESUMO

Aims: Mechanical impingement of the iliopsoas (IP) tendon accounts for 2% to 6% of persistent postoperative pain after total hip arthroplasty (THA). The most common initiator is anterior acetabular component protrusion, where the anterior margin is not covered by anterior acetabular wall. A CT scan can be used to identify and measure this overhang; however, no threshold exists for determining symptomatic anterior IP impingement due to overhang. A case-control study was conducted in which CT scan measurements were used to define a threshold that differentiates patients with IP impingement from asymptomatic patients after THA. Methods: We analyzed the CT scans of 622 patients (758 THAs) between May 2011 and May 2020. From this population, we identified 136 patients with symptoms suggestive of IP impingement. Among them, six were subsequently excluded: three because the diagnosis was refuted intraoperatively, and three because they had another obvious cause of impingement, leaving 130 hips (130 patients) in the study (impingement) group. They were matched to a control group of 138 asymptomatic hips (138 patients) after THA. The anterior acetabular component overhang was measured on an axial CT slice based on anatomical landmarks (orthogonal to the pelvic axis). Results: The impingement group had a median overhang of 8 mm (interquartile range (IQR) 5 to 11) versus 0 mm (IQR 0 to 4) for the control group (p < 0.001). Using receiver operating characteristic curves, an overhang threshold of 4 mm was best correlated with a diagnosis of impingement (sensitivity 79%, specificity 85%; positive predictive value 75%, negative predictive value 85%). Conclusion: Pain after THA related to IP impingement can be reasonably linked to acetabular overhang if it exceeds 4 mm on a CT scan. Below this threshold, it seems logical to look for another cause of IP irritation or another reason for the pain after THA before concluding that impingement is present.


Assuntos
Artroplastia de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Estudos de Casos e Controles , Tendões , Acetábulo/diagnóstico por imagem , Dor Pós-Operatória
19.
Orthop Traumatol Surg Res ; : 103820, 2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38266672

RESUMO

INTRODUCTION: The GeneXpert® MRSA/SA SSTI (Methicillin Resistant Staphylococcus aureus/S. aureus skin and soft tissue infection) PCR test allows early detection of methicillin resistance in staphylococci. This test was developed for skin infections and has been evaluated for prosthetic joint infections but, to our knowledge, has not been evaluated for hardware infections outside of arthroplasties. Furthermore, we conducted a retrospective study in patients with non-prosthetic osteosynthesis hardware aiming: (1) to identify the diagnostic values of the PCR test compared to conventional cultures and the resulting rate of appropriate antibiotic therapy; (2) to identify the rate of false negative (FN) results; (3) to identify and compare the rates of failure of infectious treatment (FN versus others); (4) to search for risk factors for FN of the PCR test. HYPOTHESIS: The PCR test allowed early and appropriate targeting of antibiotic therapy. MATERIAL AND METHODS: The results of PCR tests and conventional cultures for osteoarticular infections of non-prosthetic hardware over four years (2012-2016) were compared to identify the diagnostic values of using the results of conventional culture as a reference and the rate of appropriate antibiotic therapies. Infectious management failures between the results of the FN group and the others were compared, and variables associated with a FN of the PCR test were identified. RESULTS: The analysis of 419 PCR tests allowed us to establish a sensitivity of 42.86%, a specificity of 96.82%, a positive predictive value of 60% and a negative predictive value of 93.83%. Using the results of the PCR test for the targeting of postoperative antibiotic therapy, it was suitable for staphylococcal coverage in 90.94% (381/419). The rates of patients for whom infectious treatment failed were not significantly different between the FN group and the other patients (20.8% versus 17.7%, respectively; Hazard Ratio=1.12 (95%CI 0.47-2.69, p=0.79)). A skin opening during the initial trauma (p=0.005) and a polymicrobial infection were significantly associated with a risk of FN from the PCR test (p<0.001). CONCLUSION: The PCR test makes it possible to reduce the duration of empirical broad-spectrum antibiotic therapy during the treatment of an infection of osteosynthesis hardware but causes a lack of antibiotic coverage in 9.06% of cases. LEVEL OF EVIDENCE: III; diagnostic case control study.

20.
Clin Orthop Relat Res ; 471(12): 3891-900, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23516032

RESUMO

BACKGROUND: Dual-mobility (DM) cups were introduced to minimize the risk of THA dislocation. The overall rate of dislocation of DM cups (including both large and small articulations) is controversial and ranges from 0% to 5% in previous studies. QUESTIONS/PURPOSES: We therefore recorded (1) the dislocation rate, (2) loosening and osteolysis, and (3) subsequent related revisions with DM cups. METHODS: Between 1998 and 2003, 2480 primary THAs with DM cups were undertaken in 2179 patients. The mean age was 69 years (range, 19-94 years). This group underwent specific clinical and radiographic evaluation at a minimum followup of 0.17 years (mean, 7 years; range, 0.17-11 years) to assess dislocation, reoperation, osteolysis, and cup fixation. RESULTS: There were 22 dislocations (0.88%): 15 dislocations of large articulations (0.6%), with two (0.08%) recurring but only one requiring revision (0.04%), and seven intraprosthetic small articulation dislocations (0.28%), all needing revision surgery. At last followup, mean Harris hip score was 91 (range, 60-100); 2439 cups (98%) showed no signs of loosening; and 141 patients (145 hips) had osteolysis (6%). Osteolysis and cup loosening were more frequent in patients younger than 50 years at the time of surgery. The 10-year survivorship considering revision for any reason was 93% (95% CI, 91%-95%). CONCLUSIONS: DM cups had a low dislocation rate in primary THA, with a limited frequency of adverse effects. We recommend DM cups to minimize dislocation in populations at high risk for instability, but they should be avoided in younger, active patients at higher risk for osteolysis.


Assuntos
Artroplastia de Quadril/efeitos adversos , Luxação do Quadril/epidemiologia , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Luxação do Quadril/etiologia , Luxação do Quadril/cirurgia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Osteólise/epidemiologia , Osteólise/etiologia , Osteólise/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA