Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Cancer Res ; 35(7): 1727-33, 1975 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-236826

RESUMO

Levels of nicotinamide and N-1-methylnicotinamide in serum, liver, and kidney as well as renal clearances and 24-hr urine levels of N-1-methylnicotinamide were compared in normal rats and rats bearing Walker 256 tumors. There was no significant difference between normal and tumor-bearing rats with regard to nicotinamide levels. With regard to N-1-methylnicotinamide, tumor-bearing rats had significantly lower serum and liver levels and significantly higher 24-hr urine levels and renal clearances. Walker 256 tumor tissue and liver and kidney from a normal and a tumor-bearing rat were separately examined for S-adenosylmethionine:nicotinamide methyltransferase activity. The specific activity in tumor tissue extract was greater than that in each liver extract, which, in turn, was much greater than the specific activity in each tissue (liver and kidney) from the tumor-bearing rat was equal to the specific activity in the corresponding tissue of the normal rat. S-adenosylmethionine:nicotinamide methyltransferase was obtained with 18-fold purification from a tissue extract of Walker 256 tumor. The enzyme activity required activation by thiols, and maximal activity was observed at pH 8.6. The Km's for the substrates, S-adenosylmethionine and nicotinamide, were 7.0 x 10--3 mM and 0.50 mM respectively. The Ki's for the products, S-adenosylhomocysteine and N-1-methylnicotinamide, were respectively, 25 x 10--3 mM and greater than 5 mM.


Assuntos
Carcinoma 256 de Walker/metabolismo , Niacinamida/metabolismo , Animais , Carcinoma 256 de Walker/enzimologia , Ditiotreitol/farmacologia , Ativação Enzimática , Humanos , Concentração de Íons de Hidrogênio , Recém-Nascido , Rim/metabolismo , Cinética , Fígado/enzimologia , Fígado/metabolismo , Metiltransferases/isolamento & purificação , Metiltransferases/metabolismo , Niacinamida/análogos & derivados , Niacinamida/urina , Ratos
2.
J Appl Physiol (1985) ; 88(5): 1537-44, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10797109

RESUMO

A simple and reliable means for accurate, chronic measurement of pulsatile blood pressure (BP) from conscious, freely moving laboratory mice was developed and validated. The newly developed device consists of a small (1.9 ml, 3.4 g), fully implantable radiotelemetry transmitter. Initial frequency response tests showed an adequate dynamic response; the average -3-dB point found in five transmitters was 145 +/- 14 (SD) Hz. BP, heart rate, and locomotor activity were recorded from 16 chronically (30-150 days) implanted mice. Mean arterial and pulse pressure, checked at regular intervals, ranged from 90-140 mmHg and from 30-50 mmHg, respectively, throughout the study. Transmitter BP measurements were validated against a Millar 1.4-Fr. transducer-tipped catheter. The mean error of the transmitters for diastolic pressures was +1.1 +/- 6.9 mmHg (n = 7). The error for systolic pressures was, on average, 2.7 +/- 3.9 mmHg larger. This new device accurately monitors BP, heart rate, and locomotor activity in conscious, untethered, freely moving mice living in their home cages for periods of at least 150 days.


Assuntos
Pressão Sanguínea , Frequência Cardíaca , Telemetria , Animais , Materiais Biocompatíveis , Desenho de Equipamento , Camundongos , Monitorização Fisiológica , Atividade Motora/fisiologia , Telemetria/instrumentação
3.
Brain Res Bull ; 45(1): 111-6, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-9434211

RESUMO

Radiolabeled sucrose is often used to assess blood-brain barrier (BBB) injury in the rat, but published transfer constants (K[i]s) for sucrose permeation of the intact BBB (control K[i]s) are highly discrepant. A potential problem with the commonly used tracer, [14C(U)]sucrose, is radiolytic generation, preuse, of radiocontaminants that might readily penetrate the BBB. How such contaminants might affect measurements of sucrose K(i)s was examined for both the intact and the ischemically injured BBB. Three stocks of [14C(U)]sucrose were studied: newly purchased ("new"), 4-year-old, and 7-year-old. A high purity (99.9%) "new" and a 2-year-old stock of [3H(fructose-1)]sucrose were also tested. Pentobarbital-anesthetized male Sprague-Dawley rats were injected i.v. with each tracer separately (six to eight rats) and K(i)s in five brain regions were measured by the multiple-time graphical method. The "new" 14C-, "new" 3H-, and 2-year-old 3H-sucrose yielded comparable K(i)s , ranging from 1.2 +/- 0.1 to 2.4 +/- 0.3 nl x g(-1) x s(-1) (mean +/- SE) across the regions. The two old stocks of 14C-sucrose yielded significantly higher regional K(i)s : 5.1-6.3 (4-year-old) and 8.4-9.7 (7-year-old). Thin-layer chromatography of the three 14C-tracers revealed that each contained radioimpurities (ca. 2% in both the "new" and 4-year-old, and 9% in the 7-year-old), but that the old stocks contained larger amounts of relatively mobile (more lipophilic) impurities, which can be suspected as the main cause of the elevated K(i)s obtained. Additional rats were subjected to 10 min of cerebral ischemia, which effects a delayed BBB injury, and 6 h later the "new" 3H- and the 4-year-old 14C-sucrose were injected together. The K(i)s for both tracers were elevated by like, absolute amounts (deltaK[i]s), but by very different percentages, over their disparate baseline values in uninjured rats (for striatum and hippocampus, the most injured regions, deltaK(i)s were 3.9 to 4.4 nl x g[-1] x s[-1]). It is concluded that radiolysis of [14C(U)]sucrose yields certain labeled products that readily cross the BBB and that can seriously distort baseline K(i)s , even if present only in very small amounts. While this appears not to compromise assessment of BBB injury, definition of the authentic range of baseline, sucrose K(i)s for the rat BBB would appear to remain a challenge.


Assuntos
Barreira Hematoencefálica , Encéfalo/metabolismo , Radioisótopos de Carbono/farmacocinética , Contaminação de Medicamentos , Ataque Isquêmico Transitório/metabolismo , Sacarose/farmacocinética , Animais , Radioisótopos de Carbono/normas , Cinética , Masculino , Técnica de Diluição de Radioisótopos , Ratos , Ratos Sprague-Dawley , Valores de Referência , Sacarose/sangue , Sacarose/normas , Distribuição Tecidual
4.
Magn Reson Imaging ; 5(1): 51-6, 1987.
Artigo em Inglês | MEDLINE | ID: mdl-3586872

RESUMO

Spin-echo 19F magnetic resonance imaging was performed at 2.0 T to explore the in vivo spatial distribution of halothane in the rabbit head. Because the halothane concentration is low in vivo, and because the measured relaxation times of the 19F resonance peak for halothane were T1 approximately equal to 1.0 sec and T2 approximately equal to 3.5-65 msec, 1-3-h imaging times were required (TR = 1 sec, TE = 9 msec) in order to obtain adequate images with a 64 X 256 raw data matrix and a 20-mm slice thickness. With this technique, halothane was primarily detected in lipophilic regions of the rabbit head, but little or no halothane was observed in brain tissue. Because T2 was shorter in brain tissue than in surrounding fat, a shorter TE than we could obtain is needed for optimal spin-echo imaging of brain halothane.


Assuntos
Química Encefálica , Halotano/análise , Espectroscopia de Ressonância Magnética , Animais , Medula Óssea/análise , Lipídeos/análise , Coelhos
5.
Lab Anim ; 34(3): 272-80, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11037121

RESUMO

This paper describes for the first time the possibility for recording the systolic pressure (SP), diastolic pressure (DP), and the mean arterial pressure (MAP) as well as the heart rate (HR) and locomotor activity (LA) in freely moving mice, using a commercially available telemetry and data acquisition system. The system comprises a new, small radio-telemetry transmitter implanted in the peritoneal cavity, a receiver board placed underneath the home cage, a multiplexer and a computer-based data acquisition system. The signals from the receiver were consolidated by the multiplexer and were stored and analysed by the computer. The telemetered pressure signals (absolute pressure) were corrected automatically for changes in atmospheric pressure measured by an ambient pressure monitor. The effects of implantation on animal behaviour, and, after the animals had recovered, the effects of handling on the SP, DP, MAP and HR were examined. The radio-telemetry system for recording the SP, DP, MAP and HR provides an accurate and reliable method for monitoring the direct effects of handling on SP, DP, MAP and HR. In addition, by using this new blood pressure (BP) transmitter, we maintain that BP measurements in freely moving mice are more efficient, reliable, and less labour-intensive than the measurement techniques described in the literature thus far.


Assuntos
Monitorização Ambulatorial da Pressão Arterial/instrumentação , Pressão Sanguínea/fisiologia , Implantes Experimentais , Procedimentos Cirúrgicos Operatórios/métodos , Telemetria , Animais , Ritmo Circadiano , Estudos de Viabilidade , Frequência Cardíaca/fisiologia , Masculino , Camundongos , Modelos Animais
7.
Clin Exp Hypertens A ; 13(5): 885-95, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1773522

RESUMO

Accurate continuous chronic measurements of blood pressure from conscious laboratory rats are critical to many experimental protocols but have been difficult or impossible to acquire. A system consisting of an implantable radio-telemetry device, receiver, and computer-based data acquisition system that allows such measurements to be easily obtained has been developed. This system is capable of monitoring and recording arterial pressure (waveform, systolic, diastolic, and mean), heart rate, and activity from rats weighing greater than 175 gm for periods in excess of 6 months. Chronic patency has been achieved through a patented design which includes an antithrombogenic film and a gel membrane located at the catheter tip. Validation of telemetered measurements via carotid catheter has demonstrated the accuracy to be better than +/- 5 mmHg in 85% (N = 20) tested at 3 weeks post implantation, 86% (N = 15) tested at 8 weeks, and 78% (N = 9) at 12 weeks. Incidence of loss of patency was 2.3% (N = 44). This system has a demonstrated ability to obtain accurate continuous chronic measurements of arterial pressure free of the stressors associated with conventional systems.


Assuntos
Determinação da Pressão Arterial/métodos , Frequência Cardíaca/fisiologia , Telemetria/métodos , Animais , Materiais Biocompatíveis , Cateterismo , Cateteres de Demora , Cuidados Pós-Operatórios/métodos , Ratos , Reprodutibilidade dos Testes , Fatores de Tempo
8.
Biopolymers ; 32(11): 1491-501, 1992 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-1457729

RESUMO

We calculated the uni-univalent ion distributions around the oligonucleotide d(AT)5.d(AT)5 in the A, B and wrinkled D conformation using the Metropolis Monte Carlo method. All atoms were included in the oligonucleotide model with partial charges and hard sphere radii assigned to each atom. The univalent counter- and coions were modeled as hard spheres with radius 0.3 nm. The solvent was assigned a dielectric constant of 80, corresponding to a temperature of 298K. The counterion distribution surrounding each of the conformers and the distribution surrounding an impenetrable cylinder, were calculated for four salt concentrations. We found significant counterion density in the major groove of the A DNA while fewer counterions occupied the grooves of B DNA. In the wrinkled D DNA, where groove occupancy is sterically hindered, the ion distributions were identical to the distributions surrounding the impenetrable, cylindrical model. This suggests that excluded volume effects significantly influence the details of the ion distributions near the oligomer, while the detailed charge distributions of the oligomer affects the ion distributions only minimally. Although substantial variation in counterion density was observed near the oligomers of differing conformations, the total number of counterions located within a cylinder surrounding the oligomer bounded radially by 2.4 nm was independent of the conformation of the oligomer. Therefore, for this model system, the local univalent counterion distributions are extremely sensitive to the geometry of the oligonucleotide whereas the extent of neutralization of the oligoanion is insensitive to the conformation of the oligomer.


Assuntos
Método de Monte Carlo , Oligonucleotídeos/química , Sequência de Bases , DNA , Íons , Dados de Sequência Molecular , Conformação de Ácido Nucleico
11.
Nurs Mirror Midwives J ; 127(9): 14, 1968 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-5187749
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA