Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 109
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Shoulder Elbow Surg ; 33(1): 181-191, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37598837

RESUMO

BACKGROUND: Dislocation is a major complication of reverse total shoulder arthroplasty (RSA). The humeral liner may be changed to a constrained type when stability does not improve by increasing glenosphere size or lateralization with implants, and patients, particularly women with obesity, have risks of periprosthetic instability that may be secondary to hinge adduction on the thorax, but there are few reports on its impact on the range of motion (ROM). This study aimed to determine the influence of humeral liner constraint on impingement-free ROM and impingement type using an RSA computer simulation model. METHODS: A virtual simulation model was created using 3D measurement software for conducting a simulation study. This study included 25 patients with rotator cuff tears and rotator cuff tear arthropathy. Impingement-free ROM and impingement patterns were measured during flexion, extension, abduction, adduction, external rotation, and internal rotation. Twenty-five cases with a total of 4 patterns of 2 multiplied by 2, making a total of 100 simulations: glenosphere (38 mm normal type vs. lateralized type) and humeral liner constraint (normal type vs. constrained type). There were 4 combinations: normal glenosphere and normal humeral liner, normal glenosphere and constrained humeral liner, lateralized glenosphere and normal humeral liner, and lateralized glenosphere and constrained humeral liner. RESULTS: Significant differences were found in all impingement-free ROM in 1-way analysis of variance (abduction: P = .01, adduction: P < .01, flexion: P = .01, extension: P = .02, external rotation: P < .01, and internal rotation: P < .01). Tukey's post hoc tests showed that the impingement-free ROM was reduced during abduction, external rotation, and internal rotation with the combination of the normal glenosphere and constrained humeral liner compared with the other combinations, and improved by glenoid lateralization compared with the combination of the lateralized glenosphere and constrained humeral liner. In the impingement pattern, the Pearson χ2 test showed significantly greater proportion of impingement of the humeral liner into the superior part of the glenoid neck in abduction occurring in the combination of the normal glenosphere and constrained humeral liner group compared with the other groups (P < .01). Bonferroni post hoc tests revealed that the combination of the normal glenosphere and constrained humeral liner was significantly different from that of the lateralized glenosphere and constrained humeral liner (P < .01). Using constrained liners resulted in early impingement on the superior part of the glenoid neck in the normal glenosphere, whereas glenoid lateralization increased impingement-free ROM. CONCLUSION: This RSA computer simulation model demonstrated that constrained humeral liners led to decreased impingement-free ROM. However, using the lateralized glenosphere improved abduction ROM.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Feminino , Artroplastia do Ombro/métodos , Articulação do Ombro/cirurgia , Simulação por Computador , Desenho de Prótese , Úmero/cirurgia , Amplitude de Movimento Articular
2.
J Arthroplasty ; 39(8): 2082-2087, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38360279

RESUMO

BACKGROUND: Hydroxyapatite-coated, triple-tapered, shorter-length stems with a medial collar have been reported with good results for a few years. We investigated whether contact between the medial collar and femoral neck affects clinical outcomes and changes in bone mineral density (BMD) in patients who have this type of stem in their total hip arthroplasty construct. METHODS: This was a retrospective, single-center study involving 62 patients scheduled for unilateral total hip arthroplasty using a hydroxyapatite-coated, triple-tapered, shorter-length stem who were followed for at least 1 year postoperatively. All patients had a Dorr type B femoral canal shape. Contact between the medial collar and the femoral neck was evaluated by computed tomography at the third postoperative month, and patients were classified into 2 groups. Postoperative clinical outcomes were investigated by the Western Ontario and McMaster Universities Arthritis Index and the Japanese Orthopaedic Association scores; radiological evaluation included stem fixation, spot welds and cortical hypertrophy, postoperative 3-dimensional stem alignment, and periprosthetic BMD changes. RESULTS: There were 51 patients in the Contact + group (collar and neck contact) and 11 in the Contact-group (no contact). There were no differences between the 2 groups in the improvement of Western Ontario and McMaster Universities Arthritis Index and Japanese Orthopaedic Association scores, stem fixation, occurrence of cortical hypertrophy, or 3-dimensional stem alignment. Radiolucent lines were present in zones 3, 4, and 5 in 6 patients (12%) in the Contact + group only, who had no statistical difference between the 2 groups. Bone mineral density (BMD) decreased most in zone 7 in both groups, with no difference between the 2 groups. CONCLUSIONS: The presence or absence of contact between the medial collar and femoral neck did not affect postoperative BMD changes or radiological or clinical results. LEVEL OF EVIDENCE: Therapeutic Level III.


Assuntos
Artroplastia de Quadril , Densidade Óssea , Durapatita , Colo do Fêmur , Prótese de Quadril , Desenho de Prótese , Humanos , Masculino , Feminino , Estudos Retrospectivos , Artroplastia de Quadril/instrumentação , Pessoa de Meia-Idade , Idoso , Colo do Fêmur/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Materiais Revestidos Biocompatíveis
3.
Arch Orthop Trauma Surg ; 144(6): 2865-2872, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38753013

RESUMO

INTRODUCTION: The accuracy of acetabular cup placement using conventional portable imageless navigation systems in total hip arthroplasty (THA) in the lateral decubitus position remains challenging. Several novel portable imageless navigation systems have been developed recently to improve cup placement accuracy in THA. This study compared the accuracy of acetabular cup placement using a conventional accelerometer-based portable navigation (c-APN) system and a novel accelerometer-based portable navigation (n-APN) system during THA in the lateral decubitus position. MATERIALS AND METHODS: This retrospective cohort study compared 45 THAs using the c-APN and 45 THAs using the n-APN system. The primary outcomes were the absolute errors between the intraoperative and postoperative values of acetabular cup radiographic inclination and anteversion angles and the percentage of cases with absolute errors within 5°. Intraoperative values were shown on navigation systems, and postoperative measurements were conducted using computed tomography images. RESULTS: The median absolute errors of the cup inclination angles were significantly smaller in the n-APN group than in the c-APN group (3.9° [interquartile range 2.2°-6.0°] versus 2.2° [interquartile range 1.0°-3.3°]; P = 0.002). Additionally, the median absolute errors of the cup anteversion angles were significantly smaller in the n-APN group than in the c-APN group (4.4° [interquartile range 2.4°-6.5°] versus 1.9° [interquartile range 0.8°-2.7°]; P < 0.001). Significant differences were observed in the percentage of cases with absolute errors within 5° of inclination (c-APN group 67% versus n-APN group 84%; P = 0.049) and anteversion angles (c-APN group 62% versus n-APN group 91%; P = 0.001). CONCLUSIONS: The n-APN system improved the accuracy of the cup placement compared to the c-APN system for THA in the lateral decubitus position.


Assuntos
Acelerometria , Acetábulo , Artroplastia de Quadril , Sistemas de Navegação Cirúrgica , Humanos , Artroplastia de Quadril/métodos , Artroplastia de Quadril/instrumentação , Estudos Retrospectivos , Acetábulo/cirurgia , Acetábulo/diagnóstico por imagem , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Acelerometria/métodos , Acelerometria/instrumentação , Posicionamento do Paciente/métodos , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/instrumentação , Prótese de Quadril , Tomografia Computadorizada por Raios X/métodos
4.
Eur J Orthop Surg Traumatol ; 34(4): 2041-2047, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38517525

RESUMO

PURPOSE: This study aimed to compare bone mineral density (BMD) changes around the femoral component after total hip arthroplasty (THA) in a fully hydroxyapatite-coated stem (CORAIL) and in a tapered-wedge stem (Taperloc complete) and identify predictors of BMD changes. METHODS: This retrospective study compared 43 hips in the CORAIL group and 40 hips in the Taperloc group. The relative changes in BMD at 2 years after THA measured using dual-energy X-ray absorptiometry and the three-dimensional quantified contact states of the stem with the femoral cortical bone were assessed. Predictors of the relative change in the BMD around the proximal part of the stem were examined using multiple regression analysis. RESULTS: The decrease in BMD in Gruen zone 7 was significantly less in the CORAIL group than in the Taperloc group (P = 0.02). In the CORAIL group, the contact area in any zone was not a significant predictor of the relative changes in BMD. The contact area between the Taperloc stem and the femoral cortical bone in zones 2 and 6 was a positive predictor of the relative changes in BMD in zones 1 (P = 0.02 and P = 0.04, respectively) and 2 (P = 0.008 and P = 0.004, respectively). CONCLUSION: The CORAIL stem suppressed the postoperative BMD loss around the stem, irrespective of the contact state. The Taperloc complete stem required contact with the proximal femoral metaphysis to suppress the postoperative BMD loss around the stem.


Assuntos
Absorciometria de Fóton , Artroplastia de Quadril , Densidade Óssea , Remodelação Óssea , Durapatita , Fêmur , Prótese de Quadril , Desenho de Prótese , Humanos , Masculino , Feminino , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Remodelação Óssea/fisiologia , Pessoa de Meia-Idade , Idoso , Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Materiais Revestidos Biocompatíveis
5.
Arch Orthop Trauma Surg ; 143(11): 6781-6790, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37418005

RESUMO

INTRODUCTION: It is preferable to reduce postoperative excessive rotational mismatch between the femur and tibia that causes poor clinical results following total knee arthroplasty (TKA). The aim of this study is to compare postoperative rotational mismatches and clinical outcomes with mobile- and fixed-bearing prostheses. MATERIALS AND METHODS: This study classified 190 TKAs into two groups equally by propensity score matching: mobile-bearing group (n = 95) and fixed-bearing group (n = 95). Computed tomography images of the whole leg were taken at 2 weeks postoperatively. The component alignments, rotational mismatches between the femur and tibia, and rotations among components were measured three-dimensionally. The knee range of motion, New Knee Society Score (KSS) subjective sores, and Forgotten Joint Score (FJS-12) were assessed at the final follow-up. RESULTS: Rotational mismatch between the femur and tibia was significantly less in the mobile- (- 0.8° ± 7.3°) than in the fixed-bearing (3.3° ± 8.5°, p < 0.001) group. New KSS functional activity score was significantly poorer in patients with excessive rotational mismatch (61.3 ± 21.4) than in those without it (49.5 ± 20.6, p = 0.02). Comparing mobile-bearing prosthesis, the use of fixed-bearing prosthesis was a risk factor for postoperative excessive rotational mismatch (odds ratio: 2.32, p = 0.03). CONCLUSION: When compared to a fixed-bearing prosthesis, TKA using a mobile-bearing prosthesis could suppress the postoperative rotational mismatch between the femur and tibia that causes poor subjective functional activity score. However, since this study was conducted for PS-TKA, the results might not be applicable to other models.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Osteoartrite do Joelho/cirurgia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Desenho de Prótese , Amplitude de Movimento Articular , Medidas de Resultados Relatados pelo Paciente
6.
Arch Orthop Trauma Surg ; 143(7): 4465-4472, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36261646

RESUMO

INTRODUCTION: It is clinically important to analyze the initial contact state between an implant and femoral cortical bone as it affects clinical outcomes, such as stress shielding, stem subsidence, thigh pain, and patient-reported outcomes after total hip arthroplasty. Whether the initial contact state of a double-tapered fully hydroxyapatite (HA)-coated stem is achieved with the preserved cancellous or cortical bone remains to be established. This study aimed to compare the contact area with the femoral cortical bone between a double-tapered fully HA-coated stem (HA group) and a tapered wedge cementless stem (TW group) using three-dimensional computed tomography (3DCT)-based templating software. MATERIALS AND METHODS: Forty-seven total hip arthroplasties in the HA and TW groups each were retrospectively analyzed. The contact area between the implant and femoral cortical bone in the whole stem and at each Gruen zone was measured using density mapping with 3DCT-based templating software. RESULTS: The demographic data were not significantly different between the two groups. The contact area in the whole stem area was lower in the HA group (HA 5.4 ± 1.8% vs. TW 9.0 ± 4.8%, p < 0.01). The HA group had a lower contact area in zone 2 (HA 6.7 ± 6.5% vs. TW 15.6 ± 10.8%, p < 0.01) and zone 6 (HA 1.8 ± 3.5% vs. TW 6.3 ± 3.6%, p < 0.01) than the TW group. The implant type (ß = 0.41, p < 0.01) and stem coronal alignment (ß = - 0.29, p < 0.01) were significant predictors of the contact area in the whole stem area in a multiple regression analysis (adjusted R2 = 0.27, p < 0.01). CONCLUSION: The contact area of the double-tapered fully HA-coated stem was significantly lower than that of the tapered wedge cementless stem.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Durapatita , Estudos Retrospectivos , Artroplastia de Quadril/métodos , Tomografia Computadorizada por Raios X/métodos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Osso Cortical/diagnóstico por imagem , Osso Cortical/cirurgia , Desenho de Prótese
7.
Arch Orthop Trauma Surg ; 143(7): 4473-4480, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36322198

RESUMO

INTRODUCTION: No studies have compared the accuracy of acetabular cup placement in total hip arthroplasty (THA) in the supine and lateral decubitus positions using the same portable navigation system. Thus, this study aimed to compare the accuracy of acetabular cup placement using a new accelerometer-based portable navigation system combined with an infrared stereo camera and inertial measurement unit between the supine and lateral decubitus positions. MATERIALS AND METHODS: This retrospective study compared 45 THAs performed in the supine position (supine group) and 44 THAs performed in the lateral decubitus position (lateral group) using the same portable navigation system. The primary outcome was the absolute errors of cup placement angles, defined as the absolute values of the differences between cup radiographic inclination and anteversion angles displayed on the navigation system and those measured on postoperative computed tomography images. RESULTS: No significant difference in the median absolute error of the cup inclination angle (supine group 1.7° [interquartile range 0.8°-3.1°] vs. lateral group 2.1° [interquartile range 1.0°-3.7°]; p = 0.07) was found between the two groups. Similarly, no significant difference in the median absolute error of the anteversion angle (supine group 1.9° [interquartile range 0.8°-3.4°] vs. lateral group 2.1° [interquartile range 0.9°-3.1°]; p = 0.42) was found. CONCLUSION: This new accelerometer-based portable navigation system may provide high accuracy of the cup placement in THA in the lateral decubitus and supine positions.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Cirurgia Assistida por Computador , Humanos , Artroplastia de Quadril/métodos , Decúbito Dorsal , Estudos Retrospectivos , Cirurgia Assistida por Computador/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Acelerometria
8.
Arch Orthop Trauma Surg ; 143(10): 6345-6351, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37103606

RESUMO

INTRODUCTION: Previous reports using cadaveric knees and musculoskeletal computer simulation have shown that kinematically aligned (KA) total knee arthroplasty (TKA) provides more natural and physiological tibiofemoral kinematic patterns than mechanically aligned (MA) TKA. These reports suggested that the modification of joint line obliquity improve the knee kinematics. This study aimed to determine whether joint line obliquity change the intraoperative tibiofemoral kinematics in TKA candidates with knee osteoarthritis. METHODS: Thirty consecutive knees with varus osteoarthritis that underwent TKA using a navigation system were evaluated. Two types of trial components were prepared: (1) MA TKA model: component trial in which articulating surface was parallel to the bone cut surface (2) KA TKA model: the femoral component trial, which mimicked the KA TKA method of Dossett et al. was designed 3° valgus and 3° internal rotation to the femoral bone cut surface, and the tibial component trial was designed 3° varus to the tibial bone cut surface. These two trials were set on the same knees during the operation, and the tibiofemoral rotational kinematics and varus-valgus laxity were measured from 0° to 120° of knee flexion using a navigation system. RESULTS: The joint gap was 20 ± 2 mm and 3° ± 1° varus in extension and 20 ± 2 mm and 3° ± 1°varus in flexion. The differences in femoral component rotation between KA TKA and MA TKA were not statistically significant for any knee flexion angle. The differences in varus-valgus laxity between KA TKA and MA TKA were also not statistically significant for any knee flexion angle. CONCLUSION: Although the degree of joint line obliquity varies widely in various KA TKA methods, this study, which mimicked the method of Dossett et al. showed that the modification of joint line obliquity did not change the tibiofemoral kinematics and stability of the knee joint in TKA candidates with knee osteoarthritis.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Osteoartrite do Joelho/cirurgia , Fenômenos Biomecânicos , Simulação por Computador , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Amplitude de Movimento Articular/fisiologia
9.
Biochem Biophys Res Commun ; 597: 58-63, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-35124460

RESUMO

Vitamin D has been shown to reduce symptoms in patients with osteoarthritis (OA). In a previous study, local administration of eldecalcitol, an active vitamin D3 analog, reduced degenerative changes in articular cartilage in the early phase of experimental OA. However, the target of vitamin D in OA remains unknown. Here, we investigated the effect of eldecalcitol treatment on chondrocytes, which were divided into superficial zone chondrocytes (SZC), deep zone chondrocytes (DZC), and differentiated chondrocytes. SZC and DZC were cultured in monolayer and 3D pellet cultures treated with eldecalcitol. The gene expressions of articular cartilage and chondrocyte differentiation markers were evaluated. Histological analysis of SZC and DZC 3D pellet cultures was performed. The results showed that the articular cartilage markers ETS-related gene (Erg) and lubricin/proteoglycan 4 (PRG4) were significantly increased in SZC, but not in DZC, in the monolayer culture treated with eldecalcitol. The chondrocyte differentiation markers type X collagen and alkaline phosphatase (ALP) were significantly decreased in the DZC pellet culture treated with eldecalcitol. Immunochemical analysis also showed that Erg and lubricin/PRG4 expressions were elevated in the SZC pellet culture treated with eldecalcitol, while type X collagen and ALP expressions were decreased in the DZC pellet culture treated with eldecalcitol. In conclusion, this study showed that eldecalcitol upregulated articular cartilage markers in SZC and suppressed differentiation markers in DZC. Such regulation of chondrocytes by eldecalcitol could be potentially effective against OA progression.

10.
Knee Surg Sports Traumatol Arthrosc ; 30(2): 734-739, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33492409

RESUMO

PURPOSE: Research has shown that a cemented mobile-bearing component has a favorable effect on the bone mineral density (BMD) of the distal femur at 2 years after total knee arthroplasty (TKA). This study was performed to determine whether the advantage on BMD of a cemented mobile-bearing TKA over a conventional cemented fixed-bearing TKA changes with time. This report is an update of a matched cohort study initiated in 2004 and for which the 2-year results have been published. METHODS: Twenty-eight knees that were treated with a fixed-bearing posterior stabilized (PS) prosthesis and 28 matched knees from a database of 76 knees that were treated with a mobile-bearing PS prosthesis in the same period were investigated. All knees underwent dual-energy X-ray absorptiometry (DEXA) scans around the femoral component preoperatively, 2 weeks postoperatively, 5 years postoperatively, and annually thereafter. Eighteen knees with a cemented mobile-bearing PS prosthesis and 20 knees with a cemented fixed-bearing PS prosthesis were investigated for more than 6 years. The mean follow-up period was 11 years. RESULTS: The range of motion, Knee Society Score, BMD of the lumbar spine, and follow-up period were not significantly different preoperatively and postoperatively in the two groups. In the fixed-bearing group, the BMD of the anterior part of the femoral condyle decreased postoperatively. In the mobile-bearing group, the BMD of the posterior part of the femoral condyle increased postoperatively. The postoperative change in the BMD at 5 years and the latest follow-up period was statistically significant in the two groups. CONCLUSIONS: This DEXA study revealed that a cemented mobile-bearing component had a favorable effect on the BMD of the distal femur after TKA even at a mean of 11 years postoperatively. LEVEL OF EVIDENCE: Therapeutic study, level II, prospective comparative study.


Assuntos
Prótese do Joelho , Osteoartrite do Joelho , Densidade Óssea , Estudos de Coortes , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Estudos Prospectivos , Desenho de Prótese , Amplitude de Movimento Articular
11.
J Arthroplasty ; 37(2): 279-285, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34793858

RESUMO

BACKGROUND: This study aimed to clarify differences in clinical results, including in patients' joint awareness, between cruciate-substituting (CS) and cruciate-retaining (CR) medial pivot total knee arthroplasty (TKA) over a 10-year follow-up. METHODS: A total of 333 TKAs were included in this study. There were 257 cases of CS and 76 cases of CR TKAs. Knee range of motion, Knee Society Score, and radiological outcomes were assessed. The patients' joint awareness was evaluated using the Forgotten Joint Score-12 at the final follow-up. The survival rate with respect to reoperation or revision was analyzed. RESULTS: The mean follow-up period was 10 ± 1.7 years, and the loss to follow-up was 5.4%. All clinical outcomes improved significantly after surgery in both groups (P < .001). Postoperative knee flexion was 118° ± 13° in the CS group and 116° ± 10° in the CR group (P = .10). The mean Forgotten Joint Score-12 scores were 57 ± 27 points in the CS group and 56 ± 28 points in the CR group (P = .59). Ten years after the operation, the survival rates for reoperation were 96.3% in the CS group and 94.2% in the CR group (P = .61), and those for revision were 98.4% and 98.7% in the CS and CR groups, respectively (P = .87). Other postoperative clinical results did not differ between the 2 groups. CONCLUSION: In this 10-year follow-up study, medial pivot TKA, regardless of polyethylene insert type, showed a high survival rate and good patient awareness of the prosthetic joint.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Ligamento Cruzado Posterior , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Ligamento Cruzado Posterior/cirurgia , Desenho de Prótese , Amplitude de Movimento Articular
12.
Arch Orthop Trauma Surg ; 142(8): 2057-2064, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34390387

RESUMO

INTRODUCTION: The medial pivot total knee arthroplasty (TKA) has good patients' satisfaction; however, there is likely the restriction of postoperative knee flexion. The 2nd generation medial pivot TKA prosthesis was designed to improve postoperative knee flexion. This study aimed to compare the clinical outcomes and patient satisfaction between the 2nd generation and 1st generation medial pivot TKA prostheses. MATERIALS AND METHODS: We conducted a retrospective study of 472 consecutive TKAs, performed using either the 2nd generation (EVOLUTION™), having smaller posterior femoral condyle and asymmetrical tibial tray, or 1st generation (ADVANCE™) prosthesis. The use of each system was historically determined. Patient age, sex and body mass index were matched between the two groups, with 157 cases ultimately included in each group. Measured clinical outcomes included: knee range of motion, the Knee Society Score, the rate of re-operation, and radiological parameters. Patient satisfaction was evaluated using the 12-item Forgotten Joint Score (FJS-12). RESULTS: The average follow-up period was 5.0 (3.7-6.3) years for the 2nd generation group and 8.7 (6.1-12.8) years for the 1st generation group (p < 0.01). The postoperative knee flexion range was 127° (80°-140°) for the 2nd generation and 118° (90°-135°) for the 1st generation at final follow-up (p < 0.01). On multivariate regression analysis, use of the 2nd generation prosthesis predicted greater postoperative knee flexion. The average FJS-12 score was 64 (0-100) for the 2nd generation and mean 57 (0-100) for the 1st generation (p < 0.01). Other clinical outcomes were similar between the two groups. CONCLUSIONS: Compared to the 1st generation, the 2nd generation medial pivot prosthesis provides greater postoperative knee flexion and patient satisfaction.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Estudos de Coortes , Seguimentos , Humanos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Satisfação do Paciente , Desenho de Prótese , Amplitude de Movimento Articular , Estudos Retrospectivos
13.
Eur J Orthop Surg Traumatol ; 32(3): 551-557, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34043059

RESUMO

PURPOSE: Medial pivot total knee arthroplasty (MP-TKA) is characterized by the ball-in-socket medial tibiofemoral articulation to achieve low wear and to reproduce the medial pivot motion similar to that in the normal knee, and there have been reports of favorable long-term postsurgical outcomes. However, most of these cases concerned varus knees, and the outcomes of MP-TKA in valgus knees are unknown. The objective of this study was to investigate the postoperative outcomes in end-stage valgus knee OA patients who underwent MP-TKA, through comparisons with those who underwent TKA using the same prosthesis for varus deformity. METHODS: This retrospective, single-center, cohort study analyzed 171 knees of 121 patients who were divided into two groups (valgus knee group: 15 knees (13 patients), varus knee group: 156 knees (109 patients)). Primary outcome measures included the knee joint range of motion (evaluated preoperatively and at every year postoperatively). Secondary outcomes included operative time, laboratory data, estimated blood loss, clinical outcome measures and adverse events. RESULTS: There were no significant differences in age, sex and body mass index, as well as in the postoperative primary and secondary outcome measures between the two groups. CONCLUSION: The use of MP-TKA featuring ball-in-socket medial tibiofemoral articulation in patients with valgus knee OA showed equally favorable clinical outcomes more than 2 years after surgery, compared to patients with varus knees who received MP-TKA.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Artroplastia do Joelho/efeitos adversos , Fenômenos Biomecânicos , Estudos de Coortes , Humanos , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Osteoartrite do Joelho/complicações , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular , Estudos Retrospectivos
14.
BMC Musculoskelet Disord ; 22(1): 94, 2021 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-33472600

RESUMO

BACKGROUND: Bone morphogenetic proteins (BMPs) induce osteogenesis in various environments. However, when BMPs are used alone in the bone marrow environment, the maintenance of new bone formation is difficult owing to vigorous bone resorption. This is because BMPs stimulate the differentiation of not only osteoblast precursor cells but also osteoclast precursor cells. The present study aimed to induce and maintain new bone formation using the topical co-administration of recombinant human BMP-2 (rh-BMP-2) and zoledronate (ZOL) on beta-tricalcium phosphate (ß-TCP) composite. METHODS: ß-TCP columns were impregnated with both rh-BMP-2 (30 µg) and ZOL (5 µg), rh-BMP-2 alone, or ZOL alone, and implanted into the left femur canal of New Zealand white rabbits (n = 56). The implanted ß-TCP columns were harvested and evaluated at 3 and 6 weeks after implantation. These harvested ß-TCP columns were evaluated radiologically using plane radiograph, and histologically using haematoxylin/eosin (H&E) and Masson's trichrome (MT) staining. In addition, micro-computed tomography (CT) was performed for qualitative analysis of bone formation in each group (n = 7). RESULTS: Tissue sections stained with H&E and MT dyes revealed that new bone formation inside the ß-TCP composite was significantly greater in those impregnated with both rh-BMP-2 and ZOL than in those from the other experimental groups at 3 and 6 weeks after implantations (p < 0.05). Micro-CT data also demonstrated that the bone volume and the bone mineral density inside the ß-TCP columns were significantly greater in those impregnated with both rh-BMP-2 and ZOL than in those from the other experimental groups at 3 and 6 weeks after implantations (p < 0.05). CONCLUSIONS: The topical co-administration of both rh-BMP-2 and ZOL on ß-TCP composite promoted and maintained newly formed bone structure in the bone marrow environment.


Assuntos
Medula Óssea , Proteína Morfogenética Óssea 2 , Osteogênese , Fator de Crescimento Transformador beta , Animais , Humanos , Coelhos , Proteínas Recombinantes , Microtomografia por Raio-X , Ácido Zoledrônico
15.
J Arthroplasty ; 36(3): 958-962, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32994112

RESUMO

BACKGROUND: Additional bone resection in the distal femur is performed to increase the extension joint gap in total knee arthroplasty (TKA). The present study aimed to analyze the relationship between the amount of additional bone resection in the distal femur and the increase in the extension joint gap in TKA. METHODS: Fifty knees undergoing TKA for varus osteoarthritis were evaluated. Two femoral trial component models were prepared: (1) a normal model with 9-mm-thick distal and posterior femoral components and (2) an additional bone resection model with a 5-mm-thick distal femoral component (9 mm to 4 mm) and a 9-mm-thick posterior femoral component, which simulated an additional bone cut in the distal femur of 4 mm. The femoral trial component models were set before implantation, and the extension joint gap was measured using a tensor device that had a shape identical to that of the fixed-bearing tibial insert. RESULTS: The additional bone resection model had a larger joint gap than the normal model (P < .01). The mean extension gap increase in the additional bone resection model was 2 (standard deviation 1) mm, which was less than the thickness of the additional bone resection (4 mm) (P < .01). CONCLUSION: The amount of additional bone resection in the distal femur was not equal to the increase in the extension joint gap. Additional bone resection of 4 mm in the distal femur only increased the extension joint gap by a mean of 2 mm.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Fêmur/cirurgia , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular
16.
Eur J Orthop Surg Traumatol ; 31(7): 1355-1361, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33502598

RESUMO

PURPOSE: Leg length discrepancy (LLD) after total hip arthroplasty (THA) prevents functional recovery and reduces patient satisfaction. We investigated impact of changes in patient-perceived LLD on patient satisfaction and walking ability. METHODS: one hundred and forty-nine patients with unilateral hip osteoarthritis undergoing THA from 2014 to 2017, (125 women, 24 men; average age, 68.5 years) with an objective LLD < 1 cm were included. Outcome measures included the patient-perceived LLD, Western Ontario and McMaster Universities Osteoarthritis (WOMAC) index, 10-m walking speed, and affected leg loading rate, assessed preoperatively and at 3 weeks, 3 months, and 1 year postoperatively. RESULTS: The absolute patient-perceived LLD (mean ± SD) (the number of patients with perceived LLD > 5 mm) were 6.4 ± 9.6 mm [88 patients (59%)] preoperatively; and 2.2 ± 4.0 mm [48 (32%); p < 0.001], 0.7 ± 2.3 mm [17 (11%); p < 0.001], and 0.4 ± 1.6 mm [10 (7%); p = 0.095] at 3 weeks, 3 months, and 1 year postoperatively, respectively. All outcome measures improved over time. One year postoperatively, a weak positive correlation between the patient-perceived LLD and WOMAC or 10-m walking speed (r = 0.24, 0.23, respectively) was found. The risk of patient-perceived LLD persisting > 1 year postoperatively was 5.5-fold higher in patients who exhibited it at 3 months and those with a WOMAC score > 10 at 3 months postoperatively, using multivariate logistic regression. CONCLUSION: Achieving a post-THA objective LLD < 1 cm significantly reduced the patient-perceived LLD up to 3 months postoperatively. The residual patient-perceived LLD at 1 year postoperatively was predicted from the WOMAC score or the presence of patient-perceived LLD at 3 months after THA. LEVEL OF EVIDENCE: Therapeutic level IV.


Assuntos
Artroplastia de Quadril , Osteoartrite do Quadril , Idoso , Artroplastia de Quadril/efeitos adversos , Feminino , Humanos , Perna (Membro) , Desigualdade de Membros Inferiores/etiologia , Desigualdade de Membros Inferiores/cirurgia , Masculino , Osteoartrite do Quadril/cirurgia , Satisfação do Paciente
17.
Knee Surg Sports Traumatol Arthrosc ; 28(10): 3226-3231, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31848651

RESUMO

PURPOSE: Previous cadaver studies showed that the additional bone cuts in the distal and posterior femur and joint line elevation resulted in laxity at mid-flexion after total knee arthroplasty (TKA). However, these results are not always applicable to TKA candidates because the related studies used cadaver knees with no osteoarthritis. It was hypothesized that the joint line elevation results in mid-flexion laxity after TKA in patients with knee osteoarthritis. The purpose of this study was to analyze the relationship between joint line elevation and mid-flexion laxity in patients with knee osteoarthritis. METHODS: 30 knees with varus osteoarthritis undergoing TKA were evaluated. Two femoral trial component models were prepared: (1) normal model with a thickness of the distal and posterior femoral components of 9 mm, and (2) 2-mm joint line elevation model with a thickness of the distal and posterior femoral components of 9 - 2 = 7 mm. This 2-mm joint line elevation model simulated an additional bone cut in the distal and posterior femur, and joint line elevation, without an additional bone cut. The femoral trial component models were set before implantation and measured the joint gap kinematics using a tensor device through the full knee range of motion. RESULTS: The differences in joint gap change from 30° to 90° were not statistically significant between the two models. However, the joint line elevation model decreased the joint gap laxity at 120° (p = 0.02) and at 145° (p = 0.01). CONCLUSIONS: This study showed that a 2-mm joint line elevation was not associated with mid-flexion laxity in patients with varus osteoarthritis in the knee. The results of this study differed from the results in previous cadaver studies. LEVEL OF EVIDENCE: Therapeutic study, level II, prospective comparative study.


Assuntos
Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Instabilidade Articular/fisiopatologia , Articulação do Joelho/fisiopatologia , Osteoartrite do Joelho/fisiopatologia , Osteoartrite do Joelho/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Humanos , Articulação do Joelho/cirurgia , Masculino , Complicações Pós-Operatórias/fisiopatologia , Estudos Prospectivos , Amplitude de Movimento Articular
18.
Knee Surg Sports Traumatol Arthrosc ; 28(5): 1560-1567, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31240377

RESUMO

PURPOSE: The accuracy of patient-specific instrumentation (PSI) in total knee arthroplasty (TKA) is still controversial, especially in the tibial prosthesis. It was hypothesized that the design modification of PSI improved the tibial prosthetic alignment and reduced the associated complications. The aim of this study was to compare the accuracy of a conventional PSI with that of a newly designed PSI for total knee arthroplasty (TKA) using a new three-dimensional (3D) measurement method. METHODS: Thirty TKAs each using the conventional and newly designed PSIs were studied. The postoperative 3D-computed tomography (3D CT) image was superimposed on the preoperative 3D CT plan. The absolute differences in the tibial prosthetic alignment between the preoperative and postoperative 3D CT images were directly measured in the coronal, sagittal, and axial planes. Knees in which the difference in the prosthetic alignment was > 3° were considered deviations. RESULTS: The new PSI showed less mean absolute differences and lower rate of deviations than the conventional PSI in the coronal and axial planes (p = 0.045 and p = 0.004, respectively). The deviations (> 3°) of the tibial prosthesis using the conventional PSI were 27, 30, and 63% and of those using the new PSI were 0, 20, and 20% in the coronal, sagittal, and axial planes, respectively. CONCLUSIONS: This is the first report to evaluate the effect of improvement in PSI design on the postoperative alignment using 3D method, and it clearly showed that the modification significantly improved the accuracy of alignment and reduced the deviations. LEVEL OF EVIDENCE: Therapeutic study, case-control study, Level III.


Assuntos
Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Tíbia/cirurgia , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Imageamento Tridimensional , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico por imagem , Modelagem Computacional Específica para o Paciente , Desenho de Prótese , Cirurgia Assistida por Computador , Tíbia/diagnóstico por imagem , Tomografia Computadorizada por Raios X
19.
Knee Surg Sports Traumatol Arthrosc ; 28(12): 3810-3820, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31996931

RESUMO

PURPOSE: This study aimed to identify factors associated with rotational mismatch after total knee arthroplasty (TKA) using fixed-bearing posterior stabilized prosthesis and to evaluate the impact of the rotational mismatch on clinical outcomes. METHODS: This retrospective cohort study included 159 cases that underwent TKA. Whole-leg computed tomography images were obtained 2 weeks after TKA, with three-dimensional measures of alignment. Rotational alignment of the femoral and tibial components and rotational mismatch between components and between the femur and tibia bones were evaluated. The new Knee Society Score (KSS) was obtained at the final outpatient visit, which was defined as the final follow-up timepoint. Predictive factors were identified for rotational mismatch of the lower extremity and poor new KSS. RESULTS: The mean follow-up period was 42 ± 16 months. Rotational mismatch ≥ 10° between bones was identified in 56 cases (35%), with a mean mismatch angle of 5.0° ± 9.1° of external rotation of the tibia relative to the femur. Rotational mismatch ≥ 10° between components was identified in three cases (2%; mean 0.3° ± 3.6° of internal tibial rotation). A multivariate regression analysis showed that component malrotation was predictive of post-operative rotational mismatch between bones (p < 0.01) and rotational mismatch ≥ 10° associated with poor new KSS (odds ratio 4.22; p < 0.01). CONCLUSION: Malrotation of the fixed-bearing posterior stabilized TKA causes a rotational mismatch between the femur and tibia bones. Excessive rotational mismatch between bones greater than 10° is a risk factor for poor postoperative functional outcome. Precise component positioning is essential for improving TKA outcomes. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho/efeitos adversos , Articulação do Joelho/fisiopatologia , Prótese do Joelho/efeitos adversos , Complicações Pós-Operatórias/etiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur/diagnóstico por imagem , Fêmur/fisiologia , Fêmur/cirurgia , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Complicações Pós-Operatórias/fisiopatologia , Estudos Retrospectivos , Rotação , Tíbia/diagnóstico por imagem , Tíbia/fisiologia , Tíbia/cirurgia , Tomografia Computadorizada por Raios X
20.
J Arthroplasty ; 35(11): 3156-3160, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32631727

RESUMO

BACKGROUND: Our previous study showed that the decrease in relative change of bone mineral density (BMD) in the lateral part of the tibia was significantly less in the group treated with the cementless porous tantalum component than in the group treated with the cemented cobalt-chromium tibial component up to 5 years after the operation. However, the long-term benefits of porous tantalum tibial component on BMD have not been proven. The aim of this study was to update a matched cohort study at a minimum of 6 years' follow-up period. METHODS: Twenty patients with a porous tantalum tibial component and 18 patients with a cemented cobalt-chromium-alloy tibial component were investigated for more than 6 years in the present study. The mean follow-up period was 11.4 years. Dual X-ray absorptiometry was used to measure the BMD. RESULTS: The decrease in relative change of BMD in the lateral aspect of the tibia was significantly less with the porous tantalum tibial component than that with the cemented cobalt-chromium tibial component up to 5 years. However, at the final follow-up period, no significant difference was observed in the relative change of BMD between the 2 groups. No prosthetic migration or periprosthetic fracture was detected in either group. CONCLUSION: The present study is one of the studies with the longest follow-up period on BMD after total knee arthroplasty. Porous tantalum tibial component did not have a favorable effect on the BMD of the proximal tibia after total knee arthroplasty for long term.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/efeitos adversos , Densidade Óssea , Estudos de Coortes , Seguimentos , Humanos , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Porosidade , Desenho de Prótese , Tantálio , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA