Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 21(22)2021 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-34833813

RESUMO

Atmospheric photoionization is a widely applied soft ionization mechanism in gas sensing devices for the detection of volatile organic compounds in ambient air. Photoionization is typically induced by low-pressure Vacuum Ultraviolet (VUV) lamps with MgF2 or LiF lamp surface windows depending on the gas fill and the required wavelength transmission window. These lamps are known to exhibit gradually reduced VUV transmission due to hydrocarbon contamination. LiF surface windows are known to be especially problematic due to their hygroscopic nature, reducing VUV lamp lifetime to a mere 100 h, approximately. Here, we present a new design for the electrode of a photoionization detector based on thin-film technology. By replacing the commonplace metal grid electrode's VUV lamp surface window with a chromium/gold thin film we obtain a doubling of photon efficiency for photoionization. Replacing the hygroscopic LiF lamp window surface with a metallic layer additionally offers the possibility to vastly increase operational lifetime of low-pressure Argon VUV lamps.

2.
Biochem Biophys Res Commun ; 529(2): 392-397, 2020 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-32703441

RESUMO

An understanding of the cell mechanical properties involved in numerous cellular processes including cell division, cell migration/invasion, and cell morphology, is crucial in developing and informing cell physiology and function. Atomic force microscopy (AFM) offers a powerful biophysical technique that facilitates the imaging of living cells under physiological buffer conditions. However, AFM in isolation cannot discriminate between different cell types within heterogeneous samples for example in a solid biopsy. The current studies demonstrate the potential of AFM in combination with correlative fluorescence optical sectioning microscopy for live cell imaging. Furthermore, this work establishes the advantage of fluorescence-AFM imaging to distinguish and analyse single-cell bio-physical properties in mixed human cell populations, in real-time. Critically, our results show that correlative fluorescence-AFM imaging allows the simultaneous co-localised detection of fluorescence coupled with nano-mechanical mapping. The findings from this work contribute to the promotion and dissemination of correlative multimodal imaging in life sciences, providing a platform for further investigations in biological and pre-clinical research.


Assuntos
Técnicas de Cocultura/métodos , Microscopia de Força Atômica/métodos , Microscopia de Fluorescência/métodos , Linhagem Celular , Sobrevivência Celular , Fluorescência , Humanos , Microscopia Confocal/métodos , Imagem Óptica/métodos
3.
Nanoscale ; 13(4): 2082-2099, 2021 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-33346312

RESUMO

With the invention of the Atomic Force Microscope (AFM) in 1986 and the subsequent developments in liquid imaging and cellular imaging it became possible to study the topography of cellular specimens under nearly physiological conditions with nanometric resolution. The application of AFM to biological research was further expanded with the technological advances in imaging modes where topographical data can be combined with nanomechanical measurements, offering the possibility to retrieve the biophysical properties of tissues, cells, fibrous components and biomolecules. Meanwhile, the quest for breaking the Abbe diffraction limit restricting microscopic resolution led to the development of super-resolution fluorescence microscopy techniques that brought the resolution of the light microscope comparable to the resolution obtained by AFM. The instrumental combination of AFM and optical microscopy techniques has evolved over the last decades from integration of AFM with bright-field and phase-contrast imaging techniques at first to correlative AFM and wide-field fluorescence systems and then further to the combination of AFM and fluorescence based super-resolution microscopy modalities. Motivated by the many developments made over the last decade, we provide here a review on AFM combined with super-resolution fluorescence microscopy techniques and how they can be applied for expanding our understanding of biological processes.


Assuntos
Biologia , Microscopia de Força Atômica , Microscopia de Fluorescência
4.
J Biophotonics ; 14(1): e202000200, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32827206

RESUMO

The development of nonviral gene delivery vehicles for therapeutic applications requires methods capable of quantifying the association between the genes and their carrier counterparts. Here we investigate the potential of fluorescence cross-correlation spectroscopy (FCCS) to characterize and optimize the assembly of nonviral cationic liposome (CL)-DNA complexes based on a CL formulation consisting of the cationic lipid DOTAP and zwitterionic lipid DOPC. We use a DNA plasmid for lipoplex loading encoding the Oct4 gene, critically involved in reprogramming somatic cells into induced pluripotent stem cells. We demonstrate that FCCS is able to quantitatively determine the extent of the association between DNA and the liposomes and assess its loading capacity. We also establish that the cationic lipid fraction, being proportional to the liposome membrane charge density, as well as charge ratio between the CLs and anionic DNA play an important role in the degree of interaction between the liposomes and DNA.


Assuntos
Lipossomos , Nanopartículas , DNA/genética , Espectrometria de Fluorescência , Transfecção
5.
MethodsX ; 7: 100931, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32528863

RESUMO

(3-aminopropyl)triethoxysilane (APTES) is a commonly used organosilane on surface functionalization of silicon oxide surfaces. However, its deposition process from solution-phase usually involves the use of toluene, which has often been identified as crucial for the formation of an aminopropylsilane monolayer. Toluene is ranked as a problematic solvent in the guide developed by a group referred to as the solvent sub-team of CHEM21. In this work, we propose a facile synthetic route for functionalizing a silicon substrate with APTES via solution-phase approach using only solvents that are classified as recommended. The influence of the APTES concentration, reaction times and different post-deposition conditions using acetic acid and methanol were studied in order to evaluate the quality and thickness of the organosilane layers.•The method uses ethanol as APTES solvent for functionalizing silicon dioxide surfaces and only uses solvents classified as recommended.•The method uses a solution phase approach, does not require complicated equipment and can be prepared at room temperature.

6.
Sci Rep ; 10(1): 1122, 2020 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-31980680

RESUMO

Correlating data from different microscopy techniques holds the potential to discover new facets of signaling events in cellular biology. Here we report for the first time a hardware set-up capable of achieving simultaneous co-localized imaging of spatially correlated far-field super-resolution fluorescence microscopy and atomic force microscopy, a feat only obtained until now by fluorescence microscopy set-ups with spatial resolution restricted by the Abbe diffraction limit. We detail system integration and demonstrate system performance using sub-resolution fluorescent beads and applied to a test sample consisting of human bone osteosarcoma epithelial cells, with plasma membrane transporter 1 (MCT1) tagged with an enhanced green fluorescent protein (EGFP) at the N-terminal.

7.
Anal Bioanal Chem ; 391(3): 943-50, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18157524

RESUMO

The impact of advances in nanotechnology is particularly relevant in biodiagnostics, where nanoparticle-based assays have been developed for specific detection of bioanalytes of clinical interest. Gold nanoparticles show easily tuned physical properties, including unique optical properties, robustness, and high surface areas, making them ideal candidates for developing biomarker platforms. Modulation of these physicochemical properties can be easily achieved by adequate synthetic strategies and give gold nanoparticles advantages over conventional detection methods currently used in clinical diagnostics. The surface of gold nanoparticles can be tailored by ligand functionalization to selectively bind biomarkers. Thiol-linking of DNA and chemical functionalization of gold nanoparticles for specific protein/antibody binding are the most common approaches. Simple and inexpensive methods based on these bio-nanoprobes were initially applied for detection of specific DNA sequences and are presently being expanded to clinical diagnosis. Figure Colorimetric DNA/RNA detection using salt induced aggregation of AuNP-DNA nanoprobes.


Assuntos
Técnicas Biossensoriais/métodos , DNA/análise , Ouro/química , Nanopartículas Metálicas/química , Nanotecnologia/métodos , RNA/análise , Técnicas Biossensoriais/instrumentação , Testes de Química Clínica/instrumentação , Testes de Química Clínica/métodos , Humanos , Imunoensaio/instrumentação , Imunoensaio/métodos , Nanotecnologia/instrumentação , Sensibilidade e Especificidade , Propriedades de Superfície
8.
Rev Sci Instrum ; 87(4): 043701, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27131681

RESUMO

Optical anisotropy of thin films has been widely investigated through ellipsometry, whereby typically an optical signal is averaged over a ∼1 cm(2) elliptical area that extends with increasing angle-of-incidence (AOI). Here, we report on spectroscopic imaging ellipsometry at the solid-liquid interface applied to a supported lipid bilayer (SLB). We detail how a differential spectrally resolved ellipsometry measurement, between samples with and without optically anisotropic thin film on an absorbing substrate, can be applied to recover in and out of plane refractive indices of the thin film with known film thickness, hence determining the thin film optical anisotropy. We also present how optimal wavelength and AOI settings can be determined ensuring low parameter cross correlation between the refractive indices to be determined from a differential measurement in Δ ellipsometry angle. Furthermore, we detail a Monte Carlo type analysis that allows one to determine the minimal required optical ellipsometry resolution to recover a given thin film anisotropy. We conclude by presenting a new setup for a spectroscopic imaging ellipsometry based on fiber supercontinuum laser technology, multi-wavelength diode system, and an improved liquid cell design, delivering a 5 ×-10 × ellipsometric noise reduction over state-of-the-art. We attribute this improvement to increased ellipsometer illumination power and a reduced light path in liquid through the use of a water dipping objective.

9.
Rev Sci Instrum ; 86(9): 093705, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26429446

RESUMO

Combined microscopy techniques offer the life science research community a powerful tool to investigate complex biological systems and their interactions. Here, we present a new combined microscopy platform based on fluorescence optical sectioning microscopy through aperture correlation microscopy with a Differential Spinning Disk (DSD) and nanomechanical mapping with an Atomic Force Microscope (AFM). The illumination scheme of the DSD microscope unit, contrary to standard single or multi-point confocal microscopes, provides a time-independent illumination of the AFM cantilever. This enables a distortion-free simultaneous operation of fluorescence optical sectioning microscopy and atomic force microscopy with standard probes. In this context, we discuss sample heating due to AFM cantilever illumination with fluorescence excitation light. Integration of a DSD fluorescence optical sectioning unit with an AFM platform requires mitigation of mechanical noise transfer of the spinning disk. We identify and present two solutions to almost annul this noise in the AFM measurement process. The new combined microscopy platform is applied to the characterization of a DOPC/DOPS (4:1) lipid structures labelled with a lipophilic cationic indocarbocyanine dye deposited on a mica substrate.

10.
Nanoscale ; 2(10): 2209-16, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20714654

RESUMO

A photocatalytic approach was used to synthesize triangular nanoplates in aqueous solution. The synthesis is based on the reduction of a gold salt using a tin(iv) porphyrin as photocatalyst, cetyltrimethylammonium bromide (CTAB) as a stabilizing agent, and triethanolamine (TEA) as the final electron donor. The average edge length of the triangular nanoplates can be easily changed in the range 45-250 nm by varying the concentration of photocatalyst, and fine-tuning of the average edge length is achieved by varying the concentration of CTAB. Study of the mechanism of formation of the nanoplates by UV-vis and by transmission electron microscopy (TEM) shows that there is a first stage where formation of 5 nm seeds takes place, further growth is probably by fusion and by direct reduction of gold onto the preformed nanoparticles. The nanoparticles formed during the photocatalytic reduction of the gold precursor show an irregular shape that evolves to regular triangular nanoplates after ripening in solution for 24 h.


Assuntos
Ouro/química , Nanopartículas Metálicas/química , Nanotecnologia/métodos , Anisotropia , Condutividade Elétrica , Elétrons , Etanolaminas/química , Cinética , Teste de Materiais , Microscopia Eletrônica de Transmissão/métodos , Modelos Químicos , Espectrofotometria Ultravioleta/métodos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA