RESUMO
BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).
Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Masculino , Feminino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Resultado do Tratamento , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Idoso , Fatores de Risco , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Fatores de Tempo , Idoso de 80 Anos ou mais , Próteses Valvulares Cardíacas , Estudos de Viabilidade , Medição de Risco , Desenho de Prótese , Ecocardiografia TridimensionalRESUMO
BACKGROUND: Surgical management of isolated tricuspid regurgitation (TR) is associated with high morbidity and mortality, thereby creating a significant need for a lower-risk transcatheter solution. OBJECTIVES: The single-arm, multicenter, prospective CLASP TR (Edwards PASCAL TrAnScatheter Valve RePair System in Tricuspid Regurgitation [CLASP TR] Early Feasibility Study) evaluated 1-year outcomes of the PASCAL transcatheter valve repair system (Edwards Lifesciences) to treat TR. METHODS: Study inclusion required a previous diagnosis of severe or greater TR and persistent symptoms despite medical treatment. An independent core laboratory evaluated echocardiographic results, and a clinical events committee adjudicated major adverse events. The study evaluated primary safety and performance outcomes, with echocardiographic, clinical, and functional endpoints. Study investigators report 1-year all-cause mortality and heart failure hospitalization rates. RESULTS: Sixty-five patients were enrolled: mean age of 77.4 years; 55.4% female; and 97.0% with severe to torrential TR. At 30 days, cardiovascular mortality was 3.1%, the stroke rate was 1.5%, and no device-related reinterventions were reported. Between 30 days and 1 year, there were an additional 3 cardiovascular deaths (4.8%), 2 strokes (3.2%), and 1 unplanned or emergency reintervention (1.6%). One-year postprocedure, TR severity significantly reduced (P < 0.001), with 31 of 36 (86.0%) patients achieving moderate or less TR; 100% had at least 1 TR grade reduction. Freedom from all-cause mortality and heart failure hospitalization by Kaplan-Meier analyses were 87.9% and 78.5%, respectively. Their New York Heart Association functional class significantly improved (P < 0.001) with 92% in class I or II, 6-minute walk distance increased by 94 m (P = 0.014), and overall Kansas City Cardiomyopathy Questionnaire scores improved by 18 points (P < 0.001). CONCLUSIONS: The PASCAL system demonstrated low complication and high survival rates, with significant and sustained improvements in TR, functional status, and quality of life at 1 year. (Edwards PASCAL TrAnScatheter Valve RePair System in Tricuspid Regurgitation [CLASP TR] Early Feasibility Study [CLASP TR EFS]; NCT03745313).