Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Bone Miner Metab ; 40(4): 648-656, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35546371

RESUMO

PURPOSE: To evaluate the utility of vertebral Hounsfield unit (HU) values from computed tomography (CT) in cancer staging as a supplementary screening tool for bone health among prostate cancer (PCa) patients. METHODS: T-scores of bone mineral density (BMD) in each lumbar vertebra (L1-L4) and hip for newly diagnosed PCa patients (N = 139) were measured using dual-energy X-ray absorptiometry (DXA). The degenerative changes in each lumbar vertebra were assessed, and the HU values of trabecular bone in axial CT images of each vertebral body (vertebral CT-HU value) were measured using staging CT. RESULTS: 556 vertebrae were analyzed. 326 of 556 (59%) lumbar vertebrae had degenerative changes. The vertebral CT-HU value was positively correlated with the lumbar BMD T-score, with higher correlation coefficients observed in vertebrae without degenerative changes (r = 0.655, N = 230) when compared to vertebrae with degenerative changes (r = 0.575, N = 326). The thresholds matching BMD T-scores of - 2.0 and - 1.5 set by cancer treatment-induced bone loss guidelines were 95 HU and 105 HU, respectively. Based on the intervention threshold (lumbar BMD T-score < - 1.5), 15.1% of PCa patients required osteoporosis treatment; and, this value increased to 30.9% when L1-L4 CT-HU thresholds that corresponded to BMD T-score < - 1.5 were used. CONCLUSION: Lumbar BMD values from DXA may not reflect true bone health in PCa patients who often have lumbar degenerative diseases. Thresholds based on the vertebral CT-HU value can be used as a supplementary method to identify PCa patients who need anti-osteoporosis drugs.


Assuntos
Densidade Óssea , Neoplasias da Próstata , Absorciometria de Fóton/métodos , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Estadiamento de Neoplasias , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/fisiopatologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
2.
Hinyokika Kiyo ; 68(8): 271-275, 2022 Aug.
Artigo em Japonês | MEDLINE | ID: mdl-36071019

RESUMO

A 74-year-old patient was undergoing treatment for ascending colon cancer (cT4aN2M1a) in the Department of Surgery at our hospital. During treatment for increased lymph node metastasis and spinal metastasis, she complained of numbness in her dorsal thigh. Magnetic resonance imaging showed spinal canal stenosis due to L4 bone metastasis. Immediately after starting radiation therapy for L4 bone metastasis, bladder rupture occurred and led to generalized peritonitis. We performed emergency laparotomy and drainage. Later, the patient's general condition improved, but irreversible neurological symptoms remained, and activities of daily living decreased markedly. This was thought to be caused by weakening of the bladder wall due to chronic cystitis, and hyperextension of the bladder due to neurogenic bladder. Bacteriuria leaked into the abdominal cavity, resulting in generalized peritonitis.


Assuntos
Neoplasias Colorretais , Cistite , Peritonite , Neoplasias da Coluna Vertebral , Atividades Cotidianas , Idoso , Neoplasias Colorretais/complicações , Cistite/complicações , Feminino , Humanos , Peritonite/diagnóstico , Peritonite/etiologia , Neoplasias da Coluna Vertebral/complicações , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Bexiga Urinária
3.
Sci Rep ; 14(1): 15445, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38965408

RESUMO

Conventional light diffusers have periodic surface profiles, periodic refractive index distributions, or light scattering layers containing colloids. In all such structures the optical directivity of the light diffuser is cannot typically be controlled. Here we propose an electrically tunable light diffuser based on the application of ultrasound to a nematic liquid crystal (LC) material. The ultrasonic LC diffuser consists of an LC layer sandwiched by two glass discs and an ultrasonic transducer. The electrodes of the transducer are divided in a circumferential direction so that a resonant non-coaxial flexural vibration mode can be generated on the diffuser by controlling the electrical input signals. A continuous reversed-phase sinusoidal electric signal to the transducer generates the non-coaxial resonant flexural vibration mode on the glass disc, inducing an acoustic radiation force acting on the boundary between the LC layer and glass discs. This effect changes the molecular orientation of the LC and the transmitted light distribution. The diffusion angle of the transmitted light depends on the input voltage amplitude, and the diffusion angle was maximized at 16.0 V. The vibrational distribution and the diffusion directivity could be rotated by adjusting the input voltages to different electrodes, meaning that an ultrasonic LC diffuser with a thin structure and no moving mechanical parts provided a tunable light-diffusing functionality with rotatable directivity.

4.
Adv Urol ; 2024: 9331738, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38389652

RESUMO

Objectives: In Japan, caudal block with 1% lidocaine is commonly used for transrectal prostate biopsy. Although 10 mL of 1% lidocaine is commonly used, the appropriate dosage of 1% lidocaine has not been studied. Our hospital routinely uses two different doses (5 or 10 mL) of 1% lidocaine for caudal block for transrectal prostate biopsy. Herein, we retrospectively evaluated the efficacy and safety of both doses of 1% lidocaine. Methods: This retrospective study included 869 patients who underwent transrectal prostate biopsy with caudal block at our hospital. The amount of 1% lidocaine was determined by the day of the week on which the biopsy was performed, and the patient voluntarily chose the day of the biopsy, unaware of the dose of 1% lidocaine used on that day. Pain, anal sphincter tonus, cancer diagnosis rate, and early complications were compared. Results: In total, 466 and 403 patients received 5 and 10 mL of 1% lidocaine for a caudal block, respectively. After propensity-score matching for patient characteristics, each group contained 395 patients. The pain score, anal sphincter tonus score, or prostate cancer diagnosis rate were not significantly different between the two groups. However, rectal bleeding was significantly more frequent and severe in the 10-mL than the 5-mL group (p=0.018 and p=0.0036, respectively). The incidence of other complications was not significantly different between the groups. Conclusions: Our results suggest that 5 mL of 1% lidocaine may be more suitable than 10 mL for caudal block during transrectal prostate biopsy.

5.
Res Rep Urol ; 15: 395-401, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37638329

RESUMO

Radiation-induced hemorrhagic cystitis is a refractory disease that can cause severe hematuria and bladder tamponade. Bladder tamponade due to radiation-induced hemorrhagic cystitis can often recur repeatedly and markedly reduce the quality of life. However, no blood test parameter has been studied yet regarding the prevention of bladder tamponade recurrence. An 84-year-old patient with a history of radiation therapy for cervical cancer was repeatedly hospitalized for bladder tamponade due to radiation-induced hemorrhagic cystitis. At each hospitalization, blood transfusions were performed to treat severe anemia as the first treatment, resulting in hematuria improvement, and the patient was discharged without invasive treatments such as transurethral coagulation. However, anemia developed gradually after each discharge. The anemia progression was obviously unrelated to macrohematuria because macrohematuria did not appear during that period. When the serum hemoglobin level decreased below the physiological range, bladder tamponade recurred. Based on these findings, we posited that the monitoring of the serum hemoglobin level could be useful to predict the occurrence of bladder tamponade. We hypothesized that if the serum hemoglobin level did not fall below the physiological range, bladder tamponade would not occur. We treated chronic anemia after determining its cause and kept serum hemoglobin levels within the physiological range. Since the treatment was initiated, bladder tamponade has not recurred in over 27 months. In this case, the monitoring of the serum hemoglobin level was useful to predict the occurrence of bladder tamponade due to radiation-induced hemorrhagic cystitis. By maintaining serum hemoglobin levels within the physiological range, we successfully prevented the recurrence of bladder tamponade due to radiation-induced hemorrhagic cystitis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA