Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Transfusion ; 62(4): 770-782, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35274303

RESUMO

BACKGROUND: In hematologic and transfusion medicine research, measurement of red blood cell (RBC) in vivo kinetics must be safe and accurate. Recent reports indicate use of biotin-labeled RBC (BioRBC) to determine red cell survival (RCS) offers substantial advantages over 51 Cr and other labeling methods. Occasional induction of BioRBC antibodies has been reported. STUDY DESIGN AND METHODS: To investigate the causes and consequences of BioRBC immunization, we reexposed three previously immunized adults to BioRBC and evaluated the safety, antibody emergence, and RCS of BioRBC. RESULTS: BioRBC re-exposure caused an anamnestic increase of plasma BioRBC antibodies at 5-7 days; all were subclass IgG1 and neutralized by biotinylated albumin, thus indicating structural specificity for the biotin epitope. Concurrently, specific antibody binding to BioRBC was observed in each subject. As biotin label density increased, the proportion of BioRBC that bound increased antibody also increased; the latter was associated with proportional accelerated removal of BioRBC labeled at density 6 µg/mL. In contrast, only one of three subjects exhibited accelerated removal of BioRBC density 2 µg/mL. No adverse clinical or laboratory events were observed. Among three control subjects who did not develop BioRBC antibodies following initial BioRBC exposure, re-exposure induced neither antibody emergence nor accelerated BioRBC removal. DISCUSSION: We conclude re-exposure of immunized subjects to BioRBC can induce anamnestic antibody response that can cause an underestimation of RCS. To minimize chances of antibody induction and underestimation of RCS, we recommend an initial BioRBC exposure volume of ≤10 mL and label densities of ≤18 µg/mL.


Assuntos
Biotina , Eritrócitos , Adulto , Anticorpos/metabolismo , Biotina/química , Sobrevivência Celular , Contagem de Eritrócitos , Eritrócitos/metabolismo , Humanos
2.
Transfusion ; 58(2): 352-358, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29193118

RESUMO

BACKGROUND: Critically ill preterm very-low-birthweight (VLBW) neonates (birthweight ≤ 1.5 kg) frequently develop anemia that is treated with red blood cell (RBC) transfusions. Although RBCs transfused to adults demonstrate progressive decreases in posttransfusion 24-hour RBC recovery (PTR24 ) during storage-to a mean of approximately 85% of the Food and Drug Administration-allowed 42-day storage-limited data in infants indicate no decrease in PTR24 with storage. STUDY DESIGN AND METHODS: We hypothesized that PTR24 of allogeneic RBCs transfused to anemic VLBW newborns: 1) will be greater than PTR24 of autologous RBCs transfused into healthy adults and 2) will not decrease with increasing storage duration. RBCs were stored at 4°C for not more than 42 days in AS-3 or AS-5. PTR24 was determined in 46 VLBW neonates using biotin-labeled RBCs and in 76 healthy adults using 51 Cr-labeled RBCs. Linear mixed-model analysis was used to estimate slopes and intercepts of PTR24 versus duration of RBC storage. RESULTS: For VLBW newborns, the estimated slope of PTR24 versus storage did not decrease with the duration of storage (p = 0.18) while for adults it did (p < 0.0001). These estimated slopes differed significantly in adults compared to newborns (p = 0.04). At the allowed 42-day storage limit, projected mean neonatal PTR24 was 95.9%; for adults, it was 83.8% (p = 0.0002). CONCLUSIONS: These data provide evidence that storage duration of allogeneic RBCs intended for neonates can be increased without affecting PTR24 . This conclusion supports the practice of transfusing RBCs stored up to 42 days for small-volume neonatal transfusions to limit donor exposure.


Assuntos
Preservação de Sangue , Transfusão de Sangue Autóloga , Transfusão de Eritrócitos , Eritrócitos , Recém-Nascido de Baixo Peso , Recém-Nascido Prematuro , Adulto , Feminino , Humanos , Recém-Nascido , Masculino , Fatores de Tempo
3.
Transfusion ; 58(8): 2068-2081, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29770455

RESUMO

The current reference method in the United States for measuring in vivo population red blood cell (RBC) kinetics utilizes chromium-51 (51 Cr) RBC labeling for determining RBC volume, 24-hour posttransfusion RBC recovery, and long-term RBC survival. Here we provide evidence supporting adoption of a method for kinetics that uses the biotin-labeled RBCs (BioRBCs) as a superior, versatile method for both regulatory and investigational purposes. RBC kinetic analysis using BioRBCs has important methodologic, analytical, and safety advantages over 51 Cr-labeled RBCs. We critically review recent advances in labeling human RBCs at multiple and progressively lower biotin label densities for concurrent, accurate, and sensitive determination of both autologous and allogeneic RBC population kinetics. BioRBC methods valid for RBC kinetic studies, including successful variations used by the authors, are presented along with pharmacokinetic modeling approaches for the accurate determination of RBC pharmacokinetic variables in health and disease. The advantages and limitations of the BioRBC method-including its capability of determining multiple BioRBC densities simultaneously in the same individual throughout the entire RBC life span-are presented and compared with the 51 Cr method. Finally, potential applications and limitations of kinetic BioRBC determinations are discussed.


Assuntos
Biotinilação/métodos , Eritrócitos/metabolismo , Cinética , Prática Clínica Baseada em Evidências , Humanos
4.
J Nutr ; 147(8): 1487-1492, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28701385

RESUMO

Although frank symptomatic biotin deficiency is rare, some evidence suggests that marginal biotin deficiency occurs spontaneously in a substantial proportion of women during normal human pregnancy and might confer an increased risk of birth defects. Herein I review 1) advances in assessing biotin status, including the relation between acylcarnitine excretion and biotin status; 2) recent studies of biotin status in pregnancy; 3) advances in understanding the role of biotin in gene expression and the potential roles of biotinylated proteins that are neither histones nor carboxylases; and 4) novel large-dose biotin supplementation as therapy for multiple sclerosis. The review concludes with a summary of recent studies that have reported potentially dangerous erroneous results in individuals consuming large amounts of biotin for measurements of various plasma hormones for common clinical assays that use streptavidin-biotin technology.


Assuntos
Biotina , Expressão Gênica/efeitos dos fármacos , Esclerose Múltipla/tratamento farmacológico , Estado Nutricional , Complicações na Gravidez/prevenção & controle , Complexo Vitamínico B , Animais , Biotina/sangue , Biotina/deficiência , Biotina/farmacologia , Biotina/uso terapêutico , Biotinilação , Carnitina/análogos & derivados , Carnitina/metabolismo , Feminino , Hormônios , Humanos , Esclerose Múltipla/sangue , Gravidez , Complicações na Gravidez/sangue , Estreptavidina , Complexo Vitamínico B/sangue , Complexo Vitamínico B/farmacologia , Complexo Vitamínico B/uso terapêutico
5.
Transfusion ; 57(6): 1488-1496, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28261808

RESUMO

BACKGROUND: Biotin-labeled red blood cells (BioRBCs) are used for in vivo kinetic studies. Because BioRBC dosing occasionally induces antibodies, a sensitive and specific anti-BioRBC detection assay is needed. STUDY DESIGN AND METHODS: Aims were to 1) develop a gel card assay to evaluate existing, naturally occurring and BioRBC-induced plasma antibodies, 2) compare gel card and tube agglutination detection results, and 3) test for a relationship of antibody induction and BioRBC dose. Reagent BioRBCs were prepared using sulfo-NHS biotin ranging from densities 18 (BioRBC-18) to 1458 (BioRBC-1458) µg/mL RBCs. RESULTS: Among BioRBC-exposed subjects, gel card and tube agglutination results were concordant in 21 of 22 adults and all 19 infant plasma samples. Gel card antibody detection sensitivity was more than 10-fold greater than tube agglutination. Twelve to 16 weeks after BioRBC exposure, induced anti-antibodies were detected by gel card in three of 26 adults (12%) at reagent densities BioRBC-256 or less, but in none of 41 infants. Importantly, induced anti-BioRBC antibodies were associated with higher BioRBC dose (p = 0.008); no antibodies were detected in 18 subjects who received BioRBC doses less than or equal to BioRBC-18. For noninduced BioRBC antibodies, six of 1125 naïve adults (0.3%) and none of 46 naïve infants demonstrated existing anti-BioRBC antibodies using reagent BioRBC-140 or -162. Existing anti-BioRBCs were all neutralized by biotin compounds, while induced antibodies were not. CONCLUSIONS: The gel card assay is more sensitive than the tube agglutination assay. We recommend reagent BioRBC-256 for identifying anti-BioRBCs. Use of a low total RBC biotin label dose (≤ BioRBC-18) may minimize antibody induction.


Assuntos
Anticorpos/imunologia , Biotina/química , Eritrócitos/imunologia , Adulto , Testes de Aglutinação , Bioensaio/métodos , Biotinilação , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Succinimidas/química
6.
Pediatr Res ; 81(6): 905-910, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28099421

RESUMO

BACKGROUND: Prior conclusions that autologous neonatal red blood cells (RBC) have substantially shorter lifespans than allogeneic adult RBCs were not based on direct comparison of autologous neonatal vs. allogeneic adult RBCs performed concurrently in the same infant. Biotin labeling of autologous neonatal RBCs and allogeneic adult donor RBCs permits concurrent direct comparison of autologous vs. allogeneic RBC lifespan. METHODS: RBCs from 15 allogeneic adult donors and from 15 very-low-birth-weight (VLBW) neonates were labeled at separate biotin densities and transfused simultaneously into the 15 neonates. Two mathematical models that account for the RBC differences were employed to estimate lifespans for the two RBC populations. RESULTS: Mean ± SD lifespan for adult allogeneic RBC was 70.1 ± 19.1 d, which is substantially shorter than the 120 d lifespan of both autologous and adult allogeneic RBC in healthy adults. Mean ± SD lifespan for neonatal RBC was 54.2 ± 11.3 d, which is only about 30% shorter than that of the adult allogeneic RBCs. CONCLUSION: This study provides evidence that extrinsic environmental factors primarily determine RBC survival (e.g., small bore of the capillaries of neonates, rate of oxygenation/deoxygenation cycles) rather than factors intrinsic to RBC.


Assuntos
Anemia/sangue , Biotina/metabolismo , Envelhecimento Eritrocítico , Adulto , Feminino , Humanos , Recém-Nascido , Masculino
7.
Transfusion ; 56(6): 1362-9, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27040455

RESUMO

BACKGROUND: It is thought that the clearance of transfused red blood cells (RBCs) is related both to the storage time of the transfusion product and to the inflammatory status of the recipient. We investigated these effects in a randomized, "two-hit," healthy volunteer transfusion model, comparing autologous RBCs that were stored for 35 days with those that were stored for 2 days. STUDY DESIGN AND METHODS: Healthy male volunteers donated 1 unit of autologous RBCs either 2 days (2D) or 35 days (35D) before the study date. The experiment was started by infusion of 2 ng/kg lipopolysaccharide ("first hit"). Two hours later, the stored RBCs ("second hit") were reinfused, followed by the labeling of RBCs with biotin. Clearance of biotin-labeled RBCs (BioRBCs) was measured during the 5-hour posttransfusion endotoxemia period along with measurements of phosphatidylserine (PS) exposure, lactadherin binding, and expression of CD47 (cluster of differentiation 47; a transmembrane protein encoded by the CD47 gene). RESULTS: In the 2D stored RBCs group, 1.5% ± 3.4% of infused BioRBCs were cleared from the circulation 5 hours posttransfusion versus 4.8% ± 4.0% in the 35D stored RBCs group (p = 0.1). There were no differences in PS exposure, lactadherin binding, or CD47 expression between fresh and stored RBCs or between pretransfusion and posttransfusion measurements. CONCLUSION: Our study shows a low clearance of RBCs even during endotoxemia. Furthermore, short-term clearance of BioRBCs during endotoxemia was not related to storage duration. Consistent with these observations, PS exposure, lactadherin binding, and CD47 expression did not differ between 2D and 35D stored cells before or after transfusion. We conclude that, in the presence of endotoxemia, clearance of 35D stored autologous RBCs is not increased compared with 2D stored fresh RBCs.


Assuntos
Preservação de Sangue , Endotoxemia/etiologia , Transfusão de Eritrócitos/efeitos adversos , Adolescente , Adulto , Antígenos de Superfície/metabolismo , Antígeno CD47/metabolismo , Voluntários Saudáveis , Humanos , Lipopolissacarídeos , Masculino , Taxa de Depuração Metabólica , Proteínas do Leite/metabolismo , Países Baixos , Fosfatidilserinas/metabolismo , Adulto Jovem
8.
J Pharmacokinet Pharmacodyn ; 43(3): 259-74, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27039311

RESUMO

The lifespan of red blood cells (RBCs) plays an important role in the study and interpretation of various clinical conditions. Yet, confusion about the meanings of fundamental terms related to cell survival and their quantification still exists in the literature. To address these issues, we started from a compartmental model of RBC populations based on an arbitrary full lifespan distribution, carefully defined the residual lifespan, current age, and excess lifespan of the RBC population, and then derived the distributions of these parameters. For a set of residual survival data from biotin-labeled RBCs, we fit models based on Weibull, gamma, and lognormal distributions, using nonlinear mixed effects modeling and parametric bootstrapping. From the estimated Weibull, gamma, and lognormal parameters we computed the respective population mean full lifespans (95 % confidence interval): 115.60 (109.17-121.66), 116.71 (110.81-122.51), and 116.79 (111.23-122.75) days together with the standard deviations of the full lifespans: 24.77 (20.82-28.81), 24.30 (20.53-28.33), and 24.19 (20.43-27.73). We then estimated the 95th percentiles of the lifespan distributions (a surrogate for the maximum lifespan): 153.95 (150.02-158.36), 159.51 (155.09-164.00), and 160.40 (156.00-165.58) days, the mean current ages (or the mean residual lifespans): 60.45 (58.18-62.85), 60.82 (58.77-63.33), and 57.26 (54.33-60.61) days, and the residual half-lives: 57.97 (54.96-60.90), 58.36 (55.45-61.26), and 58.40 (55.62-61.37) days, for the Weibull, gamma, and lognormal models respectively. Corresponding estimates were obtained for the individual subjects. The three models provide equally excellent goodness-of-fit, reliable estimation, and physiologically plausible values of the directly interpretable RBC survival parameters.


Assuntos
Senescência Celular/fisiologia , Biologia Computacional/métodos , Eritrócitos/fisiologia , Modelos Biológicos , Sobrevivência Celular/fisiologia , Interpretação Estatística de Dados , Humanos
9.
J Pediatr ; 167(5): 1001-6, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26363547

RESUMO

OBJECTIVE: Based on the hypothesis that neonatal autologous red blood cell (RBC) survival (RCS) is substantially shorter than adult RBC, we concurrently tracked the survival of transfused biotin-labeled autologous neonatal and allogeneic adult RBC into ventilated, very low birth weight infants. STUDY DESIGN: RBC aliquots from the first clinically ordered, allogeneic adult RBC transfusion and from autologous infant blood were labeled at separate biotin densities (biotin-labeled RBC [BioRBC]) and transfused. Survival of these BioRBCs populations were concurrently followed over weeks by flow cytometric enumeration using leftover blood. Relative tracking of infant autologous and adult allogeneic BioRBC was analyzed by linear mixed modeling of batched weekly data. When possible, Kidd antigen (Jka and Jkb) mismatches between infant and donor RBCs were also used to track these 2 populations. RESULTS: Contrary to our hypothesis, concurrent tracking curves of RCS of neonatal and adult BioRBC in 15 study infants did not differ until week 7, after which neonatal RCS became shortened to 59%-79% of adult enumeration values for uncertain reasons. Analysis of mismatched Kidd antigen RBC showed similar results, thus, confirming that BioRBC tracking is not perturbed by biotin RBC labeling. CONCLUSIONS: This study illustrates the utility of multidensity BioRBC labeling for concurrent measurement of RCS of multiple RBC populations in vivo. The similar RCS results observed for neonatal and adult BioRBCs transfused into very low birth weight infants provides strong evidence that the circulatory environment of the newborn infant, not intrinsic infant-adult RBC differences, is the primary determinant of erythrocyte survival. TRIAL REGISTRATION: Clinicaltrials.gov: NCT00731588.


Assuntos
Biotina/química , Transfusão de Eritrócitos/métodos , Adulto , Biotinilação , Sobrevivência Celular , Eritropoese , Feminino , Citometria de Fluxo , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Recém-Nascido de muito Baixo Peso , Sistema do Grupo Sanguíneo Kidd , Masculino , Modelos Teóricos , Estudos Prospectivos , Transplante Autólogo , Transplante Homólogo
10.
J Nutr ; 145(1): 32-40, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25527659

RESUMO

BACKGROUND: A large number of birth defects are related to nutrient deficiencies; concern that biotin deficiency is teratogenic in humans is reasonable. Surprisingly, studies indicate that increased urinary 3-hydroxyisovalerylcarnitine (3HIAc), a previously validated marker of biotin deficiency, is not a valid biomarker in pregnancy. OBJECTIVE: In this study we hypothesized that coexisting carnitine deficiency can prevent the increase in 3HIAc due to biotin deficiency. METHODS: We used a 2-factor nutrient depletion design to induce isolated and combined biotin and carnitine deficiency in HepG2 cells and then repleted cells with carnitine. To elucidate the metabolic pathogenesis, we quantitated intracellular and extracellular free carnitine, acylcarnitines, and acylcarnitine ratios using liquid chromatography-tandem mass spectrometry. RESULTS: Relative to biotin-sufficient, carnitine-sufficient cells, intracellular acetylcarnitine increased by 90%, propionylcarnitine more than doubled, and 3HIAc increased by >10-fold in biotin-deficient, carnitine-sufficient (BDCS) cells, consistent with a defensive mechanism in which biotin-deficient cells transesterify the acyl-coenzyme A (acyl-CoA) substrates of the biotin-dependent carboxylases to the related acylcarnitines. Likewise, in BDCS cells, the ratio of acetylcarnitine to malonylcarnitine and the ratio of propionylcarnitine to methylmalonylcarnitine both more than tripled, and the ratio of 3HIAc to 3-methylglutarylcarnitine (MGc) increased by >10-fold. In biotin-deficient, carnitine-deficient (BDCD) cells, the 3 substrate-derived acylcarnitines changed little, but the substrate:product ratios were masked to a lesser extent. Moreover, carnitine repletion unmasked biotin deficiency in BDCD cells as shown by increases in acetylcarnitine, propionylcarnitine, and 3HIAc (each increased by >50-fold). Likewise, ratios of acetylcarnitine:malonylcarnitine, propionylcarnitine:methylmalonylcarnitine, and 3HIAc:MGc all increased by >8-fold. CONCLUSIONS: Our findings provide strong evidence that coexisting carnitine deficiency masks some indicators of biotin deficiency and support the potential importance of the ratios of acylcarnitines arising from the acyl-CoA substrates and products for biotin-dependent carboxylases in detecting the biotin deficiency that is masked by coexisting carnitine deficiency.


Assuntos
Biotina/deficiência , Carnitina/deficiência , Acil Coenzima A/metabolismo , Biomarcadores/urina , Biotina/farmacologia , Biotina/fisiologia , Carnitina/administração & dosagem , Carnitina/análogos & derivados , Carnitina/análise , Carnitina/metabolismo , Carnitina/urina , Cromatografia Líquida , Meios de Cultura/química , Reações Falso-Negativas , Feminino , Células Hep G2 , Humanos , Gravidez , Espectrometria de Massas em Tandem
11.
Pediatr Res ; 74(6): 689-97, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24108188

RESUMO

BACKGROUND: Anemia, a common condition among critically ill premature infants, is affected by red blood cell (RBC) survival (RCS). We hypothesized that transfused allogeneic Kidd antigen-mismatched RBCs would demonstrate the same concurrent RCS tracking as RBCs multilabeled at separate, discrete low densities with biotin (BioRBCs). METHODS: Allogeneic RBCs from adult donors were labeled at four biotin densities, mixed, and transfused into 17 anemic premature infants. Nine of the donors and neonates were Kidd antigen mismatched. Serial posttransfusion blood samples were assayed for up to 8 wk by flow cytometry to track the survival of the proportions of Kidd antigen-mismatched and Kidd antigen-biotinylated RBCs. RESULTS: Using linear mixed modeling to compare results, RCS of the three lowest BioRBC densities was similar to RCS by Kidd antigen mismatch and to one another. RCS of RBCs labeled at the highest BioRBC density was shortened. CONCLUSION: RCS of different populations of RBCs can be tracked concurrently and reliably using the three lowest BioRBC densities. Although comparable RCS results can be achieved using Kidd antigen mismatches, BioRBCs are preferred for investigating neonatal anemia because biotin labeling of both allogeneic and autologous RBCs is possible.


Assuntos
Biotina/metabolismo , Sobrevivência Celular , Transfusão de Eritrócitos , Eritrócitos , Recém-Nascido Prematuro , Sistema do Grupo Sanguíneo Kidd/imunologia , Adulto , Eritrócitos/imunologia , Eritrócitos/metabolismo , Hemoglobina Fetal/metabolismo , Citometria de Fluxo , Humanos , Recém-Nascido
12.
Pediatr Res ; 74(5): 592-600, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24088873

RESUMO

BACKGROUND: Study of the pathophysiology and treatment of anemia of prematurity is facilitated by direct measurement of red cell volume (RCV) utilizing microliter quantities of blood samples. Our objective was to compare concurrent measurements of multiple direct RCV methods in infants. METHODS: Eighteen preterm infants receiving clinically indicated transfusions had concurrent flow cytometric determinations of RCV and 24-h red blood cell (RBC) recovery based on donor-recipient differences of biotin-labeled RBCs (BioRBCs), Kidd antigen mismatched RBCs, and fetal hemoglobin-positive (HbF(+)) RBCs. High-performance liquid chromatography (HPLC) was also used for measuring HbF and adult hemoglobin protein concentrations for the determination of RCV. RESULTS: Concurrent RCV measurements using BioRBCs (18 and 54 µg/ml), Kidd antigen, and HbF flow cytometry were not statistically different compared with RCVs measured using the reference BioRBC density (6 µg/ml). By contrast, the HbF-HPLC method overestimated RCV by 45% compared with the reference method. All the methods demonstrated 100% 24-h posttransfusion RBC recovery (PTR24). CONCLUSION: Because BioRBC, Kidd antigen, and fetal hemoglobin (HbF) flow cytometry are safe and accurate methods requiring <10 µl of patient blood for determining RCV and PTR24 in preterm infants, they can be useful in clinical and research studies of anemia and other conditions.


Assuntos
Anemia/terapia , Volume de Eritrócitos , Citometria de Fluxo/métodos , Recém-Nascido Prematuro/sangue , Recém-Nascido de muito Baixo Peso/sangue , Transfusão de Sangue/métodos , Cromatografia Líquida de Alta Pressão/métodos , Hemoglobina Fetal/metabolismo , Humanos , Recém-Nascido , Sistema do Grupo Sanguíneo Kidd/análise , Análise de Regressão
13.
J Nutr ; 142(9): 1621-5, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22833654

RESUMO

This work describes a novel liquid chromatography tandem MS (LC-MS/MS) method for the determination of ratios of acylcarnitines arising from acyl-CoA substrates and products that reflect metabolic disturbances caused by marginal biotin deficiency. The urinary ratios reflecting reduced activities of biotin-dependent enzymes include the following: 1) the ratio of 3-hydroxyisovalerylcarnitine : 3-methylglutarylcarnitine (3HIAc : MGc) for methylcrotonyl-CoA carboxylase; 2) the ratio of propionylcarnitine:methylmalonylcarnitine (Pc : MMc) for propionyl-CoA carboxylase (PCC); and 3) the ratio of acetylcarnitine : malonylcarnitine (Ac : Mc) for acetyl-CoA carboxylase. To demonstrate the suitability of the LC-MS/MS method for biomonitoring, we measured the 3 ratios for 7 healthy adults at various time points (d 0, 14, and 28) during the induction of marginal biotin through the consumption of egg white. The mean change in the Pc : MMc ratio relative to d 0 was 5.3-fold by d 14 (P = 0.0049) and 8.5-fold by d 28 (P = 0.0042). The mean change in the 3HIAc : MGc ratio was 2.8-fold by d 14 (P = 0.0022) and 3.8-fold by d 28 (P = 0.0001). The mean change in the Ac : Mc ratio was 2.9-fold by d 14 (P = 0.03) and 4.7-fold by d 28 (P = 0.02). The results suggest that simultaneous assessment of ratios of multiple biotin-dependent pathways offers insight into the complex metabolic disturbances caused by marginal biotin deficiency. We hypothesize that one or a combination of the ratios might be more sensitive or robust with respect to other nutrient deficiencies or confounding metabolic processes.


Assuntos
Biotina/deficiência , Carnitina/análogos & derivados , Cromatografia Líquida/métodos , Deficiências Nutricionais/urina , Espectrometria de Massas em Tandem/métodos , Acetil-CoA Carboxilase/metabolismo , Biomarcadores/urina , Biotina/urina , Carbono-Carbono Ligases/metabolismo , Carbono-Nitrogênio Ligases/metabolismo , Carnitina/análise , Carnitina/urina , Cromatografia Líquida/normas , Deficiências Nutricionais/diagnóstico , Glutaratos/análise , Glutaratos/urina , Humanos , Metilmalonil-CoA Descarboxilase/metabolismo , Reprodutibilidade dos Testes , Especificidade por Substrato , Espectrometria de Massas em Tandem/normas
14.
J Nutr ; 142(1): 22-6, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22157538

RESUMO

To date, marginal, asymptomatic biotin deficiency has been successfully induced experimentally by the use of labor-intensive inpatient designs requiring rigorous dietary control. We sought to determine if marginal biotin deficiency could be induced in humans in a less expensive outpatient design incorporating a self-selected, mixed general diet. We sought to examine the efficacy of three outpatient study designs: two based on oral avidin dosing and one based on a diet high in undenatured egg white for a period of 28 d. In study design 1, participants (n = 4; 3 women) received avidin in capsules with a biotin binding capacity of 7 times the estimated dietary biotin intake of a typical self-selected diet. In study design 2, participants (n = 2; 2 women) received double the amount of avidin capsules (14 times the estimated dietary biotin intake). In study design 3, participants (n = 5; 3 women) consumed egg-white beverages containing avidin with a biotin binding capacity of 7 times the estimated dietary biotin intake. Established indices of biotin status [lymphocyte propionyl-CoA carboxylase activity; urinary excretion of 3-hydroxyisovaleric acid, 3-hydroxyisovaleryl carnitine (3HIA-carnitine), and biotin; and plasma concentration of 3HIA-carnitine] indicated that study designs 1 and 2 were not effective in inducing marginal biotin deficiency, but study design 3 was as effective as previous inpatient study designs that induced deficiency by egg-white beverage. Marginal biotin deficiency can be induced experimentally by using a cost-effective outpatient design by avidin delivery in egg-white beverages. This design should be useful to the broader nutritional research community.


Assuntos
Biotina/deficiência , Análise Custo-Benefício , Pacientes Ambulatoriais , Animais , Deficiências Nutricionais/etiologia , Deficiências Nutricionais/urina , Feminino , Humanos , Masculino , Camundongos
15.
Transfusion ; 52(5): 1097-105, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22023312

RESUMO

BACKGROUND: Safe, accurate methods to reliably measure circulating red blood cell (RBC) kinetics are critical tools to investigate pathophysiology and therapy of anemia, including hemolytic anemias. This study documents the ability of a method using biotin-labeled RBCs (BioRBCs) to measure RBC survival (RCS) shortened by coating with a highly purified monomeric immunoglobulin G antibody to D antigen. STUDY DESIGN AND METHODS: Autologous RBCs from 10 healthy D+ subjects were labeled with either biotin or (51) Cr (reference method), coated (opsonized) either lightly (n = 4) or heavily (n = 6) with anti-D, and transfused. RCS was determined for BioRBCs and for (51) Cr independently as assessed by three variables: 1) posttransfusion recovery at 24 hours (PTR(24) ) for short-term RCS; 2) time to 50% decrease of the label (T(50) ), and 3) mean potential life span (MPL) for long-term RCS. RESULTS: BioRBCs tracked both normal and shortened RCS accurately relative to (51) Cr. For lightly coated RBCs, mean PTR(24) , T(50) , and MPL results were not different between BioRBCs and (51) Cr. For heavily coated RBCs, both short-term and long-term RCS were shortened by approximately 17 and 50%, respectively. Mean PTR(24) by BioRBCs (84 ± 18%) was not different from (51) Cr (81 ± 10%); mean T(50) by BioRBCs (23 ± 17 days) was not different from (51) Cr (22 ± 18 days). CONCLUSION: RCS shortened by coating with anti-D can be accurately measured by BioRBCs. We speculate that BioRBCs will be useful for studying RCS in conditions involving accelerated removal of RBCs including allo- and autoimmune hemolytic anemias.


Assuntos
Biotina , Eritrócitos/fisiologia , Isoanticorpos/imunologia , Sobrevivência Celular , Radioisótopos de Cromo , Humanos , Imunoglobulina rho(D)
16.
Transfusion ; 52(5): 963-73, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22229348

RESUMO

BACKGROUND: Measurement of red blood cell (RBC) survival (RCS) is important for investigating pathophysiology and treatment of anemia. Our objective was to validate the multidensity biotin method for RCS determination in sheep, a commonly used model of RBC physiology. [(14) C]Cyanate served as the reference method for long-term RCS because the (51) Cr method (the reference method for humans) is not reliable in sheep. STUDY DESIGN AND METHODS: Aliquots of autologous RBCs from eight adult sheep were labeled with [(14) C]cyanate and four separate densities of biotin (BioRBCs) and reinfused. Short-term RCS was assessed by posttransfusion recovery at 24 hours (PTR(24) ); long-term RCS was assessed by the time to 50% survival (T(50) ) and mean potential life span (MPL). RESULTS: Values for PTR(24) of the four BioRBC densities were not different. Values for RCS as reflected by T(50) and MPL were nearly identical for [(14) C]cyanate and the two intermediate-density BioRBC populations. In contrast, the lowest-density BioRBC population survived slightly longer (p < 0.01), but with a difference of no clinical significance. The highest-density BioRBC population importantly shortened RCS (p < 0.01 compared to the two intermediate densities). CONCLUSION: This study provides evidence that BioRBCs labeled at four biotin densities can be used to independently and simultaneously measure short-term RCS and that BioRBCs labeled at the three lowest biotin densities can be used to accurately and simultaneously measure long-term RCS. Because the sheep RBC model is comparable to humans, this nonradioactive method has promise for use in RBC kinetic studies in neonates and pregnant women.


Assuntos
Biotina/metabolismo , Radioisótopos de Carbono , Cianatos/metabolismo , Eritrócitos/fisiologia , Animais , Formação de Anticorpos , Sobrevivência Celular , Radioisótopos de Cromo , Humanos , Ovinos
17.
Mol Genet Metab ; 102(2): 161-9, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21051254

RESUMO

Biotinidase deficiency is the primary enzymatic defect in biotin-responsive, late-onset multiple carboxylase deficiency. Untreated children with profound biotinidase deficiency usually exhibit neurological symptoms including lethargy, hypotonia, seizures, developmental delay, sensorineural hearing loss and optic atrophy; and cutaneous symptoms including skin rash, conjunctivitis and alopecia. Although the clinical features of the disorder markedly improve or are prevented with biotin supplementation, some symptoms, once they occur, such as developmental delay, hearing loss and optic atrophy, are usually irreversible. To prevent development of symptoms, the disorder is screened for in the newborn period in essentially all states and in many countries. In order to better understand many aspects of the pathophysiology of the disorder, we have developed a transgenic biotinidase-deficient mouse. The mouse has a null mutation that results in no detectable serum biotinidase activity or cross-reacting material to antibody prepared against biotinidase. When fed a biotin-deficient diet these mice develop neurological and cutaneous symptoms, carboxylase deficiency, mild hyperammonemia, and exhibit increased urinary excretion of 3-hydroxyisovaleric acid and biotin and biotin metabolites. The clinical features are reversed with biotin supplementation. This biotinidase-deficient animal can be used to study systematically many aspects of the disorder and the role of biotinidase, biotin and biocytin in normal and in enzyme-deficient states.


Assuntos
Biotina/farmacologia , Deficiência de Biotinidase/genética , Deficiência de Biotinidase/metabolismo , Modelos Animais de Doenças , Síndromes Neurocutâneas/enzimologia , Complexo Vitamínico B/farmacologia , Animais , Comportamento Animal , Biotina/metabolismo , Biotina/uso terapêutico , Biotina/urina , Biotinidase/sangue , Biotinidase/metabolismo , Deficiência de Biotinidase/tratamento farmacológico , Peso Corporal/efeitos dos fármacos , Peso Corporal/genética , Dieta , Feminino , Regulação Enzimológica da Expressão Gênica/genética , Fígado/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Síndromes Neurocutâneas/tratamento farmacológico , Síndromes Neurocutâneas/genética , Complexo Vitamínico B/metabolismo , Complexo Vitamínico B/uso terapêutico , Complexo Vitamínico B/urina
18.
J Nutr ; 141(3): 353-8, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21248194

RESUMO

Mounting evidence indicates that marginal biotin deficiency is not rare, contrary to previous assumptions. Accordingly, robust indicators of biotin status would be useful. In a study of 10 healthy adults, we recently provided evidence that abnormally increased plasma concentration of 3-hydroxyisovaleryl carnitine (3HIA-carnitine) is a sensitive indicator of marginal biotin deficiency. We sought to determine whether urinary excretion of 3HIA-carnitine (expressed as the ratio to urinary creatinine) significantly increases in marginal biotin deficiency. Marginal, asymptomatic biotin deficiency was induced experimentally in the same 10 healthy adults (8 women) by feeding undenatured egg white with meals for 28 d. Biotin status was repleted by a mixed general diet plus biotin supplementation. Urinary excretion of 3HIA-carnitine was determined by liquid chromatography-tandem MS on d 0, 14, and 28 (depletion) and on d 35 and 50 (repletion). Mean urinary 3HIA-carnitine concentration increased with depletion (P < 0.0001; d 0 vs. 28) and decreased with repletion (P = 0.0002; d 28 vs. 50). Urinary 3HIA-carnitine excretion was greater than the upper limit of normal in 9 of 10 participants by d 14 and decreased to within normal limits by d 50 in all participants. This study provides evidence that urinary excretion of 3HIA-carnitine is an early and sensitive indicator of marginal biotin deficiency. The ease of collection of untimed urine samples and application of a new analytical method with simplified sample preparation suggest that urinary 3HIA-carnitine is likely to be a useful indicator for large population studies.


Assuntos
Biotina/deficiência , Carnitina/análogos & derivados , Estado Nutricional , Deficiência de Vitaminas do Complexo B/diagnóstico , Deficiência de Vitaminas do Complexo B/urina , Adulto , Biomarcadores/sangue , Biomarcadores/urina , Biotina/uso terapêutico , Carnitina/urina , Clara de Ovo , Feminino , Humanos , Linfócitos/enzimologia , Masculino , Metilmalonil-CoA Descarboxilase/sangue , Valores de Referência , Fatores de Tempo , Deficiência de Vitaminas do Complexo B/sangue , Deficiência de Vitaminas do Complexo B/tratamento farmacológico
19.
J Nutr ; 141(11): 1925-30, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21918059

RESUMO

Experimentally increasing metabolic flux in a pathway in which an essential step is catalyzed by a vitamin-dependent enzyme (a challenge test) has been used in assessing functional vitamin status and elucidating common and alternate metabolic pathways. Conversion of 3-methylcrotonyl CoA to 3-methylglutaconyl CoA in the leucine catabolic pathway is catalyzed by the biotin-dependent enzyme methylcrotonyl-CoA carboxylase (MCC). Marginal biotin deficiency reduces MCC activity and increases urinary excretion of 3-hydroxyisovaleric acid (3HIA) and 3-hydroxyisovaleryl carnitine (3HIA-carnitine) measured in 24-h urine collections. We assessed urinary excretion of 3HIA and 3HIA-carnitine in response to a leucine challenge in humans made progressively biotin deficient by egg white consumption. In 2 cohorts of healthy adults (Study 1: n = 5; Study 2: n = 7) rendered biotin deficient over 28 d, urinary excretion of 3HIA and 3HIA-carnitine in response to a leucine challenge was quantitated weekly for 3 or 4 wk, respectively. In both studies, mean urinary excretion of both 3HIA and 3HIA-carnitine increased >2-fold by d 14 (P < 0.002 for both indicators for both studies). Diagnostically, both indicators were highly sensitive, but diagnostic sensitivities were not superior to those of 24-h excretion of 3HIA and 3HIA-carnitine. These studies provide evidence that urinary excretions of 3HIA and 3HIA-carnitine in response to an oral leucine challenge are early and sensitive indicators of marginal biotin deficiency in humans. The variability of the proportion of leucine catabolites excreted as 3HIA suggests substantial population heterogeneity in the metabolic capacity of the 3HIA-carnitine detoxification pathway.


Assuntos
Biotina/deficiência , Carnitina/análogos & derivados , Leucina/administração & dosagem , Valeratos/urina , Adulto , Carnitina/urina , Estudos de Coortes , Feminino , Humanos , Masculino
20.
Transfusion ; 51(5): 1047-57, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21062290

RESUMO

BACKGROUND: Safe, accurate methods permitting simultaneous and/or repeated measurement of red blood cell (RBC) survival (RCS) are important to investigate pathophysiology and therapy of anemia. Methods using chromium 51 ((51) Cr)-labeled RBCs are unacceptable for infants, children, and pregnant women. We report RCS measured in vivo using RBCs labeled with several densities of biotin (BioRBCs). STUDY DESIGN AND METHODS: Aliquots of autologous RBCs from eight healthy adult subjects were labeled separately at four discrete biotin densities, mixed, and infused. The proportion of each population of BioRBCs circulating was determined serially by flow cytometry over 20 weeks. For each population, RCS was assessed by the following: 1) posttransfusion BioRBC recovery at 24 hours (PTR(24) ); 2) time to decrease to 50% of the enrichment at 24 hours (T(50) ); and 3) mean potential lifespan (MPL). RESULTS: Among the four BioRBC densities, no significant differences in PTR(24) were observed. T(50) and MPL were similar for the two lowest BioRBC densities. In contrast, the two highest BioRBC densities demonstrated progressively decreased T(50) and MPL. CONCLUSIONS: RBCs labeled at four biotin densities can be used to independently and accurately measure PTR(24 ) and two lowest biotin densities can accurately quantitate long-term RCS. This method provides a tool for investigating anemia in infants, fetuses, and pregnant women with the following advantages over the standard (51) Cr method: 1) study subjects are not exposed to radiation; 2) small blood volumes (e.g., 20 µL) are required; and 3) multiple independent RCS measurements can be made simultaneously in the same individual.


Assuntos
Biotina/metabolismo , Biotinilação/métodos , Transfusão de Eritrócitos/normas , Eritrócitos/citologia , Citometria de Fluxo/métodos , Adulto , Anticorpos/sangue , Biotina/imunologia , Sobrevivência Celular/fisiologia , Eritrócitos/imunologia , Eritrócitos/metabolismo , Feminino , Citometria de Fluxo/normas , Haptoglobinas/metabolismo , Hemólise , Humanos , Masculino , Pessoa de Meia-Idade , Padrões de Referência , Coloração e Rotulagem/métodos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA