Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Cytotherapy ; 19(3): 349-359, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28089079

RESUMO

BACKGROUND AIMS: Cell therapy with mesenchymal stromal cells (MSCs) offers new hope for patients suffering from spinal cord injury (SCI). METHODS: Ten patients with established incomplete SCI received four subarachnoid administrations of 30 × 106 autologous bone marrow MSCs, supported in autologous plasma, at months 1, 4, 7 and 10 of the study, and were followed until the month 12. Urodynamic, neurophysiological and neuroimaging studies were performed at months 6 and 12, and compared with basal studies. RESULTS: Variable improvement was found in the patients of the series. All of them showed some degree of improvement in sensitivity and motor function. Sexual function improved in two of the eight male patients. Neuropathic pain was present in four patients before treatment; it disappeared in two of them and decreased in another. Clear improvement in bladder and bowel control were found in all patients suffering previous dysfunction. Before treatment, seven patients suffered spasms, and two improved. Before cell therapy, nine patients suffered variable degree of spasticity, and 3 of them showed clear decrease at the end of follow-up. At this time, nine patients showed infra-lesional electromyographic recordings suggesting active muscle reinnervation, and eight patients showed improvement in bladder compliance. After three administrations of MSCs, mean values of brain-derived neurotrophic factor, glial-derived neurotrophic factor, ciliary neurotrophic factor, and neurotrophin 3 and 4 showed slight increases compared with basal levels, but without statistically significant difference. CONCLUSIONS: Administration of repeated doses of MSCs by subarachnoid route is a well-tolerated procedure that is able to achieve progressive and significant improvement in the quality of life of patients suffering incomplete SCI.


Assuntos
Transfusão de Sangue Autóloga/métodos , Transplante de Células-Tronco Mesenquimais/métodos , Células-Tronco Mesenquimais/citologia , Qualidade de Vida , Traumatismos da Medula Espinal/terapia , Adulto , Animais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Plasma , Traumatismos da Medula Espinal/patologia , Espaço Subaracnóideo , Transplante Autólogo
2.
J Chem Theory Comput ; 19(6): 1818-1826, 2023 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-36877528

RESUMO

Spectroscopic properties of molecules hold great importance for the description of the molecular response under the effect of UV/vis electromagnetic radiation. Computationally expensive ab initio (e.g., MultiConfigurational SCF, Coupled Cluster) or TDDFT methods are commonly used by the quantum chemistry community to compute these properties. In this work, we propose a (supervised) Machine Learning approach to model the absorption spectra of organic molecules. Several supervised ML methods have been tested such as Kernel Ridge Regression (KRR), Multiperceptron Neural Networs (MLP), and Convolutional Neural Networks. [Ramakrishnan et al. J. Chem. Phys. 2015, 143, 084111. Ghosh et al. Adv. Sci. 2019, 6, 1801367.] The use of only geometrical-atomic number descriptors (e.g., Coulomb Matrix) proved to be insufficient for an accurate training. [Ramakrishnan et al. J. Chem. Phys. 2015, 143, 084111.] Inspired by the TDDFT theory, we propose to use a set of electronic descriptors obtained from low-cost DFT methods: orbital energy differences (Δϵia = ϵa - ϵi), transition dipole moment between occupied and unoccupied Kohn-Sham orbitals (⟨ϕi|r|ϕa⟩), and when relevant, charge-transfer character of monoexcitations (Ria). We demonstrate that with these electronic descriptors and the use of Neural Networks we can predict not only a density of excited states but also get a very good estimation of the absorption spectrum and charge-transfer character of the electronic excited states, reaching results close to chemical accuracy (∼2 kcal/mol or ∼0.1 eV).

3.
Rev. cuba. obstet. ginecol ; 42(4): 570-578, sep.-dic. 2016. ilus
Artigo em Espanhol | LILACS | ID: biblio-845041

RESUMO

Introducción: el corazón fetal es la víscera más difícil de estudiar, debido a que es un órgano móvil con una anatomía compleja y presenta un número importante de anomalías posibles. Objetivos: exponer al alcance de los especialistas dedicados al diagnóstico prenatal una revisión de las posibles causas que modifican el tamaño del corazón fetal. Métodos: la evaluación de su tamaño se realiza a partir de la vista ecocardiográfica de las cuatro cámaras la cual es obtenida realizando un barrido ultrasonográfico desde el abdomen hasta el tórax. Cuando el tamaño es normal, ocupa un tercio del tórax fetal y la circunferencia cardíaca equivale aproximadamente a la mitad de la circunferencia torácica durante todo el curso del embarazo. Resultados: las anomalías del tamaño del corazón pueden ser ocasionadas por disminución o por incremento del radio cardiotorácico. En relación con su incremento es muy importante definir si este es debido a un crecimiento global del corazón o si está afectada una cavidad auricular, ventricular o ambas. En cuanto a la disminución del tamaño este siempre será debido a compresiones intratoráxicas. Conclusiones: la evaluación ecocardiográfica del corazón fetal resulta posible en casi la totalidad de los casos y aporta un elemento de valor al examen prenatal del feto(AU)


Introduction: Fetus heart is the most difficult viscera to be studied, due to the fact that it is a moving organ with a complex anatomy and an important amount of possible anomalies. Objective: To provide the specialists devoted to the prenatal diagnose with a review of the possible causes that modify the fetus heart size. Methods: The heart size is evaluated from an echocardiographic image of its four chambers, which is obtained in an ultrasonic scanning¨from the abdomen to the thorax. When the size is normal, it occupies one third of the fetal thorax and the cardiac circumference is roughly equal to half the thorax circumference throughout the pregnancy. Results: Heart size anomalies could be caused by a drop or an increase of the cardiothoracic radius. It is very important to define whether the increase is due to a global growth of the heart or to an affected atrial or ventricular cavity, or both. Size decreases will always be connected to an intrathoracic compression. Conclusions: Echocardiographic assessment of the fetal heart is possible in almost all cases and provides a valuable element to the fetus prenatal testing(AU)


Assuntos
Humanos , Feminino , Gravidez , Coração Fetal/anormalidades , Coração Fetal/crescimento & desenvolvimento , Diagnóstico Pré-Natal/métodos , Coração Fetal/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Tamanho do Órgão
4.
Rev. argent. cardiol ; 80(3): 253-256, jun. 2012. ilus
Artigo em Espanhol | LILACS | ID: lil-657568

RESUMO

El diagnóstico de anillo vascular con arco aórtico derecho en el feto favorece un tratamiento precoz después del nacimiento, que permite evitar la morbilidad tanto en la infancia como en edades mayores. En esta presentación se describen los hallazgos sonográficos en dos casos de arco aórtico derecho asociado con arteria subclavia izquierda aberrante y ductus arterioso izquierdo. Se realizó un estudio ecocardiográfico detallado del corazón fetal, con particular énfasis en la vista extendida de los tres vasos, en dos gestantes con 24 semanas de embarazo y edades de 18 y 24 años, atendidas en el Cardiocentro Pediátrico "William Soler"; se utilizó un equipo ATL (HDI 5000), de fabricación estadounidense, con transductor de 3 MHz. En ambos fetos se detectó la presencia de arco aórtico derecho, ductus arterioso izquierdo y arteria subclavia izquierda aberrante. Al utilizar el Doppler color se apreció una zona dilatada, conocida como divertículo de Kommerell. Uno de los fetos presentaba además tetralogía de Fallot asociada; en este caso, la gestante optó por la interrupción del embarazo. Ambos diagnósticos prenatales fueron confirmados, uno mediante ecocardiografía posnatal y el otro a través del estudio anatomopatológico. La presencia de un arco aórtico derecho, ductus arterioso izquierdo y arteria subclavia izquierda aberrante constituye una variante poco frecuente, con posibilidades de diagnóstico prenatal.


The diagnosis of vascular ring with right aortic arch allows early treatment after birth preventing morbidity in infants and older children. We describe the sonographic findings of two patients with right-sided aortic arch associated with aberrant left subclavian artery and left ductus arteriosus. Two women at 24 weeks pregnant aged 18 and 24 years old underwent a thorough echocardiographic evaluation of the fetal heart by targeted visualization of the three-vessel view at the Cardiocentro Pediátrico "William Soler", using an ATL HDI 5000 ultrasound machine made in USA with a 3 MHz transducer. The presence of a right-sided aortic arch, left ductus arteriosus and aberrant left subclavian artery was detected in both cases. Color Doppler ultrasound demonstrated the presence of Kommerell's diverticulum. One of the fetus also presented Tetralogy of Fallot and the woman opted for abortion. Both prenatal diagnoses were confirmed, one by postnatal echocardiography and the other by histopathological study. The presence of right-sided aortic arch, left ductus arteriosus and aberrant left subclavian artery is an uncommon anomaly that can be detected by prenatal ultrasound.

5.
Rev. cuba. pediatr ; 84(3): 301-306, jul.-set. 2012.
Artigo em Espanhol | LILACS | ID: lil-650778

RESUMO

La estenosis pulmonar valvular crítica es una cardiopatía congénita relativamente frecuente en el recién nacido, cuya supervivencia depende de una intervención inmediata, ya sea farmacológica o quirúrgica. Su diagnóstico prenatal ha permitido tratarla in útero mediante dilatación de la válvula por angioplastia con balón. Esta técnica conlleva los riesgos inherentes a todo proceder que implique el acceso al feto. Está demostrado que con la angioplastia posnatal precozmente diagnosticada mediante ecocardiografía, se pueden obtener resultados igualmente satisfactorios, previa estabilización clínica y hemodinámica del paciente. Apostamos, pues, por esta última.


Critical valvular pulmonary stenosis is a relatively frequent congenital cardiopathy in the newborn, whose survival depends on an immediate intervention either pharmacological or surgical. The prenatal diagnosis allows the intrauterine treatment by dilating the valve through the ball angioplasty. This technique carries the risks inherent to any procedures involving access to the fetus. It has been proved that postnatal angioplasty, early diagnosed with echography, can obtain the same satisfactory results, after the clinical and hemodynamic stabilization of the patient. Therefore, we support postnatal angioplasty.

6.
Rev. cuba. obstet. ginecol ; 37(4): 593-598, oct.-dic. 2011.
Artigo em Espanhol | LILACS | ID: lil-615242

RESUMO

Se reporta el caso de una gestante que en ultrasonido realizado en el segundo trimestre de la gestación se sospecha un defecto de septación ventricular, se confirmó la presencia de una comunicación interventricular tipo perimembranosa con extensión muscular y mal alineamiento del tabique interventricular, que trajo como consecuencia disminución del tamaño del tracto de salida del ventrículo izquierdo, sin causar obstrucción. En el estudio posnatal se evidenció la patología señalada así como la presencia de una comunicación interauricular y persistencia del conducto arterioso. Las ilustraciones empleadas se corresponden con imágenes grabadas en el Cardiocentro Pediátrico William Soler y en su servicio de anatomía patológica. Se trata del primer caso reportado en nuestro país


The case of a pregnant with suspicion of a ventricular septate defect according to ultrasound carried out during the second trimester of pregnancy is reported confirming the presence of a peri-membranous intraventricular communication with muscular lengthening and a malalignment of interventricular septum leading to a decrease in the size of outlet tract from the left ventricle without obstruction. In the postnatal study it was evidenced the marked pathology, as well as the presence of a interauricular communication and persistence of arterial conduct. Illustrations used are in correspondence with the images taped in the William Soler Children Heart Center and in its pathological anatomy service


Assuntos
Humanos , Comunicação Interventricular/complicações , Comunicação Interventricular , Doenças Fetais/patologia
7.
Rev. cuba. pediatr ; 81(4): 1-9, sep.-dic. 2009.
Artigo em Espanhol | LILACS | ID: lil-629653

RESUMO

INTRODUCCIÓN. Se describen las características ecocardiográficas de los tumores cardíacos primarios en el feto y la evolución y complicaciones de éstos, con el propósito de analizar su comportamiento en dos períodos diferentes a lo largo de 20 años. MÉTODOS. El estudio se desarrolló en dos etapas. En la primera se estudiaron 1,884 embarazadas entre las 18 y 22 semanas de gestación, que acudieron a la consulta por distintos factores de riesgo obstétrico. La técnica utilizada fue la misma empleada internacionalmente, con equipos Combison 320-5 y Aloka 860 con transductores electrónicos de 3,5 y 5 MHz, y Doppler codificado en color, para el estudio de los flujos intracavitarios y los gradientes de presión. RESULTADOS. Se identificaron 6 tumores cardíacos, lo que representó el 0,3 por ciento de los casos examinados. Cinco correspondieron a rabdomiomas, y uno, a un mixoma de la aurícula derecha. La mayoría obstruía los tractos de entrada o salida. Se observó arritmia en un caso. La sensibilidad y especificidad fueron del 100 por ciento y 99,8 por ciento, respectivamente. CONCLUSIONES. Se demuestra la poca frecuencia de los tumores cardíacos en el feto y la importancia de la ecocardiografía por su alta sensibilidad y especificidad


INTRODUCTION: Echocardiographic features of fetal primary heart tumors are described, as well as its natural history and its complications to analyze its behavior during two different periods along 20 years. METHODS: Study was developed in two stages. In the first one a total of 1,884 pregnants between 18 and 22 gestational weeks were studied who were seen in consultation due to different obstetric risk factors. The technique applied was similar to that at worldwide using a equipment Combison 320-5 and Aloka 860 and electronic transducers of 3,5 and 5 MHz, and color coded Doppler to study the intracavitary flux and the pressure gradient. RESULTS: Six cardiac tumors were identified representing the 0,3 percent of study cases. Five were rhabdomyosarcomas, and one was a right atrium myxoma. Most blockade the inlet and outlet tracts. There was an arrhythmia in a case. Sensibility and specificity rates were of 100 percent and 99,8 percent, respectively. CONCLUSIONS: It was shown the poor frequency of fetal cardiac tumors and the significance of echocardiography by its high sensibility and specificity rate


Assuntos
Humanos , Feminino , Gravidez , Diagnóstico Pré-Natal/métodos , Mixoma , Neoplasias Cardíacas , Rabdomioma , Epidemiologia Descritiva , Estudos Observacionais como Assunto , Estudos Retrospectivos
8.
Rev. cuba. pediatr ; 78(2)abr.-jun. 2006. ilus, graf
Artigo em Espanhol | LILACS | ID: lil-465291

RESUMO

Se realiza un análisis retrospectivo de 36 pacientes con cierre de comunicación interauricular, con el objetivo de evaluar la utilidad de la ecocardiografía transesofágica durante este proceder. Se describen las vistas ecocardiográficas utilizadas, así como se determina mediante ecuaciones de regresión la relación entre las dimensiones de la comunicación interauricular por ecocardiografía transtorácica, ecocardiografía transesofágica y después del balón distendido. Se concluye que las vistas de ecocardiografía transesofágica utilizadas en nuestro trabajo permiten el cierre satisfactorio de la comunicación interauricular mediante dispositivo Amplatzer y que la dimensión de la comunicación interauricular después del balón distendido puede ser estimada a partir de las ecocardiografías transesofágica y transtorácica


Assuntos
Ecocardiografia Transesofagiana/métodos , Comunicação Interatrial
9.
Rev. cuba. cardiol. cir. cardiovasc ; 7(2): 110-20, jul.-dic. 1993. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-149793

RESUMO

Se analizan los resultados obtenidos entre octubre de 1986 y septiembre de 1992, en relación con el diagnóstico y tratamiento de de 49 niños operados por presentar drenaje anómalo total de venas pulmonares (DATVP). Elpromedio de edad fue de 6 meses. Hubo 23 casos del tipo supracardíco (46,9 por ciento ), 17del cardíaco (34,7 por ciento ), 5 mixtos (10,2 por ciento ) y 4 infracardíacos (8,2 por ciento ). La mayor edad mediana al operarse fue la del tipo cardíaco (8 meses) y la menor edad la del infracardíaco (o meses) (p<0,01), al igual que la saturación capilar preoperatoria(p<0,0001) y el índice cardiotorácico del telecardiograma (p<0,001) respectivamente. Por el contrario. la presión arterial pulmonar que estuvo moderadamente elevada (49/18 [30] mmHg), fue mayor en el tipo infracardíaco que en los otros 3 tipos (p<0,05) donde el promedio era similar en ellos. Hubo 12 fallecidos para una mortalidad hospitalaria de 24,4 por ciento ésta fue mayor en el tipo infracardíaco (100 por ciento ), seguido del mixto (60 por ciento ), el supracardíaco


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Lactente , Pré-Escolar , Adolescente , Pneumopatia Veno-Oclusiva/cirurgia , Pneumopatia Veno-Oclusiva/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA