Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 139
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38845191

RESUMO

INTRODUCTION: Transvenous lead extractions (TLEs) for cardiac implantable electronic device complications often encounter difficulties with strong adhesions to the myocardium or vessels. In this report, we introduce a novel "Four-Stage Rocket" technique for effective TLE in cases where conventional methods fail. METHODS AND RESULTS: Two challenging cases where conventional TLE methods failed were treated using a combination of four devices: Needle's Eye Snare, Agilis NxT Steerable Introducer, GlideLight Laser sheath, and GORE® DrySeal Flex Introducer sheath, employed via the inferior vena cava. The "Four-Stage Rocket" technique successfully detached firmly adhered leads near the tricuspid valve annulus, where the traditional superior vena cava approach was inadequate. CONCLUSION: The "Four-Stage Rocket" technique offers a potential alternative in complex TLE cases, aligning the laser direction with the adhesion detachment and reducing the tissue damage risk.

2.
Gastrointest Endosc ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38964479

RESUMO

BACKGROUND AND AIMS: There is a high incidence of stricture after endoscopic submucosal dissection (ESD) for cervical esophageal cancer. We aimed to elucidate the risk factors for stricture and evaluate the efficacy of steroid injection for stricture prevention in the cervical esophagus. METHODS: We retrospectively analyzed 100 patients who underwent ESD for cervical esophageal cancer to: (1) identify the factors associated with stricture among patients who did not receive steroid injection; (2) compare the incidence of stricture between patients with and without steroid injection. RESULTS: Among 48 patients who did not receive steroid injection, there were significant differences in tumor size (P = .026), resection time (P = .028), and circumferential extent of the mucosal defect (P = .005) between patients with stricture (n = 5) and without stricture (n = 43). Compared with patients without steroid injection, patients with steroid injection had a significantly lower incidence of stricture when the post-ESD mucosal defect was < 3/4 and ≥ 1/2 (40% versus 8%, P = .039). As for the patients with a post-ESD mucosal defect of ≥ 3/4 (n = 13), local steroid injection was performed for all the patients, and 6 patients (46%) developed stricture. CONCLUSIONS: Patients who underwent ≥ 1/2 circumferential resection were at high risk of cervical esophageal stricture. Steroid injection had a stricture-prevention effect in patients with < 3/4 and ≥ 1/2 circumferential resection, but seemed to be insufficient in preventing stricture in patients with ≥ 3/4 circumferential resection.

3.
Plant Cell Physiol ; 64(10): 1167-1177, 2023 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-37498972

RESUMO

Plant seedlings adjust the growth of the hypocotyl in response to surrounding environmental changes. Genetic studies have revealed key players and pathways in hypocotyl growth, such as phytohormones and light signaling. However, because of genetic redundancy in the genome, it is expected that not-yet-revealed mechanisms can be elucidated through approaches different from genetic ones. Here, we identified a small compound, HYGIC (HG), that simultaneously induces hypocotyl elongation and thickening, accompanied by increased nuclear size and enlargement of cortex cells. HG-induced hypocotyl growth required the ethylene signaling pathway activated by endogenous ethylene, involving CONSTITUTIVE PHOTOMORPHOGENIC 1, ETHYLENE INSENSITIVE 2 (EIN2) and redundant transcription factors for ethylene responses, ETHYLENE INSENSITIVE 3 (EIN3) and EIN3 LIKE 1. By using EBS:GUS, a transcriptional reporter of ethylene responses based on an EIN3-binding-cis-element, we found that HG treatment ectopically activates ethylene responses at the epidermis and cortex of the hypocotyl. RNA-seq and subsequent gene ontology analysis revealed that a significant number of HG-induced genes are related to responses to hypoxia. Indeed, submergence, a representative environment where the hypoxia response is induced in nature, promoted ethylene-signaling-dependent hypocotyl elongation and thickening accompanied by ethylene responses at the epidermis and cortex, which resembled the HG treatment. Collectively, the identification and analysis of HG revealed that ectopic responsiveness to ethylene promotes hypocotyl growth, and this mechanism is activated under submergence.


Assuntos
Proteínas de Arabidopsis , Arabidopsis , Hipocótilo/metabolismo , Proteínas de Ligação a DNA/metabolismo , Proteínas de Arabidopsis/genética , Proteínas de Arabidopsis/metabolismo , Arabidopsis/metabolismo , Transdução de Sinais/fisiologia , Etilenos/farmacologia , Etilenos/metabolismo , Hipóxia , Regulação da Expressão Gênica de Plantas
4.
New Phytol ; 239(3): 936-948, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37270736

RESUMO

Soybeans (Glycine max) develop newly differentiated aerenchymatous phellem (AP) in response to waterlogging stress. AP is formed in the hypocotyl and root, thus contributing to internal aeration and adaptation to waterlogging for several legumes. Extensive accumulation of triterpenoids - lupeol and betulinic acid - has been identified in AP. However, their physiological roles in plants remain unclarified. Lupeol is converted from 2,3-oxidosqualene by lupeol synthase (LUS) and oxidized to betulinic acid. Notably, soybeans have two LUS genes (GmLUS1 and GmLUS2). Functional analysis was performed to reveal the biological and physiological functions of triterpenoids in AP using lus mutants. The AP cells of lus1 mutant lacked triterpenoid accumulation and epicuticular wax. Lupeol and betulinic acid were the major components of epicuticular wax and contributed to tissue hydrophobicity and oxygen transport to the roots. Tissue porosity in AP was lower in the lus1 mutant than in the wild-type, which resulted in reduced oxygen transport to the roots via AP. This reduction in oxygen transport resulted in shallow root systems under waterlogged conditions. Triterpenoid accumulation in AP contributes to effective internal aeration and root development for adaptation to waterlogging, suggesting the significance of triterpenoids in improving waterlogging tolerance.


Assuntos
Glycine max , Triterpenos , Glycine max/genética , Raízes de Plantas , Triterpenos/farmacologia , Oxigênio
5.
J Cardiovasc Electrophysiol ; 34(9): 2002-2005, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37526239

RESUMO

BACKGROUND: A 70-year-old man revealed a rare type of atrioventricular nodal re-entrant tachycardia (AVNRT) involving distinct retrograde pathways, superior slow pathway, and inferolateral left atrial slow pathway. RESULT: Radiofrequency ablation was successfully performed on the noncoronary cusp and in the left atrium, respectively, to eliminate the tachycardias. DISCUSSION AND CONCLUSION: Due to the anomalous electrical conduction patterns, careful diagnosis and ablation strategies were necessary to avoid the risk of atrioventricular block. These findings underscore the diversity and complexity of AVNRT and highlight the importance of tailored therapeutic approaches.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Masculino , Humanos , Idoso , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Fibrilação Atrial/cirurgia , Eletrocardiografia , Fascículo Atrioventricular , Átrios do Coração
6.
J Cardiovasc Electrophysiol ; 34(1): 71-81, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378816

RESUMO

INTRODUCTION: Local impedance (LI) parameters of IntellaNav STABLEPOINT for successful pulmonary vein isolation (PVI) of atrial fibrillation (AF) remain unclear. The purpose of this study was to seek LI data achieving successful PVI. METHODS: Consecutive AF patients who underwent catheter ablation with STABLEPOINT were prospectively enrolled in two centers. PVI was performed under a constant 35-or 40-watt power, 20-s duration, and >5-g contact force. The operators were blinded to the LI data. The characteristics of all ablation points with/without conduction gaps (Unsuccess or Success tags) after the first-attempt PVI were evaluated for the right/left PVs and anterior/posterior wall (RPV/LPV and AW/PW, respectively), and cutoff values of LI data were calculated for successful lesion formation. RESULTS: A total of 5257 ablation points in 102 patients (65 [58-72] years old, 65.7% male) were evaluated. The LI drop values were higher in the Success tags than Unsuccess tags on the LPV-AW and RPV-AW/PW (p < .001), except for the LPV-PW (p = .105). The %LI drop values (LI drop/initial LI) were higher for the Success tags in all areas (15.8 [12.2%-19.6%] vs. 11.6 [9.7%-15.6%] in LPV-AW: p < .001, 15.0 [11.5%-19.3%] vs. 11.4 [8.7%-17.3%] in LPV-PW: p = .035, 15.3 [11.5%-19.4%] vs. 9.9 [8.1%-13.7%] in RPV-AW: p < .001, and 13.3 [10.1%-17.4%] vs. 8.1 [6.3%-9.5%] in RPV-PW, p < .001). The LI drop and %LI drop cutoff values were 20.0 ohms and 11.6%, respectively. CONCLUSIONS: An insufficient LI drop with STABLEPOINT was associated with a gap formation during PVI, and the best cutoff values for the LI drop and %LI drop were 20.0 ohms and 11.6%, respectively.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Impedância Elétrica , Resultado do Tratamento , Frequência Cardíaca , Ablação por Cateter/efeitos adversos , Recidiva
7.
Artigo em Inglês | MEDLINE | ID: mdl-37561371

RESUMO

The subclavian vein is typically used in cardiovascular implantable electronic device (CIED) implantations. External stress on the subclavian vein can lead to lead-related complications. There are several causes of this stress, such as frequent upper extremity movements or external injury. Venous thoracic outlet syndrome (TOS) can also become the cause of external lead stress. However, the diagnosis of venous TOS can be challenging because subclavian venography can appear normal at first glance. We present a unique case of a device infection in a patient with venous TOS. A careful observation of the imaging studies is vital for diagnosing venous TOS and a leadless pacemaker implantation could be an alternative therapeutic option.

8.
Heart Vessels ; 38(2): 216-227, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36173447

RESUMO

Sub-optimal atrioventricular delay (AVD) is one of the main causes of non-responder for cardiac resynchronization therapy (CRT). Recently, device-based algorithms (DBAs) that provide optimal AVD based on intracardiac electrograms, have been developed. However, their long-term effectiveness is still unknown. This study aims to investigate the effect of optimizing AVD using DBAs over a long period, on the prognosis of patients undergoing CRT. A total of 118 patients who underwent CRT at our hospital between April 2008 and March 2018, were retrospectively reviewed; 61 of them with optimizing AVD using DBAs were classified into the treated group (group 1), and the remaining 57 were classified into the control group (group 2). The median follow-up period was 46.0 months. The responder and survival rate in group 1 were significantly better than those in group 2 (group 1 vs. group 2: responder rate = 64% vs. 46%, p = 0.046; survival rate: 85.2% vs. 64.9%, p = 0.02). Moreover, investigating only the non-responder population showed that group 1 had an improved survival rate compared to group 2 (group 1 vs. group 2 = 72.7% vs. 45.1%, p = 0.02). Optimizing AVD using DBAs was a significant contributor to the improved survival rate in CRT non-responders in multivariate analysis (HR 3.6, p = 0.01). In conclusion, the long-term optimizing AVD using DBAs improved the survival rate in CRT and the prognosis of CRT non-responders, as well.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Estudos Retrospectivos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Prognóstico , Algoritmos , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 33(3): 380-388, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35018687

RESUMO

BACKGROUND: Local impedance (LI) can indirectly measure catheter contact and tissue temperature during radiofrequency catheter ablation (RFCA). However, data on the effects of catheter contact angle on LI parameters are scarce. This study aimed to evaluate the influence of catheter contact angle on LI changes and lesion size with two different LI-sensing catheters in a porcine experimental study. METHODS: Lesions were created by the INTELLANAV MiFi™ OI (MiFi) and the INTELLANAV STABLEPOINT™ (STABLEPOINT). RFCA was performed with 30 W and a duration of 30 s. The contact force (CF) (0, 5, 10, 20, and 30 g) and catheter contact angle (30°, 45°, and 90°) were changed in each set (n = 8 each). The LI rise, LI drop, and lesion size were evaluated. RESULTS: The LI rise increased as CF increased. There was no angular dependence with the LI rise under all CFs in the MiFi. On the other hand, the LI rise at 90° was lower than at 30° under 5 and 10 g of CF in STABLEPOINT. The LI drop increased as CF increased. Regarding the difference in catheter contact angles, the LI drop at 90° was lower than that at 30° for both catheters. The maximum lesion widths and surface widths were smaller at 90° than at 30°, whereas there were no differences in lesion depths. CONCLUSION: The LI drop and lesion widths at 90° were significantly smaller than those at 30°, although the lesion depths were not different among the 3 angles for the MiFi and STABLEPOINT.


Assuntos
Ablação por Cateter , Animais , Ablação por Cateter/efeitos adversos , Catéteres , Impedância Elétrica , Desenho de Equipamento , Suínos
10.
J Cardiovasc Electrophysiol ; 33(6): 1336-1340, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35347781

RESUMO

INTRODUCTION: Whether diagnostic computed tomography (CT) scans to cardiac implantable electronic devices (CIED) is safe in recent models remains unknown. METHODS: A two-centers observational study. Over 14 years, consecutive 2362 chest CT scans (1666 pacemakers [PMs], 145 cardiac resynchronization therapy PM, 316 implantable cardioverter-defibrillator, and 233 cardiac resynchronization therapy defibrillator) were interrogated and monitored upon imaging. RESULTS: Electromagnetic interference occurred only in a few old models: InSync 8040 (n = 14), InSync III Marquis (n = 1), and Kappa (n = 4), which resulted no adverse events. CONCLUSION: CIEDs, especially recent ones, are confirmed safe on chest CT.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Marca-Passo Artificial , Computadores , Desfibriladores Implantáveis/efeitos adversos , Humanos , Marca-Passo Artificial/efeitos adversos , Tomografia
11.
J Exp Bot ; 73(19): 6773-6783, 2022 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-35863309

RESUMO

Ripening of climacteric fruits is initiated when the gaseous plant hormone ethylene is perceived by the cell. Ethylene binding to membrane-associated ethylene receptors (ETRs) triggers a series of biochemical events through multiple components, resulting in the induction of numerous ripening-related genes. In tomato (Solanum lycopersicum L.), there are seven members of the ETR family, which each contribute to the regulation of fruit ripening. However, the relative contribution of each individual receptor to ethylene signaling remains unknown. Here, we demonstrated the formation of heteromeric receptor complexes across the two ETR subfamilies in tomato fruit. Immunoprecipitation of subfamily II SlETR4 resulted in co-purification of subfamily I (SlETR1, SlETR2, and SlETR3), but not subfamily II members (SlETR5, SlETR6, and SlETR7). Such biased interactions were verified in yeast two-hybrid assays, and in transgenic Arabidopsis plants, in which heterologous SlETR4 interacts with subfamily I ETRs. Our analysis also revealed that the receptor complexes engage the Raf-like protein kinases SlCTR1 and SlCTR3, which are potential regulators of signaling. Here, we suggest that tomato receptor members form heteromeric complexes to fine-tune signal output to the downstream pathway, which is similar to that of the Arabidopsis system but appears to be partially diverged.


Assuntos
Arabidopsis , Solanum lycopersicum , Solanum lycopersicum/fisiologia , Frutas/metabolismo , Arabidopsis/genética , Regulação da Expressão Gênica de Plantas , Proteínas de Plantas/metabolismo , Etilenos/metabolismo , Plantas Geneticamente Modificadas/metabolismo
12.
Pacing Clin Electrophysiol ; 45(12): 1390-1400, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36222300

RESUMO

BACKGROUND: A novel irrigation catheter (QDOT MICRO™) has been introduced, which enables a surface temperature-controlled ablation combined with tip cooling. However, the detailed description of its complex behavior and effect on the incidence of pops and lesion formation remains elusive. This study aimed to systematically investigate the ablation characteristics, feedback behavior, and incidence of steam pops in a simplified ex vivo swine model. METHODS: Using swine ventricular tissue perfused with saline at 37°C, we systematically created lesions with 4×3 combinations of the wattage (20, 30, 40, and 50 W) and contact force (CF, 10, 30, and 50 g). Ablation was continued for either 120 s or until a steam pop occurred and repeated 10 times with each setting. The lesion geometry, ablation index, feedback dynamics, and conditions underlying the steam pops were measured and analyzed. RESULTS: Steam pops occurred particularly frequently in combinations of a low CF and high power (10 g vs. 30 g+50 g [p < .0001]; 40 W+50 W vs. 20 W+30 W [p < .0001]). Failure to activate a feedback process was associated with a 5.1 times higher incidence of steam pops (21/109 vs.11/11, [95% CI 3.499-7.716], p < .0001). The wattage feedback was particularly evident with a high CF (30 and 50 g) and high initial wattage (40 and 50 W). The average delivered wattage at 27 W predicted the occurrence of steam pops. CONCLUSION: The temperature-controlled ablation with the QDOT MICRO™ demonstrated a complex feedback behavior, which contributed to a reduced incidence of steam pops and prolonged lead time to the pops.


Assuntos
Modelos Teóricos , Vapor , Animais , Suínos
13.
Int Heart J ; 63(5): 953-956, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36184554

RESUMO

The Senning operation used to be widely performed for an intracardiac repair in a complete transposition of the great arteries. During the long-term follow-up, supraventricular tachycardia (SVT) is often observed because of the complex suture lines. The typical mechanism of a Senning-related SVT is cavo-tricuspid isthmus-dependent atrial flutter. On rare occasions, complex SVTs (e.g., biatrial tachycardia (BiAT)) whose diagnosis and treatment are challenging, may occur. We report a rare case of a BiAT following a Senning operation that was successfully ablated from the superior vena cava, and the local activation time histogram module (CARTO3 V7 module [Biosense Webster, Irvine, CA, USA]) was crucial for analyzing the complex circuit.


Assuntos
Transposição das Grandes Artérias , Ablação por Cateter , Situs Inversus , Taquicardia Supraventricular , Transposição dos Grandes Vasos , Transposição das Grandes Artérias/efeitos adversos , Artérias , Ablação por Cateter/efeitos adversos , Humanos , Situs Inversus/complicações , Taquicardia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/cirurgia , Transposição dos Grandes Vasos/complicações , Transposição dos Grandes Vasos/cirurgia , Veia Cava Superior/cirurgia
14.
J Cardiovasc Electrophysiol ; 32(12): 3187-3194, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34559441

RESUMO

BACKGROUND: Local impedance (LI) has emerged as a new technology that informs on electrical catheter-tissue coupling during radiofrequency (RF) ablation. Recently, IntellaNav StablePoint, a novel LI-enabled catheter that equips contact force (CF) sensing, has been introduced. Although StablePoint and its predecessor IntellaNav MiFi OI share the common technology that reports LI, distinct mechanics for LI sensing between the two products raise a concern that the LI-RF lesion formation relationship may differ. METHODS: In an ex vivo swine cardiac tissue model, we investigated the initial level and range of a reduction in LI during a 60-s RF ablation and the resultant lesion characteristics at nine combinations of three energy power (30, 40, and 50 W) and CF (10, 30, and 50 g) steps. Correlations and interactions between CF, LI, wattage, and formed lesions were analyzed. Incidence of achieving LI drop plateau and that of a steam pop were also determined. RESULTS: Positive correlations existed between CF and initial LI, CF and absolute/relative LI drop, CF and lesion volume, and LI drop and lesion volume. At the same LI drop, wattage-dependent gain in lesion volume was observed. Steam pops occurred in all CF steps and the prevalence was highest at 50 W. LI drop predicted a steam pop with a cutoff value at 89Ω. CONCLUSION: In StablePoint, wattage crucially affects LI drop and lesion volume. Because 30 W ablation may by underpowered for intramural lesion formation and 50 W often resulted in a steam pop, 40 W appears to achieve the balance between the safety and efficacy.


Assuntos
Ablação por Cateter , Animais , Ablação por Cateter/métodos , Catéteres , Impedância Elétrica , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Ventrículos do Coração/cirurgia , Vapor , Suínos
15.
J Cardiovasc Electrophysiol ; 32(8): 2069-2076, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34185348

RESUMO

BACKGROUND: The local impedance (LI) reflects the electrical catheter-tissue coupling and correlates with the local tissue temperature. However, there have been few clinical studies showing the recommended method for LI monitoring catheters. This study aimed to investigate the optimal ablation setting for this catheter in an in vitro experimental model. METHODS: LI monitoring catheters were used in an excised swine heart experimental model. The tissue contact force (CF) was directly monitored from an external weight scale. Radiofrequency ablation was performed with a combination of various energy power settings (30, 40, and 50 W), and various CFs (10, 30, and 50 g) for 60 s. The correlation between the LI-related indexes, power, and CF with the lesion formation was statistically analyzed. RESULTS: A positive correlation between the LI or lesion formation and CF was observed under all powers. Although the LI drop always correlated with the maximum lesion depth, lesion diameter, and lesion volume, the coefficient of the correlation value was lower under a high CF (lesion depth, diameter, and volume; 10 g, r = 0.8064, r = 0.8389, r = 0.8477; 30 g, r = 0.7590, r = 0.8063, r = 0.8060; 50 g r = 0.5555, r = 0.5701, and r = 0.5678, respectively). Steam pops occurred only under a 50 W ablation and the LI drop cutoff value for steam pops was 46 Ω. CONCLUSION: The same LI drop did not always lead to the same lesion size when the CF differed. Monitoring the LI and not exceeding 46 Ω would be useful for a safe ablation.


Assuntos
Ablação por Cateter , Animais , Catéteres , Impedância Elétrica , Modelos Teóricos , Vapor , Suínos
16.
J Cardiovasc Electrophysiol ; 32(7): 1877-1883, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33955099

RESUMO

INTRODUCTION: Detailed three-dimensional (3D) mapping has been useful for effective radiofrequency catheter ablation. The Rhythmia system can create atrio-ventricular dual-chamber mapping, which reveals the atrial and ventricular potentials all at once in the same map. The aim of this study was to investigate the utility of mapping the atrium and ventricle simultaneously with a high-density 3D mapping system for the ablation of accessory pathways (AP). METHODS: From July 2015 to August 2020, 111 patients underwent ablation of APs. Dual-chamber maps were created in 50 patients (median age 15 [10-54], 32 male [64.0%]), while 61 patients underwent radiofrequency (RF) ablation with conventional single-chamber 3D maps. The background characteristics and procedural details were compared between the dual-chamber mapping group and the conventional single-chamber mapping group. RESULTS: The number of RF applications (median [IQR]; 1.0 [1.0-3.0] vs. 3.0 [1.0-6.0], p = .0023), RF time (median [IQR], s; 9.2 [2.0-95.7] vs. 95.6 [4.1-248.7], p = .0107), and RF energy (median [IQR], J; 248.4 [58.7-3328.2] vs. 2867.6 [134.2-7728.4], p = .0115) were significantly lower in the dual-chamber group. The fluoroscopy time (median [IQR], min; 19.9 [14.2-26.1] vs. 26.5 [17.7-43.4], p = .0025) and fluoroscopy dose (median [IQR], mGy; 52.5 [31.3-146.0] vs. 119.0 [43.7-213.5], p = .0249) were also significantly lower in the dual-chamber than single-chamber mapping group. CONCLUSION: The dual-chamber mapping was useful for ablating accessory pathways and reducing the number of RF applications, total RF energy, and radiation exposure as compared with traditional mapping techniques.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Exposição à Radiação , Feixe Acessório Atrioventricular/diagnóstico por imagem , Feixe Acessório Atrioventricular/cirurgia , Adolescente , Fluoroscopia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino
17.
Plant Cell ; 30(11): 2677-2703, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30309901

RESUMO

Chloroplasts import thousands of nucleus-encoded preproteins synthesized in the cytosol through the TOC and TIC translocons on the outer and inner envelope membranes, respectively. Preprotein translocation across the inner membrane requires ATP; however, the import motor has remained unclear. Here, we report that a 2-MD heteromeric AAA-ATPase complex associates with the TIC complex and functions as the import motor, directly interacting with various translocating preproteins. This 2-MD complex consists of a protein encoded by the previously enigmatic chloroplast gene ycf2 and five related nuclear-encoded FtsH-like proteins, namely, FtsHi1, FtsHi2, FtsHi4, FtsHi5, and FtsH12. These components are each essential for plant viability and retain the AAA-type ATPase domain, but only FtsH12 contains the zinc binding active site generally conserved among FtsH-type metalloproteases. Furthermore, even the FtsH12 zinc binding site is dispensable for its essential function. Phylogenetic analyses suggest that all AAA-type members of the Ycf2/FtsHi complex including Ycf2 evolved from the chloroplast-encoded membrane-bound AAA-protease FtsH of the ancestral endosymbiont. The Ycf2/FtsHi complex also contains an NAD-malate dehydrogenase, a proposed key enzyme for ATP production in chloroplasts in darkness or in nonphotosynthetic plastids. These findings advance our understanding of this ATP-driven protein translocation system that is unique to the green lineage of photosynthetic eukaryotes.


Assuntos
Proteínas de Cloroplastos/metabolismo , Proteínas de Plantas/metabolismo , Trifosfato de Adenosina/metabolismo , Cloroplastos/metabolismo , Malato Desidrogenase/metabolismo , Transporte Proteico
18.
Eur Radiol ; 31(5): 3165-3176, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33146796

RESUMO

OBJECTIVES: The early infection dynamics of patients with SARS-CoV-2 are not well understood. We aimed to investigate and characterize associations between clinical, laboratory, and imaging features of asymptomatic and pre-symptomatic patients with SARS-CoV-2. METHODS: Seventy-four patients with RT-PCR-proven SARS-CoV-2 infection were asymptomatic at presentation. All were retrospectively identified from 825 patients with chest CT scans and positive RT-PCR following exposure or travel risks in outbreak settings in Japan and China. CTs were obtained for every patient within a day of admission and were reviewed for infiltrate subtypes and percent with assistance from a deep learning tool. Correlations of clinical, laboratory, and imaging features were analyzed and comparisons were performed using univariate and multivariate logistic regression. RESULTS: Forty-eight of 74 (65%) initially asymptomatic patients had CT infiltrates that pre-dated symptom onset by 3.8 days. The most common CT infiltrates were ground glass opacities (45/48; 94%) and consolidation (22/48; 46%). Patient body temperature (p < 0.01), CRP (p < 0.01), and KL-6 (p = 0.02) were associated with the presence of CT infiltrates. Infiltrate volume (p = 0.01), percent lung involvement (p = 0.01), and consolidation (p = 0.043) were associated with subsequent development of symptoms. CONCLUSIONS: COVID-19 CT infiltrates pre-dated symptoms in two-thirds of patients. Body temperature elevation and laboratory evaluations may identify asymptomatic patients with SARS-CoV-2 CT infiltrates at presentation, and the characteristics of CT infiltrates could help identify asymptomatic SARS-CoV-2 patients who subsequently develop symptoms. The role of chest CT in COVID-19 may be illuminated by a better understanding of CT infiltrates in patients with early disease or SARS-CoV-2 exposure. KEY POINTS: • Forty-eight of 74 (65%) pre-selected asymptomatic patients with SARS-CoV-2 had abnormal chest CT findings. • CT infiltrates pre-dated symptom onset by 3.8 days (range 1-5). • KL-6, CRP, and elevated body temperature identified patients with CT infiltrates. Higher infiltrate volume, percent lung involvement, and pulmonary consolidation identified patients who developed symptoms.


Assuntos
COVID-19 , SARS-CoV-2 , China/epidemiologia , Surtos de Doenças , Humanos , Japão , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
19.
Pacing Clin Electrophysiol ; 44(3): 481-489, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33393087

RESUMO

BACKGROUND: After the reports of recalled leads, several technological improvements have been introduced and the durability of implantable cardioverter defibrillator (ICD) leads has improved. The incidence of lead failures is now less than in the previous studies. However, there are few reports that have shown the long-term durability of ICD leads as compared to pacemaker (PM) leads. This study analyzed the medium to long-term performance of transvenous ICD leads as compared to PM leads. METHODS: We retrospectively studied 1227 cases from April 2007 to December 2017 who underwent an initial transvenous ICD or PM implantation. The number of lead failures and patient background characteristics were analyzed. RESULTS: During a median 3-3.5 years follow up period, 1 (0.3%) ICD lead and 18 (2.4%) PM leads failed. The incidence of lead failures was significantly higher in the PM group than ICD group (p = .019). Males were associated with a higher incidence of lead failures in the PM group. CONCLUSION: Since the era of recalled ICD leads, the durability of ICD leads has remarkably improved and the incidence of lead failures with non-recalled ICD leads has been less than that for PM leads.


Assuntos
Desfibriladores Implantáveis , Eletrodos Implantados , Marca-Passo Artificial , Idoso , Remoção de Dispositivo , Análise de Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores Sexuais
20.
J Infect Chemother ; 27(2): 336-341, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33402303

RESUMO

INTRODUCTION: In patients with severe coronavirus disease 2019 (COVID-19), respiratory failure is a major complication and its symptoms occur around one week after onset. The CURB-65, A-DROP and expanded CURB-65 tools are known to predict the risk of mortality in patients with community-acquired pneumonia. In this retrospective single-center retrospective study, we aimed to assess the correlations of the A-DROP, CURB-65, and expanded CURB-65 scores on admission with an increase in oxygen requirement in patients with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pneumonia. METHODS: We retrospectively analyzed 207 patients who were hospitalized with SARS-CoV-2 pneumonia at the Self-Defense Forces Central Hospital in Tokyo, Japan. Performance of A-DROP, CURB-65, and the expanded CURB-65 scores were validated. In addition, we assessed whether there were any associations between an increase in oxygen requirement and known risk factors for critical illness in COVID-19, including elevation of liver enzymes and C-reactive protein (CRP), lymphocytopenia, high D-dimer levels and the chest computed tomography (CT) score. RESULTS: The areas under the curve for the ability of CURB-65, A-DROP, and the expanded CURB-65 scores to predict an increase in oxygen requirement were 0.6961, 0.6980 and 0.8327, respectively, and the differences between the three groups were statistically significant (p < 0.001). Comorbid cardiovascular disease, lymphocytopenia, elevated CRP, liver enzyme and D-dimer levels, and higher chest CT score were significantly associated with an increase in oxygen requirement CONCLUSIONS: The expanded CURB-65 score can be a better predictor of an increase in oxygen requirement in patients with SARS-CoV-2 pneumonia.


Assuntos
COVID-19/terapia , Oxigenoterapia/métodos , Índice de Gravidade de Doença , Adulto , Idoso , Proteína C-Reativa/análise , COVID-19/epidemiologia , COVID-19/mortalidade , Feminino , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Humanos , Linfopenia/epidemiologia , Masculino , Pessoa de Meia-Idade , Pneumonia Viral/mortalidade , Pneumonia Viral/terapia , Prognóstico , Insuficiência Respiratória/epidemiologia , Estudos Retrospectivos , Fatores de Risco , SARS-CoV-2 , Tóquio , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA