Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Europace ; 19(7): 1101-1108, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-27702865

RESUMO

AIMS: Continuous rhythm monitoring is valuable for adequate atrial fibrillation (AF) management in the clinical setting. Subcutaneous leadless implantable cardiac monitors (ICMs) yield an improved AF detection, overcoming the intrinsic limitations of the currently available external recording systems, thus resulting in a more accurate patient treatment. The study purpose was to assess the detection performance of a novel three-vector ICM device equipped with a dedicated AF algorithm. METHODS AND RESULTS: Sixty-six patients (86.4% males; mean age 60.4 ± 9.4 years) at risk to present AF episodes, having undergone the novel ICM implant (BioMonitor, Biotronik SE&Co. KG, Berlin, Germany), were enrolled. External 48-h ECG Holter was performed 4 weeks after the device implantation. The automatic ICM AF classification was compared with the manual Holter arrhythmia recordings. Of the overall study population, 63/66 (95.5%) had analysable Holter data, 39/63 (62%) showed at least one true AF episode. All these patients had at least one AF episode stored in the ICM. On Holter monitoring, 24/63 (38%) patients did not show AF episodes, in 16 of them (16/24, 67%), the ICM confirmed the absence of AF. The AF detection sensitivity and positive predictive value for episodes' analysis were 95.4 and 76.3%, respectively. CONCLUSION: Continuous monitoring using this novel device, equipped with a dedicated detection algorithm, yields an accurate and reliable detection of AF episodes. The ICM is a promising tool for tailoring individual AF patient management. Further long-term prospective studies are necessary to confirm these encouraging results.


Assuntos
Fibrilação Atrial/diagnóstico , Eletrocardiografia/instrumentação , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Tecnologia de Sensoriamento Remoto/instrumentação , Telemetria/instrumentação , Potenciais de Ação , Idoso , Algoritmos , Fibrilação Atrial/fisiopatologia , Eletrocardiografia Ambulatorial , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Fatores de Tempo
2.
Circulation ; 130(10): 811-9, 2014 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-25052405

RESUMO

BACKGROUND: The management of Wolff-Parkinson-White is based on the distinction between asymptomatic and symptomatic presentations, but evidence is limited in the asymptomatic population. METHODS AND RESULTS: The Wolff-Parkinson-White registry was an 8-year prospective study of either symptomatic or asymptomatic Wolff-Parkinson-White patients referred to our Arrhythmology Department for evaluation or ablation. Inclusion criteria were a baseline electrophysiological testing with or without radiofrequency catheter ablation (RFA). Primary end points were the percentage of patients who experienced ventricular fibrillation (VF) or potentially malignant arrhythmias and risk factors. Among 2169 enrolled patients, 1001 (550 asymptomatic) did not undergo RFA (no-RFA group) and 1168 (206 asymptomatic) underwent ablation (RFA group). There were no differences in clinical and electrophysiological characteristics between the 2 groups except for symptoms. In the no-RFA group, VF occurred in 1.5% of patients, virtually exclusively (13 of 15) in children (median age, 11 years), and was associated with a short accessory pathway antegrade refractory period (P<0.001) and atrioventricular reentrant tachycardia initiating atrial fibrillation (P<0.001) but not symptoms. In the RFA group, ablation was successful in 98.5%, and after RFA, no patients developed malignant arrhythmias or VF over the 8-year follow-up. Untreated patients were more likely to experience malignant arrhythmias and VF (log-rank P<0.001). Time-dependent receiver-operating characteristic curves for predicting VF identified an optimal anterograde effective refractory period of the accessory pathway cutoff of 240 milliseconds. CONCLUSIONS: The prognosis of the Wolff-Parkinson-White syndrome essentially depends on intrinsic electrophysiological properties of AP rather than on symptoms. RFA performed during the same procedure after electrophysiological testing is of benefit in improving the long-term outcomes.


Assuntos
Feixe Acessório Atrioventricular/fisiopatologia , Ablação por Cateter , Síndrome de Wolff-Parkinson-White/fisiopatologia , Síndrome de Wolff-Parkinson-White/cirurgia , Adolescente , Adulto , Arritmias Cardíacas/epidemiologia , Criança , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento , Fibrilação Ventricular/epidemiologia , Síndrome de Wolff-Parkinson-White/mortalidade , Adulto Jovem
3.
J Cardiovasc Dev Dis ; 10(11)2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-37998510

RESUMO

Minimally invasive surgeries for pediatric patients have been proposed for decades, with different approaches in mind. Minimal right axillary thoracotomy (MRAT), proposed two decades ago, allows the preservation of patients' safety alongside faster aesthetic and functional recovery. The MRAT did not become widely adopted due to the prejudice that to follow a minimally invasive approach, safety and efficacy must be compromised. With this study, we aim to compare MRAT to the standard median sternotomy approach with a focus on safety and clinical outcomes. Between January 2017 and April 2021, 216 patients diagnosed with ASD, pAVSD, or PAPVD underwent surgical repair with different approaches in the same period. MRAT was used for 78 patients, and median sternotomy was used for 138 patients. In this last group, standard median sternotomy (SMS) was used for 116 patients, while a minimal skin incision (SMS mini) was used for 22 patients. There were no major complications overall nor in each specific approach. MRAT enabled the successful repair of simple heart defects, providing similar post-operative and cardiological recovery. MRAT does not compromise patients' safety and does not prolong the duration of surgery once the learning curve is overcome, which is generally after 15-20 consecutive operations.

5.
J Thorac Cardiovasc Surg ; 158(1): 141-151, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30745048

RESUMO

BACKGROUND: Long-term survival benefits of full arterial revascularization with radial artery (RA) used in addition to bilateral internal mammary arteries (BIMA) compared with saphenous vein (SV) used in addition to BIMA has not been clearly defined. METHODS: We retrospectively analyzed 660 3-vessel coronary artery disease subjects who received BIMA in addition to either RA (n = 206) or SV (n = 454) grafting in a period between June 1999 and November 2017. After propensity score matching, we obtained 190 matched pairs for analysis. RESULTS: In the matched population, in-hospital mortality occurred in 4 patients (1%), with 2 deaths (1.1%) in the BIMA + RA group and 2 deaths (1.1%) in BIMA + SV group (P > .99). The median follow-up time was 9.2 years (interquartile range, 5.6-13 years) with a maximum follow-up time of 18.5 years. There was not a significant difference in long-term survival between the 2 groups over the follow-up period. Survival at 5, 10, and 15 years were 94.8 ± 1.7%, 83.7 ± 3.1%, and 78.6 ± 3.9% in the BIMA + RA group and 96.2 ± 1.4%, 85.1 ± 2.9%, and 80.4 ± 3.6% in the BIMA + SV group (stratified log-rank P = .78). Cox proportional hazard regression model was used to estimate that the use of RA in addition to BIMA did not affect the late mortality (propensity score adjusted hazard ratio, 1.05; 95% confidence interval, 0.62-1.79; P = .83). CONCLUSIONS: In a relatively small population of triple-vessel coronary artery disease, the use of RA as a third arterial conduit with BIMA did not confer a long-term survival benefit.


Assuntos
Ponte de Artéria Coronária/métodos , Artéria Torácica Interna/transplante , Artéria Radial/transplante , Veia Safena/transplante , Ponte de Artéria Coronária/mortalidade , Doença da Artéria Coronariana/cirurgia , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Análise de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA