Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Constr Build Mater ; 170: 747-756, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29881142

RESUMO

Bond between two cementitious materials is crucial in applications such as repairs, overlays, and connections of prefabricated bridge elements (PBEs), to name just a few. It is the latter that has special interest to the authors of this paper. After performing a dimensional stability study on grout-like materials commonly used as connections between PBEs, it was observed that the so-called 'non-shrink' cementitious grouts showed a considerable amount of early-age shrinkage. This might have negative effects on the integrity of the structure, due not only to the grout material's early degradation, but also to a possible loss of bond between the grout and the prefabricated concrete element. Many factors affect the bond strength between two cementitious materials (e.g., grout-concrete), the presence of moisture at the existing concrete substrate surface being one of them. In this regard, pre-moistening the concrete substrate surface prior to the application of the grout material is sometimes recommended for bond enhancement. This topic has been the focus of numerous research studies in the past; however, there is still controversy among practitioners on the real benefits that this practice might provide. This paper evaluates the tensile bond performance of two non-shrink cementitious grouts applied to the exposed aggregate surface of a concrete substrate, and how the supply of moisture at the grout-concrete interface affects the bond strength. "Pull-off" bond results show increased tensile bond strength when the concrete surface is pre-moistened. Reasons to explain the observed increased bond strength are given after a careful microstructural analysis of the grout-concrete interface. Interfaces where sufficient moisture is provided to the concrete substrate such that moisture movement from the grout is prevented show reduced porosity and increased hydration on the grout side of the interface, which is thought to directly contribute to the increased tensile bond strength.

3.
Euro Surveill ; 17(45)2012 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-23153476

RESUMO

A national laboratory network 'Biotox-Piratox' was created in 2003 in France with the purpose of detecting, confirming and reporting potential biological and chemical threat agents. This network is divided into three levels: Level 1 is dedicated to the evaluation of risks (biological, chemical, radiological), to sampling and packing. Level 2 consists of university and military hospitals, who deal with biological specimens, and of environmental and veterinary laboratories, who deal with environmental and animal samples. Level 3 comprises national reference laboratories and the Jean Mérieux biosafety level (BSL)-4 laboratory in Lyon. This report presents the results of four bio-preparedness exercises to check critical points in the processing of samples. These exercises took place in 2007, 2009, 2010 and 2011. Each of them consisted of two parts. The first part was the identification of an unknown bacterial strain and its susceptibility to antibiotics used as a default in case of a bioterrorist event. The second part was the detection of Class III microorganisms, mainly by molecular techniques. The main lesson learnt in these exercises was that the key to successful detection of biological agents in case of a biological threat was standardisation and validation of the methods implemented by all the laboratories belonging to the network.


Assuntos
Bioterrorismo , Planejamento em Desastres/normas , Laboratórios Hospitalares/normas , Pessoal de Laboratório Médico/educação , Garantia da Qualidade dos Cuidados de Saúde , Redes de Comunicação de Computadores , França , Humanos , Vigilância de Evento Sentinela , Recursos Humanos
4.
Fungal Genet Biol ; 48(12): 1087-95, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21945996

RESUMO

p27 is an antigenic protein produced by Paracoccidioides brasiliensis, the etiologic agent of paracoccidioidomycosis (PCM). Despite its unknown function, it has been suggested as a putative virulence factor, proposed as a suitable target for the design of diagnostic tools and vaccines, and considered as an enhancer in antifungal treatment of PCM. We evaluated sequence polymorphisms of PbP27 gene sequence among isolates, finding some polymorphisms associated with the isolates' phylogenetic origin. In order to determine if there was a differential expression pattern between morphological states and among isolates, we also evaluated PbP27 expression, at transcriptional and translational levels, in mycelia and yeast cultures in 14 isolates belonging to the P. brasiliensis species complex (S1, PS2, PS3, and "Pb01-like", proposed to be named Paracoccidioides lutzii) by two techniques, real time RT-PCR (RT-qPCR) and protein dot blot. For the latter, four protein extracts from different cell localizations (SDS or ß-mercaptoethanol, cytoplasmic and extracellular proteins) were analyzed for each isolate. p27 was present in the four extracts evaluated, mainly in the SDS extract, corresponding to an extract containing proteins loosely attached to the cell wall. This information correlates with immunohistochemical analysis, where positive staining of the yeasts' cell wall was observed. We found that p27 was present in all isolates, mainly in the yeast form. This pattern was corroborated by RT-qPCR results, with higher expression levels found in the yeast form for most of the isolates. The results provide new insights into the expression patterns of this protein, and further characterize it in view of potential uses as a diagnostic and/or therapeutic tool.


Assuntos
Antígenos de Fungos/genética , Proteínas Fúngicas/genética , Paracoccidioides/genética , Antígenos de Fungos/classificação , Antígenos de Fungos/metabolismo , Western Blotting , Parede Celular/metabolismo , Eletroforese em Gel de Poliacrilamida , Proteínas Fúngicas/classificação , Proteínas Fúngicas/metabolismo , Regulação Fúngica da Expressão Gênica , Genes Fúngicos , Imuno-Histoquímica , Paracoccidioides/citologia , Paracoccidioides/crescimento & desenvolvimento , Polimorfismo Genético , Reação em Cadeia da Polimerase em Tempo Real , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Análise de Sequência de DNA , Leveduras/citologia , Leveduras/genética , Leveduras/crescimento & desenvolvimento
5.
J Biopharm Stat ; 21(3): 526-54, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21442524

RESUMO

Estimation of a proportion is commonly used in areas such as medicine, biopharmaceutical experiments, etc. Estimation of a proportion using auxiliary information has not been investigated in the literature. Ratio estimators of the population proportion and two-sided confidence intervals based upon auxiliary information are derived in this paper. Real data extracted from the Spanish National Health Survey are used to demonstrate the application of the proposed methods in the estimation of prevalences. Results derived from simulation studies show that proposed estimators are more efficient than the traditional estimator. Proposed confidence intervals outperform the alternative methods, especially in terms of interval width. A study on patients with hypertension is also considered to calculate various estimators and confidence intervals.


Assuntos
Ensaios Clínicos como Assunto/estatística & dados numéricos , Simulação por Computador , Intervalos de Confiança , Hipertensão/tratamento farmacológico , Modelos Estatísticos , Projetos de Pesquisa/estatística & dados numéricos , Humanos , Método de Monte Carlo , Análise Multivariada , Estudos de Amostragem , Estatística como Assunto
6.
Med Intensiva (Engl Ed) ; 44(3): 160-170, 2020 Apr.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-30245121

RESUMO

INTRODUCTION: Sepsis is associated to a high mortality rate, and its severity must be evaluated quickly. The severity of illness scores used are intended to be applicable to all patient populations, and generally evaluate in-hospital mortality. However, patients with sepsis continue to be at risk of death after hospital discharge. OBJECTIVE: To develop a model for predicting 1-year mortality in critical patients diagnosed with sepsis. PATIENTS: The data corresponding to 5650 admissions of patients with sepsis from the Medical Information Mart for Intensive Care (MIMIC-III) database were evaluated, randomly divided as follows: 70% for training and 30% for validation. DESIGN: A retrospective register-based cohort study was carried out. The clinical information of the first 24h after admission was used to develop a 1-year mortality prediction model based on Stochastic Gradient Boosting (SGB) methodology. Variable selection was addressed using Least Absolute Shrinkage and Selection Operator (LASSO) and SGB variable importance methodologies. The predictive power was evaluated using the area under the ROC curve (AUROC). RESULTS: An AUROC of 0.8039 (95% confidence interval (CI): [0.8033 0.8045]) was obtained in the validation subset. The model exceeded the predictive performances obtained with traditional severity of disease scores in the same subset. CONCLUSION: The use of assembly algorithms, such as SGB, for the generation of a customized model for sepsis yields more accurate 1-year mortality prediction than the traditional scoring systems such as SAPS II, SOFA or OASIS.


Assuntos
Algoritmos , Previsões/métodos , Aprendizado de Máquina , Modelos Estatísticos , Sepse/mortalidade , Idoso , Área Sob a Curva , Estado Terminal/mortalidade , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Curva ROC , Sistema de Registros , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo
7.
Water Sci Technol ; 56(2): 169-78, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17849992

RESUMO

A field study was performed to evaluate the accuracy of six pesticide screening leaching indexes for herbicide movement. Adsorption, dissipation and soil movement were studied in a vineyard in a sandy loam soil during 2005 season. Simazine, diuron, pendimethalin, oxyfluorfen and flumioxazin were applied to bare soil at rates commonly used, and their soil concentrations throughout soil profile were determined at 0, 10, 20, 40 and 90 days after application (DAA). Herbicides were subjected to two pluviometric regimens, natural field condition and modified conditions (plus natural rainfall 180 mm). Leaching indexes utilized were: Briggs's Rf, Hamaker's Rf, LEACH, LPI, GUS and LIX. Simazine reached 120 cm, diuron 90 cm, flumioxazin 30 cm soil depth respectively. Pendimethalin and oxyfluorfen were retained up to 5 cm. None of the herbicides leaching was affected by rainfall regimen. Only flumioxazin field dissipation was clearly affected by pluviometric condition. The best representation of the herbicide soil depth movement and leaching below 15 cm soil depth were: Hamaker's Rf < Briggs's Rf < GUS < LPI, < LEACH < LIX. Field results showed a good correlation between herbicides K(d) and their soil depth movement and mass leached below 15 cm soil depth.


Assuntos
Poluição Ambiental , Herbicidas/análise , Praguicidas/análise , Poluentes do Solo/análise , Vinho , Cinética
8.
Rev Esp Quimioter ; 11(1): 64-9, 1998 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9795292

RESUMO

The E test is a quantitative technique for determining antimicrobial susceptibility; it is based on the diffusion of a stable predetermined gradient of a specific antifungal agent along an inert plastic strip which is applied to a solid culture medium. The E test is an alternative method for determining inhibitory concentrations of antimicrobial agents. The aim of the present study was to determine the in vitro susceptibility of different yeasts to 5 antifungal agents using the E test. The antifungal susceptibility of 87 strains, 73 of which were yeasts obtained from clinical samples, 11 were Prototheca strains and 3 controls, were examined using a gradient diffusion technique (E test). Of these isolates, 13% of Candida albicans were resistant to flucytosine, and 20%, 17% and 33% showed resistance to ketoconazole, itraconazole and fluconazole, respectively. All Candida krusei isolates showed resistance to flucytosine and fluconazole. The Candida parapsilosis and Candida tropicalis strains all presented in vitro susceptibility to all the agents tested. Prototheca strains were only susceptible in vitro to amphotericin B. It was found that the E test was easy to perform, and provided MIC values similar to those obtained with other well documented techniques. It was therefore concluded that the E test could be implemented as a standard procedure in clinical mycology laboratories.


Assuntos
Antifúngicos/farmacologia , Candida/efeitos dos fármacos , Cryptococcus neoformans/efeitos dos fármacos , Testes de Sensibilidade Microbiana/métodos , Prototheca/efeitos dos fármacos , Anfotericina B/farmacologia , Resistência Microbiana a Medicamentos , Fluconazol/farmacologia , Flucitosina/farmacologia , Humanos , Técnicas In Vitro , Itraconazol/farmacologia , Cetoconazol/farmacologia
9.
Rev Inst Med Trop Sao Paulo ; 38(1): 39-44, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8762638

RESUMO

Amebiasis continues to be of epidemiological importance in underdeveloped countries. Clinical diagnosis and epidemiological setting in a region are based on the fecal microscopic identification of cysts or trophozoites. This procedure requires well trained personnel, is laborious, of low sensitivity and frequently yields false-positives results. The present study was designed to develop an immunoenzymatic fecal 96 kDa antigen capture test (COPROELISA-Eh) more sensitive and specific than microscopic diagnosis of amebiasis. Triplicates of 177 stool samples processed by the formol-ether concentration method, were defined as positive or negative by three experienced microscopic observers. Another aliquot was submitted to the antigen capture test by a monoclonal antibody against a specific membrane antigen of pathogenic strains of Entamoeba histolytica. Optical densities were interpreted as positive when they exceeded the mean value of negative samples plus two standard deviations. COPROELISA-Eh showed a 94.4% sensitivity, 98.3% specificity, 96.2% positive predictive value and 97.6% negative predictive value for the detection of E. histolytica in feces. COPROELISA-Eh is more sensitive and specific than microscopic examination, does not require specially trained personnel and allows the simultaneous processing of a large number of samples.


Assuntos
Entamoeba histolytica/imunologia , Entamebíase/diagnóstico , Análise de Variância , Animais , Anticorpos Monoclonais/análise , Antígenos de Protozoários/análise , Distribuição de Qui-Quadrado , Entamoeba histolytica/isolamento & purificação , Entamoeba histolytica/patogenicidade , Ensaio de Imunoadsorção Enzimática/métodos , Fezes/parasitologia , Humanos , Técnicas Imunoenzimáticas , Camundongos , Camundongos Endogâmicos BALB C , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Virulência
10.
An Med Interna ; 12(3): 115-21, 1995 Mar.
Artigo em Espanhol | MEDLINE | ID: mdl-7795117

RESUMO

BASIS: The abdominal manifestations in the patient with HIV infection are increasingly frequent. We have conducted the present study in order to determine the diagnostic usefulness of the abdominal echography in the clinical assessment of the patient. MATERIALS AND METHODS: We review the echographic findings of 112 patients carrying the HIV with or without the Acquired Immunodeficiency Syndrome (AIDS). Seventy eight patients were men and 34, women, with an average age of 30 years. The main risk group was parenterally drug addiction (72%). The stage of the HIV infection was IVC1 in 41% of the cases, II in 23%, III in 13% and IVC2 in 13%. The echographic exploration was performed using a real-time echography, with a probe of 3.5 Mhz, assessing according to conventional criteria the abdominal organs and their pathology, masses and free intraabdominal fluid. The echographic characteristics were first broadly assessed in the patients from the series and later on, according to the patient's pathology. (Infectious, acute abdominal, hepatic biochemical disorders, HIV carrier-associated pathology). RESULTS: In 33% of the cases, the echography was normal. Hepatomegaly was the most frequent echographic sign: 56 patients (50%), followed by splenomegaly in 43 patients (38.3%), standing out the affection of the biliary and/or vesicular ductus in 7 patients (6.2%). The echographic findings were not related to the HIV infection stage, nor with the presence of hepatic biochemical disorders. However, the presence of organomegaly (hepatosplenomegaly associated or not to retroperitoneal adenopathies) were more frequent in the group with infectious complication, 33.3% vs 19.6% (p < 0.01), that in the patients without associated infectious processes. In patients with medical or surgical acute abdominal pathology, the echography was diagnostic in 9 out of 10 patients. CONCLUSION: In the HIV patient, the echography allows an specific initial diagnostic assessment, being able in most of the patients with abdominal manifestations to diagnose the causal pathology.


Assuntos
Abdome/diagnóstico por imagem , Infecções por HIV/complicações , Infecções por HIV/diagnóstico por imagem , Hepatomegalia/diagnóstico por imagem , Hipertensão Portal/diagnóstico por imagem , Doenças Linfáticas/diagnóstico por imagem , Esplenomegalia/diagnóstico por imagem , Abdome Agudo/diagnóstico por imagem , Síndrome da Imunodeficiência Adquirida/complicações , Síndrome da Imunodeficiência Adquirida/diagnóstico , Síndrome da Imunodeficiência Adquirida/diagnóstico por imagem , Adulto , Western Blotting , Ensaio de Imunoadsorção Enzimática , Feminino , Anticorpos Anti-HIV/análise , Infecções por HIV/diagnóstico , Hepatomegalia/etiologia , Humanos , Hipertensão Portal/etiologia , Doenças Linfáticas/etiologia , Masculino , Esplenomegalia/etiologia , Ultrassonografia
11.
Rev Esp Anestesiol Reanim ; 44(2): 62-9, 1997 Feb.
Artigo em Espanhol | MEDLINE | ID: mdl-9148358

RESUMO

OBJECTIVE: To evaluate our application of indications, use and benefits of conventional hemodialysis during surgery in patients with advanced liver disease and acute or chronic renal failure undergoing liver transplantation (LP), liver retransplantation (LRT) or combined hepatorenal transplantation (CHRT). PATIENTS AND METHODS: We retrospectively reviewed the cases of 22 patients with advanced liver disease, 11 with acute renal failure and 11 with chronic renal failure. We performed 6 LT, 5 LRT and 11 CHRT. The following data were recorded in the periods before, during and immediately after surgery: metabolic, hemodynamic and coagulation parameters; bicarbonate, calcium and inotropic drug requirements; incidences during reperfusion of the graft; surgical technique used; and survival. RESULTS: Seven patients (32%) needed hemodialysis, 4 (18%) needed ultrafiltration, 7 (32%) needed both and 4 (18%) required neither. For 6 patients total clamping of the inferior vena cava (ICV) was required with external venovenous bypass. For 8 patients total clamping of the IVC was performed without venovenous bypass. For 8 others IVC clamping was partial with retrohepatic preservation (piggy-back). There were 2 deaths during surgery, 4 more within the first month after surgery and 4 more in the second month. Overall survival was 36.4% among acute patients and 72.7% among CHRT patients. CONCLUSIONS: 1) Conventional hemodialysis during surgery is feasible and gives good results; 2) conventional "high efficiency" hemodialysis is more effective and useful in these patients than is either slow, continuous hemodialysis or filtration; 3) the survival rate of CHRT patients is similar to that of patients undergoing LT with normal kidney function, and 4) partial IVC clamping in the anhepatic phase may decrease the need for ultrafiltration.


Assuntos
Anestesia por Inalação , Cuidados Intraoperatórios/métodos , Transplante de Fígado , Diálise Renal , Insuficiência Renal/terapia , Adjuvantes Anestésicos , Adolescente , Adulto , Constrição , Feminino , Humanos , Complicações Intraoperatórias/mortalidade , Transplante de Rim/métodos , Transplante de Rim/mortalidade , Necrose Tubular Aguda/complicações , Falência Hepática/complicações , Falência Hepática/cirurgia , Transplante de Fígado/métodos , Transplante de Fígado/mortalidade , Masculino , Pessoa de Meia-Idade , Fármacos Neuromusculares não Despolarizantes/administração & dosagem , Complicações Pós-Operatórias/mortalidade , Insuficiência Renal/complicações , Reoperação , Estudos Retrospectivos , Veia Cava Inferior
12.
Nutr Hosp ; 27(1): 306-9, 2012.
Artigo em Espanhol | MEDLINE | ID: mdl-22566339

RESUMO

Endoscopic percutaneous gastrostomy is a safe technique although with potential complications before which the clinician has to be on alert in order to early detect them even after a long period of normal functioning. Most of them represent minor problems. Gastrocolocutaneous fistula is a rare but severe complication favored by some risk factors such as previous post-surgical adherences, deformities of the spine, or excessive gastric inflation at the time of performing the technique. We present the case of a patient with PEG with this complication that occurred after the first tube replacement. Our goal was in two senses: on the one hand, to analyze the preventive aspects and basic guidelines for a safe PEG placement to minimize the risks; on the other hand, to alert on the possible presence of this entity to prevent a progressive nutritional impairment. This complication ought to be included in the differential diagnosis of the diarrhea syndrome in the patient carrying a PEG. The diagnostic techniques of choice are radiologic tests such as CT scan and contrast media administration through the tube. Surgical therapy should be reserved to patients with acute peritonitis in order to perform a new gastrostomy.


Assuntos
Doenças do Colo/etiologia , Fístula Cutânea/etiologia , Endoscopia , Fístula/etiologia , Fístula Gástrica/etiologia , Gastrostomia/efeitos adversos , Adulto , Coma/complicações , Coma/terapia , Diarreia/etiologia , Nutrição Enteral/métodos , Humanos , Masculino , Gestão de Riscos , Tomografia Computadorizada por Raios X
13.
Artigo em Inglês | MEDLINE | ID: mdl-23367187

RESUMO

Predicting the sub-cellular localization of a protein can provide useful information to uncover its molecular functions. In this sense, numerous prediction techniques have been developed, which usually have been focused on global information of the protein or sequence alignments. However, several studies have shown that the functional nature of proteins is ruled by conserved sub-sequence patterns known as domains. In this paper, an alternative methodology (PfamFeat) for gram-positive bacterial sub-cellular localization was developed. PfamFeat is based on information provided by Pfam database, which stores a series of HMM-profiles describing common protein domains. The likelihood of a sequence, to be generated by a given HMM-profile, can be used to characterize sequences in order to use pattern recognition techniques. Success rates obtained with a simple one-nearest neighbor classifier demonstrate that this method is competitive with popular sub-cellular prediction algorithms and it constitutes a promising research trend.


Assuntos
Bactérias Gram-Positivas/metabolismo , Frações Subcelulares/metabolismo , Algoritmos , Biologia Computacional
15.
Med Intensiva ; 34(1): 14-21, 2010.
Artigo em Espanhol | MEDLINE | ID: mdl-20233574

RESUMO

OBJECTIVE: To validate the Spanish version of the CAM-ICU. DESIGN: Validation study. The inter-rater reliability and validity were evaluated using a blind comparison with the DSM-IVTR criteria (reference standard) in a group of patients hospitalized in an Intensive Care Unit (ICU). SETTING: Medical-surgical ICU. PATIENTS: 129 adults with RASS >-4 score, within the 24-48 h of ICU admission. Independent application of the CAM-ICU by two intensive care specialists and evaluation by a psychiatrist using the DSM-IVTR criteria for delirium. RESULTS: Prevalence of delirium in the sample was 26.4%, this being and 48.3% in the 29 patients who received mechanical ventilation. Inter-rater reliability in the whole sample according to the Kappa index was 0.792 (95% CI 0.662-0.922, p<0.001) and in those who received mechanical ventilation was 0.726 (95% CI 0.487-0.965, p<0.001). The sensitivity, specificity, positive predicted value (PPV), negative predicted value (NPV), positive likelihood ratio (+LR), and negative likelihood ratio (-LR) were 79.4% (95% CI 63.2-89.7%); 97.9% (95% CI 92.6-99.4%); 93.1% (95% CI 78.0-98.1%); 93.0% (95% CI 86.3-96.6%); 37.72 (95% CI 9.47-150.20) and 0.21(95% CI 0.11-0.41), respectively, in the whole sample. In mechanically-ventilated patients, sensitivity, specificity, PPV, NPV, +LR and -LR were 92.9% (95% CI 68.5-98.7%); 86.7% (95% CI 62.1-96.3%); 86.7% (95% CI 62.1-96.3%); 92.9% (95% CI 68.5-98.7%); 6.96(95% CI 1.90-25.51) and 0.08 (95% CI 0.01-0.55), respectively. CONCLUSION: The Spanish version of the CAM-ICU is reliable. Its sensitivity, specificity and predictive values should be considered good.


Assuntos
Cuidados Críticos/métodos , Estado Terminal/psicologia , Delírio/diagnóstico , Índice de Gravidade de Doença , Adulto , Idoso , Colômbia/epidemiologia , Coma/diagnóstico , Delírio/epidemiologia , Delírio/psicologia , Demência/diagnóstico , Demência/epidemiologia , Demência/psicologia , Diagnóstico Diferencial , Humanos , Unidades de Terapia Intensiva , Pessoa de Meia-Idade , Variações Dependentes do Observador , Projetos Piloto , Valor Preditivo dos Testes , Prevalência , Reprodutibilidade dos Testes , Respiração Artificial , Sensibilidade e Especificidade , Método Simples-Cego
19.
Med. intensiva (Madr., Ed. impr.) ; 34(1): 14-21, ene.-feb. 2010. tab, ilus
Artigo em Espanhol | IBECS (Espanha) | ID: ibc-80386

RESUMO

Objetivo: Validar la versión en español del CAM-ICU (confusion assessment method for the intensive care unit «método para la evaluación de la confusión en cuidados intensivos»). Diseño: Estudio de validación. Se valoran la concordancia interevaluador y la validez mediante comparación ciega con los criterios del Manual Diagnóstico y Estadístico de los Trastornos Mentales, cuarta edición, texto revisado (DSM-IV TR) (estándar de referencia) en un grupo de pacientes ingresados en una unidad de cuidados intensivos (UCI). Ámbito: UCI médico-quirúrgica. Pacientes: Ciento veintinueve adultos con puntuación >-4 en la Richmond Agitation Sedation Scale y entre las 24-48h de admisión en la UCI. Se tuvo en cuenta la aplicación independiente del CAM-ICU por 2 intensivistas y la valoración por psiquiatría con el uso de los criterios del DSM-IV TR para delírium. Resultados: La prevalencia de delírium en la muestra fue del 26,4% y fue del 48,3% en los 29 pacientes que recibieron ventilación mecánica. La concordancia interevaluador en toda la muestra, según el índice κ fue de 0,792 (intervalo de confianza [IC] del 95%: 0,662-0,922; p<0,001) y en los pacientes con ventilación mecánica fue de 0,726 (IC del 95%: 0,487-0,965; p<0,001). La sensibilidad fue del 79,4% (IC del 95%: 63,2-89,7%); la especificidad, del 97,9% (IC del 95% 92,6-99,4%); el valor predictivo positivo (VP+), del 93,1% (IC del 95%: 78,0-98,1%); el valor predictivo negativo (VP-), del 93,0% (IC del 95%: 86,3-96,6%); el cociente de probabilidades positivo (CP+), de 37,72 (IC del 95%: 9,47-150,20), y el cociente de probabilidades negativo (CP-), de 0,21(IC del 95%: 0,11-0,41) en toda la muestra. En los pacientes con ventilación mecánica, la sensibilidad fue del 92,9% (IC del 95%: 68,5-98,7%); la especificidad, del 86,7% (IC del 95%: 62,1-96,3%); el VP+, del 86,7% (IC del 95%: 62,1-96,3%); el VP-, del 92,9% (IC del 95%: 68,5-98,7%); el CP+, de 6,96 (IC del 95%: 1,90-25,51), y el CP-, de 0,08 (IC del 95%: 0,01-0,55). Conclusión: El CAM-ICU en español es reproducible. Su sensibilidad y especificidad así como sus valores predictivos son buenos (AU)


Objective: To validate the Spanish version of the CAM-ICU. Design: Validation study. The inter-rater reliability and validity were evaluated using a blind comparison with the DSM-IVTR criteria (reference standard) in a group of patients hospitalized in an Intensive Care Unit (ICU). Setting Medical-surgical ICU. Patients 129 adults with RASS >-4 score, within the 24-48h of ICU admission. Independent application of the CAM-ICU by two intensive care specialists and evaluation by a psychiatrist using the DSM-IVTR criteria for delirium. Results: Prevalence of delirium in the sample was 26.4%, this being and 48.3% in the 29 patients who received mechanical ventilation. Inter-rater reliability in the whole sample according to the Kappa index was 0.792 (95% CI 0.662-0.922, p<0.001) and in those who received mechanical ventilation was 0.726 (95% CI 0.487-0.965, p<0.001). The sensitivity, specificity, positive predicted value (PPV), negative predicted value (NPV), positive likelihood ratio (+LR), and negative likelihood ratio (-LR) were 79.4% (95% CI 63.2-89.7%); 97.9% (95% CI 92.6-99.4%); 93.1% (95% CI 78.0-98.1%); 93.0% (95% CI 86.3-96.6%); 37.72 (95% CI 9.47-150.20) and 0.21(95% CI 0.11-0.41), respectively, in the whole sample. In mechanically-ventilated patients, sensitivity, specificity, PPV, NPV, +LR and -LR were 92.9% (95% CI 68.5-98.7%); 86.7% (95% CI 62.1-96.3%); 86.7% (95% CI 62.1-96.3%); 92.9% (95% CI 68.5-98.7%); 6.96(95% CI 1.90-25.51) and 0.08 (95% CI 0.01-0.55), respectively. Conclusion: The Spanish version of the CAM-ICU is reliable. Its sensitivity, specificity and predictive values should be considered good (AU)


Assuntos
Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Índice de Gravidade de Doença , Cuidados Críticos/métodos , Estado Terminal/psicologia , Delírio/diagnóstico , Colômbia , Demência/diagnóstico , Diagnóstico Diferencial , Unidades de Terapia Intensiva , Projetos Piloto , Valor Preditivo dos Testes , Prevalência , Reprodutibilidade dos Testes , Método Simples-Cego
20.
C R Seances Soc Biol Fil ; 182(2): 196-201, 1988.
Artigo em Francês | MEDLINE | ID: mdl-2973827

RESUMO

Triethyltin intoxication induces, in vivo, a significant increase of malondialdehyde concentration in rat brain. After treatment with a Ginkgo biloba extract, an extract known to possess antiedematous and radical scavenging properties, the malondialdehyde level in the brain is significantly decreased. This suggests that a lipid peroxidation process is associated with cerebral oedema induced by triethyltin.


Assuntos
Edema Encefálico/induzido quimicamente , Compostos de Trialquitina/toxicidade , Compostos de Trietilestanho/toxicidade , Animais , Química Encefálica/efeitos dos fármacos , Edema Encefálico/tratamento farmacológico , Fígado/análise , Masculino , Malondialdeído/análise , Malondialdeído/sangue , Extratos Vegetais/uso terapêutico , Ratos , Ratos Endogâmicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA