Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 220
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Br J Haematol ; 204(5): 1660-1671, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38419589

RESUMO

The supply of blood components and products in sufficient quantities is key to any effective health care system. This report describes the challenges faced by the English blood service, NHS Blood and Transplant (NHSBT), towards the end of the COVID-19 pandemic, which in October 2022 led to an Amber Alert being declared to hospitals indicating an impending blood shortage. The impact on the hospital transfusion services and clinical users is explained. The actions taken by NHSBT to mitigate the blood supply challenges and ensure equity of transfusion support for hospitals in England including revisions to the national blood shortage plans are described. This report focuses on the collaboration and communication between NHSBT, NHS England (NHSE), Department of Health and Social Care (DHSC), National Blood Transfusion Committee (NBTC), National Transfusion Laboratory Managers Advisory Group for NBTC (NTLM), National Transfusion Practitioners Network, the medical Royal Colleges and clinical colleagues across the NHS.


Assuntos
Doadores de Sangue , Transfusão de Sangue , COVID-19 , SARS-CoV-2 , Humanos , Inglaterra , COVID-19/epidemiologia , Transfusão de Sangue/estatística & dados numéricos , Doadores de Sangue/provisão & distribuição , Bancos de Sangue/provisão & distribuição , Medicina Estatal/organização & administração , Pandemias
2.
Transfusion ; 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38767410

RESUMO

BACKGROUND: Drugs such as daratumumab (Darzalex, anti-CD38) and Hu5F9-G4 (magrolimab, anti-CD47) may interfere with red blood cell compatibility testing as CD38 and CD47 are expressed on red blood cells. STUDY DESIGN AND METHODS: A survey of AABB member transfusion services was undertaken to understand their experiences of managing patients taking therapeutic monoclonal antibodies that are known to interfere with blood grouping and compatibility testing. RESULTS: The survey was distributed to the contact person at US-based AABB member transfusion services. The response rate was 27%. 172 of 240 (72%) indicated they had difficulties in performing compatibility testing in patients taking daratumumab and 66 of 91 (73%) reported difficulties in performing compatibility testing in patients taking magrolimab. Actions taken to provide compatible blood for these patients included referral of all samples to a reference center, blood group pheno/genotyping the patient in advance of starting the drug, treating reagent cells with 0.2 M dithiothreitol and using K-negative red cell units for patients taking daratumumab, and Gamma-clone (Immucor) anti-IgG for indirect antiglobulin testing for patients taking magrolimab. Lack of communication from clinical services about drug treatment was identified as a concern. CONCLUSION: The results of the survey demonstrate that transfusion services are having challenges with the transfusion management of patients taking therapeutic monoclonal antibodies, and further education is needed.

3.
Transfusion ; 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38769631

RESUMO

BACKGROUND: Blood components are costly and scarce. The Blood Stocks Management Scheme (BSMS) was established in the United Kingdom (UK) to support hospital transfusion services and national blood services through collection, analysis, and monthly feedback of data on blood component inventory and wastage management. There is a growing evidence base on how best to deliver feedback for quality improvement. We assessed the quality and utility of the monthly BSMS component reports. METHODS: We assessed the content of BSMS reports issued in March 2023 against established criteria for effective feedback. Two researchers independently rated whether criteria spanning the five domains of goal setting, data collection, feedback content, feedback display and feedback delivery were fully, partially or not met. Disagreements were resolved through discussion. We conducted an online questionnaire survey of recipients of BSMS reports during March 2023 to assess their use of reports and seek suggestions for improvement. RESULTS: Five out of 20 criteria for effective feedback were fully met. Areas for improvement included placing more emphasis in the feedback on positive change, linking data and summary messages, and including specific suggestions for action. Respondents highlighted the value of benchmarked comparisons with other hospital transfusion services. CONCLUSION: There is scope for enhancing the effectiveness and utility of BSMS feedback reports and hence reducing wastage of blood components. This methodology for evaluation of feedback could be utilized to improve other areas of transfusion practice.

4.
Transfusion ; 64(4): 638-645, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38506497

RESUMO

BACKGROUND: Healthcare activities significantly contribute to greenhouse gas (GHG) emissions. Blood transfusions require complex, interlinked processes to collect, manufacture, and supply. Their contribution to healthcare emissions and avenues for mitigation is unknown. STUDY DESIGN AND METHODS: We performed a life cycle assessment (LCA) for red blood cell (RBC) transfusions across England where 1.36 million units are transfused annually. We defined the process flow with seven categories: donation, transportation, manufacturing, testing, stockholding, hospital transfusion, and disposal. We used direct measurements, manufacturer data, bioengineering databases, and surveys to assess electrical power usage, embodied carbon in disposable materials and reagents, and direct emissions through transportation, refrigerant leakage, and disposal. RESULTS: The central estimate of carbon footprint per unit of RBC transfused was 7.56 kg CO2 equivalent (CO2eq). The largest contribution was from transportation (2.8 kg CO2eq, 36% of total). The second largest was from hospital transfusion processes (1.9 kg CO2eq, 26%), driven mostly by refrigeration. The third largest was donation (1.3 kg CO2eq, 17%) due to the plastic blood packs. Total emissions from RBC transfusion are ~10.3 million kg CO2eq/year. DISCUSSION: This is the first study to estimate GHG emissions attributable to RBC transfusion, quantifying the contributions of each stage of the process. Primary areas for mitigation may include electric vehicles for the blood service fleet, improving the energy efficiency of refrigeration, using renewable sources of electricity, changing the plastic of blood packs, and using methods of disposal other than incineration.


Assuntos
Pegada de Carbono , Efeito Estufa , Humanos , Animais , Transfusão de Sangue , Estágios do Ciclo de Vida , Inglaterra
5.
Transfusion ; 63(4): 839-848, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36811164

RESUMO

BACKGROUND: The optimal method of postgraduate transfusion medicine (TM) education remains understudied. One novel approach is Transfusion Camp, a longitudinal 5-day program that delivers TM education to Canadian and international trainees. The purpose of this study was to determine the self-reported impact of Transfusion Camp on trainee clinical practice. STUDY DESIGN AND METHODS: A retrospective analysis of anonymous survey evaluations from Transfusion Camp trainees over three academic years (2018-2021) was conducted. Trainees were asked, "Have you applied any of your learning from Transfusion Camp into your clinical practice?". Through an iterative process, responses were categorized into topics according to program learning objectives. The primary outcome was the rate of self-reported impact of Transfusion Camp on clinical practice. Secondary outcomes were to determine impact based on specialty and postgraduate year (PGY). RESULTS: Survey response rate was 22%-32% over three academic years. Of 757 survey responses, 68% of respondents indicated that Transfusion Camp had an impact on their practice, increasing to 83% on day 5. The most frequent areas of impact included transfusion indications (45%) and transfusion risk management (27%). Impact increased as PGY increased with 75% of PGY-4+ trainees reporting impact. In multivariable analysis, the impact of specialty and PGY varied depending on the objective. DISCUSSION: The majority of trainees report applying learnings from Transfusion Camp to their clinical practice with variations based on PGY and specialty. These findings support Transfusion Camp as an effective means of TM education and help identify high-yield areas and gaps for future curriculum planning.


Assuntos
Internato e Residência , Humanos , Autorrelato , Estudos Retrospectivos , Canadá , Educação de Pós-Graduação em Medicina , Currículo , Competência Clínica
6.
Transfusion ; 63 Suppl 3: S46-S53, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36971017

RESUMO

BACKGROUND: Questions persist about the safety of switching non-group O recipients of group O uncrossmatched red blood cells (RBC) or low titer group O whole blood (LTOWB) to ABO-identical RBCs during their resuscitation. METHODS: The database of an earlier nine-center study of transfusing incompatible plasma to trauma patients was reanalyzed. The patients were divided into three groups based on 24-h RBC transfusion: (1) group O patients who received group O RBC/LTOWB units (control group, n = 1203), (2) non-group O recipients who received only group O units (n = 646), (3) non-group O recipients who received at least one unit of group O and non-group O units (n = 562). Fixed marginal effect of receipt of non-O RBC units on 6- and 24-h and 30-day mortality was calculated. RESULTS: The non-O patients who received only group O RBCs received fewer RBC/LTOWB units and had slightly but significantly lower injury severity score compared to control group; non-group O patients who received both group O and non-O units received significantly more RBC/LTOWB units and had a slightly but significantly higher injury severity score compared to control group. In the multivariate analysis, the non-O patients who received only group O RBCs had significantly higher mortality at 6-h compared to the controls; the non-group O recipients of O and non-O RBCs did not demonstrate higher mortality. At 24-h and 30-days, there were no differences in survival between the groups. CONCLUSION: Providing non-group O RBCs to non-group O trauma patients who also received group O RBC units is not associated with higher mortality.


Assuntos
Transfusão de Sangue , Ferimentos e Lesões , Humanos , Transfusão de Eritrócitos/efeitos adversos , Ressuscitação , Eritrócitos , Sistema ABO de Grupos Sanguíneos , Ferimentos e Lesões/terapia
7.
Pediatr Blood Cancer ; 70(5): e30258, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36815611

RESUMO

BACKGROUND: Patterns and risks of subsequent primary tumours (SPTs) among long-term survivors of childhood cancer have been extensively described, but much less is known about early SPTs (ESPTs) occurring within 5 years after initial diagnosis. PROCEDURE: We carried out a population-based study of ESPTs following childhood cancer throughout Britain, using the National Registry of Childhood Tumours. The full study series comprised all ESPTs occurring among 56,620 children whose initial cancer diagnosis was in the period 1971-2010. Frequencies of ESPT were calculated for the entire cohort. For analyses of risk, follow-up began 92 days after initial diagnosis. RESULTS: ESPT developed in 0.4% of children overall, 0.52% of those initially diagnosed at age less than 1 year and 0.38% of those diagnosed at age 1-14 years. Standardised incidence ratio (SIR) was 7.7 (95% confidence interval [CI]: 6.7-8.9), overall 9.5 (95% CI: 7.1-12.5) for children initially diagnosed in 1981-1990 and 6.5-7.5 for those from earlier and later decades. SIR by type of first cancer ranged from 4.4 (95% CI: 1.8-9.1) for Wilms tumour to 13.1 (95% CI: 7.7-21.0) for non-Hodgkin lymphoma. SIR by type of ESPT ranged from 2.0 (95% CI: 1.0-3.4) for acute lymphoblastic leukaemia to 66.6 (95% CI: 52.3-83.6) for acute myeloid leukaemia. Predisposition syndromes were known to be implicated in 21% of children with ESPT and suspected in another 5%. CONCLUSIONS: This study provides an overview of the patterns and risks of ESPTs in a large population where many children received therapy that is still in widespread use. Further research will be needed to monitor and understand changes in risk as childhood cancer treatment continues to evolve.


Assuntos
Segunda Neoplasia Primária , Neoplasias , Criança , Humanos , Lactente , Neoplasias/diagnóstico , Neoplasias/epidemiologia , Neoplasias/etiologia , Reino Unido/epidemiologia , Fatores de Risco , Sobreviventes , Incidência , Sistema de Registros , Segunda Neoplasia Primária/diagnóstico , Segunda Neoplasia Primária/epidemiologia
8.
Cochrane Database Syst Rev ; 9: CD001888, 2023 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-37681564

RESUMO

BACKGROUND: Concerns regarding the safety and availability of transfused donor blood have prompted research into a range of techniques to minimise allogeneic transfusion requirements. Cell salvage (CS) describes the recovery of blood from the surgical field, either during or after surgery, for reinfusion back to the patient. OBJECTIVES: To examine the effectiveness of CS in minimising perioperative allogeneic red blood cell transfusion and on other clinical outcomes in adults undergoing elective or non-urgent surgery. SEARCH METHODS: We searched CENTRAL, MEDLINE, Embase, three other databases and two clinical trials registers for randomised controlled trials (RCTs) and systematic reviews from 2009 (date of previous search) to 19 January 2023, without restrictions on language or publication status. SELECTION CRITERIA: We included RCTs assessing the use of CS compared to no CS in adults (participants aged 18 or over, or using the study's definition of adult) undergoing elective (non-urgent) surgery only. DATA COLLECTION AND ANALYSIS: We used standard methodological procedures expected by Cochrane. MAIN RESULTS: We included 106 RCTs, incorporating data from 14,528 participants, reported in studies conducted in 24 countries. Results were published between 1978 and 2021. We analysed all data according to a single comparison: CS versus no CS. We separated analyses by type of surgery. The certainty of the evidence varied from very low certainty to high certainty. Reasons for downgrading the certainty included imprecision (small sample sizes below the optimal information size required to detect a difference, and wide confidence intervals), inconsistency (high statistical heterogeneity), and risk of bias (high risk from domains including sequence generation, blinding, and baseline imbalances). Aggregate analysis (all surgeries combined: primary outcome only) Very low-certainty evidence means we are uncertain if there is a reduction in the risk of allogeneic transfusion with CS (risk ratio (RR) 0.65, 95% confidence interval (CI) 0.59 to 0.72; 82 RCTs, 12,520 participants). Cancer: 2 RCTs (79 participants) Very low-certainty evidence means we are uncertain whether there is a difference for mortality, blood loss, infection, or deep vein thrombosis (DVT). There were no analysable data reported for the remaining outcomes. Cardiovascular (vascular): 6 RCTs (384 participants) Very low- to low-certainty evidence means we are uncertain whether there is a difference for most outcomes. No data were reported for major adverse cardiovascular events (MACE). Cardiovascular (no bypass): 6 RCTs (372 participants) Moderate-certainty evidence suggests there is probably a reduction in risk of allogeneic transfusion with CS (RR 0.82, 95% CI 0.69 to 0.97; 3 RCTs, 169 participants). Very low- to low-certainty evidence means we are uncertain whether there is a difference for volume transfused, blood loss, mortality, re-operation for bleeding, infection, wound complication, myocardial infarction (MI), stroke, and hospital length of stay (LOS). There were no analysable data reported for thrombosis, DVT, pulmonary embolism (PE), and MACE. Cardiovascular (with bypass): 29 RCTs (2936 participants) Low-certainty evidence suggests there may be a reduction in the risk of allogeneic transfusion with CS, and suggests there may be no difference in risk of infection and hospital LOS. Very low- to moderate-certainty evidence means we are uncertain whether there is a reduction in volume transfused because of CS, or if there is any difference for mortality, blood loss, re-operation for bleeding, wound complication, thrombosis, DVT, PE, MACE, and MI, and probably no difference in risk of stroke. Obstetrics: 1 RCT (1356 participants) High-certainty evidence shows there is no difference between groups for mean volume of allogeneic blood transfused (mean difference (MD) -0.02 units, 95% CI -0.08 to 0.04; 1 RCT, 1349 participants). Low-certainty evidence suggests there may be no difference for risk of allogeneic transfusion. There were no analysable data reported for the remaining outcomes. Orthopaedic (hip only): 17 RCTs (2055 participants) Very low-certainty evidence means we are uncertain if CS reduces the risk of allogeneic transfusion, and the volume transfused, or if there is any difference between groups for mortality, blood loss, re-operation for bleeding, infection, wound complication, prosthetic joint infection (PJI), thrombosis, DVT, PE, stroke, and hospital LOS. There were no analysable data reported for MACE and MI. Orthopaedic (knee only): 26 RCTs (2568 participants) Very low- to low-certainty evidence means we are uncertain if CS reduces the risk of allogeneic transfusion, and the volume transfused, and whether there is a difference for blood loss, re-operation for bleeding, infection, wound complication, PJI, DVT, PE, MI, MACE, stroke, and hospital LOS. There were no analysable data reported for mortality and thrombosis. Orthopaedic (spine only): 6 RCTs (404 participants) Moderate-certainty evidence suggests there is probably a reduction in the need for allogeneic transfusion with CS (RR 0.44, 95% CI 0.31 to 0.63; 3 RCTs, 194 participants). Very low- to moderate-certainty evidence suggests there may be no difference for volume transfused, blood loss, infection, wound complication, and PE. There were no analysable data reported for mortality, re-operation for bleeding, PJI, thrombosis, DVT, MACE, MI, stroke, and hospital LOS. Orthopaedic (mixed): 14 RCTs (4374 participants) Very low- to low-certainty evidence means we are uncertain if there is a reduction in the need for allogeneic transfusion with CS, or if there is any difference between groups for volume transfused, mortality, blood loss, infection, wound complication, PJI, thrombosis, DVT, MI, and hospital LOS. There were no analysable data reported for re-operation for bleeding, MACE, and stroke. AUTHORS' CONCLUSIONS: In some types of elective surgery, cell salvage may reduce the need for and volume of allogeneic transfusion, alongside evidence of no difference in adverse events, when compared to no cell salvage. Further research is required to establish why other surgeries show no benefit from CS, through further analysis of the current evidence. More large RCTs in under-reported specialities are needed to expand the evidence base for exploring the impact of CS.


Assuntos
Artrite Infecciosa , Transplante de Células-Tronco Hematopoéticas , Infarto do Miocárdio , Embolia Pulmonar , Acidente Vascular Cerebral , Infecção dos Ferimentos , Feminino , Gravidez , Adulto , Humanos , Procedimentos Cirúrgicos Eletivos , Transfusão de Sangue
9.
Transfus Med ; 33(6): 453-459, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37782004

RESUMO

BACKGROUND: Comparisons of transfusion practice between organisations are time-consuming using manual methods for data collection. We performed a feasibility study to determine whether large-scale transfusion data from three English hospitals could be combined to allow comparisons of transfusion practice. METHODS: Clinical, laboratory and transfusion data from patients discharged between 1 April 2016 and 31 March 2017 were extracted from Patient Administration Systems (PAS), Laboratory Information Management Systems (LIMS), and electronic transfusion systems at three NHS hospitals, which are academic medical centres based in large cities outside London. A centralised database and business intelligence software were used to compare the data. RESULTS: The dataset contained 748 982 episodes of patient care with 91 410 blood components transfused. The study confirms the results of previous studies finding peaks in the ages of transfusion in the 0-4 years age range, in women of childbearing ages, and in males over 60 years. The number of components transfused per 1000 bed days was used as a standardised comparator. Red cell utilisation was 42.4, 40.4 and 49.5 units/1000 bed days and platelet utilisation 11.69, 7.76, and 11.66 units/1000 bed days. 60.5% (6848/11 310) of Group O D negative red cell units were transfused to non-group O D negative recipients. An analysis of component usage highlighted variations in practice, for example platelet usage for cardiac surgery varied from 2.4% to 7.3% across the three hospitals. CONCLUSION: This feasibility study demonstrates that large electronic datasets from hospitals can be combined to identify areas for targeted interventions to improve transfusion practice.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Transfusão de Eritrócitos , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Transfusão de Sangue , Hospitais , Transfusão de Componentes Sanguíneos
10.
Transfusion ; 62 Suppl 1: S185-S192, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35748692

RESUMO

BACKGROUND: Evidence indicates the life-saving benefits of early blood product transfusion in severe trauma resuscitation. Many of these products will be RhD-positive, so understanding the D-alloimmunization rate is important. METHODS: This was a multicenter, retrospective study whereby injured RhD-negative patients between 18-50 years of age who received at least one unit of RhD-positive red blood cells (RBC) or low titer group O whole blood (LTOWB) during their resuscitation between 1 January, 2010 through 31 December, 2019 were identified. If an antibody detection test was performed ≥14 days after the index RhD-positive transfusion then basic demographic information was collected, including whether the patient became D-alloimmunized. The overall D-alloimmunization rate, and the rate stratified by the number of units transfused, were calculated. RESULTS: Data were collected from nine institutions. Five institutions reported fewer than 10 eligible patients each and were excluded. From the remaining four institutions, all from the USA, there were 235 eligible patients; 77 (random effects estimate: 32.7%; 95% CI: 19.1-50.1%) became D-alloimmunized. Three of the institutions reported D-alloimmunization rates ≥38.6%, while the remaining institution's rate was 12.2%. In both random and fixed-effects models, the rate of D-alloimmunization was not significantly different between those who received one RhD-positive unit and those who received multiple RhD-positive units. CONCLUSION: In this large, multicenter study of injured patients, the overall rate of D-alloimmunization fell within the range previously reported. The rate of D-alloimmunization did not increase as the number of transfused RhD-positive units increased. These data can help to inform RhD type selection decisions.


Assuntos
Anemia Hemolítica Autoimune , Sistema do Grupo Sanguíneo Rh-Hr , Sistema ABO de Grupos Sanguíneos , Eritrócitos , Humanos , Isoanticorpos , Estudos Retrospectivos
11.
Transfusion ; 61(9): 2601-2610, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34268775

RESUMO

BACKGROUND: Wrong blood in tube (WBIT) errors can lead to ABO mistransfusions. It is unknown if WBIT errors are more likely in specific healthcare locations or if specific collection practices influence the commission of WBIT errors. STUDY DESIGN AND METHODS: Data on pretransfusion samples from calendar year 2019 were collected retrospectively by 39 transfusion services in nine countries. We compared the proportion of WBIT errors made in emergency departments (EDs), inpatient wards, and outpatient clinics. RESULTS: In total, 143 WBIT errors were detected among 1,394,862 samples for an unadjusted aggregate WBIT proportion of 1.03/10,000 samples. Using a pooled random effects model, the WBIT proportion was estimated to be significantly higher in EDs (1.23/10,000 samples, 95% CI 0.62-2.43) than inpatient wards (0.71/10,000, 95% CI 0.44-1.14; p < .001) or outpatient clinics (0.24/10,000, 95% CI 0.08-0.65; p < .001) and significantly higher in inpatient wards than outpatient clinics (p = .043). The use of electronic positive patient identification (ePPID) systems was associated with a significantly lower WBIT proportion in the ED (odds ratio, OR: 0.32, 95% CI: 0.11-0.96, p = .041), but not in inpatient wards (OR: 0.45, 95% CI: 0.20-1.01, p = .054) or outpatient clinics (OR: 1.95, 95% CI: 0.39-9.74, p = .415). DISCUSSION: Normalized for the number of samples drawn per location, the WBIT proportion in EDs was 1.7 times higher than inpatient wards and 5.1 times higher than outpatient clinics. EDs represent higher-risk clinical locations for WBIT errors, and electronic positive patient identification (ePPID) may provide a greater impact on safety in EDs relative to other clinical areas.


Assuntos
Coleta de Amostras Sanguíneas , Serviço Hospitalar de Emergência , Erros Médicos , Doadores de Sangue , Coleta de Amostras Sanguíneas/efeitos adversos , Transfusão de Sangue , Estudos Transversais , Humanos , Estudos Retrospectivos , Reação Transfusional/etiologia
12.
Transfus Med ; 31(5): 322-327, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34056763

RESUMO

OBJECTIVES: Patients presenting to acute care settings with anaemia are at risk of inadequate investigation and inappropriate blood transfusion. In collaboration with Haematology Specialty Trainee Audit and Research (HaemSTAR), this study set out to assess current red blood cell (RBC) transfusion practice and anaemia management in acute care settings across the United Kingdom. METHODS AND RESULTS: Fifteen different hospitals participated in the study over a period of a month beginning 01 January 2020. Eight-hundred and twenty-eight eligible patients presenting to acute care settings with anaemia received RBC transfusions during this period. Of these, 159 (19.2%) received inappropriate transfusions according to National Institute for Health and Care Excellence guidelines, and 257 (31%) could have been treated with alternatives to transfusion. One-hundred and fifty-four (18.6%) did not have a cause for their anaemia identified by the time they were discharged from hospital, and in over 50% of these cases that was because of inadequate investigation with blood tests, specialist investigation or referral, or both. CONCLUSION: This study found that the appropriateness of transfusion and investigation of anaemia in acute care settings warrant improvement and also demonstrates the value of HaemSTAR in facilitating time-efficient collection of high-quality data.


Assuntos
Anemia , Anemia/terapia , Transfusão de Eritrócitos , Hospitais , Humanos , Reino Unido
13.
Br J Cancer ; 122(8): 1250-1259, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32099095

RESUMO

BACKGROUND: This nationwide study investigated associations between paternal occupational exposure and childhood bone tumours and soft- tissue sarcomas. METHODS: The UK National Registry of Childhood Tumours provided cases of childhood sarcomas born and diagnosed in Great Britain, 1962-2010. Control births, unaffected by childhood cancer, were matched on sex, birth period and birth registration sub-district. Fathers' occupations were assigned to one or more of 33 exposure groups and coded for occupational social class. RESULTS: We analysed 5,369 childhood sarcoma cases and 5380 controls. Total bone tumours, total soft-tissue sarcomas and the subgroups osteosarcoma, rhabdomyosarcoma and Ewing Sarcoma Family of Tumours (ESFT) were considered separately. Significant positive associations were seen between rhabdomyosarcoma and paternal exposure to EMFs (odds ratio = 1.67, CI = 1.22-2.28) and also for ESFT and textile dust (1.93, 1.01-3.63). There were putative protective effects on total bone tumours of paternal dermal exposure to hydrocarbons, metal, metal working or oil mists. CONCLUSIONS: Despite the large size and freedom from bias of this study, our results should be interpreted with caution. Many significance tests were undertaken, and chance findings are to be expected. Nevertheless, our finding of associations between ESFT and paternal exposure to textile dust may support related suggestions in the literature.


Assuntos
Neoplasias Ósseas/etiologia , Exposição Ocupacional/efeitos adversos , Exposição Paterna/efeitos adversos , Sarcoma/etiologia , Estudos de Casos e Controles , Criança , Feminino , Humanos , Masculino , Osteossarcoma/etiologia , Rabdomiossarcoma/etiologia , Sarcoma de Ewing/etiologia
14.
Br J Haematol ; 191(3): 340-346, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32436251

RESUMO

The emerging COVID-19 pandemic has overwhelmed healthcare resources worldwide, and for transfusion services this could potentially result in rapid imbalance between supply and demand due to a severe shortage of blood donors. This may result in insufficient blood components to meet every patient's needs resulting in difficult decisions about which patients with major bleeding do and do not receive active transfusion support. This document, which was prepared on behalf of the National Blood Transfusion Committee in England, provides a framework and triage tool to guide the allocation of blood for patients with massive haemorrhage during severe blood shortage. Its goal is to provide blood transfusions in an ethical, fair, and transparent way to ensure that the greatest number of life years are saved. It is based on an evidence- and ethics-based Canadian framework, and would become operational where demand for blood greatly exceeds supply, and where all measures to manage supply and demand have been exhausted. The guidance complements existing national shortage plans for red cells and platelets.


Assuntos
Betacoronavirus , Bancos de Sangue , Doadores de Sangue , Infecções por Coronavirus , Alocação de Recursos para a Atenção à Saúde , Pandemias , Pneumonia Viral , Triagem , Humanos , Bancos de Sangue/normas , Doadores de Sangue/provisão & distribuição , Transfusão de Sangue/métodos , Procedimentos Médicos e Cirúrgicos sem Sangue , Infecções por Coronavirus/epidemiologia , COVID-19 , Planejamento em Desastres , Alocação de Recursos para a Atenção à Saúde/ética , Alocação de Recursos para a Atenção à Saúde/métodos , Alocação de Recursos para a Atenção à Saúde/normas , Hemorragia/epidemiologia , Hemorragia/terapia , Pneumonia Viral/epidemiologia , SARS-CoV-2 , Triagem/ética , Triagem/métodos , Triagem/normas , Reino Unido/epidemiologia
15.
J Pediatr ; 217: 98-109.e8, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31810630

RESUMO

OBJECTIVE: To summarize the published evidence regarding the association between maternal infection during pregnancy and childhood leukemia. STUDY DESIGN: In this systematic review and meta-analysis (PROSPERO number, CRD42018087289), we searched PubMed and Embase to identify relevant studies. We included human studies that reported associations of at least one measure of maternal infection during pregnancy with acute lymphoblastic leukemia (ALL) or all childhood leukemias in the offspring. One reviewer extracted the data first using a standardized form, and the second reviewer independently checked the data for accuracy. Two reviewers used the Newcastle-Ottawa Scale to assess the quality of included studies. We conducted random effects meta-analyses to pool the ORs of specific type of infection on ALL and childhood leukemia. RESULTS: This review included 20 studies (ALL, n = 15; childhood leukemia, n = 14) reported in 32 articles. Most (>65%) included studies reported a positive association between infection variables and ALL or childhood leukemia. Among specific types of infection, we found that influenza during pregnancy was associated with higher risk of ALL (pooled OR, 3.64; 95% CI, 1.34-9.90) and childhood leukemia (pooled OR, 1.77; 95% CI, 1.01-3.11). Varicella (pooled OR, 10.19; 95% CI, 1.98-52.39) and rubella (pooled OR, 2.79; 95% CI, 1.16-6.71) infections were also associated with higher childhood leukemia risk. CONCLUSIONS: Our findings suggest that maternal infection during pregnancy may be associated with a higher risk of childhood leukemia.


Assuntos
Leucemia/etiologia , Complicações Infecciosas na Gravidez/epidemiologia , Efeitos Tardios da Exposição Pré-Natal/epidemiologia , Criança , Feminino , Saúde Global , Humanos , Incidência , Leucemia/epidemiologia , Gravidez , Fatores de Risco
16.
Transfusion ; 60(9): 2153-2155, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32830320

RESUMO

Transfusion of an incorrect blood component is an important avoidable serious hazard of transfusion resulting from process errors. Our group and others have taken advantage of new technology and developed electronic transfusion systems for safe transfusion practice in a previous studies. They allow the clinical staff to correctly identify the patient and the blood product at the bedside, ensuring the right blood product is given to the right patient. This video is to demonstrate the process and not to promote any specific product. It is a follow up our previous video clip on electronic remote blood issue in a previous study. The process for correct patient identification originates from the wristband, which contains the patient identification details in a 2D barcode and is printed from the electronic patient record system. These details are associated with the blood sample through using a portable printer to produce a label for the sample tube. The patient details are scanned into the blood bank laboratory information system (LIS) and are then printed on a compatibility label by the LIS, which also contains a 2-dimensional barcode, and is then attached to the blood product. Following an initial visual check of these details by the clinical staff, the electronic bedside system requires that both the patient wristband barcode and the blood product compatibility barcode are scanned. This will electronically verify at the patient's bedside that the right unit is to be given to the right patient. This is the final step in ensuring end-to-end electronic control and safe transfusion practice.


Assuntos
Bancos de Sangue , Incompatibilidade de Grupos Sanguíneos/prevenção & controle , Transfusão de Sangue , Processamento Eletrônico de Dados , Registros Eletrônicos de Saúde , Incompatibilidade de Grupos Sanguíneos/sangue , Humanos
17.
Transfusion ; 60(8): 1658-1665, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32643142

RESUMO

This report describes the evolution of the electronic clinical decision support system (CDSS) and feedback methods at our center and the challenges and lessons learned. The electronic blood product order with integrated CDSS ensures collection of data regarding the patient's clinical condition and the justification for the blood product order. An alert is generated in real time if the order is placed outside agreed guidelines. We have provided feedback in several ways. We began with monthly review meetings with the junior hematology clinicians responsible for ordering blood. This was successful in reducing unjustified transfusions in this setting. We expanded the feedback to the rest of our hospitals in two ways. First, a dashboard was developed allowing visualization of ordering data by clinicians. Second, these data were summarized on a quarterly basis into a report circulated to the senior clinical staff by e-mail. Finally, a daily report collates all orders placed for blood products that have triggered a CDSS alert from the previous day. A multidisciplinary team reviews these daily. If an order appears unjustified the specialist transfusion clinician contacts the prescribing clinician to ask for further information and, if necessary, provides education. The CDSS and feedback, allied with other patient blood management measures, have reduced total blood product costs for our hospitals by 26% over 6 years. The description of how we have developed and implemented CDSS and feedback to influence transfusion practice may be of particular value to others developing their own systems.


Assuntos
Doadores de Sangue , Transfusão de Sangue/economia , Sistemas de Apoio a Decisões Clínicas/economia , Sistemas Computadorizados de Registros Médicos/economia , Custos e Análise de Custo , Humanos
18.
Transfusion ; 60(11): 2517-2528, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32901965

RESUMO

BACKGROUND: This study investigated the effect on mortality of transfusing ABO-incompatible plasma from all sources during trauma resuscitation. METHODS: Demographic, transfusion, and survival data were retrospectively extracted on civilian trauma patients. Patients were divided by receipt of any quantity of ABO-incompatible plasma from any blood product (incompatible group) or receipt of solely ABO-compatible plasma (compatible group). The primary outcome was 30-day mortality, while other outcomes included 6- and 24-hour mortality. Mixed-effects logistic regression was used to model the effect of various predictor variables, including receipt of incompatible plasma, on mortality outcomes. RESULTS: Nine hospitals contributed data on a total of 2618 trauma patients. There were 1282 patients in the incompatible group and 1336 patients in the compatible group. In both the unadjusted and adjusted models, the 6-hour, 24-hour, and 30-day mortality rates were not significantly different between these groups. The patients in the incompatible group were then divided into high volume (>342 mL) and low volume (≤342 mL) incompatible plasma recipients. In the adjusted model, the high-volume group had higher 24-hour mortality when the Trauma Injury Severity Score survival prediction was >50%. Mortality at 6 hours and 30 days was not higher in this model. The low-volume group did not have increased mortality at any of the time points in this adjusted model. CONCLUSION: The transfusion of incompatible plasma in civilian trauma resuscitation does not lead to higher 30-day mortality. The finding of higher mortality in a select group of recipients in the secondary analysis warrants further study.


Assuntos
Sistema ABO de Grupos Sanguíneos/sangue , Transfusão de Componentes Sanguíneos , Incompatibilidade de Grupos Sanguíneos , Modelos Biológicos , Ressuscitação , Ferimentos e Lesões , Adulto , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida , Índices de Gravidade do Trauma , Ferimentos e Lesões/sangue , Ferimentos e Lesões/mortalidade , Ferimentos e Lesões/terapia
19.
Anesthesiology ; 132(3): 525-534, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31789634

RESUMO

BACKGROUND: Group O erythrocytes and/or whole blood are used for urgent transfusions in patients of unknown blood type. This study investigated the impact of transfusing increasing numbers of uncrossmatched type O products on the recipient's first in-hospital ABO type. METHODS: This was a retrospective cohort study. Results of the first ABO type obtained in adult, non-type O recipients (i.e., types A, B, AB) after receiving at least one unit of uncrossmatched type O erythrocyte-containing product(s) for any bleeding etiology were analyzed along with the number of uncrossmatched type O erythrocyte-containing products administered in the prehospital and/or in hospital setting before the first type and screen sample was drawn. RESULTS: There were 10 institutions that contributed a total of 695 patient records. Among patients who received up to 10 uncrossmatched type O erythrocyte-containing products, the median A antigen agglutination strength in A and AB individuals on forward typing (i.e., testing the recipient's erythrocytes for A and/or B antigens) was the maximum (4+), whereas the median B antigen agglutination strength among B and AB recipients of up to 10 units was 3 to 4+. The median agglutination strength on the reverse type (i.e., testing the recipient's plasma for corresponding anti-A and -B antibodies) was very strong, between 3 and 4+, for recipients of up to 10 units of uncrossmatched erythrocyte-containing products. Overall, the ABO type of 665 of 695 (95.7%; 95% CI, 93.9 to 97.0%) of these patients could be accurately determined on the first type and screen sample obtained after transfusion of uncrossmatched type O erythrocyte-containing products. CONCLUSIONS: The transfusion of smaller quantities of uncrossmatched type O erythrocyte-containing products, in particular up to 10 units, does not usually interfere with determining the recipient's ABO type. The early collection of a type and screen sample is important.


Assuntos
Sistema ABO de Grupos Sanguíneos , Tipagem e Reações Cruzadas Sanguíneas/métodos , Transfusão de Sangue/métodos , Transfusão de Eritrócitos/métodos , Adulto , Aglutinação , Estudos de Coortes , Serviços Médicos de Emergência , Hemorragia/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Ferimentos e Lesões/terapia
20.
Vox Sang ; 115(4): 293-302, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32034773

RESUMO

BACKGROUND AND OBJECTIVES: Responding to national and local pressures to reduce the amount of blood transfused, the haematology department of Oxford University Hospitals (OUH), UK implemented an electronic blood-ordering system with clinical decision support. This intervention targeted junior doctors, giving regular feedback on their transfusion practices with respect to clinical guidelines. METHODS: We evaluated the incremental costs of the intervention using interrupted time series methods to compare red blood cell and platelet usage before and after the intervention was implemented. Difference-in-differences analysis was used to control for external factors that would affect the use of blood products over time. Reductions in blood usage were balanced against intervention costs. RESULTS: The base case analysis showed an average cost saving to the department of £89 304 annually as a result of the intervention. Scenario analyses suggested that the savings may have been greater still, had the increasing trend in blood use prior to the intervention continued in the absence of the intervention. CONCLUSION: An electronic blood-ordering system with clinical decision support can reduce blood transfusions and associated healthcare costs. Focusing on improving junior doctors' transfusion practice is expected to have a knock-on benefit in terms of dissemination of good transfusion practice both within their own department and others as they continue their training.


Assuntos
Transfusão de Sangue/economia , Sistemas de Apoio a Decisões Clínicas/economia , Transfusão de Sangue/estatística & dados numéricos , Custos e Análise de Custo , Sistemas de Apoio a Decisões Clínicas/normas , Retroalimentação , Hospitais Universitários/economia , Hospitais Universitários/estatística & dados numéricos , Humanos , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA