Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Prostate Int ; 4(1): 7-10, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27014657

RESUMO

BACKGROUND: Although primary treatment of localized prostate cancer provides excellent oncologic control, some men who chose radiotherapy experience a recurrence of disease. There is no consensus on the most appropriate management of these patients after radiotherapy failure. In this single-institution review, we compare our oncologic outcome and toxicity between salvage prostatectomy and cryotherapy treatments. METHODS: From January 2004 to June 2013, a total of 23 salvage procedures were performed. Six of those patients underwent salvage prostatectomy while 17 underwent salvage cryotherapy by two high-volume fellowship-trained urologists. Patients being considered for salvage therapy had localized disease at presentation, a prostate-specific antigen (PSA) < 10 ng/mL at recurrence, life expectancy > 10 years at recurrence, and a negative metastatic workup. Patients were followed to observe cancer progression and toxicity of treatment. RESULTS: Patients who underwent salvage cryotherapy were statistically older with a higher incidence of hypertension than our salvage prostatectomy cohort. With a mean follow up of 14.1 months and 7.2 months, the incidence of disease progression was 23.5% and 16.7% after salvage cryotherapy and prostatectomy, respectively. The overall complication rate was also 23.5% versus 16.7%, with the most frequent complication after salvage cryotherapy being urethral stricture and after salvage prostatectomy being severe urinary incontinence. There were no rectal injuries with salvage prostatectomy and one rectourethral fistula in the cohort after salvage cryotherapy. CONCLUSION: While recurrences from primary radiotherapy for prostate cancer do occur, there is no consensus on its management. In our experience, salvage procedures were generally safe and effective. Both salvage cryotherapy and salvage prostatectomy allow for adequate cancer control with minimal toxicity.

2.
Eur Urol ; 68(1): 86-94, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25484140

RESUMO

BACKGROUND: Laparoscopic and robotic simple prostatectomy (SP) have been introduced with the aim of reducing the morbidity of the standard open technique. OBJECTIVE: To report a large multi-institutional series of minimally invasive SP (MISP). DESIGN, SETTING, AND PARTICIPANTS: Consecutive cases of MISP done for the treatment of bladder outlet obstruction (BOO) due to benign prostatic enlargement (BPE) between 2000 and 2014 at 23 participating institutions in the Americas and Europe were included in this retrospective analysis. INTERVENTION: Laparoscopic or robotic SP. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Demographic data and main perioperative outcomes were gathered and analyzed. A multivariable analysis was conducted to identify factors associated with a favorable trifecta outcome, arbitrarily defined as a combination of the following postoperative events: International Prostate Symptom Score <8, maximum flow rate >15ml/s, and no perioperative complications. RESULTS AND LIMITATIONS: Overall, 1330 consecutive cases were analyzed, including 487 robotic (36.6%) and 843 laparoscopic (63.4%) SP cases. Median overall prostate volume was 100ml (range: 89-128). Median estimated blood loss was 200ml (range: 150-300). An intraoperative transfusion was required in 3.5% of cases, an intraoperative complication was recorded in 2.2% of cases, and the conversion rate was 3%. Median length of stay was 4 d (range: 3-5). On pathology, prostate cancer was found in 4% of cases. Overall postoperative complication rate was 10.6%, mostly of low grade. At a median follow-up of 12 mo, a significant improvement was observed for subjective and objective indicators of BOO. Trifecta outcome was not significantly influenced by the type of procedure (robotic vs laparoscopic; p=0.136; odds ratio [OR]: 1.6; 95% confidence interval [CI], 0.8-2.9), whereas operative time (p=0.01; OR: 0.9; 95% CI, 0.9-1.0) and estimated blood loss (p=0.03; OR: 0.9; 95% CI, 0.9-1.0) were the only two significant factors. Retrospective study design, lack of a control arm, and limited follow-up represent major limitations of the present analysis. CONCLUSIONS: This study provides the largest outcome analysis reported for MISP for BOO/BPE. These findings confirm that SP can be safely and effectively performed in a minimally invasive fashion in a variety of healthcare settings in which specific surgical expertise and technology is available. MISP can be considered a viable surgical treatment in cases of large prostatic adenomas. The use of robotic technology for this indication can be considered in centers that have a robotic program in place for other urologic indications. PATIENT SUMMARY: Analysis of a large data set from multiple institutions shows that surgical removal of symptomatic large prostatic adenomas can be carried out with good outcomes by using robot-assisted laparoscopy.


Assuntos
Adenocarcinoma/cirurgia , Adenoma/cirurgia , Complicações Pós-Operatórias/epidemiologia , Próstata/cirurgia , Hiperplasia Prostática/cirurgia , Neoplasias da Próstata/cirurgia , Obstrução do Colo da Bexiga Urinária/cirurgia , Idoso , Estudos de Coortes , Europa (Continente)/epidemiologia , Humanos , Laparoscopia , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Próstata/patologia , Prostatectomia , Hiperplasia Prostática/complicações , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos , Estados Unidos/epidemiologia , Obstrução do Colo da Bexiga Urinária/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA