Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
AJR Am J Roentgenol ; 218(3): 396-404, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34612678

RESUMO

Pulmonary CTA is a ubiquitous study interpreted by radiologists with different levels of experience in a variety of practice settings. Pulmonary embolism (PE) can range from an incidental and clinically insignificant finding to a clinically significant thrombus that can be managed on an outpatient basis to a potentially fatal condition requiring immediate medical or invasive management. Accordingly, a clear and concise pulmonary CTA report should effectively communicate the most pertinent findings to help the treating medical team diagnose or exclude PE and provide information to guide appropriate management. In this Expert Panel Narrative Review, we discuss the purpose of the radiology report for pulmonary CTA, the optimal report format, and the relevant findings that need to be addressed and their clinical significance.


Assuntos
Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Artéria Pulmonar/diagnóstico por imagem
2.
Curr Rheumatol Rep ; 24(5): 166-173, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35499699

RESUMO

PURPOSE OF REVIEW: Interstitial lung disease (ILD) is a common manifestation of systemic sclerosis (SSc). We explore the importance of early detection, monitoring, and management of SSc-ILD. RECENT FINDINGS: All patients with SSc are at risk of ILD and should be screened for ILD at diagnosis using a high-resolution computed tomography (HRCT) scan. Some patients with SSc-ILD develop a progressive phenotype characterized by worsening fibrosis on HRCT, decline in lung function, and early mortality. To evaluate progression and inform treatment decisions, regular monitoring is important and should include pulmonary function testing, evaluation of symptoms and quality of life, and, where indicated, repeat HRCT. Multidisciplinary discussion enables comprehensive evaluation of the available information and its implications for management. The first-line treatment for SSc-ILD is usually immunosuppression. The antifibrotic drug nintedanib has been approved for slowing lung function decline in patients with SSc-ILD. Optimal management of patients with SSc-ILD requires a multidisciplinary and patient-centered approach.


Assuntos
Doenças Pulmonares Intersticiais , Escleroderma Sistêmico , Fibrose , Humanos , Pulmão , Doenças Pulmonares Intersticiais/diagnóstico , Doenças Pulmonares Intersticiais/tratamento farmacológico , Doenças Pulmonares Intersticiais/etiologia , Qualidade de Vida , Testes de Função Respiratória
3.
AJR Am J Roentgenol ; 217(2): 336-346, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32936016

RESUMO

BACKGROUND. Transthoracic echocardiography (TTE) is the standard of care for initial evaluation of patients with suspected cardioembolic stroke. Although TTE is useful for assessing certain sources of cardiac emboli, its diagnostic capability is limited in the detection of other sources, including left atrial thrombus and aortic plaques. OBJECTIVE. The purpose of this article was to investigate sensitivity, specificity, and predictive value of cardiac CTA (CCTA), cardiac MRI (CMRI), and TTE for recurrence in patients with suspected cardioembolic stroke. METHODS. We retrospectively included 151 patients with suspected cardioembolic stroke who underwent TTE and either CMRI (n = 75) or CCTA (n = 76) between January 2013 and May 2017. We evaluated for the presence of left atrial thrombus, left ventricular thrombus, vulnerable aortic plaque, cardiac tumors, and valvular vegetation as causes of cardioembolic stroke. The end point was stroke recurrence. Sensitivity, specificity, PPV, and NPV for recurrent stroke were calculated; the diagnostic accuracy of CMRI, CCTA, and TTE was compared between and within groups using AUC. RESULTS. Twelve and 14 recurrent strokes occurred in the CCTA and CMRI groups, respectively. Sensitivity, specificity, PPV, and NPV were 33.3%, 93.7%, 50.0%, and 88.2% for CCTA; 14.3%, 80.3%, 14.3%, and 80.3% for CMRI; 14.3%, 83.6%, 16.7%, and 80.9% for TTE in the CMRI group; and 8.3%, 93.7%, 20.0%, and 84.5% for TTE in the CCTA group. Accuracy was not different (p > .05) between CCTA (AUC = 0.63; 95% CI, 0.49-0.77), CMRI (0.53; 95% CI, 0.42-0.63), TTE in the CMRI group (0.51; 95% CI, 0.40-0.61), and TTE in the CCTA group (0.51; 95% CI, 0.42-0.59). In the CCTA group, atrial and ventricular thrombus were detected by CCTA in three patients and TTE in one patient; in the CMRI group, thrombus was detected by CMRI in one patient and TTE in two patients. CONCLUSION. CCTA, CMRI, and TTE showed comparably high specificity and NPV for cardioembolic stroke recurrence. CCTA and CMRI may be valid alternatives to TTE. CCTA may be preferred given potentially better detection of atrial and ventricular thrombus. CLINICAL IMPACT. CCTA and CMRI have similar clinical performance as TTE for predicting cardioembolic stroke recurrence. This observation may be especially important when TTE provides equivocal findings.


Assuntos
Ecocardiografia/métodos , AVC Embólico/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Estudos Retrospectivos , Sensibilidade e Especificidade
4.
AJR Am J Roentgenol ; 214(5): 1065-1071, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32130041

RESUMO

OBJECTIVE. The purpose of this study was to evaluate an artificial intelligence (AI)-based prototype algorithm for fully automated quantification of emphysema on chest CT compared with pulmonary function testing (spirometry). MATERIALS AND METHODS. A total of 141 patients (72 women, mean age ± SD of 66.46 ± 9.7 years [range, 23-86 years]; 69 men, mean age of 66.72 ± 11.4 years [range, 27-91 years]) who underwent both chest CT acquisition and spirometry within 6 months were retrospectively included. The spirometry-based Tiffeneau index (TI; calculated as the ratio of forced expiratory volume in the first second to forced vital capacity) was used to measure emphysema severity; a value less than 0.7 was considered to indicate airway obstruction. Segmentation of the lung based on two different reconstruction methods was carried out by using a deep convolution image-to-image network. This multilayer convolutional neural network was combined with multilevel feature chaining and depth monitoring. To discriminate the output of the network from ground truth, an adversarial network was used during training. Emphysema was quantified using spatial filtering and attenuation-based thresholds. Emphysema quantification and TI were compared using the Spearman correlation coefficient. RESULTS. The mean TI for all patients was 0.57 ± 0.13. The mean percentages of emphysema using reconstruction methods 1 and 2 were 9.96% ± 11.87% and 8.04% ± 10.32%, respectively. AI-based emphysema quantification showed very strong correlation with TI (reconstruction method 1, ρ = -0.86; reconstruction method 2, ρ = -0.85; both p < 0.0001), indicating that AI-based emphysema quantification meaningfully reflects clinical pulmonary physiology. CONCLUSION. AI-based, fully automated emphysema quantification shows good correlation with TI, potentially contributing to an image-based diagnosis and quantification of emphysema severity.


Assuntos
Inteligência Artificial , Enfisema Pulmonar/diagnóstico por imagem , Testes de Função Respiratória , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
5.
Radiology ; 293(2): 260-271, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31502938

RESUMO

In this article, the authors discuss the technical background and summarize the current body of literature regarding virtual monoenergetic (VM) images derived from dual-energy CT data, which can be reconstructed between 40 and 200 keV. Substantially improved iodine attenuation at lower kiloelectron volt levels and reduced beam-hardening artifacts at higher kiloelectron volt levels have been demonstrated from all major manufacturers of dual-energy CT units. Improved contrast attenuation with VM imaging at lower kiloelectron volt levels enables better delineation and diagnostic accuracy in the detection of various vascular or oncologic abnormalities. Low-kiloelectron-volt VM imaging may be useful for salvaging CT studies with suboptimal contrast material delivery or providing additional information on the arterial vasculature obtained from venous phase acquisitions. For patients with renal impairment, substantial reductions in the use of iodinated contrast material can be achieved by using lower-energy VM imaging. The authors recommend routine reconstruction of VM images at 50 keV when using dual-energy CT to exploit the increased contrast properties. For reduction of beam-hardening artifacts, VM imaging at 120 keV is useful for the initial assessment.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Artefatos , Doenças Cardiovasculares/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Humanos , Neoplasias/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
6.
Eur Radiol ; 29(9): 4783-4793, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30805703

RESUMO

OBJECTIVES: To investigate the diagnostic accuracy of a modified three-material decomposition calcium subtraction (CS) algorithm for the detection of arterial stenosis in dual-energy CT angiography (DE-CTA) of the lower extremity runoff compared to standard image reconstruction, using digital subtraction angiography (DSA) as the reference standard. METHODS: Eighty-eight patients (53 males; mean age, 65.9 ± 11 years) with suspected peripheral arterial disease (PAD) who had undergone a DE-CTA examination of the lower extremity runoff between May 2014 and May 2015 were included in this IRB-approved, HIPAA-compliant retrospective study. Standard linearly blended and CS images were reconstructed and vascular contrast-to-noise ratios (CNR) were calculated. Two independent observers assessed subjective image quality using a 5-point Likert scale. Diagnostic accuracy for ≥ 50% stenosis detection was analyzed in a subgroup of 45 patients who had undergone additional DSA. Diagnostic accuracy parameters were estimated with a random-effects logistic regression analysis and compared using generalized estimating equations. RESULTS: CS datasets showed higher CNR (15.3 ± 7.3) compared to standard reconstructions (13.5 ± 6.5, p < 0.001). Both reconstructions showed comparable qualitative image quality scores (CS, 4.64; standard, 4.57; p = 0.220). Diagnostic accuracy (sensitivity, specificity, positive and negative predictive values) for CS reconstructions was 96.5% (97.5%, 95.6%, 90.9%, 98.1) and 93.1% (98.8%, 90.4%, 82.3%, 99.1%) for standard images. CONCLUSIONS: A modified three-material decomposition CS algorithm provides increased vascular CNR, equivalent qualitative image quality, and greater diagnostic accuracy for the detection of significant arterial stenosis of the lower extremity runoff on DE-CTA compared with standard image reconstruction. KEY POINTS: • Calcified plaques may lead to overestimation of stenosis severity and false positive results, requiring additional invasive digital subtraction angiography (DSA). • A modified three-material decomposition algorithm for calcium subtraction provides greater diagnostic accuracy for the detection of significant arterial stenosis of the lower extremity runoff compared with standard image reconstruction. • The application of this algorithm in patients with heavily calcified vessels may be helpful to potentially reduce inconclusive CT angiography examinations and the need for subsequent invasive DSA.


Assuntos
Angiografia Digital/métodos , Arteriopatias Oclusivas/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Extremidade Inferior/irrigação sanguínea , Idoso , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Calcificação Vascular/diagnóstico por imagem
7.
Eur Radiol ; 29(5): 2378-2387, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30523456

RESUMO

OBJECTIVES: We sought to investigate the diagnostic performance of coronary CT angiography (cCTA)-derived plaque markers combined with deep machine learning-based fractional flow reserve (CT-FFR) to identify lesion-specific ischemia using invasive FFR as the reference standard. METHODS: Eighty-four patients (61 ± 10 years, 65% male) who had undergone cCTA followed by invasive FFR were included in this single-center retrospective, IRB-approved, HIPAA-compliant study. Various plaque markers were derived from cCTA using a semi-automatic software prototype and deep machine learning-based CT-FFR. The discriminatory value of plaque markers and CT-FFR to identify lesion-specific ischemia on a per-vessel basis was evaluated using invasive FFR as the reference standard. RESULTS: One hundred three lesion-containing vessels were investigated. 32/103 lesions were hemodynamically significant by invasive FFR. In a multivariate analysis (adjusted for Framingham risk score), the following markers showed predictive value for lesion-specific ischemia (odds ratio [OR]): lesion length (OR 1.15, p = 0.037), non-calcified plaque volume (OR 1.02, p = 0.007), napkin-ring sign (OR 5.97, p = 0.014), and CT-FFR (OR 0.81, p < 0.0001). A receiver operating characteristics analysis showed the benefit of identifying plaque markers over cCTA stenosis grading alone, with AUCs increasing from 0.61 with ≥ 50% stenosis to 0.83 with addition of plaque markers to detect lesion-specific ischemia. Further incremental benefit was realized with the addition of CT-FFR (AUC 0.93). CONCLUSION: Coronary CTA-derived plaque markers portend predictive value to identify lesion-specific ischemia when compared to cCTA stenosis grading alone. The addition of CT-FFR to plaque markers shows incremental discriminatory power. KEY POINTS: • Coronary CT angiography (cCTA)-derived quantitative plaque markers of atherosclerosis portend high discriminatory power to identify lesion-specific ischemia. • Coronary CT angiography-derived fractional flow reserve (CT-FFR) shows superior diagnostic performance over cCTA alone in detecting lesion-specific ischemia. • A combination of plaque markers with CT-FFR provides incremental discriminatory value for detecting flow-limiting stenosis.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Diagnóstico por Computador/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Aprendizado de Máquina , Placa Aterosclerótica/diagnóstico , Estenose Coronária/etiologia , Estenose Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/complicações , Placa Aterosclerótica/fisiopatologia , Curva ROC , Estudos Retrospectivos
8.
Eur Radiol ; 28(7): 3097-3104, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29404770

RESUMO

OBJECTIVES: To investigate diagnostic accuracy and radiation dose of high-pitch CT coronary artery calcium scoring (CACS) with tin filtration (Sn100kVp) versus standard 120kVp high-pitch acquisition. METHODS: 78 patients (58% male, 61.5±9.1 years) were prospectively enrolled. Subjects underwent clinical 120kVp high-pitch CACS using third-generation dual-source CT followed by additional high-pitch Sn100kVp acquisition. Agatston scores, calcium volume scores, Agatston score categories, percentile-based risk categorization and radiation metrics were compared. RESULTS: 61/78 patients showed coronary calcifications. Median Agatston scores were 34.9 [0.7-197.1] and 41.7 [0.7-207.2] and calcium volume scores were 34.1 [0.7-218.0] for Sn100kVp and 35.7 [1.1-221.0] for 120kVp acquisitions, respectively (both p<0.0001). Bland-Altman analysis revealed underestimated Agatston scores and calcium volume scores with Sn100kVp versus 120kVp acquisitions (mean difference: 16.4 and 11.5). However, Agatston score categories and percentile-based risk categories showed excellent agreement (ĸ=0.98 and ĸ=0.99). Image noise was 25.8±4.4HU and 16.6±2.9HU in Sn100kVp and 120kVp scans, respectively (p<0.0001). Dose-length-product was 9.9±4.8mGy*cm and 40.9±14.4mGy*cm with Sn100kVp and 120kVp scans, respectively (p<0.0001). This resulted in significant effective radiation dose reduction (0.13±0.07mSv vs. 0.57±0.2mSv, p<0.0001) for Sn100kVp acquisitions. CONCLUSION: CACS using high-pitch low-voltage tin-filtered acquisitions demonstrates excellent agreement in Agatston score and percentile-based cardiac risk categorization with standard 120kVp high-pitch acquisitions. Furthermore, radiation dose was significantly reduced by 78% while maintaining accurate risk prediction. KEY POINTS: • Coronary artery calcium scoring with tin filtration reduces radiation dose by 78%. • There is excellent correlation between high-pitch Sn100kVp and standard 120kVp acquisitions. • Excellent agreement regarding Agatston score categories and percentile-based risk categorization was achieved. • No cardiac risk reclassifications were observed using Sn100kVp coronary artery calcium scoring.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Cálcio , Feminino , Filtração/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Medição de Risco/métodos , Estanho
9.
Eur Radiol ; 28(5): 2134-2142, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29181587

RESUMO

OBJECTIVES: To compare the diagnostic accuracy between low-kilovolt peak (kVp) (≤ 100) and high-kVp (> 100) third-generation dual-source coronary CT angiography (CCTA) using a kVp-tailored contrast media injection protocol. METHODS: One hundred twenty patients (mean age = 62.6 years, BMI = 29.0 kg/m2) who underwent catheter angiography and CCTA with automated kVp selection were separated into two cohorts (each n = 60, mean kVp = 84 and 117). Contrast media dose was tailored to the kVp level: 70 = 40 ml, 80 = 50 ml, 90 = 60 ml, 100 = 70 ml, 110 = 80 ml, and 120 = 90 ml. Contrast-to-noise ratio (CNR) was measured. Two observers evaluated image quality and the presence of significant coronary stenosis (> 50% luminal narrowing). RESULTS: Diagnostic accuracy (sensitivity/specificity) with ≤ 100 vs. > 100 kVp CCTA was comparable: per patient = 93.9/92.6% vs. 90.9/92.6%, per vessel = 91.5/97.8% vs. 94.0/96.8%, and per segment = 90.0/96.7% vs. 90.7/95.2% (all P > 0.64). CNR was similar (P > 0.18) in the low-kVp vs. high-kVp group (12.0 vs. 11.1), as ws subjective image quality (P = 0.38). Contrast media requirements were reduced by 38.1% in the low- vs. high-kVp cohort (53.6 vs. 86.6 ml, P < 0.001) and radiation dose by 59.6% (4.3 vs. 10.6 mSv, P < 0.001). CONCLUSIONS: Automated tube voltage selection with a tailored contrast media injection protocol allows CCTA to be performed at ≤ 100 kVp with substantial dose reductions and equivalent diagnostic accuracy for coronary stenosis detection compared to acquisitions at > 100 kVp. KEY POINTS: • Low-kVp coronary CT angiography (CCTA) enables reduced contrast and radiation dose. • Diagnostic accuracy is comparable between ≤ 100 and > 100 kVp CCTA. • Image quality is similar for low- and high-kVp CCTA. • Low-kVp image acquisition is facilitated by automated tube voltage selection. • Tailoring contrast injection protocols to the automatically selected kVp-level is feasible.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Idoso , Feminino , Seguimentos , Humanos , Injeções Intra-Arteriais , Masculino , Pessoa de Meia-Idade , Curva ROC , Doses de Radiação
10.
Eur Radiol ; 27(6): 2292-2297, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27686566

RESUMO

OBJECTIVES: To investigate the relationship between image quality and patient size at 100 kilovoltage (kV) compared to 120 kV ECG-gated Triple-Rule-Out CT angiography (TRO-CTA). METHODS: We retrospectively included 73 patients (age 64 ± 14 years) who underwent retrospective ECG-gated chest CTA. 40 patients were scanned with 100 kV while 33 patients with 120 kV. Body mass index (BMI), patients' chest circumference (PC) and thoracic surface area (TSA) were recorded. Quantitative image quality was assessed as vascular attenuation in the ascending aorta (AA), pulmonary trunk (PA) and left coronary artery (LCA) and the signal-to-noise ratio (SNR) in the AA. RESULTS: There was no significant difference in BMI (26.0 ± 4.6 vs. 28.0 ± 6.7 kg/m2), PC (103 ± 7 vs. 104 ± 10 cm2) and TSA (92 ± 15 vs. 91 ± 19 cm2) between 100 kV and 120 kV group. Mean vascular attenuation was significantly higher in the 100 kV compared to the 120 kV group (AA 438 vs. 354 HU, PA 460 vs. 349 HU, LCA 370 vs. 299 HU all p < 0.001). SNR was not significantly different, even after adjusting for patient size. Radiation dose was significantly lower in the 100 kV group (10.7 ± 4.1 vs. 20.7 ± 10.7 mSv; p < 0.001). CONCLUSIONS: 100 kV TRO-CTA is feasible in normal-to-overweight patients while maintaining image quality and achieving substantial dose reduction. KEY POINTS: • 100 kV protocols result in a significantly lower radiation dose. • Mean vascular attenuation is significantly higher using 100 kV. • SNR and CNR are not significantly different between 100 kV and 120 kV. • 100 kV CTA is feasible regardless of patient size while maintaining image quality.


Assuntos
Angiografia por Tomografia Computadorizada/normas , Sobrepeso/diagnóstico por imagem , Aorta/diagnóstico por imagem , Índice de Massa Corporal , Tamanho Corporal , Angiografia por Tomografia Computadorizada/métodos , Vasos Coronários/diagnóstico por imagem , Eletrocardiografia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar , Doses de Radiação , Estudos Retrospectivos , Razão Sinal-Ruído
11.
AJR Am J Roentgenol ; 209(2): 370-379, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28504564

RESUMO

OBJECTIVE: The purpose of this article is to present an overview of cinematic rendering, illustrating its potential advantages and applications. CONCLUSION: Volume-rendered reconstruction, obtaining 3D visualization from original CT datasets, is increasingly used by physicians and medical educators in various clinical and educational scenarios. Cinematic rendering is a novel 3D rendering algorithm that simulates the propagation and interaction of light rays as they pass through the volumetric data, showing a more photorealistic representation of 3D images than achieved with standard volume rendering.


Assuntos
Imageamento Tridimensional/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Interface Usuário-Computador
12.
AJR Am J Roentgenol ; 208(3): 495-504, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27897042

RESUMO

OBJECTIVE: Pulmonary CT angiography (CTA) is the imaging modality of choice in suspected acute pulmonary embolism (PE). Current pulmonary CTA techniques involve ever lower doses of contrast medium and radiation along with advanced postprocessing applications to enhance image quality, diagnostic accuracy, and provide added value in patient management. The objective of this article is to summarize these current developments and discuss the appropriate use of state-of-the-art pulmonary CTA. CONCLUSION: Pulmonary CTA is well established as a fast and reliable means of excluding or diagnosing PE. Continued developments in CT system hardware and postprocessing techniques will allow incremental reductions in radiation and contrast material requirements while improving image quality. Advances in risk stratification and prognostication from pulmonary CTA examinations should further refine its clinical value while minimizing the potential harm from overutilization and overdiagnosis.


Assuntos
Algoritmos , Angiografia por Tomografia Computadorizada/métodos , Embolia Pulmonar/diagnóstico por imagem , Exposição à Radiação/prevenção & controle , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doença Aguda , Meios de Contraste , Medicina Baseada em Evidências , Humanos , Reconhecimento Automatizado de Padrão/métodos , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Radiology ; 276(2): 339-57, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26203706

RESUMO

Owing to recent advances in computing power, iterative reconstruction (IR) algorithms have become a clinically viable option in computed tomographic (CT) imaging. Substantial evidence is accumulating about the advantages of IR algorithms over established analytical methods, such as filtered back projection. IR improves image quality through cyclic image processing. Although all available solutions share the common mechanism of artifact reduction and/or potential for radiation dose savings, chiefly due to image noise suppression, the magnitude of these effects depends on the specific IR algorithm. In the first section of this contribution, the technical bases of IR are briefly reviewed and the currently available algorithms released by the major CT manufacturers are described. In the second part, the current status of their clinical implementation is surveyed. Regardless of the applied IR algorithm, the available evidence attests to the substantial potential of IR algorithms for overcoming traditional limitations in CT imaging.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos
15.
Eur Radiol ; 25(3): 694-702, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25316059

RESUMO

OBJECTIVES: To evaluate the effect of a computer-aided detection (CAD) algorithm for coronary CT angiography (cCTA) on the performance of readers with different experience levels. METHODS: We studied 50 patients (18 women, 58 ± 11 years) who had undergone cCTA and quantitative coronary angiography (QCA). Eight observers with varying experience levels evaluated all studies for ≥50 % coronary artery stenosis. After 3 months, the same observers re-evaluated all studies, this time guided by a CAD system. Their performance with and without the CAD system (sensitivity, specificity, positive predictive value and negative predictive value) was assessed using the Likelihood Ratio Χ(2) test both at the per-patient and per-vessel levels. RESULTS: The sensitivity of the CAD system alone for stenosis detection was 71 % per-vessel and 100 % per-patient. There were 54 false positive (FP) findings within 199 analyzed vessels, most of them associated with non-obstructive (<50 %) lesions. With CAD, one (out of three, 33 %) inexperienced reader's per-patient sensitivity and negative predictive value significantly improved from 79 % to 100 % (P = 0.046) and from 90 % to 100 % (P = 0.034), respectively. Other readers' performance indices showed no statistically significant change. CONCLUSIONS: Our results suggest that CAD can improve some inexperienced readers' sensitivity for diagnosing coronary artery stenosis at cCTA.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Competência Clínica/normas , Meios de Contraste , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
17.
Radiology ; 270(3): 708-16, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24475833

RESUMO

PURPOSE: To compare the relative contributions of rest, stress, and delayed acquisitions with the accuracy of dual-energy (DE) computed tomography (CT) for the assessment of myocardial blood supply. MATERIALS AND METHODS: With institutional review board approval and HIPAA compliance, 55 consecutive patients (10 women, 45 men; mean age, 62 years ± 10) clinically referred for cardiac single photon emission computed tomography (SPECT) who were known to have or were suspected of having coronary artery disease were prospectively enrolled. DE CT studies were acquired during adenosine stress, at rest, and after 6-minute delay. The DE CT iodine distribution maps were visually assessed for perfusion deficits or late iodine enhancement. Per-segment agreement between modalities was investigated with κ statistics. Test characteristics for the detection of perfusion deficits were calculated for combinations of rest, stress, and delayed DE CT acquisition, with SPECT as reference standard. RESULTS: At SPECT, 714 segments were considered normal, 192 showed fixed perfusion defects, and 29 showed reversible perfusion deficits. Sensitivity of rest-only DE CT was 92%, and specificity was 98%. Stress-only, rest-stress, stress and delayed, and the combination of all three had a sensitivity of 99% and a specificity of 97%. Of 29 segments with reversible perfusion deficits at SPECT, 13 (45%) were misclassified by using rest-stress DE CT as fixed perfusion deficits. With stress DE CT plus delayed acquisition, 13 of 192 (7%) segments with fixed perfusion deficits at SPECT were misclassified as reversible. CONCLUSION: Rest-stress acquisition should be the protocol of choice for assessment of the myocardial blood supply in DE CT. The accuracy of DE CT is not increased by the addition of a delayed DE CT acquisition, which may therefore be omitted to reduce radiation exposure. With rest-stress DE CT, almost one-half of defects that are reversible at SPECT were classified as fixed; radiologists and clinicians need to be aware of this incongruence when they interpret DE CT myocardial perfusion studies.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X/métodos , Adenosina , Meios de Contraste , Teste de Esforço , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e Especificidade
18.
Radiology ; 273(3): 897-906, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25072187

RESUMO

PURPOSE: To prospectively determine the prevalence of pulmonary embolism ( PE pulmonary embolism ) and renal vein thrombosis ( RVT renal vein thrombosis ) with computed tomography (CT) and to identify markers predictive of PE pulmonary embolism and/or RVT renal vein thrombosis in a large consecutive cohort of patients with nephrotic syndrome. MATERIALS AND METHODS: This study was approved by the local institutional review board, and all patients or their guardians provided written informed consent. Consecutive patients with nephrotic syndrome (24-hour urine protein > 3.5 g) underwent combined CT pulmonary angiography for PE pulmonary embolism and renal CT venography for RVT renal vein thrombosis . Prevalence of PE pulmonary embolism and/or RVT renal vein thrombosis was estimated for different ages, sexes, and histopathologic types of nephrotic syndrome. Multivariate analysis was used to determine independent predictors for PE pulmonary embolism and/or RVT renal vein thrombosis in patients with nephrotic syndrome. RESULTS: There were 512 patients in the study cohort (331 male patients, 181 female patients; mean age, 37 years ± 17 [standard deviation]; range, 9-81 years), including 80 children. One hundred eighty (35%) of 512 patients had PE pulmonary embolism and/or RVT renal vein thrombosis , with PE pulmonary embolism the more common condition (85% [153 of 180]). PE pulmonary embolism was associated with RVT renal vein thrombosis in 85 (56%) of 153 patients and was isolated in 68 patients (44%). Most patients with PE pulmonary embolism (84% [128 of 153]) were asymptomatic. One hundred twelve (22%) of 505 patients had RVT renal vein thrombosis . PE pulmonary embolism and/or RVT renal vein thrombosis was found in 15 (19%) of 80 children with nephrotic syndrome, while 165 (38%) of 432 adult patients with nephrotic syndrome had PE pulmonary embolism and/or RVT renal vein thrombosis (P = .001). Membranous nephropathy was the most common histopathologic type associated with PE pulmonary embolism and/or RVT renal vein thrombosis (48% [88 of 183]). Membranous nephropathy, age greater than 60 years, high hemoglobin level, long prothrombin time, and high creatinine level were independent predictors of PE pulmonary embolism and/or RVT renal vein thrombosis (P < .05 for all). CONCLUSION: PE pulmonary embolism and RVT renal vein thrombosis are common in patients with nephrotic syndrome. PE pulmonary embolism is more common than RVT renal vein thrombosis , is most often asymptomatic, and is most frequently found in patients with membranous nephropathy. A high index of suspicion and a low threshold for diagnostic work-up is warranted in these patients.


Assuntos
Síndrome Nefrótica/complicações , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/etiologia , Veias Renais , Tomografia Computadorizada por Raios X , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/etiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia , Criança , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Embolia Pulmonar/epidemiologia , Interpretação de Imagem Radiográfica Assistida por Computador , Fatores de Risco , Índice de Gravidade de Doença , Trombose Venosa/epidemiologia
19.
AJR Am J Roentgenol ; 202(1): W43-9, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24370164

RESUMO

OBJECTIVE: The objective of our study was to evaluate the reproducibility of noncalcified coronary artery plaque burden quantification from coronary CT angiography (CTA) across different commercial analysis platforms. MATERIALS AND METHODS: For this study, 47 patients (36 men, 11 women; mean age ± SD, 62 ± 13 years) with noncalcified plaques on coronary CTA were included. Automated quantification of noncalcified coronary artery plaque volume was performed on identical datasets using three commercially available image analysis software platforms (software platforms 1-3). Identical tissue attenuation ranges between 0 and 50 HU for low-attenuation plaques and 50-130 HU for medium-attenuation plaques were consistently applied. Log volume data were compared with the Pearson correlation coefficient and Bland-Altman analysis. RESULTS: Differences in plaque volume measurements on intraplatform repeat measurements were statistically insignificant (p = 0.923). At the low-attenuation threshold, software platform 3 had significantly higher log volumes (p < 0.001) than both software platforms 1 and 2 and software platform 1 had significantly higher log volumes than software platform 2 (p < 0.001). The results at the medium-attenuation level were identical except that the log volumes for software platforms 1 and 2 were not significantly different (p > 0.05) in the left anterior descending artery and left circumflex artery. The Pearson correlation coefficient was found to be 0.677 (p < 0.001; 95% CI, 0.608-0.735) between software platforms 1 and 2, 0.672 (p < 0.001; 95% CI, 0.603-0.732) between software platforms 1 and 3, and 0.550 (p < 0.001; 95% CI, 0.463-0.627) between software platforms 2 and 3. CONCLUSION: Currently available noncalcified plaque quantification software provides good intraplatform reproducibility but poor interplatform reproducibility. Serial or comparative assessments require evaluation using the same software. Industry standards should be developed to enable reproducible assessments across manufacturers.


Assuntos
Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software
20.
J Comput Assist Tomogr ; 38(2): 179-84, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24625599

RESUMO

PURPOSE: To investigate the diagnostic accuracy of coronary computed tomographic (CT) angiography (CCTA) using filtered back projection (FBP) and sinogram-affirmed iterative reconstruction (SAFIRE) of different strength factors with invasive coronary angiography as the reference standard. MATERIALS AND METHODS: Fifty consecutive patients (32 men and 18 women) prospectively underwent electrocardiogram-triggered CCTA on a dual-source CT system. The acquisition window was set depending on the heart rate (HR): HR of less than 60 beats per minute (bpm) at the 70% RR interval, 61 to 80 bpm at 30% to 80% RR interval, and greater than 80 bpm at 30% to 50% RR interval; 100 kV and 359 to 377 mA s for patients with a body mass index of less than 24 kg/m, and 410 to 438 mA s at 120 kV for patients with a body mass index of 24 kg/m or greater. Image data were reconstructed using both FBP and SAFIRE. Sinogram-affirmed iterative reconstruction series were reconstructed using 3 different strength factors. Two blinded observers independently assessed the image quality and image impression of each coronary segment using a 4-point scale (1, non-diagnostic; and 4, excellent). Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured. Filtered back projection and all SAFIRE series were independently evaluated for coronary artery stenosis (>50%), and their diagnostic accuracy was compared with invasive coronary angiography. RESULTS: Statistically significant increases in SNR and CNR were obtained when higher strength factors were used. The highest SNR and CNR were found with the highest SAFIRE strength factor of 5; however, this strength also resulted in a more unfamiliar, "plasticlike" image appearance. Imaging quality scores of FBP and different SAFIRE strengths were 3.37 ± 0.49, 3.41 ± 0.47, 3.52 ± 0.30, and 3.48 ± 0.35, respectively (P < 0.001). The diagnostic accuracies were 92.91%, 93.76%, 95.28%, and 94.94% on per-segment level, respectively (P = 0.993). A tendency toward higher diagnostic performance was observed with SAFIRE strength factor 3 on per-segment analysis, albeit without reaching statistical significance. The effective radiation dose equivalent was 5.7 ± 1.6 mSv. CONCLUSION: Sinogram-affirmed iterative reconstruction provides significant improvements in image noise, SNR, and CNR compared with FBP, which are progressive with increasing SAFIRE strength factors. Sinogram-affirmed iterative reconstruction strength factor 3 or 5 is recommended for use with CCTA.


Assuntos
Angiografia Coronária/métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Cateterismo Cardíaco , Técnicas de Imagem de Sincronização Cardíaca , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA