Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-19696194

RESUMO

Electroacupuncture stimulation (EAS) has been demonstrated effective for pain relief and treating other various diseases. However, the conventional way of EAS, the bi-acupoint method, is not suitable for basis study of acupoint specificity. Moreover, its operations are inconvenient and difficult to be persevered, especially for long-term, continuous and even imperative treatments. These disadvantages motivate designs of new EAS methods. We present a novel uni-acupoint electrical stimulation method, which is applied at a single acupoint and quite meets the needs of basis study and simpler clinical application. Its pain relief effect has been evaluated by animal tests of Wistar rats. During the experiments, rats were given 30 min 2/100 Hz uni- and bi-acupoint EAS and their nociceptive thresholds before and after EAS were attained by hot-plate test. The analgesic effect was defined as the change of nociceptive threshold and used to evaluate the effectiveness of uni-acupoint EAS for pain relief. The hot-plate test results indicated that analgesic effect of uni-acupoint group was significantly higher than that of the control group and there was no significant difference of analgesic effects between uni- and bi-acupoint EAS. The results suggested that uni-acupoint method was an effective EAS method and had comparable pain relief effect with bi-acupoint method.

2.
Zhen Ci Yan Jiu ; 35(6): 429-32, 2010 Dec.
Artigo em Zh | MEDLINE | ID: mdl-21375016

RESUMO

OBJECTIVE: To observe the effect of electroacupuncture (EA) on serum tumor necrosis factor-alpha (TNF-alpha), IL-1 and IL-4 levels in rats with chronic inflammatory pain, so as to investigate its underlying mechanism in relieving pain. Methods Forty-eight SD rats were randomized into control, model, EA-unilateral ST 36, and EA-bilateral ST 36 groups, with 12 rats in each. Chronic inflammatory pain model was established by intradermal injection of Freund's complete adjuvant (0.1 mL) into the right paw. EA (2 Hz/100 Hz, 1-2-3 mA) was applied to the unilateral "Zusanli" (ST 36) and bilateral "Zusanli" (ST 36) for 30 min, once every 3 days and continuously for 4 weeks. Serum TNF-alpha, IL-1 and IL-4 contents were detected by enzyme linked immunosorbent assay. Results Compared with the control group, serum TNF-alpha, IL-1 and IL-4 contents of the model group increased significantly (P < 0.01), while in comparison with the model group, the levels of the 3 indexes were decreased considerably in both unilateral and bilateral ST 36 groups (P < 0.01). No significant differences were found between the unilateral ST 36 and bilateral ST 36 groups in serum TNF-alpha, IL-1 and IL-4 contents (P > 0.05). CONCLUSION: EA can effectively lower serum TNF-alpha, IL-1 and IL-4 levels in inflammatory pain rats, which may contribute to its effect in relieving inflammatory pain.


Assuntos
Pontos de Acupuntura , Eletroacupuntura , Interleucina-1/sangue , Interleucina-4/sangue , Manejo da Dor , Dor/imunologia , Fator de Necrose Tumoral alfa/sangue , Animais , Doença Crônica/terapia , Modelos Animais de Doenças , Humanos , Interleucina-1/imunologia , Interleucina-4/imunologia , Masculino , Dor/sangue , Distribuição Aleatória , Ratos , Ratos Sprague-Dawley , Fator de Necrose Tumoral alfa/imunologia
3.
Conf Proc IEEE Eng Med Biol Soc ; 2006: 4941-4, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17946663

RESUMO

Implanted nerve stimulation offers many advantages to improve the QOL (quality of life) of the patients suffering from nervous system diseases such as Parkinson's disease and epilepsy. Secondary battery begins to be used instead of primary secondary, service life of the implanted device is extended and the device becomes smaller and lighter. For charging the secondary battery fit in the body, a transcutaneous charger is designed. Two coupling coils designed specially are used to transmit and receive energy. With the mentioned coupling coils, the charger attains 15 mA charge current and the charge requirement is satisfied.


Assuntos
Terapia por Estimulação Elétrica , Eletrodos Implantados , Epilepsia/reabilitação , Doença de Parkinson/reabilitação , Pele/patologia , Fontes de Energia Elétrica , Eletrônica Médica , Desenho de Equipamento , Coração Artificial , Corpo Humano , Humanos , Modelos Estatísticos , Tecido Nervoso/patologia , Sistema Nervoso Periférico , Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA