RESUMO
BACKGROUND: Conduction disturbances and the need for permanent pacemaker (PPM) implantation remains a common complication for transcatheter aortic valve replacement (TAVR), particularly when self-expanding (SE) valves are used. AIMS: We compared in-hospital and 30-day rates of new PPM implantation between patients undergoing TAVR with SE valves using the conventional three-cusp coplanar implantation technique and the cusp-overlap technique. METHODS: We retrospectively compared patients without a pre-existing PPM who underwent a TAVR procedure with SE Evolut R or PRO valves using the cusp-overlap technique from July 2018 to September 2020 (n = 519) to patients who underwent TAVR using standard three-cusp technique from April 2016 to March 2017 (n = 128) in two high volume Canadian centers. RESULTS: There was no significant difference in baseline RBBB between the groups (10.4% vs. 13.2; p = 0.35). The rate of in-hospital new complete heart block (9.4% vs. 23.4%; p ≤ 0.001) and PPM implantation (8% vs. 21%; p ≤ 0.001) were significantly reduced when using the cusp-overlap technique. The incidence of new LBBB (30.4% vs. 29%; p = 0.73) was similar. At 30 days, the rates of new complete heart block (11% vs. 23%; p ≤ 0.001) and PPM implantation (10% vs. 21%, p ≤ 0.001) remained significantly lower in the cusp-overlap group, while the rate of new LBBB (35% vs. 30%; p = 0.73) was similar. CONCLUSION: Cusp-overlap approach offers several potential technical advantages compared to standard three-cusp view, and may result in lower PPM rates in TAVR with SE Evolut valve.
Assuntos
Estenose da Valva Aórtica , Bloqueio Atrioventricular , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Desenho de Prótese , Canadá , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgiaRESUMO
BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established treatment for severe aortic stenosis (AS), but despite estimates of life expectancy after TAVI being essential in heart team discussion, these data are scarce. Therefore, the current study sought to assess long-term survival and its trends in relation to chronological age, surgical risk, and treatment period.MethodsâandâResults: We included 2,414 consecutive patients who underwent TAVI for severe symptomatic AS between 2008 and 2021 at 2 international centers. For the analysis, long-term survival was evaluated according to age, surgical risk, and treatment period categorized into 3 groups, respectively. The longest follow-up was 13.5 years. Overall survival was 67.6% at 5 years and 26.9% at 10 years. Younger patients, lower surgical risk, and later treatment period showed better survival (log-rank P<0.001, respectively). In the multivariate analysis, age <75years, lower surgical risk, and later time period were significantly associated with better survival. The incidence of paravalvular leakage ≥moderate, red blood cell transfusion, and acute kidney injury were independently associated with increasing risk of 5-year death. CONCLUSIONS: In a real-world registry, survival was substantial following TAVI, especially in younger and lower surgical-risk patients, with improving outcomes over time. This should be considered in heart team discussions of life-long management for AS patients after TAVI.
Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Sistema de RegistrosRESUMO
Transcatheter edge-to-edge repair (TEER) is used extensively in patients with symptomatic severe mitral regurgitation and high surgical risk. While prosthetic valve endocarditis is well documented, infective endocarditis (IE) after TEER is a rare occurrence. To date, no study has been conducted on this complication. We report the case of an 85-year-old man who developed IE 3 months after undergoing TEER, and we systematically review 26 previously published cases of this complication. Our review findings indicate that discussion within the heart team is essential for the decision-making process and treatment strategy determination.
Assuntos
Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Masculino , Humanos , Idoso de 80 Anos ou mais , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/etiologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Endocardite/diagnóstico por imagem , Endocardite/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversosRESUMO
BACKGROUND: The effect of sex on mortality is controversial; furthermore, sex differences in left ventricular (LV) remodeling after transcatheter aortic valve implantation (TAVI) remain unknown.MethodsâandâResults:This study included 2,588 patients (1,793 [69.3%] female) enrolled in the Optimized CathEter vAlvular iNtervention (OCEAN)-TAVI Japanese multicenter registry between October 2013 and May 2017. We retrospectively analyzed the effect of sex on mortality, and evaluated changes in the LV mass index (LVMI) after TAVI. Female sex was significantly associated with lower all-cause and cardiovascular mortality (log-rank P<0.001 for both). Multivariate analysis showed that female sex was independently associated with lower cumulative long-term mortality (hazard ratio 0.615; 95% confidence interval 0.512-0.738; P<0.001). Regression in the LVMI was observed in both sexes, and there was no significant difference in the percentage LVMI regression from baseline to 1 year after TAVI between women and men. Women had a survival advantage compared with men among patients with LVMI regression at 1 year, but not among patients with no LVMI regression. CONCLUSIONS: We found that female sex is associated with better survival outcomes after TAVI in a large Japanese registry. Although LVMI regression was observed in women and men after TAVI, post-procedural LV mass regression may be related to the sex differences in mortality.
Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Hipertrofia Ventricular Esquerda , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Remodelação VentricularRESUMO
BACKGROUND: Difficulties are often encountered while controlling atrial fibrillation (AF), especially in hemodialysis (HD) patients. Previous data revealed that cryoballoon ablation (CBA) for treating paroxysmal atrial fibrillation (PAF) was not inferior to radiofrequency ablation (RFA); however, HD patients were excluded in this prior trial. Thus, the efficacy of CBA for HD patients is still unknown. METHODS: This retrospective study analyzed HD patients who underwent catheter ablation (CA) for AF from August 2011 to June 2019. Patients who received CBA (CBA group) and those who received RFA (RFA group) were compared. The primary endpoint was defined as freedom from a composite outcome (a documented recurrence of any atrial tachyarrhythmia or a prescription of antiarrhythmic drugs) at one year after CA. RESULTS: The RFA and CBA groups were composed of 21 and 23 patients, respectively. Freedom from a composite outcome was 58.4% in the RFA group and 68.2% in the CBA group (Log-rank: p = 0.571). CONCLUSION: Our results suggest that patients on HD with AF who were treated with CBA tended to have better outcomes than patients treated with RFA. Therefore, CBA could be a suitable ablation method for HD patients.
RESUMO
OBJECTIVE: To evaluate the short-, long-term clinical and angiographic outcomes after treatment of true bifurcation lesions using a modified jailed balloon technique (MJBT). BACKGROUND: Percutaneous coronary intervention (PCI) for true bifurcation lesions has high risk for adverse events. Side branch (SB) occlusion is one of the most serious complications. Therefore, novel strategies to avoid SB occlusion during main branch stenting and to keep its patency are important. METHODS AND RESULTS: Between February 2015 and February 2018, 328 patients with 349 true bifurcation lesions underwent PCI using MJBT. True bifurcation lesions were defined as Medina classifications (1.1.1), (1.0.1) or (0.1.1) lesions. We investigated the procedural and long-term clinical outcomes. Furthermore, angiographic outcomes were assessed at follow-up diagnostic angiography. The mean age of patients was 71.6 ± 9.9 years. Procedural success was achieved in all patients; postoperative SB occlusion was noted in only one patient (0.3%). The cumulative incidence of all-cause death was 23 patients (7.0%) in the follow-up period (median 717 days). Target lesion revascularization was performed in 19 patients (5.8%) with 23 lesions (6.6%), and 0.6% of myocardial infarction and 0% of definite stent thrombosis were observed. Angiographic follow-up was performed in 243 patients (74.1%); the percent diameter stenosis in SB was not significantly different between after the index procedure and follow-up angiography. CONCLUSIONS: This MJBT is safe and effective in preserving SB patency for true bifurcation lesions. Furthermore, long-term clinical and angiographic outcomes after MJBT are feasible.
Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana/terapia , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução VascularRESUMO
BACKGROUND: Asian patients have smaller aortic annuli. Although 20-mm balloon-expandable (BE) transcatheter heart valves (THV) are manufactured for transcatheter aortic valve implantation (TAVI) in these cases, the supra-annular design of self-expandable (SE) THV is considered more suitable; however, real-world comparative data are scarce.MethodsâandâResults:Consecutive TAVI cases (n=330) in a single Japanese center were reviewed. Based on the cutoff for the new-generation 20-/23-mm BE-THV, a small aortic annulus was defined as <330 mm2. A considerable number of patients had small annuli: 49/302 (16%). Of these, 33 BE-THV and 13 SE-THV using new-generation valves were compared. Although the SE-THV group had smaller annulus area (median 297 (interquartile range, 280-313) vs. 309 (303-323) mm2(P=0.022)), it had more favorable post-procedural parameters; for SE-THV and BE-THV, respectively, effective orifice area (EOA), 1.5 (1.3-1.6) vs. 1.1 cm2(0.9-1.3) (P=0.002); mean pressure gradient, 7.6 (5.6-11.0) vs. 14.2 mmHg (11.2-18.8) (P=0.001); and peak velocity, 1.8 (1.6-2.4) vs. 2.7 m/s (2.3-3.1) (P=0.001). Although new left bundle branch block was higher with SE-THV (24% and 62%, P=0.02), patient-prosthesis mismatch (PPM) ≥ moderate (indexed EOA <0.85 cm2/m2) was significantly less with SE-THV than with BE-THV (8% vs. 55%; P=0.04). Hemodynamic findings were consistent up to 1 year. CONCLUSIONS: Small annuli are often seen in Asian patients, for whom SE-THV implantation results in favorable hemodynamics with less PPM.
Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Humanos , Desenho de Prótese , Resultado do TratamentoRESUMO
Coronary artery disease is common in patients on dialysis; there is a high rate of bleeding events after percutaneous coronary intervention (PCI) in such patients. We investigated the impact of bleeding events after PCI on mortality in patients on hemodialysis. We included 386 consecutive hemodialysis patients who underwent PCI using a drug-eluting stent (DES) between September 2004 and December 2017 in our hospital, and investigated the impact of bleeding events on all-cause mortality after PCI. Bleeding events were assessed by the Thrombolysis in Myocardial Infarction (TIMI) bleeding definition within 24 months after PCI. A total of 42 patients experienced bleeding events. Of these, 30 patients (71.4%) had TIMI major bleeding events and 12 patients (28.6%) had TIMI minor bleeding events. Patients with bleeding events had significantly higher mortality than patients without bleeding events (survival rate, 55.1% vs 81.5%, log-rank: p < 0.001). These results suggest that bleeding events after PCI with a DES are notably associated with all-cause mortality among patients on hemodialysis. This is the first report about relationship between bleeding events and mortality to focus on patients on hemodialysis.
Assuntos
Doença da Artéria Coronariana/terapia , Hemorragia/etiologia , Nefropatias/terapia , Intervenção Coronária Percutânea/efeitos adversos , Diálise Renal , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Stents Farmacológicos , Feminino , Hemorragia/mortalidade , Humanos , Nefropatias/diagnóstico , Nefropatias/mortalidade , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/mortalidade , Diálise Renal/efeitos adversos , Diálise Renal/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
OBJECTIVES: This study investigated the relationship between the timing of ventricular tachycardia or ventricular fibrillation (VT or VF) and prognosis in patients undergoing primary percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI). BACKGROUND: It is unknown whether the timing of VT/VF occurrence affects the prognosis of patients with AMI. METHODS: From January 2004 to December 2014, 1004 patients with AMI underwent primary PCI. Of these patients, 888 did not have VT/VF (non-VT/VF group) and 116 had sustained VT/VF during prehospitalization or hospitalization. Patients with VT/VF were divided into two groups: early VT/VF (VT/VF occurrence before and within 2 days of admission, 92 patients) and late VT/VF (VT/VF occurrence >2 days after admission; 24 patients) groups. RESULTS: The frequency of VT/VF occurrence was high between the day of admission and the 2nd day and between days 6 and 10 of hospitalization. The late VT/VF group had a significantly longer onset-to-balloon time, lower ejection fraction, poorer renal function, and higher creatine phosphokinase (CK)-MB level on admission (p< 0.001). They also had a lower 30-day cardiac survival rate than the early VT/VF and non-VT/VF groups (42% vs. 76% vs. 96%, p < 0.001). Moreover, independent predictors of in-hospital cardiac mortality among patients with AMI who had sustained VT/VF were higher peak CK-MB [Odds ratio (OR: 1.001, 95%confidence interval (CI): 1.000-1.002, p= 0.03)], higher Killip class (OR: 1.484, 95%CI 1.017-2.165, p= 0.04), and late VT/VF (OR: 3.436, 95%CI 1.115-10.59, p= 0.03). CONCLUSIONS: The timing of VT/VF occurrences had a bimodal peak. Although late VT/VF occurrence after primary PCI was less frequent than early VT/VF occurrence, patients with late VT/VF had a very poor prognosis.
Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Complicações Pós-Operatórias , Taquicardia Ventricular , Fibrilação Ventricular , Idoso , Feminino , Humanos , Incidência , Japão , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/cirurgia , Avaliação de Processos e Resultados em Cuidados de Saúde , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/mortalidade , Prognóstico , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/mortalidade , Fatores de Tempo , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/mortalidadeRESUMO
BACKGROUND: Patients with severe aortic stenosis (AS) and an extra-large annulus (ELA) area (>683 mm2) can rarely be treated by transcatheter aortic valve replacement (TAVR) because of the size limitation of the transcatheter heart valves. This study aimed to evaluate the feasibility of TAVR using a 29-mm SAPIEN3 (S3) valve in patients with ELA and S3-dimensions by post-procedural computed tomography (post-CT). MethodsâandâResults: We included 261 patients undergoing TAVR using a 29-mm S3: 30 patients with ELA and 231 with non-ELA were identified. S3-dimensions were evaluated at the S3 inflow and annulus level by post-CT in 129 patients. The ELA group had a greater aortic annulus area measured by pre-procedural CT (737.3±54.7 vs. 578.4±41.9 mm2, P<0.0001), higher balloon inflation volume (36 vs. 33 mL, P<0.0001), a larger S3 area at inflow by post-CT (729.6±42.2 vs. 682.2±35.0 mm2, P<0.001), and a correlation between the inflation volume and S3 area (r=0.71, P=0.0005). No differences were observed between groups in paravalvular aortic regurgitation (PAR) ≥mild (43.3% vs. 27.6%, P=0.09), PAR ≥moderate (3.3% vs. 1.3%, P=0.39) or 1-year mortality (10.0% vs. 9.1%, P=0.87). CONCLUSIONS: TAVR using a 29-mm S3 with extra inflation of the delivery balloon can be considered as a treatment option for patients with severe AS and ELA.
Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Feminino , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Resultado do TratamentoRESUMO
Transcatheter aortic valve implantation (TAVI) is a viable treatment option for high-risk patients with severe aortic stenosis. In Japan, TAVI can be performed using first-generation self-expandable Medtronic CoreValve or balloon-expandable Edwards SAPIEN-XT from 2012. Since the durability and hemodynamic outcomes after transcatheter heart valve (THV) implantation in Japanese patients have not been clearly elucidated, we assessed serial changes in post-TAVI THV performances over a-3-year period by transthoracic echocardiography (TTE). From January 2012 to September 2014, among 83 patients with severe aortic stenosis, 26 underwent TAVI with CoreValve and 57 underwent TAVI with SAPIEN-XT. We assessed the serial changes in first post-implant (FPI) and 3-year post procedure THV hemodynamics by TTE. Valve performance was evaluated by serial assessment of aortic valve mean pressure gradient (PG) and aortic valve area (AVA) assessments. Three-year clinical outcomes were compared between the patients with CoreValve and those with SAPIEN-XT. Seventeen patients with CoreValve and 34 patients with SAPIEN-XT had FPI and 3-year TTEs. The AVA decreased significantly from FPI to 3-year follow-up among patients with SAPIEN-XT, but not among patients with CoreValve. The mean aortic PG decreased significantly from FPI to the 3-year follow-up point among patients with CoreValve; however, it was not significantly different from those with SAPIEN-XT. The absolute change in mean PG from FPI to the 3-year follow-up point decreased significantly among those with CoreValve compared to those with SAPIEN-XT. Clinical outcomes after TAVI were similar for both devices at 3-years after TAVI. In this study, long-term clinical outcomes for CoreValve and SAPIEN XT were similar. The 3-year THV performance of both devices was maintained after TAVI. Serial change in mean aortic PGs for CoreValve decreases significantly from FPI to the 3-year follow-up point compared to that for SAPIEN-XT.
Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/instrumentação , Hemodinâmica , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Valvuloplastia com Balão/efeitos adversos , Bioprótese , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia , Feminino , Próteses Valvulares Cardíacas , Humanos , Japão , Masculino , Desenho de Prótese , Análise de Sobrevida , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
OBJECTIVES: We propose a new systematic approach in bifurcation lesions, modified jailed balloon technique (M-JBT), and report the first clinical experience. BACKGROUND: Side branch occlusion brings with a serious complication and occurs in more than 7.0% of cases during bifurcation stenting. METHODS: A jailed balloon (JB) is introduced into the side branch (SB), while a stent is placed in the main branch (MB) as crossing SB. The size of the JB is half of the MB stent size. While the proximal end of JB attaching to MB stent, both stent and JB are simultaneously inflated with same pressure. JB is removed and then guidewires are recrossed. Kissing balloon dilatation (KBD) and/or T and protrusion (TAP) stenting are applied as needed. RESULTS: Between February 2015 and February 2016, 233 patients (254 bifurcation lesions including 54 left main trunk disease) underwent percutaneous coronary intervention (PCI) using this technique. Procedure success was achieved in all cases. KBD was performed for 183 lesions and TAP stenting was employed for 31 lesions. Occlusion of SV was not observed in any of the patients. Bench test confirmed less deformity of MB stent in M-JBT compared with conventional-JBT. CONCLUSIONS: This is the first report for clinical experiences by using modified jailed balloon technique. This novel M-JBT is safe and effective in the preservation of SB patency during bifurcation stenting.
Assuntos
Angioplastia Coronária com Balão/métodos , Doença da Artéria Coronariana/terapia , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Stents , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Grau de Desobstrução VascularRESUMO
BACKGROUND: Transcatheter aortic valve-in-valve (VIV) replacement within failed bioprosthetic surgical aortic valves is a feasible therapeutic option. However, data comparing the hemodynamic and clinical outcomes of VIV replacement with supra-annular self-expanding and balloon-expandable transcatheter heart valves (THV) are limited. MethodsâandâResults: Outcomes of 40 and 95 patients treated with supra-annular self-expanding and balloon-expandable THV, respectively, were compared after propensity score matching, which yielded 37 pairs of patients with similar baseline characteristics. Hemodynamic and clinical outcomes were analyzed. Postprocedural mean gradient was significantly lower in the self-expanding THV group than in the balloon-expandable THV group (12.1±6.1 mmHg vs. 19.0±7.3 mmHg, P<0.001). The incidence of at least mild postprocedural aortic regurgitation (AR) was comparable between the self-expanding and balloon-expandable THV groups (21.6% vs. 10.8%, P=0.39). In the self-expanding THV group, the new-generation THV showed a trend towards a lower incidence of at least mild AR compared with the early-generation THV (12.5% vs. 38.5%, P=0.07). A similar trend was observed in the balloon-expandable THV group (4.2% vs. 23.1%, P=0.08). There was no significant difference between the self-expanding and balloon-expandable THV groups in the cumulative 2-year all-cause mortality rates (22.4% vs. 43.4%, log-rank P=0.26). CONCLUSIONS: The supra-annular self-expanding THV was associated with a lower postprocedural mean gradient compared with balloon-expandable THV in patients undergoing aortic VIV replacement.
Assuntos
Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica , Feminino , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/normas , Substituição da Valva Aórtica Transcateter/tendências , Resultado do TratamentoRESUMO
BACKGROUND: Initial and long-term outcomes of the retrograde endovascular approach using a microcatheter for the treatment of chronic total occlusion (CTO) in the iliac or femoropopliteal (FP) arteries have not been fully elucidated. METHODS: From 2012 to 2014, 20 consecutive patients (21 limbs) underwent endovascular therapy (EVT) for CTO in the iliac or FP arteries using the microcatheter-based retrograde approach. An analysis of the initial and long-term outcomes was conducted. RESULTS: All procedures were successful. The mean follow-up duration was 27.4 ± 11.3 months. The mean patient age was 75.8 ± 9.1 years. Eighteen (85.7%) target lesions were located in the superficial femoral artery, 1 (4.8%) in the popliteal artery, and 2 (9.5%) in the iliac artery. All lesions were de novo. The mean occlusion length was 183.3 ± 95.4 mm. A stent was used in 19 (94.5%) lesions and balloon angioplasty was performed for 2 (5.5%) lesions. Retrograde puncture site complication (hematoma in popliteal artery) was reported in 1 (4.8%) patient. Postprocedure primary patency rates at 1, 2, and 3 years were 89.5%, 72.0%, and 41.2%, respectively, and the secondary patency rates at the corresponding time points were 100%, 77.2%, and 48.6%, respectively. CONCLUSIONS: Initial and long-term outcomes of EVT for CTO in iliac and FP arteries using the microcatheter-based retrograde approach are promising.
Assuntos
Procedimentos Endovasculares/instrumentação , Artéria Femoral , Artéria Ilíaca , Doença Arterial Periférica/terapia , Artéria Poplítea , Dispositivos de Acesso Vascular , Idoso , Idoso de 80 Anos ou mais , Angiografia , Angioplastia com Balão/instrumentação , Doença Crônica , Constrição Patológica , Intervalo Livre de Doença , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Desenho de Equipamento , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Masculino , Miniaturização , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Punções , Recidiva , Estudos Retrospectivos , Stents , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção , Grau de Desobstrução VascularRESUMO
BACKGROUND: It is recommended that not only door-to-balloon time but also prehospital delay for primary percutaneous coronary intervention (PCI) should be improved. We investigated the effect of prehospital transfer pathway on onset-to-balloon time and prognosis in patients with ST-segment elevation myocardial infarction (STEMI) in Japan. METHODSâANDâRESULTS: We analyzed data from 540 consecutive patients with primary PCI for STEMI. Patient clinical data and mortality were compared between patients who visited the family physician or non-PCI-capable hospitals and were then transferred to PCI-capable centers (indirect transfer patients), and those who directly visited PCI-capable centers (direct transfer patients). Onset-to-balloon time was longer in indirect transfer patients than in direct transfer patients (mean, 270 min; range, 180-480 min vs. 180 min, 120-240 min; P<0.001). In addition, patient prognosis was evaluated on Cox proportional regression analysis. Cardiac death and all-cause death were significantly higher in indirect transfer patients (odds ratios [OR], 2.17; 95% confidence intervals [95% CI]: 1.17-4.01, P=0.01; OR, 1.71; 95% CI: 1.09-2.68, P=0.02). These results were confirmed using propensity score matching for adjusted analyses. CONCLUSIONS: Patients with indirect transfer to regional emergency departments of PCI centers had longer onset-to-balloon time and worse prognosis than those with direct transfer.
Assuntos
Morte , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/cirurgia , Transferência de Pacientes , Intervenção Coronária Percutânea , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Fatores de TempoRESUMO
Background: Systemic sclerosis presents with a variety of cardiac manifestations, while myocarditis is usually a rare finding. Furthermore, there are no reports on the use of mitral transcatheter edge-to-edge repair (M-TEER) for the treatment of severe ventricular functional mitral regurgitation (vFMR) secondary to scleroderma myocarditis. Case summary: A-79-year-old male was admitted to our hospital because of fever and fatigue. His physical examination revealed thickening of the fingertips' skin, Raynaud phenomenon, and mild pedal oedema. Positive anti-centromere antibodies indicated a diagnosis of a limited cutaneous systemic sclerosis. He presented with symptoms of heart failure, and moderate to severe lymphocytic infiltration was evident in his endomyocardial biopsy. He responded well to medical therapy and was discharged. However, one month after hospital discharge, he was readmitted to our institution because of worsening heart failure. Transthoracic echocardiography showed a decrease in left ventricular systolic function and progression of left ventricular remodelling, which caused severe vFMR. Endomyocardial biopsy revealed decreased lymphocytic infiltration and mild myocardial interstitial fibrosis, indicative of scleroderma myocarditis. As he was unable to be weaned off inotropes, we performed M-TEER for severe vFMR, which led to a significant reduction in MR volume and improvement of heart failure symptoms. A week after procedure, immunosuppressive therapy was initiated and the patient was discharged home in stable condition. Discussion: Scleroderma myocarditis may manifest as heart failure with reduced ejection fraction with severe vFMR. Mitral transcatheter edge-to-edge repair for severe vFMR in the context of myocarditis can be one of the therapeutic options for haemodynamic stabilization.
RESUMO
Preexisting right bundle branch block (RBBB) is the strongest predictor for permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI). However, the risk assessment for new PPI and effective procedural strategy for preventing new PPI in patients with preexisting RBBB are still unclear. This study stratified the new PPI risk after TAVI and investigated the impact of implantation strategy in a preexisting RBBB cohort. We analyzed 237 patients with preexisting RBBB who underwent TAVI. The primary endpoint was the incidence of new PPI. Multivariate analyses investigating predictors for new PPI were performed. The overall PPI rate was 33.3%. Significant baseline predictors for new PPI were combination of RBBB, left anterior or posterior fascicular block, and first-degree atrioventricular block (odds ratio [OR] 2.55, 95% confidence interval [CI] 1.09 to 5.04), high calcium volume of noncoronary cusp (OR 2.08, 95% CI 1.05 to 4.10), and membranous septum (MS) length <2 mm (OR 2.02, 95% CI 1.09 to 3.75) in the univariate analysis and MS length <2 mm (OR 2.25, 95% CI 1.06 to 4.82) in the multivariate analysis. On the multivariate analysis including procedural variables, predilatation (OR 2.41, 95% CI 1.01 to 5.83), self-expanding valves (Corevalve, Evolut R, and Evolut Pro/Pro+; Medtronic Inc., Minneapolis, Minnesota) or mechanical expanding valves (Lotus/Lotus Edge; Boston Scientifics, Marlborough, Massachusetts) (OR 3.00, 95% CI 1.31 to 6.91), and implantation depth > MS length (OR 4.27, 95% CI 1.81 to 10.08) were significantly associated with new PPI. The incidence of new PPI increased according to the number of baseline predictors (0: 20.9%, 1: 34.3%, and ≥2: 52.0%) and procedural predictors (0: 3.7%, 1: 20.9%, 2: 40.5%, and 3: 60.0%). New PPI risk in a preexisting RBBB subset could be stratified by baseline factors. Device selection and implantation strategy considering MS length could prevent new PPI even in these high-risk population.
Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/terapia , Marca-Passo Artificial/efeitos adversos , Estenose da Valva Aórtica/complicações , Medição de Risco , Fatores de Risco , Valva Aórtica/cirurgia , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversosRESUMO
BACKGROUND/PURPOSE: Although the impact of predicted prosthesis-patient mismatch (PPMP) on outcomes after surgical aortic valve replacement is well established, studies on PPMP in transcatheter aortic valve replacement (TAVR) are limited. This study investigated the effects of PPMp on haemodynamic and 5-year clinical outcomes after TAVR. METHODS/MATERIALS: We analysed 1733 patients who underwent TAVR. PPMp was defined using two different methods: 1) normal reference values of the effective orifice area for each valve type and size indexed to body surface area (PPMp1; n = 1733) and 2) reference values for aortic annulus area or perimeter assessed with pre-procedural computed tomography indexed to body surface area (PPMp2; n = 1227). The primary endpoint was the composite of all-cause death and/or rehospitalisation for heart failure at 5 years. RESULTS: The incidence of PPMp1 was 11.7 % and 0.8 % in moderate and severe cases, respectively. PPMp2 was classified as either moderate (3.8 %) or severe (0 %). Rates of residual mean aortic gradient ≥20 mmHg significantly increased depending on PPMp1 severity (no PPMp1: 3.1 % vs. moderate PPMp1: 26.8 % vs. severe PPMp1: 53.9 %, p < 0.0001) and PPMp2 (no PPMp2: 4.1 % vs. moderate PPMp2: 12.8 %, p = 0.0049). Neither of PPMP methods were associated with the composite outcome in total cohort; however, PPMP1 was significantly related to worse clinical outcomes at 5 years among patients with reduced left ventricular ejection fraction (LVEF) in multivariate analysis (HR: 1.87; 95 % CI: 1.02-3.43). CONCLUSIONS: The impact of PPMP on TAVR clinical outcomes may not be negligible in patients with low LVEF.
RESUMO
BACKGROUND: In patients undergoing transcatheter aortic valve implantation (TAVI) for severe aortic stenosis (AS), data on the differences in subsequent cardiac structure and function among stratified groups with flow gradient patterns through the aortic valve are insufficient. METHODS: In this large multicenter study, 4,523 patients undergoing TAVI for severe AS between 2013 and 2019 were divided into 3 groups according to the following criteria: (1) high-gradient AS (HG-AS) (mean pressure gradient [MPG] ≥40 mmHg), (2) classical low-flow low-gradient AS (cLFLG-AS) (MPG <40 mmHg, left ventricular [LV] ejection fraction [LVEF] <50%), and (3) paradoxical low-flow low-gradient AS (pLFLG-AS) (MPG <40 mmHg, LVEF ≥50% but stroke volume index [SVi] <35 mL/m2). Echocardiography was performed at baseline, post-procedure, and 1 year post-TAVI. RESULTS: 3,697, 507, and 319 patients had HG-AS, cLFLG-AS, and pLFLG-AS, respectively. After adjusting for clinical factors, cLFLG-AS and pLFLG-AS had an approximately 1.5-fold higher 2-year all-cause mortality compared with HG-AS. During 1 year following TAVI, compared with HG-AS, cLFLG-AS showed greater reduction of LV systolic diameter (LVDs) and LV diastolic diameter (LVDd) and greater increase of LVEF (p<0.001 for all), and changes in LV mass index (LVMi) and SVi were comparable (p=0.915 and p=0.821, respectively). However, pLFLG-AS demonstrated less reduction of LVDs and LVDd (p=0.039 and p=0.001, respectively), less improvement of LVEF and LVMi (p=0.045 and p<0.001, respectively), and comparable change in SVi (p=0.364). CONCLUSIONS: During 1 year post-TAVI, compared with HG-AS, cLFLG-AS achieves smaller LV diameters, greater increase in LVEF, and comparable regression of LVMi, whereas pLFLG-AS does not.
RESUMO
Sodium-glucose cotransporter-2 inhibitors (SGLT2is) are widely used in cardiology and are effective in treating acute coronary syndrome (ACS). Their effects on unstable plaque in patients with ACS remains unclear. This study aimed to examine the effectiveness of SGLT2is in coronary plaque based on optical coherence tomography (OCT) images and the prognosis of ACS with type 2 diabetes mellitus. This retrospective study included 109 patients in the total cohort and 29 patients in the OCT cohort. Based on SGLT2i administration after ACS, the total cohort was categorized into non-SGLT2i (n = 69) and SGLT2i (n = 40) groups. The OCT cohort had 15 and 14 patients in the non-SGLT2i and SGLT2i groups, respectively. The OCT images of unstable plaque were analyzed in nonstented lesions during ACS catheterization and at the 6-month follow-up. The total cohort was assessed after 1 year for major adverse cardiovascular events, including all-cause mortality, revascularization, cerebrovascular disease, and heart failure hospitalization. SGLT2is improved unstable lesions with a significantly thicker fibrous cap (48 ± 15 µm vs 26 ± 24 µm, p = 0.005), reduced lipid arc (-29 ± 12° vs -18 ± 14°, p = 0.028), higher % decrease in total lipid arc (-35 ± 13% vs -19 ± 18%, p = 0.01), and lower major adverse cardiovascular event incidence (log-rank p = 0.023, hazard ratio 4.72 [1.08 to 20.63]) and revascularization rate (adjusted hazard ratio 6.77 [1.08 to 42.52]) than the non-SGLT2i group. In conclusion, SGLT2is can improve the markers of plaque stability and may improve the prognosis in patients with type 2 diabetes mellitus.