Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiology ; 278(3): 742-51, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26599666

RESUMO

PURPOSE: To implement hyperpolarized magnetic resonance (MR) imaging in an animal model of ischemia-reperfusion and to assess in vivo the regional changes in pyruvate metabolism within the 1st hour and at 1 week after a brief episode of coronary occlusion and reperfusion. MATERIALS AND METHODS: All animal experiments were performed with adherence to the Swiss Animal Protection law and were approved by the regional veterinary office. A closed-chest rat model was implemented by using an inflatable balloon secured around the left coronary artery. Animals were placed in an MR system 5-7 days after surgery. [1-(13)C]pyruvate was polarized by using a home-built multisample hyperpolarizer. Hyperpolarized pyruvate was injected at five stages: at baseline; at reperfusion after 15 minutes of coronary occlusion; and at 30 minutes, 60 minutes, and 1 week after ischemia reperfusion. The conversion of pyruvate into lactate and bicarbonate was imaged by using dedicated MR sequences alongside wall motion and delayed enhancement imaging. After imaging, the heart was removed and stained to delineate the area at risk (AAR). Differences between AAR and remote myocardium were assessed by using a repeated measures analysis of variance and a post hoc Bonferroni multiple comparison test. RESULTS: Data were collected in 12 animals. Occlusion led to hypokinesia of the anterior or anterolateral segments of the myocardium. At reperfusion, the average lactate-to-bicarbonate ratio increased in the AAR relative to that at baseline (from 1.93 ± 0.48 to 3.01 ± 0.74, P < .001) and was significantly higher when compared with that in the remote area (1.91 ± 0.38, P < .001). In the 60 minutes after occlusion, the lactate-to-bicarbonate ratio in the AAR recovered but was still elevated relative to that in the remote area. One week after ischemia-reperfusion, no difference between AAR and remote area could be detected. CONCLUSION: Hyperpolarized metabolic MR imaging can be used to successfully detect acute changes in [1-(13)C]pyruvate metabolism after ischemia-reperfusion, thereby enabling in vivo monitoring of the metabolic effects of reperfusion strategies.


Assuntos
Imagem Cinética por Ressonância Magnética/métodos , Traumatismo por Reperfusão Miocárdica/diagnóstico , Miocárdio/metabolismo , Animais , Biomarcadores/metabolismo , Modelos Animais de Doenças , Eletrocardiografia , Feminino , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Razão Sinal-Ruído
2.
Echocardiography ; 32(1): 89-95, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24665977

RESUMO

AIMS: There are significant variations in the published normal values of two-dimensional speckle tracking-derived strain and strain rate. These occur even when authors use the same software. To measure strain, the operator creates a region of interest (ROI) to define the myocardium to be analyzed. The purpose of this study was to test the hypothesis that measurements vary significantly with the chosen ROI width. METHODS AND RESULTS: In 20 healthy subjects (11 males, mean age 17.6 ± 6.18 years) an apical four-chamber view (4CH) and parasternal short-axis view (SAX) were analyzed. Initially ROI width was set automatically by the software. Two subsequent measurements were obtained from each cine loop by choosing the ROI width one step narrower and one step wider than the automatic ROI width. The mean differences between the measurements of narrower and automatic ROI and between automatic and wider ROI were -1.8 ± 0.7% and -0.9 ± 0.5% for global longitudinal strain (SL), -2.2 ± 0.6% and -1.7 ± 0.7% for global circumferential strain (SC), -0.10 ± 0.06/sec and -0.07 ± 0.06/sec for global longitudinal strain rate (SrL), and -0.15 ± 0.09/sec and -0.12 ± 0.07/sec for global circumferential strain rate (SrC) (all P < 0.000). This corresponds to a relative difference to the mean of both measurements of -4.4 to -11.0%. CONCLUSION: Layer-specific myocardial deformation and curvature dependency lead to an inverse correlation between the chosen ROI width and strain and strain rate measurements. Just one step of ROI-width change leads to a significant bias. Precise ROI-width definition is essential but technical factors limit its feasibility.


Assuntos
Algoritmos , Técnicas de Imagem por Elasticidade/métodos , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Função Ventricular Esquerda/fisiologia , Adolescente , Módulo de Elasticidade/fisiologia , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA