1.
Europace ; 18(8): 1170-8, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26759125

RESUMO

AIMS: Pulmonary vein isolation (PVI) is an established therapy for atrial fibrillation (AF). However, PVI remains a time-consuming procedure. A novel multipolar irrigated radiofrequency (RF) ablation catheter (nMARQ™) is aiming to improve PVI. We investigated the influence on procedural parameters and assessed clinical outcomes after PVI using this novel catheter. METHODS AND RESULTS: Fifty-eight consecutive patients with paroxysmal AF were equally allocated (n = 29/group) to PVI treatment with (i) the novel multipolar ablation catheter (nMARQ™) and (ii) a standard single-tip ablation catheter (SAC). Study endpoints included procedure time, fluoroscopy time, radiation dose, RF time, number of energy applications, and clinical outcome defined as freedom from AF after a single procedure. Successful PVI was confirmed by a separate circular, multipolar mapping catheter in all patients treated with the nMARQ™. Pulmonary vein isolation was achieved in 100% in the SAC group. In the nMARQ™ group, PVI was suggested in all patients. However, confirmatory mapping revealed persistent pulmonary vein (PV) conduction in 19 out of 29 nMARQ™ patients. These patients underwent further ablation, which still failed to achieve PVI in 5 of the 29 nMARQ™ patients, mainly due to significant temperature rise in the oesophagus and device-related limitations reaching the right inferior PV. Mean fluoroscopy time (31 ± 12 vs. 23 ± 10 min, P < 0.05) and (132 ± 37 vs. 109 ± 30 min, P < 0.05) were longer in nMARQ™ vs. SAC patients. Radiofrequency time was shorter in nMARQ™ vs. SAC group (21 ± 9 vs. 35 ± 12 min, P < 0.001). Radiation dose and the number of energy applications did not differ between both groups. Clinical outcome analysis revealed no significant differences (nMARQ™: 72 vs. SAC: 72%) after a mean follow-up of 373 ± 278 days. CONCLUSION: The use of the nMARQ™ catheter is associated with important device-related limitations to achieve successful PVI. However, clinical outcomes were equivalent in nMARQ™- and SAC-treated patients.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter/instrumentação , Adenosina/sangue , Idoso , Anticoagulantes/uso terapêutico , Ablação por Cateter/efeitos adversos , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Fluoroscopia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Resultado do Tratamento
2.
Biomed Res Int ; 2018: 9784259, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30320138

RESUMO

INTRODUCTION: The value of contact force information for ablation of LA anterior line is unknown. In a prospective randomized clinical trial, we investigated if information on contact force during left atrial (LA) anterior line ablation reduces total radiofrequency time and results in higher rates of bidirectional line block in patients undergoing pulmonary vein isolation (PVI) plus substrate modification. METHODS: We included patients with indication for pulmonary vein isolation (PVI) and additional substrate modification. For LA anterior line ablation, patients were randomized to contact force information visible (n=35) or blinded (n=37). Patients received contrast enhanced cardiac magnetic resonance imaging (cMRI) before and 3-6 months after ablation to visualize the LA anterior line. Primary endpoint was radiofrequency time to achieve bidirectional line block. Secondary endpoints were completeness of the LA anterior line on cMRI, distribution of contact force, procedural data, adverse events, and 12 months success rate. RESULTS: In 72 patients (64±9 years, 68% male), bidirectional LA anterior line block was achieved in 70 (97%) patients. Radiofrequency time to bidirectional block did not differ significantly across groups (contact force information visible 23±18min versus contact force information blinded 21±15min, p=0.50). The LA anterior line was discernable on cMRI in 40 patients (82%) without significant differences across randomization groups (p=0.46). No difference in applied contact force was found depending on cMRI line visibility. Twelve-month success and adverse event rates were comparable across groups. CONCLUSION: Information on contact force does not significantly improve the ablation of LA anterior lines. CLINICAL TRIAL REGISTRATION: The trial was registered at http://www.clinicaltrials.gov by identifier: NCT02217657.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Força Muscular , Contração Miocárdica , Adulto , Cateterismo Cardíaco/métodos , Ablação por Cateter/métodos , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA