Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Am J Physiol Gastrointest Liver Physiol ; 326(6): G676-G686, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38591131

RESUMO

The motility of the gastrointestinal tract is coordinated in part by rhythmic slow waves, and disrupted slow-wave patterns are linked to functional motility disorders. At present, there are no treatment strategies that primarily target slow-wave activity. This study assessed the use of pacing to suppress glucagon-induced slow-wave dysrhythmias in the small intestine. Slow waves in the jejunum were mapped in vivo using a high-resolution surface-contact electrode array in pigs (n = 7). Glucagon was intravenously administered to induce hyperglycemia. Slow-wave propagation patterns were categorized into antegrade, retrograde, collision, pacemaker, and uncoupled activity. Slow-wave characteristics such as period, amplitude, and speed were also quantified. Postglucagon infusion, pacing was applied at 4 mA and 8 mA and the resulting slow waves were quantified spatiotemporally. Antegrade propagation was dominant throughout all stages with a prevalence of 55 ± 38% at baseline. However, glucagon infusion resulted in a substantial and significant increase in uncoupled slow waves from 10 ± 8% to 30 ± 12% (P = 0.004) without significantly altering the prevalence of other slow-wave patterns. Slow-wave frequency, amplitude, and speed remained unchanged. Pacing, particularly at 8 mA, significantly suppressed dysrhythmic slow-wave patterns and achieved more effective spatial entrainment (85%) compared with 4 mA (46%, P = 0.039). This study defined the effect of glucagon on jejunal slow waves and identified uncoupling as a key dysrhythmia signature. Pacing effectively entrained rhythmic activity and suppressed dysrhythmias, highlighting the potential of pacing for gastrointestinal disorders associated with slow-wave abnormalities.NEW & NOTEWORTHY Glucagon was infused in pigs to induce hyperglycemia and the resulting slow-wave response in the intact jejunum was defined in high resolution for the first time. Subsequently, with pacing, the glucagon-induced dysrhythmias were suppressed and spatially entrained for the first time with a success rate of 85%. The ability to suppress slow-wave dysrhythmias through pacing is promising in treating motility disorders that are associated with intestinal dysrhythmias.


Assuntos
Motilidade Gastrointestinal , Glucagon , Jejuno , Animais , Suínos , Motilidade Gastrointestinal/fisiologia , Jejuno/fisiopatologia , Intestino Delgado/fisiopatologia , Feminino , Hiperglicemia/terapia , Masculino
2.
Am J Physiol Gastrointest Liver Physiol ; 324(5): G329-G340, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36809176

RESUMO

Gastric pacing has shown preclinical success in modulating bioelectrical slow-wave activity and has potential as a novel therapy for functional motility disorders. However, the translation of pacing techniques to the small intestine remains preliminary. This paper presents the first high-resolution framework for simultaneous pacing and response mapping of the small intestine. A novel surface-contact electrode array, capable of simultaneous pacing and high-resolution mapping of the pacing response, was developed and applied in vivo on the proximal jejunum of pigs. Pacing parameters including the input energy and pacing electrode orientation were systematically evaluated, and the efficacy of pacing was determined by analyzing spatiotemporal characteristics of entrained slow waves. Histological analysis was conducted to determine if the pacing resulted in tissue damage. A total of 54 studies were conducted on 11 pigs, and pacemaker propagation patterns were successfully achieved at both low (2 mA, 50 ms) and high (4 mA, 100 ms) energy levels with the pacing electrodes oriented in the antegrade, retrograde, and circumferential directions. The high energy level performed significantly better (P = 0.014) in achieving spatial entrainment. Comparable success (greater than 70%) was achieved when pacing in the circumferential and antegrade pacing directions, and no tissue damage was observed at the pacing sites. This study defined the spatial response of small intestine pacing in vivo revealing effective pacing parameters for slow-wave entrainment in the jejunum. Intestinal pacing now awaits translation to restore disordered slow-wave activity associated with motility disorders.NEW & NOTEWORTHY A novel surface-contact electrode array customized for the small intestine anatomy enabled simultaneous pacing and high-resolution response mapping. The spatial response of small intestine bioelectrical activity to pacing was mapped for the first time in vivo. Antegrade and circumferential pacing achieved spatial entrainment over 70% of the time and their induced pattern was held for 4-6 cycles postpacing at high energy (4 mA, 100 ms, at ∼2.7 s which corresponds to 1.1 × intrinsic frequency).


Assuntos
Motilidade Gastrointestinal , Jejuno , Animais , Suínos , Motilidade Gastrointestinal/fisiologia , Intestino Delgado/fisiologia , Estômago/fisiologia
3.
Am J Physiol Gastrointest Liver Physiol ; 325(1): G62-G79, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37162180

RESUMO

Patients with irritable bowel syndrome (IBS) have recurrent lower abdominal pain, associated with altered bowel habit (diarrhea and/or constipation). As bowel habit is altered, abnormalities in colonic motility are likely to contribute; however, characterization of colonic motor patterns in patients with IBS remains poor. Utilizing fiber-optic manometry, we aimed to characterize distal colonic postprandial colon motility in diarrhea-predominant IBS. After an overnight fast, a 72-sensor (spaced at 1-cm intervals) manometry catheter was colonoscopically placed to the proximal colon, in 13 patients with IBS-D and 12 healthy adults. Recordings were taken for 2 h pre and post a 700 kcal meal. Data were analyzed with our two developed automated techniques. In both healthy adults and patients with IBS-D, the dominant frequencies of pressure waves throughout the colon are between 2 and 4 cycles per minute (cpm) and the power of these frequencies increased significantly after a meal. Although these pressure waves formed propagating contractions in both groups, the postprandial propagating contraction increase was significantly smaller in patients compared with healthy adults. In healthy adults during the meal period, retrograde propagation between 2 and 8 cpm was significantly greater than antegrade propagation at the same frequencies. This difference was not observed in IBS-D. Patients with IBS-D show reduced prevalence of the retrograde cyclic motor pattern postprandially compared with the marked prevalence in healthy adults. We hypothesize that this reduction may allow premature rectal filling, leading to postprandial urgency and diarrhea.NEW & NOTEWORTHY Compared with healthy adults this study has shown a significant reduction in the prevalence of the postprandial retrograde cyclic motor pattern in the distal colon of patients with diarrhea-predominant irritable bowel syndrome. We hypothesize that this altered motility may allow for premature rectal filling which contributes to the postprandial urgency and diarrhea experienced by these patients.


Assuntos
Síndrome do Intestino Irritável , Adulto , Humanos , Colo , Constipação Intestinal , Diarreia , Reto , Período Pós-Prandial , Motilidade Gastrointestinal
4.
Colorectal Dis ; 25(11): 2257-2265, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37800177

RESUMO

AIM: Faecal incontinence is common and of multifactorial aetiologies, yet current diagnostic tools are unable to assess nerve and sphincter function objectively. We developed an anorectal high-density electromyography (HD-EMG) probe to evaluate motor-evoked potentials induced via trans-sacral magnetic stimulation (TSMS). METHOD: Anorectal probes with an 8 × 8 array of electrodes spaced 1 cm apart were developed for recording HD-EMG of the external anal sphincter. These HD-EMG probes were used to map MEP amplitudes and latencies evoked via TSMS delivered through the Magstim Rapid2 (MagStim Company). Patients undergoing pelvic floor investigations were recruited for this IDEAL Stage 2a pilot study. RESULTS: Eight participants (median age 49 years; five female) were recruited. Methodological viability, safety and diagnostic workflow were established. The test was well tolerated with median discomfort scores ≤2.5/10, median pain scores ≤1/10 and no adverse events. Higher Faecal Incontinence Severity Index scores correlated with longer MEP latencies (r = 0.58, p < 0.001) and lower MEP amplitudes (r = -0.32, p = 0.046), as did St. Mark's Incontinence Scores with both MEP latencies (r = 0.49, p = 0.001) and MEP amplitudes (r = -0.47, p = 0.002). CONCLUSION: This HD-EMG probe in conjunction with TSMS presents a novel diagnostic tool for anorectal function assessment. Spatiotemporal assessment of magnetically stimulated MEPs correlated well with symptoms and offers a feasible, safe and patient-tolerable method of evaluating pudendal nerve and external anal sphincter function. Further clinical development and evaluation of these techniques is justified.


Assuntos
Incontinência Fecal , Humanos , Feminino , Pessoa de Meia-Idade , Eletromiografia/efeitos adversos , Incontinência Fecal/etiologia , Diafragma da Pelve , Projetos Piloto , Potenciais Evocados , Canal Anal , Fenômenos Magnéticos
5.
Am J Physiol Gastrointest Liver Physiol ; 323(4): G318-G330, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-35916409

RESUMO

Coordinated contractions across the small and large intestines via the ileocecal junction (ICJ) are critical to healthy gastrointestinal function and are in part governed by myoelectrical activity. In this study, the spatiotemporal characteristics of the bioelectrical conduction across the ICJ and its adjacent regions were quantified in anesthetized rabbits. High-resolution mapping was applied from the terminal ileum (TI) to the sacculus rotundus (SR), across the ICJ and into the beginning of the large intestine at the cecum ampulla coli (AC). Orally propagating slow wave patterns in the SR did not entrain the TI. However, aborally propagating patterns from the TI were able to entrain the SR. Bioelectrical activity was recorded within the ICJ and AC, revealing complex interactions of slow waves, spike bursts, and bioelectrical quiescence. This suggests the involvement of myogenic coordination when regulating motility between the small and large intestines. Mean slow wave frequency between regions did not vary significantly (13.74-17.16 cycles/min). Slow waves in the SR propagated with significantly faster speeds (18.51 ± 1.57 mm/s) compared with the TI (14.05 ± 2.53 mm/s, P = 0.0113) and AC (9.56 ± 1.56 mm/s, P = 0.0001). Significantly higher amplitudes were observed in both the TI (0.28 ± 0.13 mV, P = 0.0167) and SR (0.24 ± 0.08 mV, P = 0.0159) within the small intestine compared with the large intestine AC (0.03 ± 0.01 mV). We hypothesize that orally propagating slow waves facilitate a motor-brake pattern in the SR to limit outflow into the ICJ, similar to those previously observed in other gastrointestinal regions.NEW & NOTEWORTHY Competing slow wave pacemakers were observed in the terminal ileum and sacculus rotundus. Prevalent oral propagation in the sacculus rotundus toward the terminal ileum potentially acts as a brake mechanism limiting outflow. Slow waves and periods of quiescence at the ileocecal junction suggest that activation may depend on the coregulatory flow and distention pathways. Slow waves and spike bursts in the cecum impart a role in the coordination of motility.


Assuntos
Motilidade Gastrointestinal , Íleo , Animais , Ceco , Motilidade Gastrointestinal/fisiologia , Íleo/fisiologia , Intestino Grosso , Intestino Delgado/fisiologia , Coelhos
6.
Am J Physiol Gastrointest Liver Physiol ; 322(4): G431-G445, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35137624

RESUMO

Gastric motility is coordinated by underlying bioelectrical slow waves. Gastric dysrhythmias occur in gastrointestinal (GI) motility disorders, but there are no validated methods for eliminating dysrhythmias. We hypothesized that targeted ablation could eliminate pacemaker sites in the stomach, including dysrhythmic ectopic pacemaker sites. In vivo high-resolution serosal electrical mapping (16 × 16 electrodes; 6 × 6 cm) was applied to localize normal and ectopic gastric pacemaker sites in 13 anesthetized pigs. Radiofrequency ablation was performed in a square formation surrounding the pacemaker site. Postablation high-resolution mapping revealed that ablation successfully induced localized conduction blocks after 18 min (SD 5). Normal gastric pacemaker sites were eliminated by ablation (n = 6), resulting in the emergence of a new pacemaker site immediately distal to the original site in all cases. Ectopic pacemaker sites were similarly eliminated by ablation in all cases (n = 7), and the surrounding mapped area was then entrained by normal antegrade activity in five of those cases. Histological analysis showed that ablation lesions extended through the entire depth of the muscle layer. Immunohistochemical staining confirmed localized interruption of the interstitial cell of Cajal (ICC) network through the ablation lesions. This study demonstrates that targeted gastric ablation can effectively modulate gastric electrical activation, including eliminating ectopic sites of slow wave activation underlying gastric dysrhythmias, without disrupting surrounding conduction capability or tissue structure. Gastric ablation presents a powerful new research tool for modulating gastric electrical activation and may likely hold therapeutic potential for disorders of gastric function.NEW & NOTEWORTHY This study presents gastric ablation as a novel tool for modulating gastric bioelectrical activation, including eliminating the normal gastric pacemaker site as well as abnormal ectopic pacemaker sites underlying gastric dysrhythmias. Targeted application of radiofrequency ablation was able to eliminate these pacemaker sites without disrupting surrounding conduction capability or tissue structure. Gastric ablation presents a powerful new research tool for modulating gastric electrical activation and may likely hold therapeutic potential for disorders of gastric function.


Assuntos
Ablação por Cateter , Gastroenteropatias , Células Intersticiais de Cajal , Animais , Motilidade Gastrointestinal/fisiologia , Células Intersticiais de Cajal/fisiologia , Membrana Serosa , Estômago/fisiologia , Suínos
7.
Am J Physiol Gastrointest Liver Physiol ; 323(4): G295-G305, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35916432

RESUMO

Gastric disorders are increasingly prevalent, but reliable noninvasive tools to objectively assess gastric function are lacking. Body-surface gastric mapping (BSGM) is a noninvasive method for the detection of gastric electrophysiological features, which are correlated with symptoms in patients with gastroparesis and functional dyspepsia. Previous studies have validated the relationship between serosal and cutaneous recordings from limited number of channels. This study aimed to comprehensively evaluate the basis of BSGM from 64 cutaneous channels and reliably identify spatial biomarkers associated with slow-wave dysrhythmias. High-resolution electrode arrays were placed to simultaneously capture slow waves from the gastric serosa (32 × 6 electrodes at 4 mm spacing) and epigastrium (8 × 8 electrodes at 20 mm spacing) in 14 porcine subjects. BSGM signals were processed based on a combination of wavelet and phase information analyses. A total of 1,185 individual cycles of slow waves were assessed, out of which 897 (76%) were classified as normal antegrade waves, occurring in 10 (71%) subjects studied. BSGM accurately detected the underlying slow wave in terms of frequency (r = 0.99, P = 0.43) as well as the direction of propagation (P = 0.41, F-measure: 0.92). In addition, the cycle-by-cycle match between BSGM and transitions of gastric slow wave dysrhythmias was demonstrated. These results validate BSGM as a suitable method for noninvasively and accurately detecting gastric slow-wave spatiotemporal profiles from the body surface.NEW & NOTEWORTHY Gastric dysfunctions are associated with abnormalities in the gastric bioelectrical slow waves. Noninvasive detection of gastric slow waves from the body surface can be achieved through multichannel, high-resolution, body-surface gastric mapping (BSGM). BSGM matched the spatiotemporal characteristics of gastric slow waves recorded directly and simultaneously from the serosal surface of the stomach. Abnormal gastric slow waves, such as retrograde propagation, ectopic pacemaker, and colliding wavefronts can be detected by changes in the phase of BSGM.


Assuntos
Gastroparesia , Estômago , Animais , Eletrodos , Fenômenos Eletrofisiológicos , Motilidade Gastrointestinal/fisiologia , Humanos , Membrana Serosa/fisiologia , Estômago/fisiologia , Suínos
8.
Am J Physiol Gastrointest Liver Physiol ; 323(6): G640-G652, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36255716

RESUMO

Gastric ablation has demonstrated potential to induce conduction blocks and correct abnormal electrical activity (i.e., ectopic slow-wave propagation) in acute, intraoperative in vivo studies. This study aimed to evaluate the safety and feasibility of gastric ablation to modulate slow-wave conduction after 2 wk of healing. Chronic in vivo experiments were performed in weaner pigs (n = 6). Animals were randomly divided into two groups: sham-ablation (n = 3, control group; no power delivery, room temperature, 5 s/point) and radiofrequency (RF) ablation (n = 3; temperature-control mode, 65°C, 5 s/point). In the initial surgery, high-resolution serosal electrical mapping (16 × 16 electrodes; 6 × 6 cm) was performed to define the baseline slow-wave activation profile. Ablation (sham/RF) was then performed in the mid-corpus, in a line around the circumferential axis of the stomach, followed by acute postablation mapping. All animals recovered from the procedure, with no sign of perforation or other complications. Two weeks later, intraoperative high-resolution mapping was repeated. High-resolution mapping showed that ablation successfully induced sustained conduction blocks in all cases in the RF-ablation group at both the acute and 2 wk time points, whereas all sham-controls had no conduction block. Histological and immunohistochemical evaluation showed that after 2 wk of healing, the lesions were in the inflammation and early proliferation phase, and interstitial cells of Cajal (ICC) were depleted and/or deformed within the ablation lesions. This safety and feasibility study demonstrates that gastric ablation can safely and effectively induce a sustained localized conduction block in the stomach without disrupting the surrounding slow-wave conduction capability.NEW & NOTEWORTHY Ablation has recently emerged as a tool for modulating gastric electrical activation and may hold interventional potential for disorders of gastric function. However, previous studies have been limited to the acute intraoperative setting. This study now presents the safety of gastric ablation after postsurgical recovery and healing. Localized electrical conduction blocks created by ablation remained after 2 wk of healing, and no perforation or other complications were observed over the postsurgical period.


Assuntos
Ablação por Cateter , Células Intersticiais de Cajal , Animais , Ablação por Cateter/efeitos adversos , Estudos de Viabilidade , Células Intersticiais de Cajal/fisiologia , Membrana Serosa , Estômago/fisiologia , Suínos
9.
Colorectal Dis ; 24(12): 1556-1566, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35793162

RESUMO

BACKGROUND: The rectosigmoid brake, characterised by retrograde cyclic motor patterns on high-resolution colonic manometry, has been postulated as a contributor to the maintenance of bowel continence. Sacral neuromodulation (SNM) is an effective therapy for faecal incontinence, but its mechanism of action is unclear. This study aims to investigate the colonic motility patterns in the distal colon of patients with faecal incontinence, and how these are modulated by SNM. METHODS: A high-resolution fibreoptic colonic manometry catheter, containing 36 sensors spaced at 1-cm intervals, was positioned in patients with faecal incontinence undergoing stage 1 SNM. One hour of pre- and post meal recordings were obtained followed by pre- and post meal recordings with suprasensory SNM. A 700-kcal meal was given. Data were analysed to identify propagating contractions. RESULTS: Fifteen patients with faecal incontinence were analysed. Patients had an abnormal meal response (fewer retrograde propagating contractions compared to controls; p = 0.027) and failed to show a post meal increase in propagating contractions (mean 17 ± 6/h premeal vs. 22 ± 9/h post meal, p = 0.438). Compared to baseline, SNM significantly increased the number of retrograde propagating contractions in the distal colon (8 ± 3/h premeal vs. 14 ± 3/h premeal with SNM, p = 0.028). Consuming a meal did not further increase the number of propagating contractions beyond the baseline upregulating effect of SNM. CONCLUSION: The rectosigmoid brake was suppressed in this cohort of patients with faecal incontinence. SNM may exert a therapeutic effect by modulating this rectosigmoid brake.


Assuntos
Terapia por Estimulação Elétrica , Incontinência Fecal , Humanos , Incontinência Fecal/terapia , Resultado do Tratamento , Reto , Colo , Plexo Lombossacral
10.
Am J Physiol Gastrointest Liver Physiol ; 321(6): G656-G667, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34612062

RESUMO

Gastric distension is known to affect normal slow-wave activity and gastric function, but links between slow-wave dysrhythmias and stomach function are poorly understood. Low-resolution mapping is unable to capture complex spatial properties of gastric dysrhythmias, necessitating the use of high-resolution mapping techniques. Characterizing the nature of these dysrhythmias has implications in the understanding of postprandial function and the development of new mapping devices. In this two-phase study, we developed and implemented a protocol for measuring electrophysiological responses to gastric distension in porcine experiments. In vivo, serosal high-resolution electrical mapping (256 electrodes; 36 cm2) was performed in anaesthetized pigs (n = 11), and slow-wave pattern, velocity, frequency, and amplitude were quantified before, during, and after intragastric distension. Phase I experiments (n = 6) focused on developing and refining the distension mapping methods using a surgically inserted intragastric balloon, with a variety of balloon types and distension protocols. Phase II experiments (n = 5) used barostat-controlled 500-mL isovolumetric distensions of an endoscopically introduced intragastric balloon. Dysrhythmias were consistently induced in all five gastric distensions, using refined distension protocols. Dysrhythmias appeared 23 s (SD = 5 s) after the distension and lasted 129 s (SD = 72 s), which consisted of ectopic propagation originating from the greater curvature in the region of distension. In summary, our results suggest that distension disrupts gastric entrainment, inducing temporary ectopic slow-wave propagation. These results may influence the understanding of the postprandial stomach and electrophysiological effects of gastric interventions.NEW & NOTEWORTHY This study presents the discovery of temporary dysrhythmic ectopic pacemakers in the distal stomach caused by localized gastric distension. Distension-induced dysrhythmias are an interesting physiological phenomenon that can inform the design of new interventional and electrophysiological protocols for both research and the clinic. The observation of distension-induced dysrhythmias also contributes to our understanding of stretch-sensitivity in the gut and may play an important role in normal and abnormal postprandial physiology.


Assuntos
Relógios Biológicos , Células Intersticiais de Cajal/fisiologia , Complexo Mioelétrico Migratório , Estômago/fisiologia , Animais , Feminino , Balão Gástrico , Sus scrofa , Fatores de Tempo
11.
Am J Physiol Gastrointest Liver Physiol ; 320(4): G573-G585, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33470186

RESUMO

Gastric motility is coordinated by underlying bioelectrical "slow wave" activity. Slow wave dysrhythmias are associated with motility disorders, including gastroparesis, offering an underexplored potential therapeutic target. Although ablation is widely used to treat cardiac arrhythmias, this approach has not yet been trialed for gastric electrical abnormalities. We hypothesized that ablation can create localized conduction blocks and modulate slow wave activation. Radiofrequency ablation was performed on the porcine serosa in vivo, encompassing a range of parameters (55-85°C, adjacent points forming a line, 5-10 s/point). High-resolution electrical mapping (16 × 16 electrodes; 6 × 6 cm) was applied to define baseline and acute postablation activation patterns. Tissue damage was evaluated by hematoxylin and eosin and c-Kit stains. Results demonstrated that RF ablation successfully induced complete conduction block and a full thickness lesion in the muscle layer at energy doses of 65-75°C for 5-10 s/point. Gastric ablation may hold therapeutic potential for gastric electrical abnormalities in the future.NEW & NOTEWORTHY This study presents gastric ablation as a new method for modulating slow wave activation and propagation in vivo, by creating localized electrical conduction blocks in the stomach, validated by high-resolution electrical mapping and histological tissue analysis. The results define the effective energy dose range for creating conduction blocks, while maintaining the mucosal and submucosal integrity, and demonstrate the electrophysiological effects of ablation. In future, gastric ablation can now be translated toward disrupting dysrhythmic slow wave activation.


Assuntos
Relógios Biológicos , Ablação por Cateter , Gastroparesia/cirurgia , Células Intersticiais de Cajal/patologia , Estômago/cirurgia , Animais , Condutividade Elétrica , Feminino , Motilidade Gastrointestinal , Gastroparesia/metabolismo , Gastroparesia/patologia , Gastroparesia/fisiopatologia , Células Intersticiais de Cajal/metabolismo , Proteínas Proto-Oncogênicas c-kit/metabolismo , Estômago/patologia , Estômago/fisiopatologia , Sus scrofa , Fatores de Tempo
12.
Biomed Eng Online ; 20(1): 105, 2021 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-34656127

RESUMO

BACKGROUND: Cyclic motor patterns (CMP) are the predominant motor pattern in the distal colon, and are important in both health and disease. Their origin, mechanism and relation to bioelectrical slow-waves remain incompletely understood. During abdominal surgery, an increase in the CMP occurs in the distal colon. This study aimed to evaluate the feasibility of detecting propagating slow waves and spike waves in the distal human colon through intraoperative, high-resolution (HR), serosal electrical mapping. METHODS: HR electrical recordings were obtained from the distal colon using validated flexible PCB arrays (6 × 16 electrodes; 4 mm inter-electrode spacing; 2.4 cm2, 0.3 mm diameter) for up to 15 min. Passive unipolar signals were obtained and analysed. RESULTS: Eleven patients (33-71 years; 6 females) undergoing colorectal surgery under general anaesthesia (4 with epidurals) were recruited. After artefact removal and comprehensive manual and automated analytics, events consistent with regular propagating activity between 2 and 6 cpm were not identified in any patient. Intermittent clusters of spike-like activities lasting 10-180 s with frequencies of each cluster ranging between 24 and 42 cpm, and an average amplitude of 0.54 ± 0.37 mV were recorded. CONCLUSIONS: Intraoperative colonic serosal mapping in humans is feasible, but unlike in the stomach and small bowel, revealed no regular propagating electrical activity. Although sporadic, synchronous spike-wave events were identifiable. Alternative techniques are required to characterise the mechanisms underlying the hyperactive CMP observed in the intra- and post-operative period. NEW FINDINGS: The aim of this study was to assess the feasibility of detecting propagating electrical activity that may correlate to the cyclic motor pattern in the distal human colon through intraoperative, high-resolution, serosal electrical mapping. High-resolution electrical mapping of the human colon revealed no regular propagating activity, but does reveal sporadic spike-wave events. These findings indicate that further research into appropriate techniques is required to identify the mechanism of hyperactive cyclic motor pattern observed in the intra- and post-operative period in humans.


Assuntos
Colo , Motilidade Gastrointestinal , Colo/cirurgia , Eletrodos , Estudos de Viabilidade , Feminino , Humanos
13.
Dig Dis Sci ; 66(3): 832-842, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32399665

RESUMO

BACKGROUND: Elevated colonic pressures and increased colonic activity have been thought to contribute to the pathophysiology of diverticulosis. However, evidence for this has been limited to low-resolution manometry, which is of limited accuracy. AIMS: This study aimed to evaluate the contraction pressures, counts, and distance of propagation recorded by high-resolution colonic manometry in diverticulosis vs control patients. METHODS: High-resolution colonic manometry was used to record descending and sigmoid colon activity pre- and post-meal in patients with established, asymptomatic diverticulosis and in healthy controls. Antegrade and retrograde propagating contractions, distance of propagation (mm), and mean contraction pressures (mmHg) in the descending and sigmoid colon were compared between patients and controls for all isolated propagating contractions, the cyclic motor pattern, and high-amplitude propagating contractions independently. RESULTS: Mean manometry pressures were not different between controls and diverticulosis patients (p > 0.05 for all comparisons). In the descending colon, diverticulosis patients had lower post-meal mean distance of propagation for all propagating contractions [10.8 (SE1.5) mm vs 20.0 (2.0) mm, p = 0.003] and the cyclic motor pattern [6.0 (2.5) mm vs 17.1 (2.8) mm, p = 0.01]. In the sigmoid colon, diverticulosis patients showed lower post-meal mean distance of propagation for all propagating contractions [10.8 (1.5) mm vs 20.2 (5.9) mm, p = 0.01] and a lower post-meal increase in retrograde propagating contractions (p = 0.04). CONCLUSIONS: In this first high-resolution colonic manometry study of patients with diverticular disease, we did not find evidence for increased manometric pressures or increased colonic activity in patients with diverticular disease.


Assuntos
Divertículo/fisiopatologia , Motilidade Gastrointestinal/fisiologia , Manometria/estatística & dados numéricos , Adulto , Idoso , Doenças Assintomáticas , Estudos de Casos e Controles , Colo Descendente/fisiopatologia , Colo Sigmoide/fisiopatologia , Feminino , Humanos , Masculino , Manometria/métodos , Refeições/fisiologia , Pessoa de Meia-Idade , Período Pós-Prandial/fisiologia , Pressão
14.
Surg Endosc ; 31(1): 477-486, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27129554

RESUMO

BACKGROUND: Gastric slow waves regulate peristalsis, and gastric dysrhythmias have been implicated in functional motility disorders. To accurately define slow wave patterns, it is currently necessary to collect high-resolution serosal recordings during open surgery. We therefore developed a novel gastric slow wave mapping device for use during laparoscopic procedures. METHODS: The device consists of a retractable catheter constructed of a flexible nitinol core coated with Pebax. Once deployed through a 5-mm laparoscopic port, the spiral head is revealed with 32 electrodes at 5 mm intervals. Recordings were validated against a reference electrode array in pigs and tested in a human patient. RESULTS: Recordings from the device and a reference array in pigs were identical in frequency (2.6 cycles per minute; p = 0.91), and activation patterns and velocities were consistent (8.9 ± 0.2 vs 8.7 ± 0.1 mm s-1; p = 0.2). Device and reference amplitudes were comparable (1.3 ± 0.1 vs 1.4 ± 0.1 mV; p = 0.4), though the device signal-to-noise ratio was higher (17.5 ± 0.6 vs 12.8 ± 0.6 dB; P < 0.0001). In the human patient, corpus slow waves were recorded and mapped (frequency 2.7 ± 0.03 cycles per minute, amplitude 0.8 ± 0.4 mV, velocity 2.3 ± 0.9 mm s-1). CONCLUSION: In conclusion, the novel laparoscopic device achieves high-quality serosal slow wave recordings. It can be used for laparoscopic diagnostic studies to document slow wave patterns in patients with gastric motility disorders.


Assuntos
Eletrodos , Motilidade Gastrointestinal/fisiologia , Laparoscopia/instrumentação , Estômago/fisiologia , Animais , Fenômenos Eletrofisiológicos , Humanos , Masculino , Microcirurgia , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído , Sus scrofa , Suínos
15.
Am J Physiol Gastrointest Liver Physiol ; 311(5): G895-G902, 2016 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-27659422

RESUMO

High-resolution (HR) mapping has been used to study gastric slow-wave activation; however, the specific characteristics of antral electrophysiology remain poorly defined. This study applied HR mapping and computational modeling to define functional human antral physiology. HR mapping was performed in 10 subjects using flexible electrode arrays (128-192 electrodes; 16-24 cm2) arranged from the pylorus to mid-corpus. Anatomical registration was by photographs and anatomical landmarks. Slow-wave parameters were computed, and resultant data were incorporated into a computational fluid dynamics (CFD) model of gastric flow to calculate impact on gastric mixing. In all subjects, extracellular mapping demonstrated normal aboral slow-wave propagation and a region of increased amplitude and velocity in the prepyloric antrum. On average, the high-velocity region commenced 28 mm proximal to the pylorus, and activation ceased 6 mm from the pylorus. Within this region, velocity increased 0.2 mm/s per mm of tissue, from the mean 3.3 ± 0.1 mm/s to 7.5 ± 0.6 mm/s (P < 0.001), and extracellular amplitude increased from 1.5 ± 0.1 mV to 2.5 ± 0.1 mV (P < 0.001). CFD modeling using representative parameters quantified a marked increase in antral recirculation, resulting in an enhanced gastric mixing, due to the accelerating terminal antral contraction. The extent of gastric mixing increased almost linearly with the maximal velocity of the contraction. In conclusion, the human terminal antral contraction is controlled by a short region of rapid high-amplitude slow-wave activity. Distal antral wave acceleration plays a major role in antral flow and mixing, increasing particle strain and trituration.


Assuntos
Motilidade Gastrointestinal/fisiologia , Células Intersticiais de Cajal/fisiologia , Antro Pilórico/fisiologia , Adulto , Idoso , Simulação por Computador , Fenômenos Eletrofisiológicos/fisiologia , Eletrofisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos
16.
Exp Physiol ; 101(9): 1206-1217, 2016 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-27265885

RESUMO

NEW FINDINGS: What is the central question of this study? This study aimed to provide the first comparison of simultaneous high-resolution mapping of anterior and posterior gastric serosa over sustained periods. What is the main finding and its importance? Episodes of spontaneous gastric slow-wave dysrhythmias increased significantly following intravenous infusion of vasopressin compared with the baseline state. A number of persistent dysrhythmias were defined, including ectopic activation, conduction block, rotor, retrograde and collision/merger of wavefronts. Slow-wave dysrhythmias could occur either simultaneously or independently on the anterior and posterior gastric serosa, and interacted depending on activation-repolarization and frequency dynamics. High-resolution mapping enables mechanistic insights into gastric slow-wave dysrhythmias and is now achieving clinical translation. However, previous studies have focused mainly on dysrhythmias occurring on the anterior gastric wall. The present study simultaneously mapped the anterior and posterior gastric serosa during episodes of dysrhythmias induced by vasopressin to aid understanding of dysrhythmia initiation, maintenance and termination. High-resolution mapping (8 × 16 electrodes on each serosa; 20-74 cm2 ) was performed in anaesthetized dogs. Baseline recordings (21 ± 8 min) were followed by intravenous infusion of vasopressin (0.1-0.5 IU ml-1 at 60-190 ml h-1 ) and further recordings (22 ± 13 min). Slow-wave activation maps, amplitudes, velocity, interval and frequency were calculated, and differences compared between baseline and postinfusion. All dogs demonstrated an increased prevalence of dysrhythmic events following infusion of vasopressin (17 versus 51%). Both amplitude and velocity demonstrated significant differences (baseline versus postinfusion: 3.6 versus 2.2 mV; 7.7 versus 6.5 mm s-1 ; P < 0.05 for both). Dysrhythmias occurred simultaneously or independently on the anterior and posterior serosa, and then interacted according to frequency dynamics. A number of persistent dysrhythmias were compared, including the following: ectopic activation (n = 2 animals), conduction block (n = 1), rotor (n = 2), retrograde (n = 3) and collision/merger of wavefronts (n = 2). We conclude that infusion of vasopressin induces gastric dysrhythmias, which occur across a heterogeneous range of frequencies and patterns. The results demonstrate that different classes of gastric dysrhythmias may arise simultaneously or independently in one or both surfaces of the serosa, then interact according to their relative frequencies. These results will help to inform interpretation of clinical dysrhythmia.

18.
Neuromodulation ; 19(8): 864-871, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27284964

RESUMO

BACKGROUND AND AIMS: High-frequency gastric electrical stimulation (GES) has emerged as a therapy for gastroparesis, but the mechanism(s) of action remain unclear. There is a need to refine stimulation protocols for clinical benefit, but a lack of accurate techniques for assessing mechanisms in clinical trials, such as slow wave modulation, has hindered progress. We thereby aimed to assess acute slow wave responses to GES in gastroparesis patients using high-resolution (HR) (multi-electrode) mapping, across a range of stimulation doses achievable by the Enterra stimulation device (Medtronic Inc., MN, USA). MATERIALS AND METHODS: Patients with medically refractory gastroparesis (n = 8) undergoing device implantation underwent intraoperative HR mapping (256 electrodes). Baseline recordings were followed by four protocols of increasing stimulation intensity, with washout periods. Slow wave patterns, frequency, velocity, amplitude, and dysrhythmia rates were quantified by investigators blinded to stimulation settings. RESULTS: There was no difference in slow wave pattern, frequency, velocity, or amplitude between baseline, washout, and stimulation periods (all p > 0.5). Dysrhythmias included ectopic pacemakers, conduction blocks, retrograde propagation, and colliding wavefronts, and dysrhythmia rates were unchanged with stimulation off vs. on (31% vs. 36% duration dysrhythmic; p > 0.5). Symptom scores and gastric emptying were improved at 5.8 month follow-up (p < 0.05). CONCLUSIONS: High-frequency GES protocols achievable from a current commercial device did not acutely modulate slow wave activity or dysrhythmias. This study advances clinical methods for identifying and assessing therapeutic GES parameters, and can be applied in future studies on higher-energy protocols and devices.


Assuntos
Terapia por Estimulação Elétrica/métodos , Gastroparesia/terapia , Adulto , Biofísica , Eletrodos Implantados , Feminino , Esvaziamento Gástrico/fisiologia , Humanos , Masculino , Manometria/métodos , Pessoa de Meia-Idade , Resultado do Tratamento
19.
Sci Rep ; 14(1): 6038, 2024 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-38472365

RESUMO

Pacing has been proposed as a therapy to restore function in motility disorders associated with electrical dysrhythmias. The spatial response of bioelectrical activity in the small intestine to pacing is poorly understood due to a lack of high-resolution investigations. This study systematically varied pacing parameters to determine the optimal settings for the spatial entrainment of slow wave activity in the jejunum. An electrode array was developed to allow simultaneous pacing and high-resolution mapping of the small intestine. Pacing parameters including pulse-width (50, 100 ms), pulse-amplitude (2, 4, 8 mA) and pacing electrode orientation (antegrade, retrograde, circumferential) were systematically varied and applied to the jejunum (n = 15 pigs). Pulse-amplitudes of 4 mA (p = 0.012) and 8 mA (p = 0.002) were more effective than 2 mA in achieving spatial entrainment while pulse-widths of 50 ms and 100 ms had comparable effects (p = 0.125). A pulse-width of 100 ms and a pulse-amplitude of 4 mA were determined to be most effective for slow wave entrainment when paced in the antegrade or circumferential direction with a success rate of greater than 75%. These settings can be applied in chronic studies to evaluate the long-term efficacy of pacing, a critical aspect in determining its therapeutic potential.


Assuntos
Motilidade Gastrointestinal , Jejuno , Animais , Suínos , Jejuno/fisiologia , Motilidade Gastrointestinal/fisiologia , Estimulação Elétrica , Eletrodos
20.
Ann Biomed Eng ; 52(3): 588-599, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37962674

RESUMO

Intestinal motility is governed in part by bioelectrical slow-waves and spike-bursts. Mesenteric ischemia is a substantial clinical challenge, but its electrophysiological and contractile mechanisms are not well understood. Simultaneous high-resolution bioelectrical and video mapping techniques were used to capture the changes in slow-waves, spike-bursts, and contractile activity during baseline, ischemia, and reperfusion periods. Experiments were performed on anesthetized pigs where intestinal contractions were quantified using surface strain and diameter measurements, while slow-wave and spike-bursts were quantified using frequency and amplitude. Slow-waves entrainment within the ischemic region diminished during ischemia, resulting in irregular slow-wave activity and a reduction in the frequency from 12.4 ± 3.0 cycles-per-minute (cpm) to 2.5 ± 2.7 cpm (p = 0.0006). At the end of the reperfusion period, normal slow-wave entrainment was observed at a frequency of 11.5 ± 2.9 cpm. There was an increase in spike-burst activity between the baseline and ischemia periods (1.1 ± 1.4 cpm to 8.7 ± 3.3 cpm, p = 0.0003) along with a spasm of circumferential contractions. At the end of the reperfusion period, the frequency of spike-bursts decreased to 2.7 ± 1.4 cpm, and contractions subsided. The intestine underwent tonal contraction during ischemia, with the diameter decreasing from 29.3 ± 2.6 mm to 21.2 ± 6.2 mm (p = 0.0020). At the end of the reperfusion period, the intestinal diameter increased to 27.3 ± 3.9 mm. The decrease in slow-wave activity, increase in spike-bursts, and tonal contractions can objectively identify ischemic segments in the intestine. It is anticipated that the use of electrophysiological slow-wave and spike-burst biomarkers, along with contractile measures, could identify mesenteric ischemia in surgical settings and allow an objective biomarker for successful revascularization.


Assuntos
Isquemia Mesentérica , Animais , Suínos , Intestinos , Motilidade Gastrointestinal/fisiologia , Isquemia , Contração Muscular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA